• Title/Summary/Keyword: Heat-cool test

Search Result 49, Processing Time 0.024 seconds

Evaluation of Defects of Thermal Barrier Coatings by Thermal Shock Test Using Eddy Current Testing (열차폐 코팅층의 고온 열충격 시험후 ECT를 이용한 결함 평가)

  • Heo, Tae-Hoon;Cho, Youn-Ho;Lee, Joon-Hyun;Oh, Jeong-Seok;Lee, Koo-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.450-457
    • /
    • 2009
  • Periodical thermal shock can introduce defects in thermal barrier coating made by layers of CoNiCrAlY bond coating(BC) and $ZrO_2-8wt%Y_2O_3$ ceramic top coating(TC) on Inconel-738 substrate using plasma spraying. Thermal shock test is performed by severe condition that is to heat until $1000^{\circ}C$ and cool until $20^{\circ}C$. As the number of cycle is increased, the fatigue by thermal shock is also increased. After test, the micro-structures and mechanical characteristics of thermal barrier coating were investigated by SEM, XRD. The TGO layer of $Al_2O_3$ is formed between BC and TC by periodical thermal shock test, and its change in thickness is inspected by eddy current test(ECT). By ECT test, it is shown that TGO and micro-crack can be detected and it is possible to predict the life of thermal barrier coating.

Effects of rehydration fluid temperature and composition on body weight retention upon voluntary drinking following exercise-induced dehydration

  • Park, Sung-Geon;Bae, Yoon-Jung;Lee, Yong-Soo;Kim, Byeong-Jo
    • Nutrition Research and Practice
    • /
    • v.6 no.2
    • /
    • pp.126-131
    • /
    • 2012
  • The purpose of this study was to determine the effects of beverage temperature and composition on weight retention and fluid balance upon voluntary drinking following exercise induced-dehydration. Eight men who were not acclimated to heat participated in four randomly ordered testing sessions. In each session, the subjects ran on a treadmill in a chamber maintained at $37^{\circ}C$ without being supplied fluids until 2% body weight reduction was reached. After termination of exercise, they recovered for 90 min under ambient air conditions and received one of the following four test beverages: $10^{\circ}C$ water (10W), $10^{\circ}C$ sports drink (10S), $26^{\circ}C$ water (26W), and $26^{\circ}C$ sports drink (26S). They consumed the beverages ad libitum. The volume of beverage consumed and body weight were measured at 30, 60, and 90 min post-recovery. Blood samples were taken before and immediately after exercise as well as at the end of recovery in order to measure plasma parameters and electrolyte concentrations. We found that mean body weight decreased by 1.8-2.0% following exercise. No differences in mean arterial pressure, plasma volume, plasma osmolality, and blood electrolytes were observed among the conditions. Total beverage volumes consumed were $1,164{\pm}388$, $1,505{\pm}614$, $948{\pm}297$, and $1,239{\pm}401$ ml for 10W, 10S, 26W, and 26S respectively ($P$ > 0.05). Weight retention at the end of recovery from dehydration was highest in 10S ($1.3{\pm}0.7kg$) compared to 10W ($0.4{\pm}0.5kg$), 26W ($0.4{\pm}0.4kg$), and ($0.6{\pm}0.4kg$) ($P$ < 0.005). Based on these results, carbohydrate/electrolyte-containing beverages at cool temperature were the most favorable for consumption and weight retention compared to plain water and moderate temperature beverages.

A Study on Alternative Fan Selection and Verification in Military Electronic Equipment (방산용 전자장비의 팬 선정 및 검증에 관한 연구)

  • Jin, Sung Eun;Kim, Hwan Gu;Yoon, Eui Youl;Jeon, Hee Ho;Kim, Seung Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1091-1097
    • /
    • 2017
  • Sales of commercial-type cooling fans intended for application in military electronics are often discontinued during equipment production. This results in requirements for alternative fan selection as well as equipment performance and reliability tests, such as high-temperature operation testing. This study deals with alternative fan selection and verification methods that can be used during the production process. First, an alternative fan was selected by calculating the flow and pressure required to effectively cool the equipment, then the feasibility of the selected fan was verified using a reliable CFD heat dissipation analysis model. Following this, a high-temperature operation test was performed using the alternative fan in the equipment. Results demonstrated that the equipment satisfied its required function in a high-temperature environment, and the main parts as well as internal air temperature were found to be thermally stable.

