• Title/Summary/Keyword: Heating Condition

Search Result 1,304, Processing Time 0.029 seconds

Design of Aerosol Generator for Inhalation Toxicology Study of Lead and Evaluation with Real Time Monitoring (납의 흡입독성 연구를 위한 에어로졸 발생장치의 고안 및 실시간 모니터링을 이용한 성능평가)

  • Jeung Jae Yeal;Kim Jung Man;Kim Tae Hyeung;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.2
    • /
    • pp.373-379
    • /
    • 2002
  • This paper was the design of aerosol generator for inhalation toxicology study of lead and evaluation with real time monitoring, and applied several engineering methodology to classical aerosol generator to cope with it's disadvantages. According to the testing conditions, source temperature 50℃ and inlet-duct band heater temperature 150℃, aerosol generation results for sodium chloride and lead acetate were as followings: CPM(Count Per Minute) for Sodium chloride that used for the testing material in aerosol generation and inhalation system was decreased in the 2nd and the 3rd hour's serial trials, but CVs(coefficient of variation) were maintained within 10%. CPMs for 5 and 2.5 gram of lead acetate that used for aerosol generation and inhalation exposure of lead showed similar results because of the sedimentation of lead acetate on piezoelectric crystal with time. For that reason, heating and mixing of nebulizing solution will be needed to generate lead aerosol with stable profile and maximum generation efficiency. Fluctuations of 10 and 5 gram lead acetate were low but 2.5gram was high. However, CVs for 10, 5, and 2.5gram lead acetate were within 10%. Considering the theoretical efficiencies for sodium chloride and lead acetate, 5gram sodium chloride and 2.5gram lead acetate were appropriate choice. Aerosol generation characteristics for two materials with 1 hour interval were different with respect to the fluctuation of CPM and the decrease to 10gram in it's material. For that reason, sodium chloride can not be used to estimate the aerosol generation and it's related parts for lead acetate. According to the testing conditions, source temperature 20, 50, 70℃, and inlet-duct band heater temperature 20, 50, 100, 150, 200℃, aerosol generation results for sodium chloride and lead acetate were as followings: Excluding inlet-duct band temperature 200℃, maximum CPM for sodium chloride was manifested in source temperature 70℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing. Maximum CPMs for 10, 5, and 2.5gram sodium chloride were from source temperature 70℃ and inlet-duct band temperature 20℃. Excluding inlet-duct band temperature 50, 200℃, maximum CPMs for lead acetate were indicated in source temperature 50℃ with each inlet-duct band temperature conditions. We suggest that this condition was the optimum in the design of aerosol generator, inhalation system, and the testing for lead inhalation study. Source and inlet-duct band temperatures for 10, 5, 2.5gram lead acetate were 50 and 100℃, 50 and 100℃, 50 and 150℃, respectively. In conclusion, considering above 2 paragraphs of results for aerosol generation, 5gram efficiencies for sodium chloride, lead acetate were higher than 2.5gram's. If inlet-duct band temperature was same, aerosol generation was increased with increase of source temperature. To get maximum aerosol generation will be the conditions that set the appropriate inlet-duel band temperature for each materials and increase the source temperature.

Effect of Soil Temperature on the Emergence - Speed of Rice and Barnyardgrasses under Dry Direct - Seeding Condition (토양온도(土壞溫度)가 벼와 피의 출아속도(出芽速度)에 미치는 영향(影響))

