• Title/Summary/Keyword: Heating Characteristics

Search Result 2,423, Processing Time 0.027 seconds

Characteristics of ($AI_2$ $O_3$40%$YiO_2$)NiCr thermal sprayed composite coatings (($AI_2$ $O_3$40%$YiO_2$)NiCr 복합용사피막의 특성)

  • 김경호;박경채;김태형
    • Proceedings of the KWS Conference
    • /
    • 2003.05a
    • /
    • pp.114-116
    • /
    • 2003
  • The multi function sprayed coating is used for direct-heating, wear resistance and high bonding strength. The merits of surface direct-heating coatings are short warming time, low power consumption and better wear resistance that can be used in many organization parts. In this study, the surface direct-heating and wear resistance can be improved by spraying the proper materials on the surface $Al_2$O$_3$40%TiO$_2$ powder and Ni-20%Cr powder that had the properties of conduction and high wear resistivity are used in order to improve wear resistance, electrical properties and bonding strength.

  • PDF

Wood pelletizing using pine root waste biomass - different pelletizing properties between trunk and root biomass of Pinus densiflora (소나무 뿌리 폐기물을 이용한 목질 펠릿 제조 - 목부와 뿌리로 제조한 펠릿의 특성 비교)

  • Shin, Soo-Jeong;Han, Gyu-Seong;Myeong, Soo-Jeong;Cho, Jung-Sik;Yeon, Ik-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.71-73
    • /
    • 2008
  • Different biosolid fuel (wood pellet) properties between trunk and root of pine (Pinus densiflora) biomass were investigated. Trunk has more organic solvent extracts and Klason lignin content which has higher heating values than root biomass component. In root biomass, polysaccharides content was higher than trunk biomass. Based on Higher Heating Value (HHD) analysis and ash content, trunk biomass showed better solid fuel characteristics than root biomass. But pine root biomass had lower HHD than trunk biomass, its HHD values were higher than other hardwood or annual plant lignocellulosic biomass.

  • PDF

Heating type of die surface for removing weld line using high temperature air jet (웰드라인 제거를 위한 고온 기체 분사를 이용한 금형 표면의 가열기법)

  • Kim, Gyeong-Ha;Kim, Sun-Gyeong;Yu, Yeong-Eun;Jea, Tae-Jin;Choi, Du-Seon
    • Design & Manufacturing
    • /
    • v.2 no.2
    • /
    • pp.10-14
    • /
    • 2008
  • The application range of injection molded parts is expanding by the development of engineering plastics with good mechanical properties. Plastic products are specially used as automotive parts due to an excellent performance in the characteristics of a strength vs. weight. In this study, heating type of new method such as jet injection was applied to improve heat transfer coefficient is substituted for heating method of injection molding.

  • PDF

A Study on the Characteristics of Thermal Environment and Improvement of Energy Performance in 5ESS-2000 Telecommunication Equipment Room (5ESS-2000 통신장비실의 열환경특성과에너지성능 개선방안에 관한 연구)

  • Leigh, Seung-Bok;Cho, Chun-Sik
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.19-26
    • /
    • 2004
  • The purpose of this study was to evaluate the thermal environment of present state and energy consumption and to verify the improvement of energy performance applying free cooling in 5ESS-2000 telecommunication equipment room. Analysis program is used the DOE-2.1E and commercial CFD code, Star-CD. The results of the simulation show that free cooling could reduce 42.1% of cooling energy, increase 48.5% of heating energy because introduced outdoor air must heating and humidification. Therefore free cooling could reduce yearly 34,609.9 kWh of heating and cooling energy and this is reaching to 21.6% of total energy.

Thermal Performance of Flat-strip Heat Pipe with Various Heat Source Locations (열원의 위치에 따른 평판형 히트파이프의 열적 성능)

  • Park, S.Y.;Boo, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1406-1411
    • /
    • 2004
  • A series of experiments was conducted to examine characteristics of a grooved flat-strip heat pipe having multiple heat sources. The inner grooves of the heat pipe have the aspect ratio of 1 to $2.5(0.42{\times}1.05$ mm) whose pitch was 0.6 mm. Four block heaters ($10{\times}20$ mm) were placed in the evaporator section at intervals of 20 mm and six different heating modes were tested. The maximum surface heat flux of 80 $W/cm^2$ was achieved while the operating temperature was kept below $100^{\circ}C$, In the nearest heating mode (from the condenser location), the heat pipe exhibited more stable temperature distribution than the far heating mode where the heaters is located furthest from the condenser.

