Analysis of the polychlorinated biphenyls in transformer oils using peak matching method (피크패턴법을 이용한 절연유 중 PCBs 분석)

  • Shin, Sun Kyoung;Kim, Hye-Jin;Chung, David;Jeon, Tae Wan;Kim, Jin Kyoung;Park, Seok Un;Chung, Young Hee;Chung, Il Rok
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.410-418
    • /
    • 2005
  • PCBs had numerous uses such as hydraulic fluid, heat exchange fluid, sealant, lubricant, and carbonless copy paper. They are most likely found in electric utilities, power stations, industrial facilities, electronic manufacturing plants, petrochemical plants, railroad systems, electric equipment repair facilities, mining sites (active or abandoned), and military camps. Due to its outstanding chemical and thermal stabilities and electrical insulation properties, the commercial and industrial products of PCBs, such as Aroclors, Kaneclors, Clophens, Phenaclors etc., had been widely used as thermal oil and transformer oil from 1930s until the 1970s. The transformer oils were analyzed as a main source of polychlorinated biphenyls (PCBs) emission into the environment. Qualitative estimation of oil extracts as carried out with Aroclor 1242, 1248, 1254, 1260. The transformer oils contained the pure and mixed of Aroclor 1242, Aroclor 1254, and Aroclor 1260. Also, commercial screening kit of 20 ppm and 50 ppm were applied to the transformer oil samples.

Study on an Absorption Heat Transformer Using Methanol-Glycerine System (메탄올-글리세린을 이용한 변형 흡수 열 펌프 연구)

  • 민병훈
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.237-242
    • /
    • 2000
  • 에너지 회수를 위한 변형 흡수 열 펌프 연구를 메탄올-글리세린을 이용하여 수행하였다. 이 물질의 상 평형 열역학 데이터를 이용하여 변형 흡수 열 펌프의 이론적 성능계수 값을 각 기관의 조업 조건에 따라 계산하였다. 70~8$0^{\circ}C$의 공업 폐열 온도를 가지고 4$0^{\circ}C$ 온도상승 시킬 때 성능계수 50% 이상을 얻을 수 있었다.

  • PDF

A Study on the Thermal Degradation Properties of Epoxy Resin for Cast Resin Transformer (몰드변압기용 에폭시 수지의 열 열화특성에 관한 연구)

  • Lim, Kyung-Bum;Nam, Ki-Dong;Kim, Ki-Hwan;Park, Su-Hong;Hwang, Myung-Hwan
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.44-48
    • /
    • 2008
  • In this paper, we measured a contact angle, surface resistivity and XPS to study the thermal aging characteristics of the epoxy resin for cast resin transformer. As a result of this experiment, we found that the contact angle increases up to $200^{\circ}C$ as it causes a re-crosslinking on the surface, but starts decreasing at $250^{\circ}C$ as it causes heat condensation. As a result of examining the oxygen/carbon peaks through the XPS analysis, we obtained a higher oxygen peak vs. carbon in the first untreated sample, but it showed the opposite trend after heat treatment. That rise in the carbon peak continued up to $200^{\circ}C$, but decreased again at the temperatures above. That's because it kept forming a stable surface structure up to $200^{\circ}C$ but its carbon combination got destroyed due to a rapid oxidization at $250^{\circ}C$. And a conduction path was formed easily with the hydrophile property caused by rapid surface activation.

