• 제목/요약/키워드: Heat vent

검색결과 72건 처리시간 0.02초

카본 세라믹 복합재 디스크의 벤트 구조 최적화를 통한 냉각성능 향상에 관한 연구 (A Study on Improvement of Cooling Performance through Vent Structure Optimization of Carbon Ceramic Composite Disc)

  • 심재훈;신웅희;이중희;전갑배;김병철;곽정후;임동원;현은재;전태형;이재만
    • 자동차안전학회지
    • /
    • 제11권1호
    • /
    • pp.23-29
    • /
    • 2019
  • Recently, use of composite materials has been increasing for body structures and chassis parts in the car industry because of weight reduction effect and excellent mechanical thermal characteristics. However, application of composite materials in brake system is very difficult because it is hard to obtain enough brake performance due to low heat storage capacity of the composite materials. In this paper, we will present new carbon ceramic composite disc with high flow characteristic. To obtain this characteristic, new vent structures were designed by using ARIZ method and substance-field model analysis. The flow effect of these vent structures on the brake performance was verified by pugh matrix and cooling test. The test results show improvement of cooling performance up to $30^{\circ}C$. Finally, These results will improve brake the reliability of the brake performance for the high performance vehicles and electric vehicles.

가압경수로의 저수위 운전시 잔열제거계통 상실사고에 대한 분석 (An Analysis of the Loss of Residual Heat Removal System Event for Pressurized Water Reactor at Reduced Inventory Operation)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.645-660
    • /
    • 1995
  • 표준원전을 대상으로하여 저수위 운전시의 잔열제거제통상실사고를 RELAP5/MOD3 및 RELAP5/MOD3.1 전산프로그램을 이용하여 분석하였다. 증기발생기가 이용가능할 때 원자로냉각재계통에 배기 경로가 없는 경우와 배기경로가 있는 경우에 대하여 분석을 수행하였다. 배기경로가 없는 경우에 대해 RELAP5 /MOD3 전산프로그램과 RELAP5 /MOD3.1 전산프로그램으로 비교 분석을 수행하였다. 분석 결과 두 전산프로그램의 계산결과는 정성적인 면 뿐 아니라 정량적 인면도 비교적 잘 일치하였다. 그러나 계산결과로부터 RELAP5 /MOD3의 경우에는 벽 열전달모델의 결함이 발견되어 배기경로가 있는 경우에 대해서는 RELAP5 /MOD3.1 전산프로그램을 이용하여 분석을 수행하였다. 분석결과 원자로정지후 하루가 지났을때 배기경로가 없는 경우에는 두개의 증기발생기로도 잔열이 충분히 제거되지 않아 원자로계통의 압력이 지속적으로 증가하여 사고개시 후4,000초 정도에 원자로계통의 임시밀봉재의 설계압력인 0.24MPa에 도달하였다. 가압기 안전밸브 용량의 세배정도 크기의 배기경로가 있는 경우에는 10,000 초가 지나도 원자로냉자재계통의 압력이 0.24 MPa에 도달하지 않았으며 노심노출이 초래되지 않았다. 분석결과의 상세한 검토를 통해서 저수위 운전시 잔열제거능력 상실사고가 발생하였을 경우 REL-AP5/MOD3.1을 이용한 사고해석 방법론의 타당성을 제안하였으며 또한 적절한 배기용량을 산정하기 위한 자료를 제공하였다.

  • PDF

전기오븐의 강제대류 열전달 특성 연구 (A numerical analysis of forced convection heat transfer in an electric oven)

  • 노선종;조성호;김형식;곽동성
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.124-128
    • /
    • 2011
  • The heat transfer rate in an oven is very important for the quality of cooking food. For a robust performance design in an electric oven, forced convection has been used rather than natural convection, in bake and convection mode. Forced convection heat trans for in a vented electric oven has been numerically evaluated using the commercial software FLUENT. CFD modeling of the electric oven involves three-dimensional, steady state, MRF fan model and DO radiation model. In this study, the electric oven cavity and fan modules are not simplified. Other research shows that the boundary condition can often lead to non-physical solutions, such as reverse flaw at the top vent. To remove this non-physical solution, control volume has been expanded at the nearby vent. This numerical analysis has been performed with dedicated experimental support. The results show that there is less than a 2.2% difference between the simulation and experimental data for the temperature profile of food. From this research we can use this oven simulation technique to make a better convection system in an electric oven.

