• 제목/요약/키워드: Heat-conservation

검색결과 370건 처리시간 0.023초

An Observational Study on the Differences in Thermal Characteristics of the Upo Wetland and Converted Areas from Wetland to Paddy Field

  • Koo, Hyun-Suk;Jeon, Dae-Youn;Kim, Hae-Dong
    • 한국지구과학회지
    • /
    • 제30권5호
    • /
    • pp.622-629
    • /
    • 2009
  • This study intended to collect data for evaluating the meteorological value of Upo Wetland which is the largest wetland in the downstream of Nakdong River. The observations were conducted in summer at the Upo Wetland and its surrounding paddy field that is the converted areas from a wetland to a paddy field. The following results are obtained: 1) The temperature of Upo Wetland area was $1^{\circ}C$ lower than the surrounding area during the day while it was a little higher during the night.; 2) The maximum wind speed in the Upo Wetland area was 3.5 m/s which is stronger than 1.6 m/s of its surrounding area. The south wind was observed in the farmland for most of the day while north winds and south winds alternated between day and night in Upo Wetland.; 3) In heat budget analysis, Upo Wetland was wasted in the form of latent heat rather than sensible heat in daytime.

Toward residential building energy conservation through the Trombe wall and ammonia ground source heat pump retrofit options, applying eQuest model

  • Ataei, Abtin;Dehghani, Mohammad Javad
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.107-120
    • /
    • 2016
  • The aim of this research is to apply the eQuest model to investigate the energy conservation in a multifamily building located in Dayton, Ohio by using a Trombe wall and an ammonia ground source heat pump (R-717 GSHP). Integration of the Trombe wall into the building is the first retrofitting measure in this study. Trombe wall as a passive solar system, has a simple structure which may reduce the heating demand of buildings significantly. Utilization of ground source heat pump is an effective approach where conventional air source heat pump doesn't have an efficient performance, especially in cold climates. Furthermore, the type of refrigerant in the heat pumps has a substantial effect on energy efficiency. Natural refrigerant, ammonia (R-717), which has a high performance and no negative impacts on the environment, could be the best choice for using in heat pumps. After implementing the eQUEST model in the said multifamily building, the total annual energy consumption with a conventional R-717 air-source-heat-pump (ASHP) system was estimated as the baseline model. The baseline model results were compared to those of the following scenarios: using R-717 GSHP, R410a GSHP and integration of the Trombe wall into the building. The Results specified that, compared to the baseline model, applying the R-717 GSHP and Trombe wall, led to 20% and 9% of energy conservation in the building, respectively. In addition, it was noticed that by using R-410a instead of R-717 in the GSHP, the energy demand increased by 14%.

대구지역의 기상조건에 따른 도시열섬강도의 계절별 변화특성 (On the Seasonal Variation of Urban Heat Island Intensity According to Meteorological Condition in Daegu)

  • 안지숙;김해동
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.527-532
    • /
    • 2006
  • The purpose of this study is to clarify the characteristic of urban heat island intensity in urban area formed at a basin. Thermal environments for basin-type cities are influenced by significant topographic relief winds. In this study, we analyzed the diurnal variations of the heat island intensity according to meteorological condition and season using AWS(Automatic Weather observation System) data in Daegu Metropolitan area for 1 year(3/April, 2003 $\sim$ 2/April, 2004). In this study, we defined the urban heat island intensity as the air temperature difference between two points, the downtown and the suburban area. The suburban area is located at valley mouth around the western tip of Daegu. The results are summarized as follows; 1. The maximum heat island intensity was recorded at early morning under the meteorological conditions, calm and clear 2. The heat island intensity was strong in the order of winter, fall, spring and summer. 3. The heat island intensity came out minus values in the afternoon. This phenomenon is known as a com mon for basin-type cities. 4. The heat island intensity was twice or more in clear and calm than not so.

Identification of Molecular Markers for Population Diagnosis of Korean Fir (Abies koreana) Vulnerable to Climate Change

  • Kim, Dong Wook;Park, Da Young;Jeong, Dae Young;Park, Hyeong Cheol
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • 제1권1호
    • /
    • pp.68-73
    • /
    • 2020
  • Korean fir (Abies koreana) is an evergreen coniferous tree species that is unique to South Korea. A. koreana is found in a limited sub-alpine habitat and is considered particularly vulnerable to climate change. Identification of populations vulnerable to climate change is an important component of conservation programs. In this study, a heat stress-induced transcriptome RNA-seq dataset was used to identify a subset of six genes for assessment as candidate marker genes for ecologically vulnerable populations. Samples of A. koreana were isolated from ecologically stable and vulnerable regions of the Halla and Jiri mountains, and the expression levels of the six candidate markers were assessed using quantitative real-time polymerase chain reaction. All six of the candidate genes exhibited higher expression levels in samples from vulnerable regions compared with stable regions. These results confirm that the six high temperature-induced genes can be used as diagnostic markers for the identification of populations of A. koreana that are experiencing stress due to the effects of climate change.

멀티 인버터 히트펌프의 동특성 해석 프로그램의 개발 (Development of the Dynamic Simulation Program for the Multi-Inverter Heat Pump Air-Conditioner)

  • 박병덕;이주동;;황일남;장세동;정백영
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1079-1088
    • /
    • 2001
  • A dynamic simulation model was developed to analyse the transient characteristics of a multi-inverter heat pump. The programs included a basic air conditioning system such as a evaporator, condenser, compressor, linear electronic expansion valve (LEV) and by-pass circuit. The theoretical model was derived from mass conservation and energy conservation equations to predict the performance of the multi-inverter heat pump at various operating conditions. Calculated results were compared with the values obtained from the experiments at different operation frequencies of compressor, area of the LEV and configuration of indoor units operation. The results of the simulation model showed a good agreement with the experimental ones, so that the model could be used as an efficient tool for thermodynamic design and control factor design of air-conditioners.

