• 제목/요약/키워드: Heat transformer

검색결과 121건 처리시간 0.023초

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성 (Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer)

  • 김신효;조대권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.48-55
    • /
    • 2014
  • UV 발생용 플래시램프의 전원공급장치는 강력한 아크방전을 유발하기 위하여 높은 승압 비를 갖는 전압변환회로를 가지고 있다. 일반적인 구조는 높은 승압비의 트랜스포머와 배전압정류방식(코크라프트 올튼 회로 등)으로 방전관의 절연을 파괴함과 동시에 방전관에 전류를 급격히 통과시키는 방식으로 구동한다. 이 때, 제논방전관의 방전특성상 입력전류를 제한하지 않으면 방전관의 과다 발열, 전극손실, 봉입기체의 산화가속 등으로 수명저하의 원인이 되므로, 반드시 방전관에 유입되는 전류를 제한해야 되며, 이를 Ballast라 하는데 일반적으로 인덕터나 저항을 사용하여 인입전류량을 제한한다. 트랜스포머의 자가 공진(self-resonance)을 이용하면 낮은 1, 2차권선 비에도 고유주파수의 전후에서 비교적 높은 피크 전압을 얻을 수 있다. 또한 트랜스포머의 특정주파수에서 고유임피던스 성분을 이용하여 출력전압을 필터링하면 제논방전관이 자가 발진방식으로 동작하므로 종래의 회로구성보다 간단하고 경제적인 아크방전 파워 스테이지의 구성이 가능하다.

구동조건에 따른 전자레인지 내부 온도 분포 (Temperature Distributions of Inner Microwave for Various Working Conditions)

  • 최윤환;김동균
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.792-797
    • /
    • 2010
  • 가정용 조리기구인 전자레인지는 구동시 필요한 고주파의 형성을 위하여 고전압 발생장치와 고 전압 축전지 등의 장치가 사용된다. 이 장치들은 높은 전압에서 구동되기 때문에 다량의 열에너지를 방출한다. 따라서 방출된 열에너지는 전자레인지 본체의 온도를 상승시키는 요인이 된다. 본 연구에서는 쿨링팬 구동조건과 열에너지 발생조건에 따른 전자레인지 내부의 온도 분포를 해석하였다. 해석결과 쿨링팬에서 유출되는 공기의 속도가 증가함에 따라 내부 온도가 감소하는 것을 확인하였으며 감소하는 정도를 정량적으로 분석하였다. 그리고 열에너지 방출량을 조정하여 내부 온도분포를 조사하였다.

열유동을 고려한 GIS 모선의 온도상승 예측 (Temperature Rise Prediction of GIS Bus Bar Considering Thermal Flow)

  • 김중경;오년호;이지연;한성진
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.742-747
    • /
    • 2009
  • Many works on the temperature distribution of power apparatus have usually done by coupled magneto-thermal analysis. Such a method can not consider the internal gas or oil flow in the power apparatus such as gas insulated switchgear, GIS bus bar, and power transformer. Moreover it can not show the internal temperature distribution of the power apparatus exactly. This paper proposes a coupled magneto-thermal-flow analysis considering Navier-Stokes equations. The convection heat transfer coefficient is calculated analytically by applying Nusselt number for natural convection and is applied to the boundary condition of proposed method. Temperature distribution of the GIS bus bar model considering thermal flow is obtained by the proposed method and shows good agreement with the experimental data.

Bi-2223/Ag 고온초전도 선재의 bubbling 제어에 관한 연구 (A Study on Bubbling Control of Bi-2223/Ag HTS tapes)

  • 하홍수;오상수;하동우;송규정;김상철;권영길;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2001년도 학술대회 논문집
    • /
    • pp.145-148
    • /
    • 2001
  • Bi-2223/Ag HTS tapes fabricated by PIT process are used to make the power transmission cable, motor, fault current limiter, transformer etc. But some problems are still remained as like bubbling, sausaging to got the high Jc. In this study. we carried out the experiment to prevent bubbling in the HTS tape. The bubbling mainly occurred when HTS tape was heat-treating. Therefore, additional vacuum annealing at 400 ~ $600^{\circ}C$and slowly ramp-up sintering method were used to decrease the bubbling. slowly ramp-up sintering was more effective to decrease the bubbling than the vacuum annealing, but Jc was also decreased after heat treatment. Optimum ramp-up sintering schedule was searched to get the high critical current and prevent bubbling at same time.

