• Title/Summary/Keyword: Heated surface

검색결과 650건 처리시간 0.027초

Directional Control of Radiation Heat Transfer from Solid Surface Using Grating Composed of Parallel Elliptical Cylinders -Directional Control of Energy Concetration- (타원주격자를 사용한 고체면에서의 복사열전달의 방향제어-에너지 집중 방향제어-)

  • Go, Heung;Hidetoshi Masuda;Jo, Byeong Su;Gang, Yeong Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제20권9호
    • /
    • pp.2933-2943
    • /
    • 1996
  • A grating composed of elliptical cylinders (GEC), specially designed, is applicable to control of radiation heat transfer from a heated surface, as reported in our previous work. In this study, an analysis of radiation heat transfer is performed for a physical model in which the GEC is placed in front of a heated black-base surface and the major axes of the elliptical cylinders are inclined as a certain angle from the normal to the row of elliptical cylinders. Numerical solutions are obtained. Variations of the direction and the radiative energy concentration with slant angle of the major axis are shown for some parameters. It is verified that the GEC is able to widely change the direction of radiation heat transfer from the heated surface.

Effect of Surface Area of Soybean Oil and Lard on the Thermooxidative Stability (대두유와 돈지의 가열산화 안정성에 미치는 표면적의 영향)

  • Kim, In-Hwan;Kim, Young-Soon;Choi, Yang-Moon
    • Korean Journal of Food Science and Technology
    • /
    • 제30권4호
    • /
    • pp.781-786
    • /
    • 1998
  • To assess effect of surface area on the oxidative stability in thermooxidative system, soybean oil and lard with different surface area $(0.04{\;}cm^2/g,{\;}0.08{\;}cm^2/g,{\;}0.12{\;}cm^2/g{\;}and{\;}0.16{\;}cm^2/g)$ were heated 8 hrs/day at $185^{\circ}C$. The iodine values of soybean oil heated for 64 hrs with surface area of $0.12{\;}cm^2/g$ and $0.16{\;}cm^2/g$ were 113.1 and 116.9, while those of the oil heated for the same length time with surface area of $0.04{\;}cm^2/g$ and $0.08{\;}cm^2/g$ were 126.4 and 125.9, respectively. The same trend was observed in lard, but less markedly than in soybean oil. The polar lipid content, dielectric constant and refractive index of soybean oil and lard heated with surface area above $0.12{\;}cm^2/g$ significantly increased as the heating time increased, while those of the oil heated with surface area below $0.08{\;}cm^2/g$ slowly increased as the heating time increased. On the other hand, the conjugated diene content of soybean oil heated with surface area above $0.12{\;}cm^2/g$ oil increased as the heating time increased while ratio of linoleic acid to palmitic acid decreased as the heating time increased. However, the conjugated diene content and ratio of linoleic acid to palmitic acid of lard were not significantly different depending on the surface area. The results obtained from this investigation indicated that the thermooxidative stability of oil heated with surface area below $0.08\;}cm^2/g$ was better than that of oil heated with surface area above $0.12{\;}cm^2/g$ (P<0.05).

  • PDF

Experimental Study on Evaporative Heat Transfer of Single Droplet on Heated Surface (가열 표면에서 액적의 증발열전달에 관한 실험적 연구)

  • Kim, Yeung Chan
    • Journal of ILASS-Korea
    • /
    • 제19권1호
    • /
    • pp.15-18
    • /
    • 2014
  • In the present study, experiment on the evaporation of pure water droplet on heated surface was conducted, and the evaporative heat transfer coefficients were calculated from experimental results. The pure water droplet of about $10{\mu}l$ was applied onto the heat transfer surface, then the shape of the droplet was analyzed during the evaporation. In addition, the effect of surface roughness on the evaporative heat transfer was also investigated. Experimental results showed that the evaporative heat transfer coefficients increased rapidly along with the increase of surface temperature and the heat transfer coefficients increased with the increase of surface roughness.

A Three-Dimensional Numerical Model of Thermal Discharge for Different Type of Effluent (배수방식에 따른 온수 방류의 3차원 수치모의)

  • Lee, Jin-Woo;Lee, Seung-Oh;Kim, Chang-Wan;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.387-390
    • /
    • 2007
  • The mixing characteristics of heated water discharged from different types of effluents are simulated using a commercial software, Flow-3D model. In order to verify the model, the comparison of numerical results with the experimental data are conducted for each type of effluent, the submerged and surface overfall. It is observed that the numerical results show a reasonable agreement with the experimental data. Based on this study the application to the heated water discharge problem in the field can be expected as a further study and it can be the fundamental data when determining the type of effluent in a powerplant.

  • PDF

Evaporation Cooling of a Droplet containing a Surfactant (계면활성제를 첨가한 액적의 증발냉각)

  • Riu, Kap-Jong;Bang, Chang-Hoon;Kim, Hyun-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제27권4호
    • /
    • pp.424-431
    • /
    • 2003
  • The evaporation cooling phenomenon of a droplet containing a surfactant on a heated surface has been studied experimentally. The two kinds of heater modules made of brass and Teflon$^{TM}$ were tested to investigate the cooling characteristics of droplet. Solutions of water containing Sodium Lauryl Sulfate(0 ppm, 100 ppm, 1000 ppm) were tested in the experiments. The results showed that the contact angle decrease as the concentration of surfactant increases. The tendency did not very with different heated solid materials. As initial temperature of the heated surface becomes high, time averaged heat flux increases and evaporation time decreases with the denser concentration of surfactant. Therefore, water with denser concentration of surfactant could be effective to cool flammable materials. However, the effect of surfactant becomes low as the material temperature is higher than the boiling temperature of water.

