• Title/Summary/Keyword: Heat-conservation

Search Result 373, Processing Time 0.026 seconds

A Study on Building Energy Demand for Design of Energy System on Green Home Apartment (그린홈 공동주택의 최적 에너지 공급시스템 설계를 위한 부하 예측 연구)

  • Park, Jae-Wan;Yoon, Jong-Ho;Kwak, Hee-Youl;Lee, Jae-Bum;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.24-31
    • /
    • 2013
  • More than 23% of total nation's energy is consumed by residential building and 57.2% of Korean people are living in apartment. This study was carried out to two kind of process. First, after selecting one standard apartment, our research team investigate realistic energy consumption. Second, using 3-dimension heat transfer tool(TRISCO RADICON) and building energy simulation tool(Visual DOE) As a result, amount of heating and hot-water energy is composed of above 80 percent in standard apartment. And, after applying high performance technologies to standard apartment, namely, after being green home apartment, total energy consumption is reduced by54.6 percent. Also, because of energy consumption characteristics of green home apartment, for making more high performance green home apartment, especially, we have to figure out effective method to reduce electric and hot water energy.

The Stability of Heat Deterioration of Pressure Sensitive Tapes for Repairing Documents(I) (Physiochemical Characteristics of Imported or Manufactured Tapes Repairing Documents) (종이 기록물 보수용 안전 테이프의 열화 안정성 연구(I) (수입 및 국내 시제품 물리 화학적 특성 비교))

  • Shin, Joung-Soon;Yoo, Sun-Kyun;Kang, Young-Reet
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • The physicochemical characteristics, adhesion power, and conservation of imported tapes repairing documents that consisted of adhesive, carrier, and masking were investigated. Materials related to pressure sensitive adhesive produced in domestic companies were examined also. And then, the performance evaluation of prototype manufactured in our laboratory was undertaken. Both the pressure sensitive tapes were compared. The polyacrylate of adhesive agents such as polyacrylate, starch, Glue, and PVA of imported tapes was best. The adhesion strength, power, reversibility, and stability (deterioration) of imported tapes were analyzed. By comparing results of imported tapes, two adhesive agents were selected finally. The carriers of imported tapes are made of one of papers, cotton sheets, and felts. Major carrier material was a paper. The jutes, conifers, and hardwoods were main ingredient of papers. The durability of Hangi($18{\pm}2g/m^2$) was one and half times superior to imported one.

A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode (비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교)

  • Kim, Yong-Ki;Lee, Tae-Won;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF

New Lighting Control System for Light Devices (새로운 조명기기 점등제어 시스템)

  • In, Chi-Goog;Yoon, Dal-Hwan;Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.261-266
    • /
    • 2011
  • In this paper, new efficient lighting control system for light devices is proposed to reduce power consumption and increases LED life-cycle and heat efficiency of LED lighting module. The new proposed lighting control system for light devices divides into 4 stages according to the illuminance surrounding by measuring illuminance and apply to automatic pattern lighting algorithm. And via level check will be light up for set time by applying intersection lighting algorithm of magic square pattern forming a fully symmetrical. Experimental analysis results, shows heating value and power consumption reduced to maximum 30 percent and lifetime of LED improved to maximum 60 percent in comparison with previous lighting system so applying system to LED streetlight, stable and high energy efficiency can be acquired.

Dynamic Characteristics of Transverse Fuel Injection and Combustion Flow-Field inside a Scramjet Engine Combustor

  • Park, J-Y;V. Yang;F. Ma
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.62-68
    • /
    • 2004
  • A comprehensive numerical analysis has been carried out for both non-reacting and reacting flows in a scramjet engine combustor with and without a cavity. The theoretical formulation treats the complete conservation equations of chemically reacting flows with finite-rate chemistry of hydrogen-air. Turbulence closure is achieved by means of a k-$\omega$ two-equation model. The governing equations are discretized using a MUSCL-type TVD scheme, and temporally integrated by a second-order accurate implicit scheme. Transverse injection of hydrogen is considered over a broad range of injection pressure. The corresponding equivalence ratio of the overall fuel/air mixture ranges from 0.167 to 0.50. The work features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the previous studies. In particular, the oscillatory flow characteristics are captured at a scale sufficient to identify the .underlying physical mechanisms. Much of the flow unsteadiness is related not only to the cavity, but also to the intrinsic unsteadiness in the flow-field. The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The roles of the cavity, injection pressure, and heat release in determining the flow dynamics are examined systematically.

  • PDF

A Study on the Life Cycle Cost Analysis of the See-through a-si Building Integrated Photovoltaic System (투광형 비정질 BIPV 시스템의 LCC 평가에 관한 연구)

  • Lee, Han-Myoung;Oh, Min-Seok;Kim, Hway-Suh
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • This study was carried out to evaluate the Life Cycle Cost(LCC) of three types of RTPV(Building Integrated Photovoltaic) systems-Glass plus Granite. Crystalline BIPV and See through Amorphous BIPV-which were vertically installed to generate the same power output(76 kW level). Initial investment costs. cost. savings and maintenance costs had been predicted during the period of analysing the LCC of three types of BIPV(Building Integrated Photovoltaic) systems installed for the purpose of evaluating the LCC. In case of cost savings, it had been analyzed by measuring the amount of electric power generated, reduction in lighting load and heat & cooling loads through simulation. From this analysis, it was predicted that the See-through amorphous BIPV offering cost saving advantages demonstrated the economical efficiency similar to the Class plus Granite when it is backed by more than 20 years of durability.

