• 제목/요약/키워드: Heat transform temperature

검색결과 98건 처리시간 0.029초

비정상 피복열선법 열전도도 측정시 시간-온도 특성에 대한 점근해 (Large Time Asymptotic Solution for Unsteady Heat Conduction Problem of Coated Hot-Wire Thermal Conductivity Measurement)

  • 배철호
    • 대한기계학회논문집
    • /
    • 제19권7호
    • /
    • pp.1684-1690
    • /
    • 1995
  • A large time asymptotic solution for an unsteady heat conduction problem of a coated hot wire thermal conductivity measurement process was theoretically found. The solution revealed that the slope of wire temperature versus logarthmic time, which is used to evaluate the thermal conductivity, remains unchanged for large values of time even if a layer of coating is present on the hot wire. The significance of this result is that the thermal conductivity of an electrically conductive fluid can be measured with a coated hot wire using the same conversion relation as for a bare wire.

Analysis of photothermal response in a two-dimensional semiconducting material thermally excited by pulse heat flux

  • Saeed, Tareq;Abbas, Ibrahim
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.469-476
    • /
    • 2022
  • A mathematical model of Lord-Shulman photo-thermal theorem induced by pulse heat flux is presented to study the propagations waves for plasma, thermal and elastic in two-dimensional semiconductor materials. The medium is assumed initially quiescent. By using Laplace-Fourier transforms with the eigenvalue method, the variables are obtained analytically. A semiconductor medium such as silicon is investigated. The displacements, stresses, the carrier density and temperature distributions are calculated numerically and clarified graphically. The outcomes show that thermal relaxation time has varying degrees of effects on the studying fields.

석유계 잔사유로부터 저온 2단 열처리를 이용한 메조페이스 핏치 제조 및 특성 (Preparation and Characterization of Mesophase Pitches from Petroleum Residues using Two-step Heat Treatment)

  • 조한주;정민정;이형익;이영석
    • 한국수소및신에너지학회논문집
    • /
    • 제27권4호
    • /
    • pp.421-430
    • /
    • 2016
  • To prepare mesophase pitches through low energy process, pyrolysis fuel oil with $AlCl_3$ has been modified using two-step heat treatment which is heat-treated at $330^{\circ}C$ for 3~5 h after pre-treatment at $250^{\circ}C$. The result of polarized optical microscope observation, mesophase is not observed in pitches carried out only pre-heat treatment. While mesophase content is significantly increased from 9% to 100% according to increasing secondary heat treatment time from 3 h to 5 h. Synthesizing of the mesophase pitch at low temperature of $330^{\circ}C$ is attributed to decrease of viscosity of the pitches carried out first heat treatment with $AlCl_3$. The result of Fourier-transform infrared spectroscopic analysis, it is expected that aromatization of aliphatic compounds is dominant at early secondary heat treatment, on the other hand, polycondensation reaction becomes dominant as secondary heat treatment time increases. Aromaticity and stacking height of the pitches secondary heat treated for 5 hours are more increased about 25% and 107%, respectively, than that of pitches carried out only first heat treatment.

퓨리에 변환 적외선 분광기를 이용한 수직 분광 복사율 측정 장치의 제작과 측정 (Construction and Measurement of Normal Spectral Emissivity Device using Fourier Transform Infrared Spectrometer)

  • 전상호;유남준;조재흥;박철웅;박승남;이근우
    • 한국광학회지
    • /
    • 제19권6호
    • /
    • pp.400-407
    • /
    • 2008
  • 퓨리에 변환 적외선 분광기(FT-IR)를 이용한 물질의 적외선 분광 복사율 측정 장치를 구축하고 이 장치의 성능을 평가하였다. 본 장치는 기준 흑체, 시료 가열로, 광학계, FT-IR로 구성되어 있으며, 측정 온도 및 파장 영역은 $200^{\circ}C{\sim}500^{\circ}C$$3.5{\mu}m{\sim}20{\mu}m$ 이다. 기준 흑체의 유효 복사율은 0.9993 이상으로 거의 1에 가까운 값을 나타내고 있었으며, 흑체의 분광 복사율에 대한 합성 상대 불확도는 0.69% 이하이다. $300^{\circ}C$에서 불투명한 알루미나, 흑연, 양극 처리된 알루미늄 시료의 수직 분광 복사율과, 금속(IMS200)의 표면 거칠기에 따른 복사율을 측정하였다. 금속(IMS200)의 표면 거칠기에 따른 복사율 변화는 거칠기가 증가할수록 증가하였다.

Thermal Behavior Variations in Coating Thickness Using Pulse Phase Thermography

  • Ranjit, Shrestha;Chung, Yoonjae;Kim, Wontae
    • 비파괴검사학회지
    • /
    • 제36권4호
    • /
    • pp.259-265
    • /
    • 2016
  • This paper presents a study on the use of pulsed phase thermography in the measurement of thermal barrier coating thickness with a numerical simulation. A multilayer heat transfer model was ussed to analyze the surface temperature response acquired from one-sided pulsed thermal imaging. The test sample comprised four layers: the metal substrate, bond coat, thermally grown oxide and the top coat. The finite element software, ANSYS, was used to model and predict the temperature distribution in the test sample under an imposed heat flux on the exterior of the TBC. The phase image was computed with the use of the software MATLAB and Thermofit Pro using a Fourier transform. The relationship between the coating thickness and the corresponding phase angle was then established with the coating thickness being expressed as a function of the phase angle. The method is successfully applied to measure the coating thickness that varied from 0.25 mm to 1.5 mm.