  • Kwon, Y.W.;Kim, D.S.;Park, S.W.
    • Korean Journal of Weed Science
    • /
    • v.16 no.2
    • /
    • pp.81-87
    • /
    • 1996
  • Seeds of rice, cv. Ilpoom, and barnyardgrasses(Echinochloa crus-galli, vars. oryzicola, crux-galli, and praticola) were sown for a characterization of their responses to temperature during emergence under a dry direct-seeded condition. A laboratory-made aluminum block apparatus for emergence-temperature control conferred a linear continuous temperature gradient from 10 to $30^{\circ}C$ to the seeds from cooling to heating ends of the apparatus. The lowest temperature for emergence was $12.3^{\circ}C$ for rice cv. Ilpoom, and $11.0^{\circ}C$ for the three varieties of Echinochloa spp.. Percent emergence of rice increased sharply with an increase in temperature by ca. $20^{\circ}C$, then leveled-off, while those of barnyardgrasses increased almost linearly with temperatures up to $30^{\circ}C$. In rice the time required for emergence after seeding was shortened exponentially with increased temperature while those for barnyardgrasses were shortened almost linearly from 11 to $30^{\circ}C$. The temperature-response characteristic of rice in emergence-speed was almost the same among those for the 1st emergence, emergence by 25, 50, 75%, or average emergence time. At $13^{\circ}C$, $346.7^{\circ}C$ days of accummulated temperature(26.67 days) were required for the 1st emergence in rice while 131.7, 136.0, and $138.7^{\circ}C$ days(10.13, 10.46, and 10.67 days) were required for the 1st emergence in E. spp., vars. crus-galli, praticola, and oryzicola, respectively. Greater cold tolerance and increasingly faster emergence of barnyardgrasses than rice below $20^{\circ}C$ seem to render the barnyardgrasses as much more competitive than rice at lower temperatures.

  • PDF

Comparison of Climatic Conditions of Sweet Pepper's Greenhouse between Korea and the Netherlands (한국과 네덜란드의 파프리카 재배온실의 시설 내.외부 기상환경 비교)

  • Jeong, Won-Ju;Myoung, Dong-Ju;Lee, Jeong-Hyun
    • Journal of Bio-Environment Control
    • /
    • v.18 no.3
    • /
    • pp.244-252
    • /
    • 2009
  • This research aims at comparison of climatic conditions of sweet pepper's greenhouse between Korea (KOR) and the Netherlands (NL) to find out the reason of much lower yield in KOR than NL focus-ing on greenhouse climatic conditions. Hence, greenhouse climate data were obtained from each one commercial glasshouse in both countries. The crops (cv. 'Derby') were grown on rockwool slab with two stems per plant with 3.75plants/$m^2$ in KOR and three stems per plant with 2.5plants/$m^2$ or four stems per plant with 1.875plants/$m^2$ in NL. Even though plant density was differed but stem density was on the same to 7.5stems/$m^2$. There was no significantly difference on weekly growth of sweet pepper plant both countries, whereas harvested nodes to whole nodes of NL's plant was more than two times higher compared to KOR. The averaged daily global radiation during the whole growing periods was 14.5MJ/$m^2$/day in KOR and l2.1MJ/$m^2$/day in NL. Averaged 24h temperature was similar to both glasshouse as $21.6^{\circ}C$ in KOR and $21.2^{\circ}C$ in NL during the whole growing periods, however the variance was higher in KOR than NL. Humidity deficit (HD) was observed higher in KOR during the whole growing periods. Averaged day $CO_2$ concentration was measured contrary pattern in both countries because of heating to greenhouse on NL winter season. Averaged 24h temperature and day $CO_2$ concentration to daily global radiation was regular pattern in NL, whereas there are large scatter in KOR. Consequently, more irregular greenhouse climate condition in KOR could be induced irregularly crop growth.

A Survey on the Effect of Crate Type and Harvest Season on Preslaughter Condition and Mortality of Broiler (어리장 형태와 계절이 육계 출하환경 및 폐사에 미치는 영향)

  • Kim Dong-Hun;Park Beom-Young;Hwang In-Ho;Cho Soo-Hyun;Kim Jin-Hyung;Lee Jong-Moon
    • Food Science of Animal Resources
    • /
    • v.26 no.1
    • /
    • pp.37-42
    • /
    • 2006
  • The current study was conducted to investigate the effect of types of crate and season on transport condition and mortality, and ultimately to identify the best practice for reducing economic lose. Total loading weight stocking density, transport and lairage times and mortality were surveyed from the management data sheet of two companies for each first week of January, April, August and October, An average loading weight, length of transport and lairage times and mortality were 3.9 ton, 96 min, 478 min and 0.6%, respectively. Mortality after lairage was not significant between two types of crate. In addition, container type crate showed higher loading weight and stocking density than box type one. Spring and winter had significantly higher mortality with 0.7 and 0.8%, respectively, then summer and fell of 0.5%. An interaction between crate type and season on mortality showed that mortality for box type on was higher in spring and winter with 0.8 and 0.7%, respectively, compared to summer and fall of 0,3 and 0.4% respectively. In the case of container type crate, spring, fall and winter had greatly different death into with 0.7, 0.5 and 0.8%, respectively, while there was no difference between spring and summer, and between summer and winter, Mortality after transportation was similar between both crate type, with higher rate for spring and winder than other seasons. The result was likely related to death of exposure due to extended waiting time without heating facility.