Power Line Communication-based Heated Glass Temperature Control System (전력선통신을 이용한 선박 및 건축용 발열유리 온도제어 시스템)

  • Lee, Su-Hyeong;Kim, In-Dong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제20권2호
    • /
    • pp.105-114
    • /
    • 2015
  • Heated glasses are widely used to prevent surface condensation and freezing in ship and building windows. This study proposes a heated glass temperature control system composed of power and control circuits to control the temperature of heated glasses. The proposed temperature control system adopts a digital controller instead of a conventional analog controller. Thus, the proposed system has better characteristics, such as precise setup and control of glass temperature, setup and control of output power, and control mode change between ON/OFF and phase controls. The system can also implement multi-functional control algorithms. The control characteristics are not dependent upon external disturbances, such as ambient temperature and electrical noises. Furthermore, the proposed temperature control system utilizes the power line communication (PLC) method to control the number of heated glasses without any extra communication lines. The system proposes a new communication protocol with strong immunity to electrical switching noises. A new sensorless algorithm is used to detect the temperature of the heated glass. This study presents the design guidelines in detail and its effectiveness are confirmed by implementing a 4-kw prototype temperature control system.

A Study on Surface Properties of Ablative Materials from 0.4MW Arc-Heated Wind Tunnel Test (0.4MW 아크 가열 풍동 시험을 통한 삭마 재료의 표면 특성 연구)

  • Kim, Nam Jo;Oh, Philyong;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • 제43권12호
    • /
    • pp.1048-1053
    • /
    • 2015
  • Ablative materials in a thermal protection system for atmospheric re-entry suffers from the most severe heat fluxes and temperatures, which induces surface recession in the thickness direction. In this paper, a 0.4MW arc-heated wind tunnel is operated to test for ablative materials, and a non-contact three-dimensional surface measuring system is used to evaluate the different surface characteristics of them. In particular, by postprocessing the three-dimensional image data, the surface roughness and recession of ablative materials can be calculated before and after the wind tunnel test. Moreover, the surface properties are analyzed quantitatively by comparing volume and mass losses of the test specimens.

Fabrication of in-situ Formed Namo-Composite Using Polymer Precursor : I. Adsorption Behavior of Polymer Followed $SiO_2$ Surface formation onto Silicon Nitride Surface (폴리머 Precursor를 이용한 in-situ 나노 복합체의 제조 : I. 질화규소 표면에서의 $SiO_2$ 피막형성에 따른 폴리머의 흡착거동)

  • 정연길;백운규
    • Journal of the Korean Ceramic Society
    • /
    • 제37권3호
    • /
    • pp.280-287
    • /
    • 2000
  • Adsorption behavior and amount of phenolic resin followed silica (SiO2) formation onto silicon nitride(Si3N4) surface were investigated using electrokinetic sonic amplitude (ESA) technique and with UV spectrometer, to fabricate Si3N4/SiC nano-composite based on reaction between SiO2 formed and phenolic resin absorbed onto Si3N4 particle. The amount of SiO2 formed and carbon from phenolic resin absorbed onto Si3N4 surface were calculated quantitatively to adjust the reaction between SiO2 and phenolic resin, resulting in no residual SiO2 and carbon. As a result, pre-heated tempeature for optimized reaction was below 25$0^{\circ}C$, in which there was no residual SiO2 and carbon.

  • PDF

Preparation of Porous Glasses by the Phase-separation of the Silicate Glass Containing $TiO_2$ ($TiO_2$를 함유한 규산염 유리의 상분리를 이용한 다공질 유리의 제조)

  • 김병훈;최석진;박태철
    • Journal of the Korean Ceramic Society
    • /
    • 제28권1호
    • /
    • pp.29-36
    • /
    • 1991
  • Microporous glasses in the system TiO2-SiO2-Al2O3-B2O3-CaO-Na2O were prepared by the phase-separation technique. Morphology and distribution of pore and specific surface area of glasses heated and leached out at various conditions were investigated by SEM and Porosimeter. Crystallization of glasses heated above transition temperature was also inspected by X-ray diffraction method. When the heating temperature and time increased, the pore size and volume increased, but the specific surface area decreased above the critical temperature. The phase-separation, specific surface area and pore size showed more sensitive change on the variation of heating temperature than of heating time. The specific surface area and micropore volume of porous glasses prepared in this study were about 120-330$m^2$/g and 0.001-0.01cc/g, respectively. Mean pore size of porous glasses were about 20-90$\AA$. Anatase phases was deposited when the parent glass was heat-treated at 75$0^{\circ}C$ for 6hrs.

  • PDF

Analysis of Temperature and Total Heat of Heated Glass through Experimental Measurement and Three-Dimensional Steady-State Heat Transfer Analysis (실측실험과 3차원 정상상태 열전달 해석을 통한 발열유리의 온도 및 전열량 분석)

  • Lee, Do-Hyung;Yoon, Jong-Ho;Oh, Myeong-Hwan
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.111-116
    • /
    • 2015
  • Heat loss from windows and condensation occuring on its surface due to its lower insulation value causes much discomfort to occupants. In this study, Heated glass was used to make a basic study on prevention of condensation on glass surface for its heating functionality through experimental measurement and simulation analysis of total heat flux on the interior and exterior surface of glass. Error between experimental results and three dimensional steady-state heat transfer analysis were caused firstly, beacuse in the experimental chambers, cold chamber and steady temperature and humidity chamber, air temperature setting was not constant but rather ON/OFF control, and secondly, due to error rate in heat flux meter due to heat flux direction even in stable conditions.