An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

An Experimental Study on the Heating Characteristics of HVAC Systems for Shopping Center in Underground Passage (지하도 상가 냉난방.환기 시스템의 난방운전 특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju;Kim, Tae-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2989-2994
    • /
    • 2008
  • The shopping center in underground passage for efficient space utilization is increased in urban area. This study describes operation characteristics of HVAC systems with ventilation and individual heating and cooling unit for shopping center in underground passage. In order to compare energy saving, thermal environment and installation space, etc., an integrated simulator with heat production and distribution system was designed and constructed. Energy delivery efficiency is improved over 20%, and energy saving of the hybrid system is calculated as over 30% compared to conventional all air type in the case of heating. And also the results showed that humidity decreased about $5{\sim}6%$, also characteristics of thermal control is improved over 34%.

  • PDF

A Study on the Furnace Heating Characteristics Using Oxy-fuel Combustion (순산소 연소를 이용한 연소로 가열특성에 관한 실험적 연구)

  • Jeong, Yu-Seok;Lee, Eun-Kyung;Ko, Chang-Bok;Noh, Dong-Soon;Jang, Byung-Lok;Han, Hyung-Kee
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.229-234
    • /
    • 2006
  • The oxy-fuel combustion heating characteristics is investigated experimentally by measuring furnace and steel temperature variations for batch type furnace simulator with a specially designed low NOx oxy-fuel burner. Economics of using oxy-fuel combustion is confirmed and, the furnace and steel temperature variations for different heating conditions are compared to deduce optimal heating control pattern for energy savings and rapid uniform heating. High $CO_2$ concentration (> 80-90%), low NOx (< 40ppm) and CO (< 10ppm) are measured in the flue gas. Temperature differences (< $30^{circ}C$) inside the furnace and steel are reduced relatively by increasing the burner jet momentum.

  • PDF

A Study on the Thermal and Electrical Characteristics with Manufacture of the Heating Element by Using Carbon with Bar Type (봉상 카본 발열체의 제조와 열 및 전기적 특성에 관한 연구)

  • 배강열;이광성;정한식;정희택;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.430-437
    • /
    • 2004
  • This paper is intended as an investigation of study on the thermal and electrical characteristics of the carbon heating element. In this experimentation, the electric material used is the crystalline graphite a kind of natural graphite. The bentonite is used to solidify the heating element and the vacuum furnace is used for sintering it. It is noted that the natural drying time should be at least 58 hours. The plating of the electric pole with the electroless nickel showed the lowest contact resistance among others. The resistance shows linear variation with regard to length. For the insulation and resolution, the glaze coating is best with 80% of water content. The temperature rising characteristic of the heating element is better than sheath heater saving 43% of rising time. The correlation equation for temperature was obtained with the electric power.

The Characteristics and Heating Values Analysis of Municipal Solid Wastes according (쓰레기종량제에 따른 쓰레기의 특성 및 발열양 분석)

  • 문추조;정순형;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.29-34
    • /
    • 1995
  • This study was on the characteristics and heating values analysis of municipal solid wastes according to the volume- rate garbage collection system in Busan. Each waste sample was analyzed to obtain physical composition, proximate analysis, heating value, chemical composition. And the heating value were compared with those of the past waste collection system. The average physical composition of A.P.T. area was food waste 54.0~65.7% , while that of common residence was food waste 57.9~61.2% . The density of solid waste were largely different for site and the highest densities of waste was $399.6kg/m^{3}$ from Market. The low heating value of waste from residence site was 996.9kca1/kg~1, 238.1 kcal/kg which was lower than 1, 000kcal/kg~1, 800kca1/kg of the past wastes. These difference was mainly due to the difference of moisture content and the amount of vegetables.

  • PDF

Three-Dimensional Analysis of Self-Heating Effects in SOI Device (SOI 소자 셀프-히팅 효과의 3차원적 해석)

  • 이준하;이흥주
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.4
    • /
    • pp.29-32
    • /
    • 2004
  • Fully depleted Silicon-on-Insulator (FD-SOI) devices lead to better electrical characteristics than bulk CMOS devices. However, the presence of a thin top silicon layer and a buried SiO2 layer causes self-heating due to the low thermal conductivity of the buried oxide. The electrical characteristics of FDSOI devices strongly depend on the path of heat dissipation. In this paper, we present a new three-dimensional (3-D) analysis technique for the self-heating effect of the finger-type and bar-type transistors. The 3-D analysis results show that the drain current of the finger-type transistor is 14.7% smaller than that of the bar-type transistor due to the 3-D self-heating effect. We have learned that the rate of current degradation increases significantly when the width of a transistor is smaller that a critical value in a finger-type layout. The current degradation fro the 3-D structures of the finger-type and bar-type transistors is investigated and the design issues are also discussed.

