• 제목/요약/키워드: Heater array

검색결과 50건 처리시간 0.024초

온도차를 이용한 유도형 마이크로 EHD 펌프의 제작 및 실험 (A Fabrication and Experiment of Induction-type EHD Micropump with Temperature Gradient)

  • 윤용규;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.198-200
    • /
    • 1993
  • This paper represents the experimental results of electrohrdrodynamic(EHD) micropump driven by traveling- wave voltage. We fabricated 60 electrodes array with $100{\mu}m$ width and $100{\mu}m$ interval on the pyrex glass. On that glass we fabricated the micro channel which had the cross section of 3mm by 0.5mm. This pump was driven by 6 phase square traveling-wave voltage. We used the corn oil for experiments and increased the temperature of fluid by resistive heater. An optical microscope with CCD camera and monitor was used for observation. The fluid velocity was large for the large driving voltage and the high temperature. This EHD pump had the fluid velocity in specific frequency (near 1Hz) which had relation to the charge relaxation time in that oil.

  • PDF

COMS 특별세션 (THERMAL CONTROL DESIGN FOR COMS)

  • Jun, Hyoung-Yoll;Kim, Jung-Hoon;Kim, Sung-Hoon;Yang, Koon-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.199-202
    • /
    • 2007
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean observation and meteorological observation. Conventional thermal control design, using MLI (Multi Layer Insulation), OSR (Optical Solar Reflector), heater and heat pipe, is utilized. Ka-band components are installed on South wall, while other equipment for sensors are installed on the opposite side, North wall. High dissipating communication units are located on external (surface) heat pipe and are covered by internal insulation blankets to decouple them from the rest of the satellite. External satellite walls are covered by MLI or OSR for insulation from space and for rejection internal heat to space. The ocean and meteorological sensors are installed on optical benches on the top floor to decouple thermally from the satellite. Single solar array wing is adopted in order to secure clear field of view of radiant cooler of IR meteorological sensor. This paper presents principles of thermal control design for the COMS.

  • PDF

풀비등과 저Re수 흐름비등에서의 기포의 형상과 성장에 대한 연구 (Study on the Relationships between Single Bubble Growth Behavior and Bubble Shape Assumption in Pool and low-He Flow Boiling)

  • 김정배
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.73-82
    • /
    • 2009
  • 포화상태 핵비등과 저 Re수의 흐름비등에서 얻어진 실험결과를 바탕으로 하여, 기포가 성장하는 동안의 등가 기포 직경과 열전단율의 거동에 대한 기포 형상 가정의 효과를 제시하기 위한 해석적인 연구를 수행하였다. 이러한 목적을 달성하기 위하여, 등가 기포 반경이 기포가 성장하는 동안 촬영된 기포의 이미지로부터 얻어질 수 있는 형상 가정을 이용하여 계산되었다. 그리고 열전달율을 포화상태 핵비등 동안 미세크기의 히터와 휘스톤브리지 회로를 이용하여 측정하였다. 그리고, 기포 형상 가정의 효과를 실험결과와 비교하였고, 이를 통해 단일 기포의 성장 거동을 분석하기 위한 기포 형상 가정이 매우 중요함을 보였다.

포화상태 풀비등시 단일기포의 성장에 관한 연구 (Study on the Single Bubble Growth During Nucleate Boiling at Saturated Pool)

  • 김정배;이한춘;오병도;김무환
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.169-179
    • /
    • 2005
  • Nucleate boiling experiments on heating surface of constant wall temperature were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition of heating surface and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous experimental results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later (thermal) respectively. The comparisons showed good agreement in the initial and thermal growth regions. In the initial growth region including surface tension controlled, transition and inertia controlled regions as divided by Robinson and Judd, the bubble growth rate showed that the bubble radius was proportional to $t^{2/3}$ regardless of working fluids and heating conditions. And in the thermal growth region as also called asymptotic region, the bubble showed a growth rate that was proportional to $t^{1/5}$, also. Those growth rates were slower than the growth rates proposed in previous analytical analyses. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool condition. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

포화상태 풀비등시 단일기포의 성장에 관한 연구 (Study on the single bubble growth at saturated pool boiling)