Design & Performance of the Solar Energy Research & Test Center (태양에너지 연구 시험센타 설계 및 효율에 관한 연구)

  • Auh, Paul Chung-Moo;Lee, Jong-Ho;Choi, Byung-Owan;Cho, Yil-Sik
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.29-36
    • /
    • 1982
  • The Solar Energy R&D Department of KIER under the auspice of the Korean government is pushing hard on the development of the passive solar technology with high priority for the expeditious widespread use of solar energy in Korea, since the past few years of experiences told us that the active solar technology is not yet ready for massive commercialization in Korea. KIER has completed the construction of the Solar Energy Research & Test Center in Seoul, which houses the major facilities for its all solar test programs. The Center was designed as a passive solar building with great emphasis on the energy conserving ideas. The Center is not only the largest passive building in Korea, but also the exhibit center for the effective demonstration of the passive heating and cooling technology to the Korean public. The Center was designed to satisfy the requirements based on the technical and economical criteria set by the KIER. Careful considerations, therefore, were given in depth in the following areas to meet the requirements. 1) Passive Heating Concepts The Center employed the combination of direct and indirect gain system. The shape of the Center is Balcomb House style, and it included a large built-in sunspace in front. A partition, consists of transparent and translucent glazings, separates the sunspace and the living space. Since most activities in the Center occur during the day time, direct utilization of the solar energy by the living spaces was emphasized with the limited energy storage capacity. 2) Passive Cooling Concepts(for Summer) Natural ventilation concept was utilized throughout the building. In the direct gain portion of the system, the front glazing can be openable during the cooling season. Natural convection scheme was also applied to the front sunspace for the Summer cooling. Reflective surfaces and curtains were utilized wherever needed. 3) Auxiliary Heat ing and Cooling System As an auxiliary cooling system, mechanical means(forced convection system) were adopted. Therefore forced air heating system was also used to match the duct work requirements of the auxiliary cool ing system. 4) Effect ive Insulation & Others These included the double glazed windows, the double entry doors, the night glazing insulation, the front glazing-frame insulation as well as the building skin insulation. All locally available construction materials were used, and natural lightings were provided as much as possible. The expected annual energy savings (compared to the non-insulated conventional building)of the Center was estimated to be about 80%, which accounts for both the energy conservation and the solar energy source. The Center is being instumented for the actual performance tests. The experimental results of the simplified tests are discussed in this paper.

  • PDF

1-D Analysis for Water Spray Cooling of Exhaust Gas in Combustor Test Facility (물 분무를 이용한 연소가스 냉각 1차원 해석)

  • Im, Ju Hyun;Kim, Myung Ho;Kim, Yeong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The cooling of hot exhaust gas is an important issue for the construction of combustor test facility. Water spray is an effective method for exhaust gas cooling due to its large latent heat in process of evaporation. In this study, 1-D analysis has been performed based on continuity, energy conservation, and saturated vapor property to understand water spray cooling of combustion gas. In the exhaust duct of combustor test facility, the injected water decreases combustion gas temperature, and evaporates in the combustion gas. However, some of the injected water is collected in the sump due to condensation. The evaporation of water helps combustion gas cooling, but causes pressure increase inside the exhaust duct due to increase of vapor pressure. These phenomena has been analyzed by 1-D modeling in this study. From 1-D analysis, the adequate mass flow rate of water spray to cool combustion gas and to avoid excessive pressure rise inside the exhaust duct has been decided.