A SIMPLE ANALYTICAL METHOD FOR NONLINEAR DENSITY WAVE TWO-PHASE INSTABILITY IN A SODIUM-HEATED AND HELICALLY COILED STEAM GENERATOR

  • Kim, Seong-O;Choi, Seok-Ki;Kang, Han-Ok
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.841-848
    • /
    • 2009
  • A simple model to analyze non-linear density-wave instability in a sodium-cooled helically coiled steam generator is developed. The model is formulated with three regions with moving boundaries. The homogeneous equilibrium flow model is used for the two-phase region and the shell-side energy conservation is also considered for the heat flux variation in each region. The proposed model is applied to the analysis of two-phase instability in a JAEA (Japan Atomic Energy Agency) 50MWt No.2 steam generator. The steady state results show that the proposed model accurately predicts the six cases of operating temperatures on the primary and secondary sides. The sizes of three regions, the secondary side pressure drop according to the flow rate, and the temperature variation in the vertical direction are also predicted well. The temporal variations of the inlet flow rate according to the throttling coefficient, the boiling and superheating boundaries and the pressure drop in the two-phase and superheating regions are obtained from the unsteady analysis.

Experimental Study of Nd:YAG Laser Cleaning System for Removing Acrylic Resin and Surface Characteristic (Nd:YAG 레이저를 이용한 금속유물에 코팅된 아크릴수지의 제거 및 표면 특성 연구)

  • Lee, Hye-Youn;Cho, Nam-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.4
    • /
    • pp.143-150
    • /
    • 2012
  • Laser cleaning have been found to be a useful cleaning tool to remove contaminants without inducing damage to the substrate and making secondary pollutant. In this study, the effect of Nd:YAG laser cleaning system, emitting at 1064 nm and 532 nm, on acrylic resin applied onto copper coupons and pieces of bronze was investigated. The samples after laser cleaning tests were examined using microscopy, FT-IR, SEM-EDS. As a result, the acrylic resin could be removed from most of the samples at low laser energy density. Laser wavelength 532 nm was more effective than 1064 nm because of using lower laser energy density, which could reduce heat damage to substrates. Although the acrylic resin was easily removed, it revealed melted surfaces and removed bronze patina which must remain. The problems should be solved by future studies using different laser system or laser wavelengths.

Performance Analysis of Passive Solar Chamber System (자연형 태양 챔버 시스템의 성능 분석)

  • Jang, Hyang-In;Kim, Byung-Gu;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.57-65
    • /
    • 2011
  • This study proposes a Passive Solar Chamber System (PSCS) as a passive method for reduction of building energy consumption. Through numerical analysis, the study quantitatively analyzes system performance and aims to provide foundational data for system design. For this purpose, the study configures different system operation modes seasonally and also computes thermal and ventilation performance of the system in accordance with design factors(solar radiation, air channel height and distance). System and ventilation efficiency increases along with increase in solar radiation and air channel distance; however, as the air channel height increases, the efficiencies showed a tendency to decrease. Upon installation of PSCS, an average of $98.23W/m^2$ of heat flux was introduced in the daytime for the month of January in comparison to walls with no PSCS installed. For the month of August, natural ventilation of $56.68m^3/h$ was shown to be supplied to the room.

Dynamic Characteristics of Thermal Stratification Build-up by Unsteady Natural Convection (비정상 자연대류에 의한 온도성층화의 동특성에 관한 연구)

  • Kang, B.S.;Lee, J.S.;Lee, T.S.;Ro, S.T.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.382-394
    • /
    • 1988
  • Dynamic characteristics of thermally-forced stratification process in a square enclosure with a linear temperature profile at the side walls have been investigated through flow visualization experiment and numerical analysis. The experiment was performed on air with the Rayleigh numbers of order $10^5$. A particle tracer method is used for the flow visualization and to obtain a sudden linear temperature profile at the side walls copper blocks which already have a linear temperature profile are come into contact with the thin copper plates of the test section. Immediately a meridional circulation is developed and heat transfer takes place from the wall to the interior region by circulation of fluid and finally a thermal stratification is achieved. In the numerical study, QUICK scheme for convective terms, SIMPLE algorithm for pressure correction, and the implicit method for the time marching are adopted for the integration of conservation equations. Comparison of flow visualization and numerical results shows that the developing flow patterns are very similar in dynamic nature even though there is a time lag due to the inevitable time delay in setting up a linear temperature profile. For high Rayleigh numbers, the oscillatory motion is likely to take place and stratified region is extended. However, initial temperature adjustment process is much slower than that for low Rayleigh numbers.

  • PDF