• 제목/요약/키워드: Heat storage tank

검색결과 294건 처리시간 0.024초

빙축 및 냉방열과정중 냉각유체와 Ice Ball사이의 열적 특성에 관한 실험적 연구 (An Experimental Study on Thermal Characteristics between Cooling Fluid and Ice Ball during Charging and Discharging Precesses)

  • 박경원;박이동;황영규;김윤제
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 추계학술발표회 논문집
    • /
    • pp.193-205
    • /
    • 1996
  • This paper deals with experimental study on thermal characteristics that a cooling fluid is affected to ice ball as being measuring the temperature in storage tank and ice ball governing the rate of heat storage. Distributor was taken as inlet geometry factor. flow rate of cooling fluid which was a brine were 2, 4, and 6LPM, and 8, 10, and 12$^{\circ}C$ in the temperature difference for dynamic factors with respect to three ice ball types(103, 96, 76mm). In case of in flowing cooling fluid, since inertia force is suppressed by lower flow rate the amount of heat was transferred to ice ball by heat conduction high because density difference is high. And in case of larger ice ball, a long-term storage was available because reaching time at steady state is relatively long. consequently, smaller ice ball could be suitable to a short-term storage.

  • PDF

운량에 따른 태양열 시스템의 성능 분석에 관한 연구 (Study on the Performance Analysis of Solar Heating System with Cloud Cover)

  • 김원석;표종현;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1215-1219
    • /
    • 2009
  • In this study, the performance of solar assisted hybrid heat pump system with cloud cover were analyzed by using experimental method in spring season. It was consisted of concentric evacuated tube solar collector, heat medium tank, heat storage tank, heat pump, and so on. As a result, the solar radiation should be maintained over $4.1\;MJ/m^2$ in order to operate solar heating system for heating. Solar heat of collector wasn't affected by ambient temperature, but cloud cover has a big effect to collector efficiency. In addition, the collector efficiency is about 50-60%, and solar fraction is 40% for this system.

  • PDF

6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제3보 최적설계 및 경제성평가) (Verification Experiment and Analysis for 6kW Solar Water Heating System(Part 3 : Optimum Design and Economic Evaluation))

  • 최봉수;이봉진;강채동;홍희기
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.16-24
    • /
    • 2005
  • The goal of the present paper is to show the optimum design and operation conditions on 6 kW solar water heating system by using computer simulation with verified modelling. As the object functions, we took not only the amount of acquired and auxiliary heat but LCC, which has a relative importance and decisive role in economy. As expected, the maximum heat is acquired at the slope of collector with the equal degree to the latitude, facing the south. The capacity increase of the circulation pump and the storage tank lead to the increase of acquired heat and the decrease of auxiliary heat, but do not necessarily give economical advantages owing to additional electrical power consumption. In the present system, the minimum LCC can be obtained at the storage tank volume of 450 L and the mass flow rate of 0.344 kg/s.

자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구 (The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems)

  • 이동원;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

독립형 액화가스 저장탱크의 BOG 발생에 대한 실험적 분석 (Experimental Analysis of Boil-Off Gas Occurrence in Independent Liquefied Gas Storage Tank)

  • 차승주;배진호;이동하;김태욱;김슬기;이제명
    • 한국해양공학회지
    • /
    • 제32권5호
    • /
    • pp.380-385
    • /
    • 2018
  • With the tightening of environmental regulations (i.e., IMO Tier III), natural gas (NG) has been spotlighted as an eco-friendly fuel with few air pollutants other than nitrogen oxides (NOx) and sulfur oxides (SOx). For reasons of economic efficiency, it is mainly stored and transported in a liquid state at $-163^{\circ}C$, which is a cryogenic temperature, using a liquefied gas storage tank. Accordingly, it is necessary to reduce the boil-off gas (BOG) occurrence due to the heat flow according to the temperature difference between the inside and outside of the storage tank. Therefore, in this study, a BOG measurement test on an independent-type storage tank made up of SUS304L was carried out. The test results showed the tendency for BOG occurrence according to the temperature under different filling ratios.

자동차용 열전지에서 유로배열 효과 예측을 위한 열유동 수치묘사 (A Numerical Simulation of Heat and Fluid Flow for Predicting the Effect of Passage Arrangement in Automotive Heat Battery)

  • 이관수;권재웅;백창인;송영길;한창섭;김동진
    • 한국자동차공학회논문집
    • /
    • 제3권5호
    • /
    • pp.64-73
    • /
    • 1995
  • A numerical simulation of heat and fluid flow for predicting the effect of passage arrangement in automotive heat battery has been performed. The system is assumed to be a two-dimensional laminar flow and isothermal boundary is applied to the surface of the latent heat storage vessel. In the case of ideal heat battery the flow rate into each flow passage is evenly distributed. The various models are considered in the view of pressure drop and bulk temperature. The effects on the efficiency of the heat battery are examined by varying geometrical factors such as flow passage clearance, length of a inlet and outlet tank and the length of a latent heat storage vessel. The flow clearance is a very important -factor on the efficiency of a heat battery. As the flow passage clearance becomes narrow, the flow distribution becomes uniform and the bulk temperature increases, however the pressure drop is large. Therefore, optimal flow passage clearance has to be chosen. The present work can be used in optimizing heat battery efficiency.