  • 김정배;이한춘;오병도;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1933-1938
    • /
    • 2004
  • Nucleate boiling experiments with constant wall temperature of heating surface were performed using R113 for almost saturated pool boiling conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain a constant wall temperature condition and to measure the heat flow rate with high temporal and spatial resolutions. Bubble images during the bubble growth were taken as 5000 frames a sec using a high-speed CCD camera synchronized with the heat flow rate measurements. The geometry of the bubble during growth time could be obtained from the captured bubble images. The bubble growth behavior was analyzed using the new dimensionless parameters for each growth regions to permit comparisons with previous results at the same scale. We found that the new dimensionless parameters can describe the whole growth region as initial and later respectively. The comparisons showed good agreement in the initial and thermal growth regions. The required heat flow rate for the volume change of the observed bubble was estimated to be larger than the instantaneous heat flow rate measured at the wall. Heat, which is different from the instantaneous heat supplied through the heating wall, can be estimated as being transferred through the interface between bubble and liquid even with saturated pool conditions. This phenomenon under a saturated pool condition needs to be analyzed and the data from this study can supply the good experimental data with the precise boundary condition (constant wall temperature).

  • PDF

축전지 사용 유무에 따른 태양광발전기의 성능 분석 (Performance Analysis of Photovoltaic Power Generator by Usage Battery Charge)

  • 윤성욱;최만권;김현태;윤용철
    • 생물환경조절학회지
    • /
    • 제22권3호
    • /
    • pp.220-227
    • /
    • 2013
  • 본 연구는 온실 운영에 필요한 전력량을 확보함으로서 온실경영비 절감을 목적으로 태양광발전시스템을 온실에 인접한 건물의 옥상에 설치하여 일사량에 따른 발전량을 실험적으로 검토하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 수평면 일사량의 최대, 평균 및 최소값은 각각 $26.1MJ{\cdot}m^{-2}$, $14.0MJ{\cdot}m^{-2}$$0.6MJ{\cdot}m^{-2}$ 정도였고, 일일 전력량은 각각 약 6.1kWh, 3.7kWh 및 0.01kWh 이었다. 그리고 누계 일사량과 전력량은 각각 약 $4,378.2MJ{\cdot}m^{-2}$ 및 1,163.2kWh 정도이었다. 그리고 부하에 의해 소비된 적산전력량의 최대, 평균 및 최소값은 각각 4.5kWh, 2.4kWh 및 0.0kWh 정도이었고, 누계전력량은 739.2kWh 정도로서 발생 전력량의 약 63.5%에 해당하였다. 본 실험에 사용된 시스템의 평균 소비전력량을 기준으로 보면, 온풍기의 용량 및 작동시간이 작은 경우는 충분하지만 큰 경우는 부족한 것으로 나타났다. 어레이 표면온도가 상대적으로 높아지면 일사량에 비례해서 발생 전력이 증가하지 않은 것으로 나타났지만, 두 인자 간에 상관계수는 0.851 정도로서 상관관계가 높은 것으로 나타났다.

평면형 다중접합 열전변환기의 제작 (Fabrication of Planar Multi-junction Thermal Converter)

  • 권성원;박세일;조용명;강전홍
    • 센서학회지
    • /
    • 제5권4호
    • /
    • pp.17-24
    • /
    • 1996
  • 교류-직류 변환방법으로 교류전압 및 전류를 정밀측정하기 위한 평면형 다중접합 열전변환기를 제작하였다. 실리콘 기판에 지지된 $Si_{3}N_{4}$ (200 nm) / $SiO_{2}$ (400 nm) / $Si_{3}N_{4}$ (200 nm) 샌드위치구조의 두께 $0.8\;{\mu}m$ (크기 $2{\times}4\;mm^{2}$)의 멤브레인 위에 가열선과 열전대 접합을 형성하였다. 멤브레인의 세로방향 중앙에 NiCr 가열선을 배치하고, 가열선 주위 또는 그 위에 동-콘스탄탄(Cu- CuNi44)으로 $48{\sim}156$ 개의 열전대의 열(熱)접합을 형성하였으며, 열전대의 냉(冷)접합은 실리콘 기판 위에 형성하였다. 직류 10 mA의 입력에 대한 열전대의 출력전압은 종류에 따라 $76\;mV{\sim}382\;mV$를 얻었으며, 입력 5 mA일때 출력전압의 단기안정도는 ${\pm}5{\sim}15\;ppm4/ 10 min이었다. 공기분위기에서 감응도는 $3.9{\sim}14.5V/W$로 측정되었고, 열전대의 수가 48개인 모델 BF48의 경우 공기중에서의 감응도가 3.9 V/W로써, 56개의 열전대를 갖는 3차원구조 다중접합 열전변환기의 진공분위기에서의 감응도보다 2배 이상 크게 나타났다. 또한 측정전류 10 mA 이하, 측정주파수 $5\;Hz{\sim}2\;kHz$에서의 교류-직류 변환차이는 약 ${\pm}1\;ppm$ 이하이었고, 5 kHz 및 10 kHz에서는 약 $2{\sim}3\;ppm$ 이었다.

