• 제목/요약/키워드: Heat transfer Coefficient

검색결과 1,587건 처리시간 0.027초

대체냉매 R407C 및 R410A를 이용한 슬릿휜-관 열교환기의 응축특성에 관한 연구 (An Experimental Study on Condensation Characteristics of Slit Fin-tube Heat Exchanger Using Alternative Refrigerants, R407C and R410A)

  • 전창덕;장경근;강신형;이진호
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.706-716
    • /
    • 2002
  • R410A and R407C are considered to be alternative refrigerants to R22 for the air-conditioners. Experimental investigation is made to study the condensation heat transfer characteristics of slit fin-tube heat exchanger using alternative refrigerants R410A and R407C. R407C, a non-azeotropic refrigerant mixture, exhibited a quite different condensation phenomenon from those of R22 and R410A and its condensation heat transfer coefficient was much lower than that of R22 and R410A. Between the R22 and R410A, the condensation heat transfer coefficient of R410A, near-azeotropic refrigerant mixture, was a little higher than that of R22. R410A also showed the lowest condensation pressure drop across the test section. For all refrigerants, the condensation heat transfer coefficient and pressure drop increase as the mass flux increases.

垂直平板에서의 强制對流 膜沸騰 流動의 熱傳達解析 (Analysis of forced convective laminar film boiling heat transfer on vertical surface)

  • 이규식;최영돈
    • 대한기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.425-436
    • /
    • 1987
  • 본 연구에서는 강제대류가 있는 층류막비등유동을 벽면온도와 주수속도를 변 화시키며 수치해석하여 열전달계수와 유동특성을 구하였고, 열력학적 상태량들을 일정 하다고 가정하는 경우가 열전달계수에 어떠한 영향을 미치는가를 검토한 결과, 열전달 계수는 주수속도에는 큰 영향을 받지 않으나, 벽면온도와 열력학적 상태량의 변화에는 상당히 큰 영향을 받는 것으로 나타나고 있다.

공랭형 수직평판 흡수기 액막에서의 열 및 물질전달에 관한 수치적 연구 (A Numerical Study on Heat and Mass Transfer in a Falling Film of Vertical Plate Absorber Cooled by Air)

  • 김선창;오명도;이재헌
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1071-1082
    • /
    • 1995
  • Numerical analyses have been performed to obtain the absorption heat and mass transfer coefficients and the absorption mass flux from a falling film of the LiBr aqueous solution which is cooled by cooling air. Heat flux at the wall is specified in terms of the heat transfer coefficient of cooling air and the cooling air temperature. Effects of operating conditions, such as the heat transfer coefficient, the cooling air temperature, the system pressure and the solution inlet concentration have been investigated in view of the local absorption mass flux and the total mass transfer rate. Effects of film thickness and film Reynolds number on the heat and mass transfer coefficients have been also estimated. Analyses for the constant wall temperature condition have been also carried out to examine the reliability of present numerical method by comparing with previous investigations.

소구경 원관내의 R-22 응축열전달에 대한 실험 (Experiments on R-22 condensation heat transfer in small diameter tubes)

  • 김내현;조진표;김정오;김만회;윤재호
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.271-281
    • /
    • 1998
  • In this study, condensation heat transfer experiments were conducted with two small diameter(ø7.5, ø4.0) tubes. Comparison with existing in-tube condensation heat transfer correlations indicated that the correlations overpredict the present data. For example, Akers correlation overpredicts the data upto 104%. The condensation heat transfer coefficient of the ø4.0 I.D. tube was smaller than that of the ø7.5 I.D tube; at the mass velocity of 300kg/$m^2$s, the difference was 12%. The pressure drop data of the small diameter tubes ware highly(two to six times) overpredicted by the Lockhart-Martinelli correlation. Subcooled forced convection heat transfer test confirmed that Gnielinski's single phase heat transfer correlation predicted the data reasonably well.

  • PDF

국산(國産) 저질무연탄(低質無煙炭) 연소용(燃燒用) 유동층(流動層) 연소로(燃燒爐) 개발(開發) 및 열효율(熱效率) 증대(增大)에 관한 연구(硏究) (A Study on the Augmentation of Thermal Efficiency and the Development for the Fulidized Bed Combustor Untilizing Korean Low Grade Anthracite Coals)

  • 이관석
    • 설비공학논문집
    • /
    • 제2권2호
    • /
    • pp.112-118
    • /
    • 1990
  • Characteristics of heat transfer in a smooth and finned tube located vertically in atmospheric fluidized bed combustor which uses low grade anthracite coals was studied. Experiments to investigate the characteristics of heat transfer between smooth and finned tube are carried out and the results depend on particle size, fluidizing air velocity and bed temperature are summarized. It is found that heat transfer coefficient of the smooth and finned tube increases with decrease in particle diameter and increase in bed temperature. Furthermore, it is noted that heat transfer coefficient increase at the first with increase in the velocity of fluidizing air and tends to decrease at a certain fluidizing air velocity. The increase of heat transfer coefficient for the finned tube is appeared to be increased in 30% compared to that for the smooth tube.

