• Title/Summary/Keyword: Heating Characteristics

Search Result 2,423, Processing Time 0.032 seconds

A Study on Treatment of a Contaminated Soil by Oil using Continuous System of High Temperature Heating Element and Microwave (마이크로웨이브와 고온발열체를 이용한 연속식 공정의 유류오염토양 처리에 관한 연구)

  • Ha, Sang-An;You, Mi-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.1
    • /
    • pp.8-12
    • /
    • 2012
  • This study is maintains the condition of high temperature (above $600^{\circ}C$) within a short time using on microwave and high temperature heating elements. And removal characteristics according to changes in soil moisture, microwave power and temperature through the decomposition of the contaminated soil by oil. The difficulty resolvability material was sort of lubricating oil having long carbocyclic (C18-C50) and TPH removal rate reached 85.2% at 6 kW and $700^{\circ}C$ and thus the contaminant was removed 1,788 mg/kg within a process time of 40 minutes. In the case of light oil, gasoline contaminated soil, the removal amount showed 567 mg/kg and the treatment rate reached 98.4% at 6 kW, $500^{\circ}C$ and 20 minute. In the case of non-resolvability reached TPH concentrations on 2,000 mg/kg of worrisome level of soil contamination in the 3 zones at 6 kW, $700^{\circ}C$ and 30 minute. At the time, showed up processing costs 8,173 won per ton.

The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact (전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성)

  • Kim, Wansu;Park, SangJune;Hwang, DongHyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter (겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가)

  • Lee, Hyun-Hwa;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.99-106
    • /
    • 2017
  • Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

The Mixing Effect of Methanol and Ethanol in Lard and Soybean Oil Based Biodiesel Production (돈지와 대두유를 이용한 바이오디젤 제조에서 메탄올과 에탄올의 혼합효과)

  • Lee, Seung Bum;Kim, Hyungjin
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.515-519
    • /
    • 2014
  • The fuel properties of biodiesel produced by changing the mixing ratio of methanol and ethanol in trans-esterification of soybean oil and lard were evaluated in this paper. The solubility of oil and fat in ethanol was higher than that in methanol. Also the more homogeneous biodiesel was produced as increasing the mole ratio of ethanol. The conversion characteristics of lard was the best at the mixing mole ratio of methanol and ethanol was 6 : 6 at the reaction temperature of $60^{\circ}C$. On the other hands, the best biodiesel conversion characteristics for soybean oil was obtained at the mixing mole ratio of 3 : 3. The kinematic viscosities of soybean oil and lard based biodiesel were 4.17~4.35 cSt and 4.69~4.93 cSt, respectively. The oxidation stability and higher heating value increased with increasing the mole ratio of ethanol. The oxidation stability satisfied the criteria of biodiesel quality of 6 hours. And finally, the higher heating value was approximately 40 MJ/kg.

A 15 nm Ultra-thin Body SOI CMOS Device with Double Raised Source/Drain for 90 nm Analog Applications

  • Park, Chang-Hyun;Oh, Myung-Hwan;Kang, Hee-Sung;Kang, Ho-Kyu
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.575-582
    • /
    • 2004
  • Fully-depleted silicon-on-insulator (FD-SOI) devices with a 15 nm SOI layer thickness and 60 nm gate lengths for analog applications have been investigated. The Si selective epitaxial growth (SEG) process was well optimized. Both the single- raised (SR) and double-raised (DR) source/drain (S/D) processes have been studied to reduce parasitic series resistance and improve device performance. For the DR S/D process, the saturation currents of both NMOS and PMOS are improved by 8 and 18%, respectively, compared with the SR S/D process. The self-heating effect is evaluated for both body contact and body floating SOI devices. The body contact transistor shows a reduced self-heating ratio, compared with the body floating transistor. The static noise margin of an SOI device with a $1.1\;{\mu}m^2$ 6T-SRAM cell is 190 mV, and the ring oscillator speed is improved by 25 % compared with bulk devices. The DR S/D process shows a higher open loop voltage gain than the SR S/D process. A 15 nm ultra-thin body (UTB) SOI device with a DR S/D process shows the same level of noise characteristics at both the body contact and body floating transistors. Also, we observed that noise characteristics of a 15 nm UTB SOI device are comparable to those of bulk Si devices.