  • PDF

LNG 저장탱크의 종합 열유동 해석프로그램 개발 (Program Development on the Thermofluidodynamic Analysis of LNG Storage Tanks)

  • 김호연;최성희;박영;이정환;윤익근;김동혁;하종만;주상우
    • 한국가스학회지
    • /
    • 제5권2호
    • /
    • pp.52-61
    • /
    • 2001
  • [ $100,000m^3$ ] 규모의 원통형 탱크에 저장되어 있는 초저온의 액화천연가스는 외부조건 및 운전모드에 따라 복잡한 유동양상과 열물성 변화를 보인다. 이런 현상은 LNG의 저장 및 운전조건과 탱크의 설계사양 및 열전달 특성에 크게 영향을 받으며, 또한 저장탱크내 LNG의 안정적 저장 및 공급에 영향을 미치게 된다. 따라서, 본 연구에서는 LNG 저장탱크의 외부조건에 따른 2차원 열전달 해석, 시운전시 초기 상온상태의 LNG 저장탱크를 냉각하기 위한 Cool Down 프로세스, 그리고 탱크내 LNG의 유입 및 상승을 고려한 주입프로 세스의 해석을 수행하였다. 또한, 혼합 LNG 저장에 대한 해석도 수행하였다. 이런 LNG저장탱크내의 전반적인 열유동에 대한 해석을 토대로 가시화된 종합적인 열유동 해석프로그램을 개발하였다. 본 프로그램의 개발은 탱크내 저장된 LNG의 열적 안정성 해석의 기술력 확보뿐만 아니라 실탱크의 기본설계에 이용할 수 있게 되었다.

  • PDF

시설하우스의 폐열을 이용한 열펌프시스템의 성능평가에 관한 연구 (A Study on the Performance Evaluation of Heat Pump System Using Waste Heat in Greenhouse)

  • 조기현;박윤철;고광수
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.35-41
    • /
    • 2015
  • This study was conducted to develop a heat pump system to utilize waste heat within the greenhouse during the daytime in winter season. The system runs at 8 am to 6 pm for the heat storage operation, and from 6 pm to 8 am of the next day for the heat radiant work. In the case of the heat storage operation, the average solar radiation was $168.3W/m^2$ with $16.3^{\circ}C$ outside temperature. The $COP_s$ of the system shows 4.59 in this operation mode. When the temperature goes up to $18.6^{\circ}C$, the system $COP_s$ reached at 5.10. On the other hand, the $COP_h$ of the system in heat radiation mode shows 2.63. In this case, the inside of the greenhouse temperature was reaches at $24.7^{\circ}C$ when the outside temperature was $12.9^{\circ}C$.

평만형 태양열 집열기 를 설치한 자연 순환식 급탕시스템 의 성능 에 관한 연구 (Performance of Natural Circulation Hot Water System with Flat-Plate Solar Collectors)

  • 윤석범;전문헌
    • 대한기계학회논문집
    • /
    • 제9권5호
    • /
    • pp.579-589
    • /
    • 1985
  • 본 논문의 모의 실험에 사용한 자연순환식 급탕 시스템과 지금까지 발표된 것 과의 차이점은 다음과 같다. 집열기의 집열성능 계산에 Close의 모델은 시스템의 평 균 온도를 이용하였으며, Mertol의 모델은 집열기의 성능을 일정하게 하여 자연순환식 급탕 시스템의 성능을 계산하였다. 그리고, Young의 모델은 집열기 입구 및 출구 유 체의 평균 온도로 집열기의 집열 성능을 계산하였다. Shitzer, Ong의 연구에서 밝혀 진 바와 같이 집열기 집열판의 온도와 유체 온도는 서로 다르므로, 본 논문에서는 이 것들에서 오는 오차를 줄이기 위해 집열기 순환 유체의 평균 온도와 집열판의 온도를 해석적으로 구하여 집열기의 성능과 순환 유체의 성질 계산에 이용하였다.

축열수조를 이용하는 열펌프식 난방의 특성에 관한 연구 (A Study on The Characteristics of Heat Pump Heating System Utilizing Heat Storage Tank)

  • 김효경;이기영;박문수;황인수
    • 대한설비공학회지:설비저널
    • /
    • 제16권4호
    • /
    • pp.392-405
    • /
    • 1987
  • A study of appling solar assisted heat pump heating system to Korean climatic charac-teritics has been undertaken through computer simulation using TRNSYS (A Transient System Simulation Program). It is insufficient for heating system composed of each of solar and heat pump system to supply heat met with heating load. So SAHP (Solar Assisted Heat Pump) heating systems which combined solar system with heat pump system are analized using the standard weather data of Korea. And SAHP heating systems are categorized into the series system in which the solar storage is used as the source for the heat pump, the parallel system in which ambient air is used as the source for the heat pump, and the dual source system in which the storage or ambient is used as the source depending on which source yields the lowest work input. These combined system are better than each of solar and heat pump heating system in view of thermal performance, and parallel system is most effective among these combined systems.

  • PDF