  • PDF

주형/주물 접촉면에서의 접촉열저항을 고려한 상변화문제에 관한 연구 (Numerical Analysis for Stefan Problem in Mold-Casting with Air-Gap Resistance)

  • 여문수;손병진;이관수
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.348-355
    • /
    • 1992
  • Casting structures and properties are determined by the solidification speed in the metal mold. The heat transfer characteristics of the interface between the mold and the casting is one of the major factors that control the solidification speed. According to Sully's research, the thermal resistance exists due to the air-gap formation at the mold-casting interface during the freezing process and the interface heat transfer coefficient is used to describe the degree of it. In this study, one-dimensional Stefan problem with air-gap resistance in the cylindrical geometry is considered and heat transfer characteristics is numerically examined. The temperature distribution and solidification speed are obtained by using the modified variable time step method. And the effects of the major parameters such as mold geometry, thermal conductivity, heat transfer coefficient and initial temperature of casting on the thermal characteristics are investigated.

액화가스용 기화기의 외측 열전달에 대한 수치해석 연구 (A Numerical Study on Heat Transfer of External Surface of Ambient Evaporators)

  • 서동민;고동국;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제16권1호
    • /
    • pp.116-119
    • /
    • 2017
  • In this paper, natural convection around the ambient evaporator was numerically studied using commercial computational fluid dynamics software. From the simulations, temperature and velocity fields around the evaporator were found as a function of evaporator size and liquefied gas flow rate. The heat transfer coefficient at the external surface of the evaporator was also calculated from the simulation results. In order to give the heat transfer coefficient for various conditions, correlation between Rayleigh number and Nusselt number was proposed.

  • PDF

Prediction of Forced Convective Boiling Heat Transfer Coefficient of Pure Refrigerants and Binary Refrigerant Mixtures Inside a Horizontal Tube

  • Kim, Min-Soo;Hong, Eul-Cheong;Shin, Jee-Young;Kyungdoug Min;Ro, Sung-Tack
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.935-944
    • /
    • 2003
  • Forced convective boiling heat transfer coefficients were predicted for an annular flow inside a horizontal tube for pure refrigerants and nonazeotropic binary refrigerant mixtures. The heat transfer coefficients were calculated based on the turbulent temperature profile in liquid film and vapor core considering the composition difference in vapor and liquid phases, and the nonlinearity in mixing rules for the calculation of mixture properties. The heat transfer coefficients of pure refrigerants were estimated within a standard deviation of 14% compared with available experimental data. For nonazeotropic binary refrigerant mixtures, prediction of the heat transfer coefficients was made with a standard deviation of 18%. The heat transfer coefficients of refrigerant mixtures were lower than linearly interpolated values calculated from the heat transfer coefficients of pure refrigerants. This degradation was represented by several factors such as the difference between the liquid and the overall compositions, the conductivity ratio and the viscosity ratio of both components in refrigerant mixtures. The temperature change due to the concentration gradient was a major factor for the heat transfer degradation and the mass flux itself at the interface had a minor effect.

HFC 순수냉매 및 3성분 혼합냉매의 수평관내 응축열전달 (Condensation Heat Transfer for Pure HFC Refrigerants and a Ternary Refrigerant Mixture Inside a Horizontal Tube)

  • 오종택;비원 영치
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.233-240
    • /
    • 2000
  • An experimental study of condensation heat transfer was performed for pure refrigerants HFC32, HFCI25, and HFC134a, and a ternary refrigerant mixture of HFC32/125/134a (23/25/52wt%). The heat transfer coefficients were measured inside a horizontal smooth tube 5.8 mm I.D. and 8.0 m long. The refrigerant temperature at inlet was 40 $^{\circ}C$, and the mass flux was varied from 150 to 400 $kg/m^2s$. As for the pure refrigerants, the heat transfer coefficient of HFC32/125/l34a decreased as the quality decreased. In addition, the heat transfer coefficient of HFC32/l25/134a was about 20 % lower than HFC 134a at a low mass flux but showed no reduction at a high mass flux. The heat transfer coefficient of ternary refrigerant mixtures was 30% lower on the average than that of the pure refrigerant.

알루미나 나노유체의 열전달 특성에 관한 실험적 연구 (Experimental investigation of heat transfer characteristics of alumina nanofluid)

  • 김영근;조선형;성용진;정한식;정효민
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권1호
    • /
    • pp.16-21
    • /
    • 2013
  • 나노유체란 유체 내에 금속 또는 비금속성 나노 크기의 입자를 분산시킨 것으로서 열전달율을 높이기 위해 다양한 곳에서 사용되어진다. 본 논문에서는 50 nm 크기의 알루미나를 증류수에 분산시켜 농도 및 유속에 따른 기본적인 열전달 특성을 알아보고자 하였다. 실험 결과 알루미나 나노유체의 농도가 증가할수록 평균 및 국소 열전달 계수가 증가하는 경향을 보였다. 또한 X/D=50~120 구간에서 6 Wt%의 나노유체의 국소 열전달 계수값이 증류수와 비교하였을 때 최대 37~46% 정도 높게 나타났다. 6 Wt% 농도에서 레이놀즈수가 1100~1300일 때 평균 열전달 계수가 증류수에 비해 큰 폭으로 증가함을 확인하였다.