Design of Thermo-optic Switch with Low Power Consumption by Electrode Optimization (전극 구조의 최적화를 통한 저전력 열광학 스위치 설계)

  • Choi, Chul-Hyun;Kong, Chang-Kyeng;Lee, Min-Woo;Sung, Jun-Ho;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.266-271
    • /
    • 2009
  • We designed a thermo-optic switch based on a directional coupler with not only a high extinction ratio but also significantly low power consumption. The switch operates by using the thermo-optic effect of the polymer which the refractive index changes by heating the electrode. If the electrode is not powered (OFF), the input light will be coupled completely to the other waveguide. When the electrode is powered at a certain level (ON), input light launched into the input waveguide will remain in that waveguide due to the lower index adjusted in the other waveguide. The switch based on the directional coupler was designed using the generalized extinction ratio curve and the lateral shift of the input waveguide. The coupling length is 1,610 ${\mu}m$ and the extinction ratios are -28 and -30 dB for ON and OFF states, respectively. The electrode structures were optimized by thermal analysis. The transported heat into the waveguide is increased, as the electrode width (w) is increased and the center distance between the electrode and the waveguide (d) is decreased. Also, because the heat generated in the electrode affects the other waveguide, the temperature difference between two waveguides is varied as the given w and d. There are specific conditions which have the maximum of the temperature difference. That of the temperature difference is increased as the width and the temperature of the electrode are increased. Especially, when the switch is designed using the condition with the maximum of the temperature difference for switching, the temperature of the electrode can be decreased. We expect this condition will be the novel method for the reduction of the power consumption in a thermo-optic switch.

On Securing Continuity of Long-Term Observational Eddy Flux Data: Field Intercomparison between Open- and Enclosed-Path Gas Analyzers (장기 관측 에디 플럭스 자료의 연속성 확보에 대하여: 개회로 및 봉폐회로 기체분석기의 야외 상호 비교)

  • Kang, Minseok;Kim, Joon;Yang, Hyunyoung;Lim, Jong-Hwan;Chun, Jung-Hwa;Moon, Minkyu
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.3
    • /
    • pp.135-145
    • /
    • 2019
  • Analysis of a long cycle or a trend of time series data based on a long-term observation would require comparability between data observed in the past and the present. In the present study, we proposed an approach to ensure the compatibility among the instruments used for the long-term observation, which would allow to secure continuity of the data. An open-path gas analyzer (Model LI-7500, LI-COR, Inc., USA) has been used for eddy covariance flux measurement in the Gwangneung deciduous forest for more than 10 years. The open-path gas analyzer was replaced by an enclosed-path gas analyzer (Model EC155, Campbell Scientific, Inc., USA) in July 2015. Before completely replacing the gas analyzer, the carbon dioxide ($CO_2$) and latent heat fluxes were collected using both gas analyzers simultaneously during a five-month period from August to December in 2015. It was found that the $CO_2$ fluxes were not significantly different between the gas analyzers under the condition that the daily mean temperature was higher than $0^{\circ}C$. However, the $CO_2$ flux measured by the open-path gas analyzer was negatively biased (from positive sign, i.e., carbon source, to 0 or negative sign, i.e., carbon neutral or sink) due to the instrument surface heating under the condition that the daily mean temperature was lower than $0^{\circ}C$. Despite applying the frequency response correction associated with tube attenuation of water vapor, the latent heat flux measured by the enclosed-path gas analyzer was on average 9% smaller than that measured by the open-path gas analyzer, which resulted in >20% difference of the sums over the study period. These results indicated that application of the additional air density correction would be needed due to the instrument heat and analysis of the long-term observational flux data would be facilitated by understanding the underestimation tendency of latent heat flux measurements by an enclosed-path gas analyzer.