A study on the change effect of emission regulation mode on vehicle emission gas (배기가스 규제 모드 변화가 차량 배기가스에 미치는 영향 연구)

  • Lee, Min-Ho;Kim, Ki-Ho;Lee, Joung-Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1108-1119
    • /
    • 2018
  • As the interest on the air pollution is gradually rising at home and abroad, automotive and fuel researchers have been studied on the exhaust and greenhouse gas emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward two main issues : exhaust emissions (regulated and non-regulated emissions, PM particle matter) and greenhouse gases of vehicle. Exhaust emissions and greenhouse gases of automotive had many problem such as the cause of ambient pollution, health effects. In order to reduce these emissions, many countries are regulating new exhaust gas test modes. Worldwide harmonized light-duty vehicle test procedure (WLTP) for emission certification has been developed in WP.29 forum in UNECE since 2007. This test procedure was applied to domestic light duty diesel vehicles at the same time as Europe. The air pollutant emissions from light-duty vehicles are regulated by the weight per distance, which the driving cycles can affect the results. Exhaust emissions of vehicle varies substantially based on climate conditions, and driving habits. Extreme outside temperatures tend to increasing the emissions, because more fuel must be used to heat or cool the cabin. Also, high driving speeds increases the emissions because of the energy required to overcome increased drag. Compared with gradual vehicle acceleration, rapid vehicle acceleration increases the emissions. Additional devices (air-conditioner and heater) and road inclines also increases the emissions. In this study, three light-duty vehicles were tested with WLTP, NEDC, and FTP-75, which are used to regulate the emissions of light-duty vehicles, and how much emissions can be affected by different driving cycles. The emissions gas have not shown statistically meaningful difference. The maximum emission gas have been found in low speed phase of WLTP which is mainly caused by cooled engine conditions. The amount of emission gas in cooled engine condition is much different as test vehicles. It means different technical solution requires in this aspect to cope with WLTP driving cycle.

A Study on Direct Cooling and Washing Machine for Energy Saving-Type Dyeing Machine (에너지 절감형 염색기용 직접냉각수세장치에 대한 연구)

  • Han, Seung-Chul;Kim, Jin-Ho;Kim, Je-Hoon;Lee, Sung-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.485-491
    • /
    • 2012
  • Due to increase in production of the domestic textile industry, energy consumption in textile industry is still growing. Traditional dyeing machine has high temperature and pressure. Accordingly, it uses an indirect cooling system that utilize a heat exchanger to cool after the dyeing. However, this indirect cooling system consumes a great deal of water, takes prolonged periods of time to process and, most importantly, because of the condensing of the dye at the cooling stage requires further energy in reduction cleaning and washing process. Therefore, in this paper, we propose a direct cooling washing machine that replaces the traditional indirect cooling system to provide coolant into the dyeing machine. The newly proposed direct cooling washing machine will still use parts of the traditional dying but will be able to skip the cooling as well as the reduction cleaning and washing process, resulting in less processing time and lower energy consumption. Also, we made a prototype. The prototype was applied to dyeing machine to test the direct cooling washing machine's ability and dyeing property. Additionally, we compared indirect cooling washing machine with direct cooling washing machine about ability, material and energy saving assessment.

Assessment of Wear Comfort and the Development of One-piece Dresses with Persimmon Juice Dye-printed Fabrics (감즙염색 날염 소재 원피스 개발과 인체착용실험에 의한 생리반응 및 착용감 평가)

