• 제목/요약/키워드: Heat-setting

검색결과 377건 처리시간 0.03초

연신비와 열고정 온도에 따른 Partially Oriented Polyester Yarn(POY)의 구조변화와 물성 (The Change of Crystal Structure and Physical Properties of Partially Oriented Polyester Yarn(POY) on the Draw Ratio and Heat Setting Temperature)

  • 박명수;윤종호
    • 한국염색가공학회지
    • /
    • 제12권2호
    • /
    • pp.103-110
    • /
    • 2000
  • To examine the physical properties of POY through the microstructure control, the crystal structure such as the crystallinity, the crystallite size, the orientation, the shrinkage, the tensile properties, and the thermal stress of POY(80/48, SD) were examined at different draw ratios and annealing temperatures. From the examination following conclusions were obtained : 1. The crystallinity was more effected by the heat setting temperature than by the draw ratio. The increasing rate was greatest at the heat setting temperature range of $170~190^\circ{C}$. 2. The crystallite size perpendicular to the fiber axis was more effected by the annealing temperature at lower draw ratios. On the other hand, the crystal and amorphous orientations were more effected by the heat setting at higher draw ratios. 3. The boiling shrinkage did not change significantly, but the total shrinkage showed 13% at the draw ratio 1.9 and the heat setting temperature $170^\circ{C}$. 4. The maximum thermal stress increased with increasing the draw ratio and decreasing the heat setting temperature in the temperature range of $170~210^\circ{C}$. At the draw ratio 1.9 and the heat setting temperature $170^\circ{C}$, the maximum thermal stress found was 1.1gf/d. 5. In the heat setting temperature above $170^\circ{C}$ after the drawing, the crystallinity, the crystallite size, the orientation, and the strength increased with increasing temperature, but the shrinkage and the maximum thermal stress decreased with increasing temperature.

  • PDF

실내설정온도에 따른 태양열 하이브리드 열펌프 시스템 운전특성에 대한 실험적 연구 (Experimental Study on the Operating Characteristics of a Solar Hybrid Heat Pump System according to Indoor Setting Temperature)

  • 김원석;조홍현
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.50-58
    • /
    • 2010
  • Experimental study on the operating characteristics of a solar hybrid heat pump system according to indoor setting temperature were carried out during spring and winter season. The system was consisted of a concentric evacuated tube solar collector, heat medium tank, heat storage tank, and heat pump. As a result, the heating load was increased by 21.1% when the indoor setting temperature rose by 2oC for the same ambient temperature. Besides, the spring season had good outdoor conditions compared to the winter season, therefore the heating load was reduced and heat gain by collector increased, relatively. In case of the winter season, the solar fraction was shown less than 10% because the heat losses of system and space increased considerably. The solar fraction decreased significantly as the indoor setting temperature increased.

편망 후 열처리 온도가 PBS 모노필라멘트사의 물리적 특성에 미치는 영향 (Effects of heat setting temperature conditions on the mechanical properties of Polybutylene succinate (PBS) monofilament yarn after net-making)

  • 박성욱;김성훈
    • 수산해양기술연구
    • /
    • 제48권1호
    • /
    • pp.20-28
    • /
    • 2012
  • The monofilament with 0.304mm of diameter was produced using a polybutylene succinate (PBS) resin, and a gill net was made by it. We investigated the impact of heat setting temperature on the mechanical properties, knot state and height of gill net. Heat treatment was carried out using the high pressure steam machine for 20 minutes at temperature of $55^{\circ}C$, $60^{\circ}C$, $70^{\circ}C$ and $75^{\circ}C$. Before heat treatment, the strength and elongation of PBS monofilament were estimated to be $48.1kg/mm^2$, 23.8% at unknot, $37.6kg/mm^2$, 18.8% at single knot, $26.6kg/mm^2$, 22.9% at double knot in dry condition, respectively. The strength and elongation of PBS monofilament with double knot were decreased as heat setting temperature increased, and the decreasing rate of strength was showed to be higher than that of elongation. It was not found any differences in strength and elongation of PBS monofilament yarn with double knot at the $65^{\circ}C$ and $70^{\circ}C$ of heat setting temperature by 5% significance of T-test, but there was a significant difference at the $70^{\circ}C$ and $75^{\circ}C$ of heat setting temperature. The net's height and length from leg to leg appeared no differences at the $70^{\circ}C$ and $75^{\circ}C$ of heat setting temperature. In results, it was investigated that the PBS monofilament gill net with the maximized physical properties could be manufactured at $70^{\circ}C$ of heat setting temperature using a high pressure steam machine for 20 minutes.