  • PDF

A Study on Heating Characteristics of Ground Source Heat Pump with Variation of Heat Exchange Methods (열교환방식에 따른 지열히트펌프의 난방특성에 관한 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung;Park, Cha-Sik
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.2
    • /
    • pp.9-15
    • /
    • 2012
  • The objective of this study is to investigate the influence on the heating performance for a water-to-water 10RT ground source heat pump by using the water switching and refrigerant switching method. The test of water-to-water ground source heat pump was measured by varying the compressor speed, load side inlet temperature, and ground heat source side temperature. The heating capacity and COP of the heat pump increased with increasing ground heat source temperature. As a result, compared to a refrigerant switching method, the water switching method with counter flow improves the heating capacity and COP by approximately 5% in average, respectively.

A Study on the Heat Transfer Characteristics of Heating Unit in DPH HVAC (수송용 DPH HVAC 히팅유니트장치의 열유동 시뮤레이션평가연구)

  • Roh, Hong-Koo;Lim, Kyung-Bin;Noh, Jong-Ho;Lee, Young-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.605-610
    • /
    • 2008
  • The study aims to analyzed and identify the heat transfer characteristics of heating unit for room using 3-D numerical-analysis in order to design heating unit. The temperature comparison processes were done with various numerical conditions. In addition, the optimal conditions of heating unit design were proposed as inlet temperature, the inlet flow, heater power, and vessel size.

  • PDF

Heat generation characteristics of the heating mortar according to repeated electricity supply (반복전기공급에 따른 발열모르타르의 발열 특성)

  • Kim, Young-Min;Lim, Chang-Min;Gwon, Hyeon-U;Lee, Gun-cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.170-171
    • /
    • 2022
  • In recent years, due to the occurrence of traffic accidents caused by black ice in winter, the number of personal injuries is increasing rapidly. Black ice is a phenomenon that occurs like a thin layer of ice on the road surface. Accordingly, many developments of heat-generating concrete are being developed to remove ice by increasing the temperature by supplying constant electricity to places where black ice is likely to occur. These heating elements are being developed by mixing a conductive material represented by carbon nanotubes with concrete. However, research up to now has been focused on efficient temperature rise and derivation of the optimum mixing ratio, and the evaluation of maintaining heat generation performance during continuous repetition is insufficient. Therefore, in this study, a heating test specimen was manufactured and 50V power was repeatedly supplied to evaluate the heating characteristics.

  • PDF

Survey on the Uses of Heating-Cooling Facilitis.Accessory Devices and Residents' Evaluation in Cheju Province (제주도 지역 냉난방 설비.보조기구 사용실태와 거주자의 평가)

  • 김봉애
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.5
    • /
    • pp.239-248
    • /
    • 1997
  • to design nature-affinitive, reasonable and effcient thermal environment plannings and facilities, the holding patterns of heating-cooling facilities·accessory devices and residents' evaluation in Cheju Province were surveyed as well as residents' understanding for them. Major findings of this study are summarized as follows: 1) In the cooling system, the percentage of air-conditioner possessor was 19.4%, which was lower possessive rate than mainland's. The location of air-conditioner was mainly public area. That is, 55.3% of the location is livingroom, and the rest was Anbang. the general cooling accessory device was a fan. It was frequently used at the children's room and the dining room. The possessive patterns of air-conditioner depend on the characteristics of residents, such as the academic carrier and the average monthly income. Characteristics of house for air-conditioner possess depend on the location, house type, the size of floor space. 2) In the heating system, individual heating system reached to 57.3%. Heating accessory devices were oil stove and electric heating blanket. Only 32.2% of survey population were holders. 3) Residents preferred better ventilated room arrangement, which was characteristic of subtropical areas. 4) The preferred condition for heating-cooling facilities and accessory devices were strong solidity, less air pollution, and less noise.