  • PDF

PDP 모듈의 소음 저감 (Noise Reduction of PDP Module)

  • Park, Sooyong;Lee, Seokyeong;Jaeman Joo;Junghun Kang;Sangkyoung O
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.326.2-326
    • /
    • 2002
  • A PDP(Plasma Display Panel) module consists of a discharge panel, a SMPS for power supply, driving boards for panel control, and a logic board. Driving boards supply high voltage pulses to induce glow dischargein the PDP panel. The electrical pulses excite the circuit elements and subsequentlyacoustic noises. The main sources of the noise in the circuit are the transformer of SMPS and the power MOSFET of driving boards, and the heat sinks often amplify the noise level. (omitted)

  • PDF

NMR 자석용 고온 초전도 내부 코일을 위한 플럭스 폄프에 대한 실험 (Experiment of Flux pump for High Temperature Superconductor Insert coils of NMR magnets)

  • 정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.15-20
    • /
    • 2001
  • This paper describes a model flux pump experiment recently performed at the MIT Francis Bitter Magnet Laboratory. The results of the model flux pump will be used in the development of a prototype flux pump that will be couple to a high-temperature superconductor (HTS) insert coil of a high-field NMR (Nuclear Magnetic Resonance) magnet, Such an HTS insert is unlikely to operate in persistent model because of the conductors low index(n) The flux pump can compensate fro field decay in the HTS insert coil and make the insert operate effectively in persistent mode . The flux pump, comprised essentially of a transformer an two switches. all made of superconductor, transfers into the insert coil a fraction of a magnetic energy that is first introduced in the secondary circuit of the transformer by a current supplied to the primary circuit. A model flux pump has been designed. fabricated, and operated to demonstrate that a flux pump can indeed supply a small metered current into a load superconducting magnet. A current increment in the range of microamperes has been measured in the magnet after each pumping action. The superconducting model flux pump is made of Nb$_3$ Sn tape, The pump is placed in a gaseous environment above the liquid helium level to keep its heat dissipation from directly discharged in the liquid: the effluent helium vapor maintains the thermal stability of the flux pump.

  • PDF

Electrical and thermal properties of polyamideimide-colloid silica nanohybrid for magnetic enameled wire

  • Han, S.W.;Kang, D.P.
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.428-432
    • /
    • 2012
  • Polyamidimide (PAI)-colloidal silica (CS) nanohybrid films were synthesized by an advanced sol-gel process. The synthesized PAI-CS hybrid films have a uniform and stable chemical bonding and there is no interfacial defects observed by TEM. The thermal degradation ratio of PAI-CS (10 wt%) hybrid films is delayed by 100 ℃ compared with pure PAI sample determined by on set temperature range in TGA. The dielectric constant of PAI-CS (10 wt%) hybrid films decreases with increasing CS content up to about 5 wt% but increases at higher CS content, which is not explained simply by effective medium therories (EMT). The duration time of PAI-CS (10 wt%) hybrid coil is 38 sec, which is very longer than that of pure PAI coil sample. The PAI-CS (10 wt%) hybrid film has a higher breakdown voltage resistance than the pure PAI film at surge environment and exhibits superior heat resistance. The PAI-CS (10 wt%) sample shows the advanced and stable thermal emission properties in transformer module compared with the pure PAI sample. This result illustrates that the advanced thermal conductivity and expansion properties of PAI-CS sample in the case of appropriate sol-gel processes brings the stable thermal emission in transformer system. Therefore, new PAI-CS hybrid samples with such stable thermal emission properties are expected to be used as a high functional coating application in ET, IT and electric power products.

LCD TV를 위한 새로운 구조의 고성능 및 저가형 Backlight 구동 전원 통합 시스템 (New High Performance and Low Cost Construction of Unified Power System for LCD TV Backlight Driver Circuitb)

  • 장두희;이재광;노정욱;홍성수;김진욱;이효범;한상규
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.23-30
    • /
    • 2009
  • 본 논문에서는 LCD TV의 인치에 따라 다르게 적용되는 기존의 PID(Power-Integrated Drive)시스템과 PSD(Power-Separated Drive)시스템을 검토하여, 두 시스템의 장점만을 모아 LCD TV 전원 시스템의 표준화가 가능한 새로운 방식의 구동 전원 통합 시스템을 제안한다. 제안 시스템은 가격 및 효율이 우수한 2단 구성으로 이루어져 있고, 안전규격을 만족하기 위하여 1:1 트랜스포머를 사용하였다. 인버터 부의 최적 동작을 위해 인버터 구동신호의 주파수와 시비율을 고정하고 펄스 개수를 제어하는 Pulse Count Modulation(PCM)방식을 채용 하였다. 제안 시스템의 인버터 단은 전 부하 범위에서 영전압 스위칭이 가능하여 스위치의 발열이 우수하고, 별도의 전류 평형 트랜스포머가 필요치 않으므로 Balance Coil의 삭제가 가능하다. 이로 인해 신뢰성이 높은 제품 구성이 가능하고, PCB Size 축소 및 제작 원가가 낮아지는 장점을 갖는다. 최종적으로 제안 시스템을 기존 시스템과 비교 및 실험적 검증을 통하여 제안 시스템의 우수성을 확인한다.

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.