• 제목/요약/키워드: Heat-up time

검색결과 574건 처리시간 0.026초

CORRELATION BETWEEN THE TENSILE STRENGTH AND CORROSION BEHAVIOR OF HEAT TREATED ZR-1.0NB ALLOY

  • Kim, Tae-Kyu;Choi, Pyung-Sik;Yang, Sung-Ki;Lee, Chong-Tak;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.505-510
    • /
    • 2008
  • The correlation between the tensile strength and corrosion behavior of Zr-1.0wt%Nb alloy heat treated at $480^{\circ}C$ for up to 32 hours was evaluated. The tensile strength at $400^{\circ}C$ was continuously reduced with an increasing heat treatment time, mainly due to a grain growth and a decreased area fraction of the precipitates. However, the corrosion resistance in an aqueous ammonia solution at $360^{\circ}C$ was enhanced, mainly due to the formation of $\beta$-Nb precipitates. It is thus concluded that a longer heat treatment time provides a better corrosion resistance while degrading the tensile strength.

레이저 프린터 정착 시스템의 열전달 해석을 통한 승온 성능 및 정착성 예측 (Evaluation for Warming-up Performance and Fusing Quality through Heat Transfer Simulations of Laser Printer Fusing System)

  • 이진성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2231-2235
    • /
    • 2008
  • Thermal performance of fusing system in laser printer is determined by FPOT(First print out time) required and toner fusing quality. FPOT is influenced by the thermal resistance of fusing system between heat source and nip region. Also FPOT is depended by the heat source power and toner fusing temperature. The fusing quality of toner is decided by the temperature, pressure and duration time in nip region. In this study, I have performed thermal analysis for the toner fusing system. Computational simulation has been used to understand the effect of heat source power and printing speed etc. on the temperature distribution of the fusing system. Also in order to predict fusing quality, numerical simulation of the process that paper is continuously supplied to the nip regions were performed. In comparison with the experimental results of the fusing quality vs transferred calory to the toner layer, I could evaluate various fusing condition parameters effected on the thermal performance.

  • PDF

오스테나이트계 316강의 장시간 재료 열화에 따른 미세조직의 변화와 기계적 특성의 변화 (Variation in Microstrutures and Mechanical Properties During Long-term Material Degradation of Austenitic 316L Steel)

  • 공원식;김정석
    • 열처리공학회지
    • /
    • 제34권6호
    • /
    • pp.315-322
    • /
    • 2021
  • In this study, we investigate the variation in microstruture and mechanical property of austenitic 316L stainless steel during long-term material degradation. To simulate the material degradation, the AISI 316 steel was exposed to accelerate under a temperature of 600℃ for up to 10000 hours at each predetermined heat treatment time. As the long-term material degradation time increase, the grain shape was changed from polygonal grains with annealing twins to circular grains. Most twins distributed uniformly interior of grains are recovered and disappered with long-term material degradation. Also, the δ ferrite along grain boundaries decomposed and transformed into the σ phase resulting in decrease of elongation of austenitic 316L stainless steel.

수산물통조림의 살균조건에 관한 연구(2) 굴 훈제 기름담금 통조림 및 굴 보일드 통조림 (Evaluation of Thermal Processes for Canned Marine Products (2) Canned Smoked Oyster in Oil and Canned Boiled Oyster in Brine)

  • 박영호
    • 한국수산과학회지
    • /
    • 제17권3호
    • /
    • pp.165-169
    • /
    • 1984
  • 수출수산물통조림적 주요품목인 굴 훈제 기름담금 통조림 및 굴 보일드 통조림의 살균조건을 검토하는 자료를 얻기 위하여 상업적인 살균조건하에서 열전달치를 측정하고 이로부터 $F_0$ 값을 산출하여 검토하였다. 굴 훈제 기름담금 통조림(각 3호 B관의 $F_0$ 값은 14.58이었고, 굴 보일드 통조림(과실 7호관)의 $F_0$값은 14.78로, Clostridium botulnum A 형균의 치사치인 $F_0=4,03$을 기준으로 할 때 모두 비교적 강한 살균처리를 하고 있음을 알 수 있었다. 또한, 살균온도별로 $F_0$값과 살균시간과의 상관관계를 알기 위하여 열전달치로부터 $F_0$값에 따른 B값(살균시간에 come-up time의 $2\%$를 가산한 시간)을 산출하여 그 nomograph를 작성하였다.

  • PDF

학교 건물용 지열 히트펌프 시스템 설계와 지중 순환수 온도 변화 분석 (Design of Ground-Coupled Heat Pump (GCHP) System and Analysis of Ground Source Temperature Variation for School Building)

  • 손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Ground-coupled heat pump (GCHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. Although some experimental and simulation works related to performance analysis of GCHP systems for commercial buildings have been done, relatively little has been reported on the performance evaluation of GCHP systems for school buildings. The purpose of this simulation study is to evaluate the performance of a hypothetical GCHP system for a school building in Seoul. We collected various data of building specifications and construction materials for the building and then modeled to calculate hourly building loads with SketchuUp and TRNSYS V17. In addition, we used GLD (Ground Loop Design) V2016, a GCHP system design and simulation software, to design the GCHP system for the building and to simulate temperature of circulating water in ground heat exchanger. The variation of entering source temperature (EST) into the system was calculated with different prediction time and then each result was compared. For 20 years of prediction time, EST for baseline design (Case A) based on the hourly simulation results were outranged from the design criteria.