STD 11강 마모특성에 미치는 서브제로처리의 영향 (Effect of Cryogenic Treatment on Wear Resistance of STD 11 Steel)

  • 홍영환;송건
    • 열처리공학회지
    • /
    • 제16권3호
    • /
    • pp.134-140
    • /
    • 2003
  • Effects of cryogenic treatment and tempering temperature on the amount of retained austenite, hardness and wear properties has been investigated using alloy tool steel, STD 11. Cryogenic treatments were performed at the temperatures of $-100^{\circ}C$, $-150^{\circ}C$ and $-196^{\circ}C$, and tempering were performed at $200^{\circ}C$ and $530^{\circ}C$. It was shown that lower hardness value was obtained on high temperature ($530^{\circ}C$) tempering even after cryogenic treatment. And retained austenite was not entirely transformed to martensite after cryogenic treatment even at $-196^{\circ}C$, which was not consistent with the belief that $-80^{\circ}C$ was sufficient to entirely transform any austenite retained in the quenched microstructure. Austenite retained in cryogenic treated condition was completely transformed to martensite only after tempering at $530^{\circ}C$. As far as wear test conditions in this investigation, it was found that cryogenic treatments improved the sliding wear resistance, but improvement of wear resistance was not directly related with retained austenite contents. And it was found that predominent wear mechanisms of STD 11 steel were oxidation wear and adhesive wear In sliding wear conditions.

Nonlocal heat conduction approach in biological tissue generated by laser irradiation

  • Abbas, Ibrahim A.;Abdalla, Aboelnour;Sapoor, Hussien
    • Advances in materials Research
    • /
    • 제11권2호
    • /
    • pp.111-120
    • /
    • 2022
  • A novel nonlocal model with one thermal relaxation time is presented to investigates the thermal damages and the temperature in biological tissues generated by laser irradiations. To obtain these models, we used the theory of the non-local continuum proposed by Eringen. The thermal damages to the tissues are assessed completely by the denatured protein ranges using the formulations of Arrhenius. Numerical results for temperature and the thermal damage are graphically presented. The effects nonlocal parameters and the relaxation time on the distributions of physical fields for biological tissues are shown graphically and discussed.

실리콘 코팅을 이용한 poly(ethylene naphthalate) 고온용 방열 필름의 제조 (Preparation of Poly(ethylene naphthalate) Film Coated with Silicones for High Temperature Insulator)

  • 이수;나차수
    • 한국응용과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.167-173
    • /
    • 2007
  • The surface of poly(ethylene naphthalate) film applicable to high temerature insulator for convection microwave oven was modified with silicone coating solutions in the presence of silane crosslinking agent. The structure and properties of the PEN films were investigated by using Fourier transform IR spectroscopy, viscometry, microscopy, and tensile tests. The experimental results showed that the coating with silicone enhanced thermal stability up to $200^{\circ}C$, and slightly lowered the tensile strength and elongation of the PEN films. Judging from dimensional stability results the silicone coated PEN films can not be used for higher temperature insulator above $230^{\circ}C$. Serious dimensional contraction of films was obtained during heat treatment at $250^{\circ}C$ even for 1h. However, the surface of those films still have same chemical structure of silicones. Therefore, If we use PEN film prestretched at $230^{\circ}C$ as base one it will be possible to prepare a high temperature insulator up to $230^{\circ}C$. Conclusively, a silicone coated PEN film can be suitable for the application to convection microwave oven door insulator at high temperature up to $230^{\circ}C$.

박막에서 쌍곡선형 열전도 방정식에 의한 열전도 해석 (Analysis of Hyperbolic Heat Conduction in a Thin Film)

  • 정우남;이용호;조창주
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.540-545
    • /
    • 1999
  • 고전적인 Fourier 열전도 방정식은 극저온하에서 또는 아주 짧은 시간동안의 가열시 타당성이 없는 것으로 고려되었다. 이러한 조건하에서는 열전도파의 성질이 지배적이기 때문에 , 수정된 Fourier 법칙에 근거한 쌍곡선형 열전도 방정식이 도입되었다. 열전도에 대한 Fourier 모델과 쌍곡선형 열전도모델이 적분변환법과 함께 Green 함수방법을 이용하여 분되었다. 한쪽 표면에서 주기적인 표면가열을 하는 유한한 평판의 열유속 분포 및 온도분포의 해를 제시하였고 각가의 모델로부터 얻어진 결과를 서로 비교검토하였다. 쌍곡선형 열전도 방정식에서 유도된 열전도파는 매개물을 통해 전파되어 맞은편쪽의 단열표면에서 가열 표면쪽으로 반사하였으나 , 고전적인 Fourier 모델에 의한 열은 열적교란이 매개물의 전체에 걸쳐서 전달된 후 즉각적으로 무한한 속도로 열전파가 발생함을 보여주었다.

  • PDF

Heating Behavior of Silicon Carbide Fiber Mat under Microwave

  • Khishigbayar, Khos-Erdene;Seo, Jung-Min;Cho, Kwang-Youn
    • 한국세라믹학회지
    • /
    • 제53권6호
    • /
    • pp.707-711
    • /
    • 2016
  • A small diameter of SiC fiber mat can produce much higher heat under microwave irradiation than the other types of SiC materials. Fabrication of high strength SiC fiber consists of iodine vapor curing on polycarbosilane precursor and heat treatment process. The curing stage of polycarbosilane fiber was maintained at $150-200^{\circ}C$ in a vacuum condition under the iodine vapor to fabricate a high thermal radiation SiC fiber. The structure and morphology of the fibers were characterized by Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TG) and scanning electron microscopy (SEM). In this study, the thermal properties of SiC fiber mats under microwave have been analyzed with an IR thermal camera and its image analyzer. The prepared SiC fiber mats radiated high temperature with extremely high heating rate up to $1100^{\circ}C$ in 30 seconds. The fabricated SiC fiber mats were not oxidized after the heat radiation process under the microwave irradiation.