Background effect on the measurement of trace amount of uranium by thermal ionization mass spectrometry (열이온화 질량분석에 의한 극미량 우라늄 정량에 미치는 바탕값 영향)

  • Jeon, Young-Shin;Park, Yong-Joon;Joe, Kih-Soo;Han, Sun-Ho;Song, Kyu-Seok
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.487-494
    • /
    • 2008
  • An experiment was performed for zone refined Re-filament and normal (nonzone refined) Re-filament to reduce the background effect on the measurement of low level uranium samples. From both filaments, the signals which seemed to come from a cluster of light alkali elements, $(^{39}K_6)^+$, $(^{39}K_5+^{41}K)^+$ and $PbO_2$ were identified as the isobaric effect of the uranium isotopes. The isobaric effect signal was completely disappeared by heating the filament about $2000^{\circ}C$ at < $10^{-7}$ torr of vacuum for more than 1.5 hour in zone refined Refilaments, while that from the normal Re-filaments was not disappeared completely and was still remained as 3 pg. of uranium as the impurities after the degassing treatment was performed for more than 5 hours at the same condition of zone refined filaments. A threshold condition eliminating impurities were proved to be at 5 A and 30 minutes of degassing time. The uranium content as an impurity in rhenium filament was checked with a filament degassing treatment using the U-233 spike by isotope dilution mass spectrometry. A 0.31 ng of U was detected in rhenium filament without degassing, while only 3 pg of U was detected with baking treatment at a current of 5.5 A for 1 hr. Using normal Re-filaments for the ultra trace of uranium sample analysis had something problem because uranium remains to be 3 pg on the filament even though degassed for long hours. If the 1 ng uranium were measured, 0.3% error occurred basically. It was also conformed that ionization filament current was recommended not to be increased over 5.5 A to reduce the background. Finally, the contents of uranium isotopes in uranium standard materials (KRISS standard material and NIST standard materials, U-005 and U-030) were measured and compared with certified values. The differences between them showed 0.04% for U-235, 2% for U-234 and 2% for U-236, respectively.

A STUDY ON THE IONOSPHERE AND THERMOSPHERE INTERACTION BASED ON NCAR-TIEGCM: DEPENDENCE OF THE INTERPLANETARY MAGNETIC FIELD (IMF) ON THE MOMENTUM FORCING IN THE HIGH-LATITUDE LOWER THERMOSPHERE (NCAR-TIEGCM을 이용한 이온권과 열권의 상호작용 연구: 행성간 자기장(IMF)에 따른 고위도 하부 열권의 운동량 강제에 대한 연구)

  • Kwak, Young-Sil;Richmond, Arthur D.;Ahn, Byung-Ho;Won, Young-In
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.2
    • /
    • pp.147-174
    • /
    • 2005
  • To understand the physical processes that control the high-latitude lower thermospheric dynamics, we quantify the forces that are mainly responsible for maintaining the high-latitude lower thermospheric wind system with the aid of the National Center for Atmospheric Research Thermosphere-Ionosphere Electrodynamics General Circulation Model (NCAR-TIEGCM). Momentum forcing is statistically analyzed in magnetic coordinates, and its behavior with respect to the magnitude and orientation of the interplanetary magnetic field (IMF) is further examined. By subtracting the values with zero IMF from those with non-zero IMF, we obtained the difference winds and forces in the high-latitude 1ower thermosphere(<180 km). They show a simple structure over the polar cap and auroral regions for positive($B_y$ > 0.8|$\overline{B}_z$ |) or negative($B_y$ < -0.8|$\overline{B}_z$|) IMF-$\overline{B}_y$ conditions, with maximum values appearing around -80$^{\circ}$ magnetic latitude. Difference winds and difference forces for negative and positive $\overline{B}_y$ have an opposite sign and similar strength each other. For positive($B_z$ > 0.3125|$\overline{B}_y$|) or negative($B_z$ < -0.3125|$\overline{B}_y$|) IMF-$\overline{B}_z$ conditions the difference winds and difference forces are noted to subauroral latitudes. Difference winds and difference forces for negative $\overline{B}_z$ have an opposite sign to positive $\overline{B}_z$ condition. Those for negative $\overline{B}_z$ are stronger than those for positive indicating that negative $\overline{B}_z$ has a stronger effect on the winds and momentum forces than does positive $\overline{B}_z$ At higher altitudes(>125 km) the primary forces that determine the variations of tile neutral winds are the pressure gradient, Coriolis and rotational Pedersen ion drag forces; however, at various locations and times significant contributions can be made by the horizontal advection force. On the other hand, at lower altitudes(108-125 km) the pressure gradient, Coriolis and non-rotational Hall ion drag forces determine the variations of the neutral winds. At lower altitudes(<108 km) it tends to generate a geostrophic motion with the balance between the pressure gradient and Coriolis forces. The northward component of IMF By-dependent average momentum forces act more significantly on the neutral motion except for the ion drag. At lower altitudes(108-425 km) for negative IMF-$\overline{B}_y$ condition the ion drag force tends to generate a warm clockwise circulation with downward vertical motion associated with the adiabatic compress heating in the polar cap region. For positive IMF-$\overline{B}_y$ condition it tends to generate a cold anticlockwise circulation with upward vertical motion associated with the adiabatic expansion cooling in the polar cap region. For negative IMF-$\overline{B}_z$ the ion drag force tends to generate a cold anticlockwise circulation with upward vertical motion in the dawn sector. For positive IMF-$\overline{B}_z$ it tends to generate a warm clockwise circulation with downward vertical motion in the dawn sector.