기초 매스콘크리트의 수화열 저감을 위한 초지연제 응결시간차 공법의 현장 적용 (Construction Considering the Difference of Setting Time of Super Retarding Agent for Reduction of Hydration Heat of Footing Mass Concrete)

  • 황인성;배정렬;윤석명;김기철;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.95-98
    • /
    • 2003
  • This paper presents the results of field experiment to apply the difference of setting tine method using super retarding agent for reducing hydration heat of mass concrete of foundation. According to the results, as the properties of fresh concrete, base concrete satisfies aimed slump and air content, and there is no difference of slump and air content with mixture of super retarding agent. The mixing ratio of super retarding agent is determined for setting time to be retarded by 12 hours in comparison with base concrete, but because the temperature of the air and concrete is low, the difference of setting time is retarded to 24 hours. In man concrete of foundation to which the difference of setting time method is applied, crack by hydration heat is not seen because the lower concrete of super retarding agent generates heat after generation of hydration heat of the upper concrete.

  • PDF

자동차호스용 PET 브레이딩 직물의 최적 ATY 공정조건 (The Optimum Processing Conditions of ATY for PET Braiding for Automotive Hoses)

  • 김승진;최우혁;김상룡;조진황;문찬
    • 한국염색가공학회지
    • /
    • 제21권4호
    • /
    • pp.11-22
    • /
    • 2009
  • This study surveys the optimum processing conditions of ATY for PET braiding for automotive hoses. For this purpose, high tenacity and low shrinkable PET filaments with three types of deniers are prepared. Twenty seven ATY specimens are manufactured with variation of feed speed and overfeed on the air jet texturing machine. The physical properties of various yam according to the ATY processing conditions are measured and analysed for deciding the optimum ATY processing condition. Two kinds of ATY filaments made under the optimum air texturing conditions are processed with variation of tpm, heat setting temperature and heat setting time on the 2-for-l twister and setting chamber, respectively. The optimum twisting and heat setting conditions are decided through analysis of the yam physical properties. Finally, the braiding fabric specimens are manufactured using conventional filament and newly developed filament made under optimum twisting and heat setting conditions. The bursting strengths of these braiding specimens are compared and discussed between two types of specimens.

초지연제의 응결시간차에 따라 분할타설된 매스 콘크리트의 수화열 저감 (Reduction of Hydration Heat in Division-Placed Mass Concrete Considering the Difference of Setting Time in Super Retarding Agents)

  • 지석;배정렬;황인성;윤치환;김기철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.805-808
    • /
    • 2002
  • This study is designed to reduction of hydration heat of 4 layer division-placed mass concrete considering the difference of setting time of super retarding agent. According to the results, peak temperature of plain concrete by hydration heat show $63^{\circ}C$ around the age of 1 days. Hydration heat is lowest in the bottom layer, and highest in the middle of 3rd layer from the bottom. Hydration heat of mock up structure, which is division-placed at the same interval of 1 and 2 days by setting time difference of super retarding agent, is highest in the bottom layer because after peak temperature of 4th layer, hydration reaction progresses in order of 3rd, 2nd and 1st layer. But in mock up structure which is division-placed at the various interval. peak temperature by hydration heat is reduced by about $13^{\circ}C$, compared with plain concrete because after first peak hydration heat of 4th layer (plain concrete), hydration reaction progresses after the drop of hydration heat in order of 3rd, 2nd and 1st layer.

  • PDF

결합재 종류에 따른 응결과 수화발열 특성 (Setting and Hydration Heat Development Characteristics with Binder Types)

  • 박찬규;이승훈;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.369-374
    • /
    • 2002
  • In this paper, setting and hydration heat development characteristics with three binder types, type IV cement+fly ash, type IV cement+slag powder and type IV cement + limestone powder. were investigate. As results, it was shown that the limestone powder decreased the initial setting time regardless of replacement ratio, especially the range of 20~50% replacement ratio, and the 2nd peak was shifted ahead when the limestone powder replacement ratio increased. But for the f1y ash and the limestone powder, contrary results were obtained compared with the limestone powder.

  • PDF

초지연제의 응결시간차를 이용한 매스 콘크리트의 수화열 저감을 위한 현장 적용 (Field Application of Mass Concrete Using Setting Time Difference of Super Retarding Agent for Reduction of Hydration Heat)

  • 전충근;심보길;손성운;신동안;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Busan. Horizontal placing lift is applied. According to test results. slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. Compressive strength of concrete cured in place is achieved more than the values of nominal strength at l4days. For temperature history, maximum temperature of center at top section shows 58.5$^{\circ}C$, and at bottom section, 62.6$^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 현장 적용 -대전 가오지구 코오롱 하늘채 아파트 현장- (Field Application of Setting Time Difference Method Using SRA for Reduction of Hydration Heat of Mass Concrete)

  • 전충근;김종;신동안;윤기원;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.21-24
    • /
    • 2005
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Daejeon. Horizontal placing lift is applied. According to test results,: slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. For temperature history, maximum temperature of center at top section shows $25.6^{\circ}C$, and at bottom section, $35.4^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

히트펌프 시스템의 시설원예 적용에 관한 실험적 연구 (An Experimental Study on Applying Heat Pump System to Facility Horticulture House)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.