  • PDF

A Study on the Performance Analysis of Proportional Automatic Thermostatic Valves in Floor Radiant Heating System (바닥난방 시스템용 비례식 자동온도조절밸브의 성능해석에 관한 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.52-57
    • /
    • 2007
  • The control characteristics for radiant panel heating system with automatic thermostatic valves were researched by computer simulation and experiment. The unsteady energy analysis using equivalent R-C circuit method and radiation heat transfer analysis of enclosure analysis method with simple structured rooms was performed. The results of flow rate changes of the simulation study are good fit with the ones of experimental one.

  • PDF

The Comparison of Maintenance Cost and Residents′Consciousness of Remodeling by Rental Apartment Types (임대아파트 유형별 유지관리비와 거주자의 리모델링 의식비교)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.14 no.4
    • /
    • pp.69-76
    • /
    • 2003
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the characteristics of maintenance cost and the residents'consciousness of remodeling by rental apartment types. The results of this study were as follows; The annual maintenance cost of permanent rental apartment was 14,249 won/$\textrm{m}^2$$.$yr, that of fifty years period rental apartment was 13,372 won/$\textrm{m}^2$$.$yr. In the case of remodeling in deteriorated heating system, the principal decision factor of choice was showed “economics” as priority. Residents in rental apartment preferred remodeling to reconstruction, and unit heating system to central heating system.

A New Hybird Control Scheme Using Active-Clamped Class-E Inverter with Induction Heating Jar for High Power Applications

  • Lee, Dong-Yun;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.104-111
    • /
    • 2002
  • This paper presents a new hybrid control scheme using Active-Clamped Class-E(ACCE) inverter for the Induction Heating (IH) jar. The proposed hybrid control scheme has characteristics, which acts as class-E inverter at lower switch voltage and ACCE inverter at higher switch voltage than reference voltage of the main switch by feeding back voltage of the switch. The proposedv hybrid control scheme also has advantage of conventional ACCE inverter such as Zero-Voltage-Switch(ZVS) of the main switch and the reduced switch voltage due to clamping cricuit. Moreover, the proposed hybrid control method using ACCE inverter has higher output power than convenional control scheme since ACCE inverter operates like class-E inverter at low input voltage condition. The principles of the proposed control are explained in detail and the validity of the proposed control scheme is verifed through the several interesting simulated and experimental results.

Development of the Electronic Moxibustion Device for Realizing the Heating Effect of the Moxa Cautery

  • Kim, Tae-Gon;Lee, Yu-Mi;Park, Yong-Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.28-31
    • /
    • 2014
  • This study aims to develop an electronic moxibustion device for the quantification of moxibustion, which progresses a critical role in traditional oriental medicine as well as to assess the characteristics of heating. The assessment revealed that the proposed electronic moxibustion treatment device can reduce the time required for reaching the desired heat level and continue to provide heat consistently. Moreover, heat transmitted to the treated area was found to correspond to a heating pattern of the proposed electronic moxibustion device. It proved both quantitative control and safe treatment for the proposed electronic moxibustion device.

Evaluation of self-heating propensity and its relation with fuel properties of various coals (다양한 탄종별 자체발열 특성과 물성의 비교 분석)

  • Kim, Jungsoo;Lee, Yongwoon;Im, Hyeon Soo;Park, Hoyoung;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.83-85
    • /
    • 2013
  • With an increase in the use of low rank coals in power plants, various operational issues were raised in the fuel storage and supply, combustion, boiler and flue gas treatment systems. In the fuel storage and supply system, the main issue is the self-heating propensity of low rank coals leading to spontaneous combustion in yard storage, transport and pulverization. This study evaluated the reactivity of various sub-bituminous and bituminous coals with oxygen at low temperatures by analyzing the temperature increase characteristics of coals under a constant flow rate of oxygen supply. The results were quantified to a self-heating index and the relation with the fuel properties were evaluated.

  • PDF