  • Park, Soon Ja;Kang, Inhyeng
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.38 no.1
    • /
    • pp.73-86
    • /
    • 2014
  • Persimmon juice dye-printed fabrics with printing were used for a Galot one-piece dress. The Galot dress was assessed in comparison to a white undyed one-piece dress of the same design through a wearing test conducted in a climatic chamber with an air temperature of $30{\pm}1^{\circ}C$, $50{\pm}5%$ R.H, and 0.2m/sec air movement on 4 healthy female subjects in their 20s. The subjects went through a 30-min stable period, a 30-min exercise of walking on a $5^{\circ}$ slope treadmill at 70m/min period, and a 20-min recovery period. In addition, a physiological reaction and subjective sensation were estimated. The results showed that significant differences were mostly observed from a sweating period that occurred during the latter half of the exercise. More specific results are as follows. First, skin temperature on the chest and mean skin temperature were significantly higher (p<.01) in rayon dyed sample dresses. Second, micro-humidity on the back showed a significant difference (p<.01). Both cotton and rayon persimmon juice dyed sample dresses produced lower microhumidity than their counterparts and as for cotton the difference occurred over the entire experimental period; however, it occurred after the middle of the exercise period for rayon. Third, the sweating rate on the back decreased in both cotton and rayon with persimmon juice dye but no significant difference was observed. Fourth, subjective three sensations revealed significant differences between cotton and rayon (p<.01), indicating that the subjects felt more cool, dryer and more comfortable in a cotton Galot. As described above, the analysis of physiological responses and the subjective sensation of undyed and dyed clothing shows the effect of persimmon juice dyeing. Persimmon juice dyeing also seemly increased air permeability, moisture regain and permeability facilitating body heat ventilation, as micro-humidity and sweat rate were lowered. However, this was not shown consistently in subjective responses on comfort especially when wearing rayon dresses.

An Exploratory Study of Energy Conservation Practices in Clothing, Food, and Housing ($\cdot$$\cdot$주별 열에너지 소비절약 실태에 관한 조사연구)

  • 강혜원
    • Journal of the Korean Home Economics Association
    • /
    • v.19 no.2
    • /
    • pp.11-24
    • /
    • 1981
  • The objectives of the study were to determine 1) if energy consumption and conservation vary in clothing, food, and housing with independent variables-size of household, homemaker's age, employment, and level of education, level of living, type of house, electricity use, and all energy use, and 2) if there is a correlation among energy conservation practices in clothing, food, and housing. Questionnaires wee given to the randomly selected homemakers in Seoul in July, 1980. Data from 620 responses were analyzed by F-test (Analysis of Variance) and Correlation. The results are as follows: 1. Clothing (1) the scores of the conservation practices I clothing were generally high. /However, it was found that a) they did not practice in wearing heavy under clothes and behavior outer clothing to cope with cool room temperature in the winter, b) they did not use bleach for laundry, but they used boiling method, and c) they did not have enough knowledge on Permanent Press finish. (2) energy conservation practices in clothing were significantly related to level of living and homemakrer's level of education. a) The higher the level of living, the higher scores in the knowledge were found. b) the higher the homeakcer's level of education, the higher scores in the knowledge and ironing were obtained. 2. Food (1) The scores of the conservation practices in food were generally high. However, it was found that scientific cooking methods were not performed such as a) to use measuring spoons, cups, and timers, b) to practice a simple method in using solor energy for warming water, c) to use thermos for the hot water tea or coffee, but they boiled water whenever necessary, and b) to use the pressure cooker whenever possible. (2) Energy conservation practices in food were significantly related to homemaker's employment and type of dwellings. a) The scores of full-time homemakers (not gainfully employed) were higher than gainfully employed homemakers. b) Families in traditional Korean dwellings revealed higher scores than those in apartment or western style dwellings. 3. Housing (1) The scores of the conservation practices in housing were generally high. However, it was found that a) they did not install fans in the kitchen, bathroom, and attic in the summer, b) they did not install a humidifier for tolerating a lower room temperature in the winer, c) they did not practice to make plans for the door of the refrigerator remained open for the shortest time, d) they did not install or use a local lighting with a general lighting for reading and cooking, and e) they usedaluminum foil without the knowledge of the heat reaction of its shiny and dull sides. (2) energy conservation practices in housing were significantly related to homemaker's employment and level of education, economic status, types of dwelling, and all energy use, a) Full-time homeakers had higher scores than gainfully employed homeakers. b) the higher the homemaker's level of education and economics status, the higher scores were obtained. c) Homeakers with their own house scored higher points than those with rented houses. And families in apartment or row houses scored higher points than those in traditional korean or western style dwellings. d) The higher the consumption rate of electricity and all energy, the higher scores were revealed. 4. correlation there was a significant correlation among energy conservation practices I clothing, food, and housing.

  • PDF