Analysis of the Damage Patterns and Metal Structure of 3 Phase Mold Transformers to which Interlayer Short-circuits have Occurred (층간 단락된 3상 몰드변압기의 소손 패턴 및 금속 조직 해석)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.86-91
    • /
    • 2010
  • The purpose of this study is to analyze the damage patterns and metal structure of 3 phase mold transformers collected from places where accidents have occurred. Compared to an oil-immersed transformer, a mold transformer has the advantage of requiring a smaller installation area and can be kept clean, while its disadvantages include the fact that abnormal symptoms of an accident are difficult to discover and its repair is impossible. The capacity of the mold transformers collected from places where accidents have occurred was 200kVA with primary voltages being F23,900V, R22,900V, 21,900V, 20,900V, 19,900V, etc., as well as secondary voltages being 380V, 220V, etc. It was found from the analysis on the diffusion of combustion in the damaged mold transformers that fire occurred first inside the U-phase primary winding and that carbonization and heat were diffused to V-phase and W-phase in V-pattern. In addition, from the analysis on the cross-sectional structure of the metal of the melted high voltage winding using a metallurgical microscope, it was found that the boundary surface, voids, and columnar structure were formed when an interlayer short-circuit had occurred Therefore, even though it is not possible to find the cause for the occurrence of an interlayer short-circuit at the inner side of the primary winding, it is thought that, due to the thermal energy generated when the short-circuit occurred, the heat source was diffused to the upper side and outside, causing a secondary accident.

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

Absorption cooling R&D in Europe

  • Kuhn, A.;Petersen, S.;Riebow, D.;Sahin, D.;Ziegler, F.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.50-57
    • /
    • 2004
  • This article reviews absorption cooling R&D in Europe from the viewpoint of fundamentals, cycle development and applications. The review contains information on R&D, predominantly of public projects in the field of sorption cooling. We report on research which is performed in Europe with some stress on Germany. There is progress in fundamentals, thermodynamic cycle design, and also applications. In the fundamentals part the discussion about thermodynamics, working pairs, and heat and mass transfer is reflected. Today's discussion on thermodynamic cycles is not very strong. Main focus is on special solid sorption cycles, compression­sorption hybrids, and open cycles, In the applications part the chilling business is the main issue. Some interest is given to the improvement of efficiency on and the adaptation to low temperature waste heat use, but the stress is on the use of solar energy as heat source. The area of heat pumping for heating purposes is less prominent but not at all negligible. Finally, industrial heat pumping involves the reverse cycle (heat transformer, heat pump type Ⅱ) also, but there is no significant activity.

  • PDF

A study on an experimental basis a special character of insulating oil the use of a transformers (변압기용 절연유의 특성에 관한 실험적 연구)

  • Kim, Sung-Dae;Park, Il-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5188-5193
    • /
    • 2011
  • This research is for temperature control of insulating oil inside the transformer. After I designed and manufactured various systems using Peltier element, which was thermal element, and Heat pipe, which was a cooling system, without electric power. The optimum system could be made by applying them to the temperature control for the insulating oil. I could verify that the combination type of Heat pipe 100 W+ Peltier 100W has a more outstanding capacity than pure Heat pipe 300 W within 60 degrees Celsius through experiments. Through this, I verify that the method of a proper design is prominent, and make an attempt at contribution to power saving effect and more effective control of Distributing board by using this combination type.

Diagnostic Technique for Cast Resin Molded Transformer Windings Using Active Thermography

  • Lim Young-Bae;Jung Jong-Wook;Jung Jin-Soo;Cho Seong-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.376-380
    • /
    • 2006
  • Temperature distribution measured to estimate the condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current temperature. Because of passive thermography, without the external thermal stimulation, the difference in surface temperature between the region of interest and back ground shows that the results can apply only to the estimation or the monitoring for the condition of loose terminal and the overload pertaining to the rise in temperature. However, a thermal diffusion in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents a nondestructive test using this behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

Breakdown Characteristics for Insulation Design of HTS Transformer in Liquid Nitrogen

  • J.M. Joung;S.M. Baek;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.38-42
    • /
    • 2003
  • HTS transformer is promising one of HTS power applications to be commercialized in the near future. To realize the applications, insulation technology in the coolant, liquid nitrogen, should be established. So breakdown characteristics should be considered at insulation components; turn-to-turn, layer-to-layer, winding-to-winding, were investigated. Firstly breakdown strengths of Kapton films were compared with Kraft paper these are as turn insulator. And next the characteristics of surface flashover on FRP were measured and the influence on breakdown strength of bubble generated with joule heat was discussed with the shape of cooling channel between layers. Finally barrier effect at winding-to-winding was discussed.