원심주조법으로 제조된 10% Cr 내열강의 등온 변태 거동 (Isothermal Transformation Behavior of 10% Cr Heat Resistant Steel Fabricated by Centrifugal Casting Process)

  • 김주업;이종훈;김두현;유위도;이재현
    • 열처리공학회지
    • /
    • 제27권2호
    • /
    • pp.72-78
    • /
    • 2014
  • Isothermal transformation behavior of a 10% Cr heat resistant steel fabricated by centrifugal casting process was investigated. Normalized specimen at $1100^{\circ}C$ for 1 hour was isothermally annealed at temperature range between $600^{\circ}C$ and $700^{\circ}C$ with various time. The annealed specimen had eutectoid structure which was generated along austenitic grain boundary during isothermal annealing. Areal fraction of eutectoid structure increased up to 25% after holding at $700^{\circ}C$ for 20 hours. It was observed that austenitic matrix was transformed to ferrite structure and fine $M_{23}C_6$ carbides with increase of annealing time. Time-temperature-transformation diagram of the centrifugally cast 10% Cr steel with 0.18 wt% C was plotted based on the results of isothermal transformation behavior.

노면상태를 고려한 전차 궤도 고무의 열발생에 관한 연구 (Study on the Heat Generation of Tank Track Rubbers under the Consideration of the Road Conditions)

  • 김병탁;김광희;윤문철
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.166-175
    • /
    • 2002
  • Tank track rubbers, which undergo dynamic stresses and strains under various road conditions, leads to a result of considerable internal temperature rise due to the heat generation. Since rubber materials are not fully elastic, a part of the mechanical energy is converted into heat because of the hysteresis loss. Heat generation without adequate heat dissipation leads to heat build-up, i.e. internal temperature rise which, if excessive, exerts a bad influence upon the performance and the life of the tank track rubbers. The purpose of this paper is to predict temperature distributions of the rubber components off tank track subjected to complex dynamic loads under various read conditions. In steady state analysis temperature fields are displayed in contour shapes, and in unsteady analysis the temperature variations of some important nodes are represented graphically with respect to the running time of the tank.

매입형 히트파이프의 재질 및 규격변화에 따른 수화열 분산 효과 (Dispertion Effect of Hydration Heat due to Materials and Standard Variation of Embedded Heat Pipe)

  • 김명식;염치선;백동일
    • 한국해양공학회지
    • /
    • 제23권6호
    • /
    • pp.111-116
    • /
    • 2009
  • The cracking due to hydration heat in mass concrete must be resolved to improve the stability and durability of concrete structures. In this study, the economic efficiency was improved by replacing a copper pipe with a steel one for the heat pipe, and the heat pipe was standardized to significantly improve the operation efficiency, such as the processing, transport, assembly, and construction time. As a result of the experiment, the peak temperature of the ICSHP, ISSHP, and ISUHP specimens decreased by about $7.2{\sim}10.9^{\circ}C$ compared to the OPC specimen and the probability of a thermal crack being generated in the ICSHP, ISSHP, and ISUHP specimens decreased by up to 84~88%.

Wilson Plot을 이용한 만액식 증발기의 열전달계수 측정 (Measurement of Heat Transfer Coefficient in a Flooded Evaporator through Wilson Plot Method)

  • 윤필현;강용태;정진희
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.698-706
    • /
    • 2004
  • Heat transfer coefficients of enhanced tubes in a flooded evaporator are measured through Wilson Plot method. And the correlations are proposed to design a flooded evaporators. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. Usually the experiments have been conducted separately. But there have been many difficulties like setting up the equipments and measuring the wall temperature. Wilson Plot method makes it possible to measure the separated transfer coefficients at the same equipment through experimental skills. So the cost and time can be reduced. And the results are reliable enough to use for design. Heat transfer coefficients inside the tube were able to be correlated uniquely in spite of various outside conditions. Boiling heat transfer of R134a is more dependent on the saturation temperature and much higher than that of R123.

박테리아 영양소 성분이 시멘트 복합체의 초기 특성에 미치는 영향 (Effects of Bacterial Nutrients on Early Cement Composites Properties)

  • 장인동;김백중;이종구
    • 대한건축학회논문집:구조계
    • /
    • 제34권3호
    • /
    • pp.53-59
    • /
    • 2018
  • When manufacturing self-healing concrete using bacteria, nutrients are added to increase the activity of the bacteria. Although many researches have focused on the effects of nutrients containing bacterial healing agent on concrete, few have studied the effects of sole nutrient on self-healing of cement composites. Bacterial nutrients, like commercial chemical admixtures, affect hydration characteristics such as flow, setting, hydration heat, mechanical strength of cement composites and also affect the self healing of cement composites by hydration of unhydrated particles. In this study, effect of the four nutrient commonly used in the existing literature on the hydration characteristics of cement composites by its addition was investigated. Flow, setting time, hydration heat, compressive strength have studied for each nutrients added by 1.5% and 3% of cement weight. Experimental results shows that urea and calcium-nitrate can be used up to 3% without significant detrimental effect on cement composites. Addition of calcium-lactate up to 1.5% show better compressive strength than control, but addition of 3% show almost non-hydration. Yeast extract shows detrimental effects on the composites regardless of the amount added.