  • PDF

대구 앞산 달비골의 국지풍 특성에 관한 관측적 연구 (Observational Study on the Local Wind of the Dalbi-Valley Located at Ap-Mountain in Daegu)

  • 구현숙;권병혁;김해동
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.73-79
    • /
    • 2007
  • The purpose of this study is to clarify the effect of mountain-valley wind on heat island formed in urban area which is located around valley mouth. The meteorological observations were carried out over the Dalbi-valley under a clear summer pressure patterns, and some consideration were tried from the results. In order to make clear the climatological characteristics and air-mass modification process of the mountain-valley wind over the valley, the meteorological observations were done simultaneously at two points. The observational points were located at the breast and valley mouth parts, respectively. The results were as follows: First, it was found that the valley wind was observed through the daytime, and it was replaced by a mountain wind after sunset. Second, the heat budget is also investigated with observation data. The sensible heat flux over the breast of Dalbi-valley reached to about $200 W/m^2$ during daytime, which is a little more than one third of net radiation. On the other hand, the sensible heat flux represented negative values during nighttime. But the sensible heat flux over the valley mouth covered by asphalt showed plus value(about $20{\sim}30 W/m^2$) during the nighttime.

회전수 상승폭 변화에 따른 인버터열펌프의 비정상 운전특성 (A study on the transient characteristics during speed up of inverter heat pump)

  • 황윤제;김호영
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.495-507
    • /
    • 1998
  • The transient characteristics of a 4.0㎾ inverter driven heat pump was investigated by theoretical and experimental studies. The heat pump used in this study consists of a high side scroll compressor and $\Phi$7 compact heat exchangers with two capillary tubes. A series of tests was peformed to examine the transient characteristics of heat pump in heating and cooling mode when the operating speed was varied from 30Hz to 102Hz. One of the major issues that has not been addressed so far is transient characteristics during speed modulation. A cycle simulation model has been developed to predict the cycle performance under frequency rise-up conditions, and the results of theoretical study were compared with the results of experimental study. The theoretical model was driven from mass conservation and energy conservation equations to predict the operation points of refrigerant cycle and the performances at various operating speeds. For transient conditions, the simulated results are in good agreement with the experimental results within 10%. The transient cycle migration of the liquid state refrigerant causes a significant dynamic change in system. Thus, the migration of refrigerant is the most important factor whenever An experimental analysis is performed or A simulation model is developed.

  • PDF

대구의 토지이용도 유형에 따른 여름철 도시열섬포텐셜 추정연구 (Estimation of Urban Heat Island Potential Based on Land-Use Type in Summertime of Daegu)

  • 안지숙;김해동;김상우
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.65-71
    • /
    • 2007
  • This study aims to estimate a urban heat island potential distribution based on the land-use types using Landsat TM(1100 LST August 2004) and AWS data in Daegu. The heat island potential is defined as a difference between surface temperature and air-temperature at each place. The study area was selected as about $900km^2$ square including Daegu metropolitan area. Land-use data obtained by dividing all of Daegu metropolitan area in- to 1-km-square three types of maps were prepared in the 1960s, 1970s and 2000s respectively. Land-use types were classified into 5 categories. Forest and farm lands have been reduced at a wide range during 40 years. Most of those changed into urban area. The heat island potential distribution presented a striking contrasts according to land-use types. For example, the heat island potential of urban area was higher than $10^{\circ}C$ in comparison to those of water or paddy rice areas.

조선왕조실록 밀랍본 복원기술연구(제2보) - 실록의 복원용지 탐색을 위한 전통한지의 열화특성 평가 - (The Study of Restoration Technique of Wax-Treated Volume for the Annals of the Joseon Dynasty(II) - Evaluation of aging characteristics of Korean traditional paper, Hanji as the restoration material of the annals -)

  • 정선화;정소영;서진호
    • 펄프종이기술
    • /
    • 제40권2호
    • /
    • pp.43-56
    • /
    • 2008
  • The purpose of the experiment was to evaluate the material stability of the paper of the annals of Joseon Dynasty for the conservation purpose and the categories were as listed below : 1. Procuring traditional Hanji and semi-Hanji from different regional hanji paper mill. 2. Artificial accelerated aging treatment to examination its stability (UV irradiation, dry heat) 3. Analysis of optical, physical characteristic. The suitable Hanji for categories would be used as a reconstruction material for the waxel paper in the papers of the annals of Joseon Dynasty.

액적 충돌에 동반된 열전달에 관한 수치적 연구 (Numerical Study of Heat Transfer Associated with Droplet Impact)

  • 김성일;손기헌
    • 대한기계학회논문집B
    • /
    • 제28권9호
    • /
    • pp.1093-1100
    • /
    • 2004
  • Numerical analysis of the heat transfer associated with droplet impact on a hot solid surface is performed by solving the equations governing conservation of mass, momentum and energy in the liquid and gas phases. The deformed droplet shape is tracked by a level set method which is modified to achieve volume conservation and to include the effect of contact angle at the wall. The numerical method is validated through the calculations for the cases reported in the literature. Based on the numerical results, the heat transfer rate is found to depend strongly on the droplet spread radius. Decreased advancing/receding contact angles enlarge the splat radius and in turn enhance the wall heat flux. The effect of impact velocity on the droplet spread is reduced as the droplet size decreases. Also, droplet atomization is observed to significantly enhance the heat transfer rate and the effect is pronounced for a smaller size of droplet. An existing model equation to predict the maximum spread radius is improved for application to a micro droplet.