  • PDF

Effects of Flight Conditions on IR Signature from Aircraft Exhaust Plume (비행조건에 따른 항공기 배기플룸의 IR 신호 특성)

  • Go, Gun-Yung;Kim, Man-Young;Baek, Seung-Wook
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.5
    • /
    • pp.58-66
    • /
    • 2012
  • The IR signature and radiative base heating from an aircraft plume have been important factors for aircraft survivability in modern battle fields. In order to enhance the aircraft survivability and reduce the base heating, infrared signatures emitted from an aircraft exhaust plume should be determined. In this work, therefore, IR signatures and radiative base heating characteristics are examined in the plume exhausted from the aircraft with operating at altitude of 5 km in M=0.9 and 1.6, respectively. As a result, it is found that the particular wavelength IR signature has high spectral characteristics because of $H_2O$ and $CO_2$ gases in the plume, and the radiative heat flux coming into the base plane increases with higher Mach number and shorter distance.

A Study on the Energy Consumption Characteristics for Use and Operation Period in Office Buildings (업무용 건물의 용도 및 운전 기간별 에너지 소비 특성 연구)

  • Park, Byung Hun;Kim, Si Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.605-611
    • /
    • 2017
  • The purpose of this study is to calculate the energy consumption rate based on data regarding energy use in office buildings, and to confirm the general characteristics of energy consumption. The energy consumption rate of the building is calculated by dividing the energy consumption by the floor area. The energy consumption rate of small-sized office buildings was calculated as $101.48{\sim}201.55kWh/m^2{\cdot}year$ and in the case of medium-sized buildings, the range was $92.77{\sim}177.89kWh/m^2{\cdot}year$. In the case of small buildings, it was found that the energy consumption was $73.24kWh/m^2{\cdot}year$ in electronic device, $34.31kWh/m^2{\cdot}year$ in hot water supply, and $18.37kWh/m^2{\cdot}year$ in heating. In the case of medium-sized buildings, electronic devices was $73.08kWh/m^2{\cdot}year$, lighting was $18.35kWh/m^2{\cdot}year$ and heating, $15.37kWh/m^2{\cdot}year$. In all of the study buildings, the peak heating energy use was observed from 8:00 a.m. to 10:00 a.m during the winter, and the peak power management was required. Energy use at and around the midnight hour is confirmed to be 40~60% of weekly working hours, so it is necessary to manage power use at night time as well as during the day. In order to improve the accuracy of future studies, it is necessary to make efforts to secure the data with standardized energy measuring units for the various type of buildings.

Analysis on the Characteristics of Energy Use Behaviors and Energy Saving Consciousness of Multi-family Housing Residents (공동주택 거주자의 에너지 사용행태 및 에너지 절약의식 분석)

  • Lee, Youn-Jae;Lee, Hyun-Soo;Park, So-Yun
    • Journal of the Korean housing association
    • /
    • v.22 no.6
    • /
    • pp.31-42
    • /
    • 2011
  • The purpose of the study was to investigate the characteristics of energy use behaviors and energy saving consciousness of multi-family housing residents. The energy referred to in this study includes electric energy, heating energy and water usage. This study was conducted from a survey carried out in Seoul and Gyeonggi-do. The results of the study are as follows: First, among the survey questions, the only positive energy saving behaviors shown by the occupants was turning off the lights and the television, and in the use of kitchen appliances; it could therefore be concluded that, in general, energy saving attitude and consciousness were not sufficient to reduce energy consumption. Second, the results showed high mean scores for the behaviors which were easy to control, such as turning off lights and televisions, and low mean scores for the behaviors which required extra effort to completely cut off electricity energy such as pulling out the plugs of electronic appliances. Third, it was found that the occupants generally showed the tendency to save heating energy. However, in cases where the occupants were required to continuously and directly experience indoor temperatures, they expressed passive attitudes toward saving energy. Fourth, they showed wasteful attitudes toward water usage by leaving the tap running when taking showers and washing their faces. Fifth, while they showed a strong energy saving consciousness, they also showed a passive attitude about putting this into practice; there was therefore some gap between attitude and behavior. Lastly, among the socio-demographic factors, age and family lifecycle were very important factors affecting energy use and energy saving consciousness.

A Study on the Heat Sink with internal structure using Peltier Module in the Forced Convection (강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구)

  • Lee, Min;Kim, Tae-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3410-3415
    • /
    • 2014
  • The heat generated by electronic devices can result in performance degradation. Therefore, a heat sink has been used to release the operating heat into the air outside. This study addressed a methodology for a heat sink with an inner tunnel. Under forced convection conditions, the heat transfer characteristics were different so the cooling and heating performances were studied for the heat sink with an inner tunnel. This was evaluated by performing the experimental test examining the heat transfer characteristics related to the variance in time and temperature distribution. In the cooling experiment, the temperature of the A-shape was lower than that of the B-shape, when the voltage was 10 V. These experimental results indicate the optimal cooling effect. In a heating experiment, the temperature of the A-shape was higher than that of the B-shape, when the voltage was 13 V. The experimental results showed that the temperature and efficiency of the A-shape were higher than those of the B-shape.