Prophylactic and therapeutic studies on intestinal giant-cystic disease of the Israel carp caused by Thelophanellus kitauei II. Effects of physical and chemical factors on T. kitauei spores in vitro (향어의 장포자충(Thelohanellus kitauei)증의 예방 및 치료에 관한 기초적 연구 II. 물리화학적 요인이 장포자충 포자에 미치는 영향)

  • Lee, Jae-Gu;Kim, Jong-O;Park, Bae-Geun
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.4
    • /
    • pp.241-252
    • /
    • 1990
  • In a basic attempt to develop the prophylactic and therapeutic measures on intestinal giantcystic disease of the Israel carp, C), prinks carpio nudum, the effects of physical and chemical factors on viability or survival of the spores of Thelchcnellus kiteuei were checked in vitro by means of extrusion test on the polar filament. When the fresh spores suspended with 0.45% and 0.9% scdium chloride solution and distilled water were laid at $5^{\circ}C$ and $28^{\circ}C$ for short terms, the extrusion rates increased until the 3rd day, meanwhile when son;e of them were suspended with Tyrode's solution at $-70^{\circ}C$ the rates increased gradually until the 8th day. Viabilities of the spores suspended with 0.9% saline and added antibiotics to the suspension at $5^{\circ}C$ for long terms lasted for 997 days and 1, 256 days (presumed values) at maximum, respectively. The spores suspended with distilled water at $28^{\circ}C$ for long terms survived 152.4 days, but the spores suspended with Tyrode's solution at $-70^{\circ}C$ for long terms showed almost the same viable pattern as early freezing stages up to 780 days. The spores suspended with Tyrode's solution, frozen at $-70^{\circ}C$ and thawed at $5^{\circ}C$, showed the highest rate of extrusion of the polar filament. In the case of frozen spores, the extrusion rates during heating tend to become higher in accordance with the increase of frozen period, and the critical points of 180 day-frozen spores to be killed were generally 78.5 hr. at $60^{\circ}C$, 23.4 hr. at $70^{\circ}C$, 189.1 min. at $80^{\circ}C$ or 10.5 min. at $90^{\circ}C$. The longer the spores were frozen, the more time was needed for the death of spores after thawing; 20 days-17.4 days, 100 days-33.2 days, and 400 days-37.8 days. The longer the spores were frozen, the more time was needed for the death of spores at a conventional when they were dried air drying condition, 540 days-23.5 days, 160 days-21.0 days, and 20 days-14.4 days. On the other hand, the longer the spores were frozen, the more spores were dead rapidly when they were irradiated with 10W UV-ray; 100 days-26.0 hr, 300 days-21.9 hr, and 540 days-13.9 hr. The time needed for killing 200 days-frozen spores by various disinfectants at 1, 000 ppd was 5.2 min. by calcium oxide, 10.4 min. by potassium permanganate, 27.8 min. by malachite green and 14.3 hr. by formalin. Transient inhibitory effects of the extrusion of the polar filament were observed by various antiprotozoal and antifungal agents in the descending order of ketoconazole. metronidasole and dapsone. The above results presume that full drying, followed by spraying CaO and maintaining sunny condition for a few days on the concrete bottoms of knish farm may be an effective method for the prevention of intestinal giant.cystic disease.

  • PDF

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.