  • PDF

토마토재배용 플라스틱온실의 이중피복방법에 따른 광합성유효광량자속 투과 및 열관류 특성 (Characteristics of PPF Transmittance and Heat Flow by Double Covering Methods of Plastic Film in Tomato Greenhouse)

  • 이현우;심상연;김영식
    • 한국농공학회논문집
    • /
    • 제52권5호
    • /
    • pp.11-18
    • /
    • 2010
  • This study was conducted to provide design data for deciding covering method in double layers greenhouse. The variation of photosynthetic photon flux (PPF) and heat flow in air inflated and conventional double layers greenhouse was analyzed. The PPF of air inflated double covering greenhouse was less than that of conventional greenhouse during summer season because the more PPF comes into conventional greenhouse through roof vent which was rolled up for ventilation. The air inflated double layers covering greenhouse was superior to conventional type in the aspect of controlling inside temperature down owing to lower irradiation. The PPF of air inflated greenhouse was greater than that of conventional greenhouse during winter season because the transmittance of conventional greenhouse decreased by dust collected on inside plastic film nearly closed for insulation. Considering the PPF not sufficient for tomato growing in winter, the air inflated double covering system with the greater transmittance was better than conventional covering system. When the inside air of air inflated greenhouse was injected into space between the double layers of covering, the PPF of air inflated greenhouse was much less than the conventional greenhouse because the transmittance of air inflated double covering decreased due to condensation of highly humidified inside air. It was concluded that the more dried outside air should be used for inflating double layers covering. The heat insulation performance of air inflated double covering system was superior to conventional double covering system when comparing the overall heat transfer coefficients for each covering method. However the differences among the overall heat transfer coefficients depending on difference between inside and outside temperatures of greenhouse were great, it is necessary to conduct additional experiment for investigating the overall heat transfer coefficient to design the double layers covering.

우도응회과의 분출기기구와 분출과정 (Eruptive mechanisms and processes at Udo tuff cone, Udo Island, Korea)

  • Hwang, Sang-Koo
    • 암석학회지
    • /
    • 제1권2호
    • /
    • pp.91-103
    • /
    • 1992
  • Eruptive mechanisms and processes at Udo tuff cone can be inferred from indicative characters of products, bedforms and lithofacies, and ring faults. In terms of bedforms and lithofa-cies in particular, massive lapilli tuff beds and chaotic lapilli tuff beds are derived from subaerial falls of aggregated tephra of wet tephra finger jets, occurring dominantly at the lower sequences of proximal part at the tuff cone. Crudely stratified lapilli tuff are derived from subaerial falls of slightly aggregated tephra of less wet tephra finger jets, whereas reversely graded lapilli tuff beds are from slightly disaggregated subaerial falls of continuous uprush. Both beds frequently occur in the middle sequences at proximal and near medial part of the tuff cone. Block and lapilli tephra lenses, ash-coated lapilli tephra beds(lenses) and thin-bedded tuff beds are derived from extremely disaggregated subaerial falls of dry tephra in the continuous uprush, frequently occurring at the upper sequences of medial part at the tuff cone. Udo tuff cone is a basaltic volcano emergent through the sea water surface while water could flood across or into the vent area. Emergence of the tuff cone was from the type-Surtseyan eruption characterized by earlier tephra finger jets and later continuous uprush columns of tephra with copious volumes of steam. Explosions began when boiling of wter produced a bubble column reducing the hydrostatic pres-sure, allowing exsolution of gases from the magma. This expansion of magma into a vesiculating froth fragmented the magma and permitted mixing of magma and water so that a more vigorous generation of steam could proceed. Tephra finger jetting explosions continued to build the crater rims, then remove water from the vent that their deposits flowed like slsurries until the continuous uprush explosion ensued. Continuous uprush explosions were associated with most rapid accumula-tion of tephra. The increasing volume rate led to partial removal of water from the vent area by the newly tephra ring so that more vigorous activity could be attended by a reducing water supply. This might restrain surplus of cold water entering the vent and thus enhance the vigour of the eruption by allowing optimal heat exchange. Eventually the crater became so deep and unsuported that piecemeal sliding, or massive subsidence on indipping ring faults, filled and closed the vent, and the cycle of explosions and collapse began anew.