  • PDF

안테나 결합형 볼로미터 방식 테라헤르츠 센서를 이용한 이차원 주사 방식의 투과형 테라헤르츠 영상 취득에 관한 연구 (Terahertz Transmission Imaging with Antenna-Coupled Bolometer Sensor)

  • 이경일;임병직;원종석;홍성민;박재현;이대성
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.311-316
    • /
    • 2018
  • An antenna-coupled bolometer-type terahertz sensor was designed, fabricated, evaluated, and utilized to obtain terahertz transmission images. The sensor consists of a thin film bowtie antenna that resonates accordingly in response to an incident terahertz beam, a heater that converts the applied current in the antenna into heat, and a microbolometer that converts the rise in temperature into a change in resistance. The device is fabricated by a bulk micromachining process on a 4-inch silicon wafer. The fabricated sensor chip has a size of $2{\times}2mm$ and an active area of $0.1{\times}0.1mm^2$. The temperature coefficient of resistance (TCR) of the bolometer film (VOx) is 2.0%, which is acceptable for bolometer applications. The output sensor signal is proportional to the power of the incident terahertz beam. Transmission images were obtained with a 2-axis scanning imaging system that contained the sensor. The small active area of the sensor will enable the development of highly sensitive focal plane array sensors in terahertz imaging cameras in the future.

열전달 계수 최대화를 위한 마이크로 증발기의 최적 설계 (Optimal design of a micro evaporator to maximize heat transfer coefficient)

  • 성태종;오대식;서태원;김종원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2097-2101
    • /
    • 2007
  • This paper presents an optimal design of a micro evaporator which maximizes the heat transfer coefficient. Number of gaps, spanwise distance and streamwise distance are selected as the geometric design parameters. Mass flow rate of the refrigerant is selected as the non-geometric design parameter. Temperature at the surface of the heater is measured to valuate the heat transfer coefficient. Nine experiments are conducted using $L_9(3^4)$ orthogonal array. Maximum heat transfer coefficient is 640 W/$m^2K$ at the parameters of 2 gaps, 0.2 mm spanwise distance, 1.0 mm streamwise distance and 0.72 g/s mass flow rate. Among the 3 geometric parameters, the spanwise distance is the most sensitive parameter influencing the heat transfer coefficient. We conduct a second stage of experiment to increase the heat transfer coefficient by reselecting the mass flow rate. We concluded that 0.87 g/s is the optimized flow rate for an active micro cooler resulting in a heat transfer coefficient of 651 W/$m^2K$.

  • PDF

통신해양기상위성의 전이궤도 열해석 (TRANSFER ORBIT THERMAL ANALYSIS FOR COMS)

  • 전형열;김정훈;김성훈;양군호
    • 한국전산유체공학회지
    • /
    • 제13권2호
    • /
    • pp.48-54
    • /
    • 2008
  • COMS (Communication, Ocean and Meteorological Satellite) is a geostationary satellite and has been developing by KARI for communication, ocean and meteorological observations. It will be launched by ARIANE 5. Ka-band components are installed on South panel, where single solar array wing is mounted. Radiators, embedded heat pipes, external heat pipe, insulation blankets and heaters are utilized for the thermal control of the satellite. The Ka-band payload section is divided several areas based on unit operating temperature in order to optimize radiator area and maximize heat rejection capability. Other equipment for sensors and bus are installed on North panel. The ocean and meteorological sensors are installed on optical benches on the top floor to decouple thermally from the satellite. During the transfer orbit operation, satellite will be under severe thermal environments due to low dissipation of components, satellite attitudes and LAE(Liquid Apogee Engine) firing. This paper presents temperature and heater power prediction and validation of thermal control design during transfer orbit operation.