  • PDF

회전하는 극저온 시스템의 단열 특성에 관한 실험적 연구 (Experimental of the Rotaing Cryogenic System)

  • 이창규;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.7-13
    • /
    • 2000
  • A rotating cryogenic system was designed similar to the cooling system for the rotor of a superconducting generator. The experimental rotor has an inner vessel which simulates the winding space of an actual superconducting rotor, and a torque tube of comparable design. This paper describes the evaluation of the total heat leak into the inner vessel that leads to the study of the heat transfer characteristic of the rotating cryogenic system. To examine the insulation performance of the experimental rotor. temperature was measured at each part of the system at various rotaing speeds from 0 rpm to 600 rpm. Total heat leak into the inner vessel was calculated by measuring the boil-off rate of liquid helium. Conduction heat leak to the inner vessel was obtained by the vent tube, and radiation heat leak was calculated by subtracting the conduction heat lent from the total heat leak. There seemed to be no rotaional dependency of total heat leak at least up 600 rpm.

  • PDF

엘리베이터 카 내부 기류분포에 관한 열 유동해석 (Thermal and Fluid Analysis on Air Distribution in a Elevator Car)

  • 정경택;이중섭
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.56-62
    • /
    • 2020
  • The purpose of this study is to observe the visualization of the flow field for air flow distributed in the car from the ventilation fan installed in the ceiling of the passenger elevator car through the numerical analysis using computational fluid dynamics. STAR-CCM+, which is a code used for the numerical analysis, was used to predict the airflow distribution inside the elevator car. The numerical analysis of the distribution of the air current in the elevator was carried out. As a result, the analysis results for each point and the visualization of the air current distribution and the temperature distribution in the elevator car and were obtained. It was found that heat transfer was actively occurring inside the car due to the influence of the flow field discharged from the ventilation vent installed in the ceiling in the elevator car, and especially the convection heat transfer of Model-2 was more active than that of Model-1. As a result, the temperature distribution inside the car was found to be relatively low. In addition, the temperature distribution at a cross-section of 1700mm height in the elevator car shows that Model-2 is the location of the ventilation vent which makes people feel more comfortable.

지하철 터널부로의 열 및 연기배출에 관한 연구 (A Study of Heat and Smoke Exhaust to Subway Tunnel Direction)

  • 이동호
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.1-8
    • /
    • 2004
  • This study aims to derive the operation method of a comprehensive ventilation system which is capable of providing passengers with safe exit paths from platforms in onboard fire situations. To accomplish this, the airflow distributions in subway platforms under 6 types of tunnel vent system were calculated in addition to having analyzed diffusion behaviors of smoke and heat exhaust in such states by performing 6 kinds of different ventilation scenarios in a 3-D Fire Dynamic Simulation (FDS) simulation model. In order to recommend the mechanical smoke exhaust operation mode, Subway Environmental Simulation(SES) is used to predict the airflow of the inlet and outlet tunnel for the subway station to clarify the safety evaluation fir the heat and smoke exhaust on subway fire events.

HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a)

  • 김영중;임장순
    • 태양에너지
    • /
    • 제17권2호
    • /
    • pp.3-11
    • /
    • 1997
  • 열펌프건조기는 증발기에 의한 냉각및 감습기능과 응축기에 의한 가열기능을 대류형건조기와 연계시킴으로써 필연적 손실로 분류되던 배기가 갖고 있는 현열과 잠열을 회수하여 재활용할 수 있는 이점이 있다. 본 연구에서는 HFC134a를 냉매로 사용한 배치형(batch type) 열펌프건조기를 설계제작하여 건조실의 유지온도, 공기의 바이패스비(bypass ratio), 냉매의 과열도를 일정하게 유지하고 정면풍속(face velocity)과 압축기속도를 변화시켜 건조기의 성능을 분석하였으며 정면풍속의 증가에 따라 열펌프의 성적계수는 증가하나 SMER(Specific Moisture Extraction Rate)은 감소하였다.

  • PDF

MIDLOOP Code Analysis of a ROSA-IV/LSTF Experiment for the Loss of Residual Heat Removal System Event During Mid- loop Operation

  • Han, Kee-Soo;Lee, Cheol-Sin;Park, Chul-Jin;Kim, Hee-Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.683-690
    • /
    • 1996
  • The MIDLOOP code has been developed for the evaluation of RES pressurization transients initiated from a loss-of-Residual Heat Removal System (RHRS) during mid-loop operation after reactor shutdown. It provides a fast running and realistic tool for studying parametrically the response of important plant parameters such as pressure, temperature, and level to various plant combinations of the primary side vent, makeup, and leakage procedures and the steam generator (SG) conditions. The code consists of ten nodes representing the primary and secondary sides of a nuclear power plant and can analyze the effect of air on the primary system pressurization and primary to secondary heat transfer. The analysis results of the MIDLOOP code are in good agreement with the ROSA-IV/LSTF experiment without opening in the RCS.

  • PDF