• Title/Summary/Keyword: Heat spot

Search Result 263, Processing Time 0.032 seconds

Numerical Study on the Phenomenon of Spontaneous Ignition of Coal Stockpile (저탄장 자연발화 현상의 수치해석적 연구)

  • Kim, Chul-Jin;Park, I-Sun;Sohn, Chae-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.721-727
    • /
    • 2010
  • The spontaneous ignition of coal stockpile causes serious safety and economic problems. Such spontaneous ignition occurs in coal stockpile when the rate of heat released by the oxidation of coal is greater than the rate of heat lost to the surroundings. In this study, a two-dimensional unsteady model is adopted for studying spontaneous ignition and the numerical results are compared with experimental results. The numerical results are in a good agreement with the experimental ones. Depending on the porosity, the internal maximum temperature, pressure, and oxygen mass fraction during spontaneous ignition are investigated. On the basis of the numerical results, the transient temperature variations for several shapes of coal stockpiles are analyzed. Further, the physical mechanisms of hot-spot formation and spontaneous ignition are analyzed.

Tensile properties and Spot Weldability of Trip High Strength Steel Sheet (Trip형 고장력강판의 인장성질 및 점용접성)

  • Kang, C.Y.;Kim, H.J.;Kim, C.G.;Lee, B.W.;Lee, M.Y.;Lee, G.H.;Kim, T.I.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.11 no.4
    • /
    • pp.295-304
    • /
    • 1998
  • The effects of retained austenite and carbon content in the retained austenite on the tensile strength-elongation balance and spot weldability of TRIP high strength steel sheet have been investigated. The retained austenite of granular type increased with increasing intercritical annealing and austempering temperature, and film type was increased with the increase of austempering time. The volume fraction of retained austenite increased with decreasing intereritical annealing temperature, and the maximum value was obtained at austempering temperature of $400^{\circ}C$. The values of tensile strength-elongation balance increased with decreasing intercritical annealing temperature and maximum value was obtained at austempering temperature of $400^{\circ}C$. The maximum value of tensile strength-elongation balance was obtained at a retained austenite content of about 12%. Tensile shear strength of the specimens with retained austenite was higher than that of the normalizing specimens. With increasing welding current and time, the tensile shear strengh and nugget diameter increased, while nugget thickness showed the peak value and then decreased. The optimum range of welding condition at the given welding pressure of 350kgf was 7~11kA and 10~15 cycles.

  • PDF

The Effects of Urban Stream Improving the Thermal Environment on Urban (도심하천이 도시 열 환경 완화에 미치는 영향)

  • Park, Jin-Ki;Park, Jong-Hwa;Na, Sang-Il;Beak, Shin-Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.760-760
    • /
    • 2012
  • 도심 지역은 인구집중, 토지 피복의 변화 및 교통량 증가 등의 인공열 배출원의 다양화 등의 요인에 의해 주변지역보다도 기온이 높은 도시 열섬(Urban Heat Island) 현상에 의해 독특한 도시기후의 특색을 보이게 된다. 일반적으로 도시 열 환경에 대한 연구는 도시 열섬의 강도나 현상을 파악하는데 집중되어 왔다. 최근 들어 도시 열섬 현상 완화 또는 개선을 위한 관심이 높아지면서 도시내에 존재하는 수면이나 녹지를 이용한 기후개선에 대한 연구가 진행되고 있다. 하천은 다양한 생물이 서식하는 공간이면서 생물의 다양성이 풍부한 생태계의 보고로 인간과 환경이 조화를 이루어 온 공간이기도 하다. 이와 같이 하천은 지역의 다양성과 특수성에 따라 가지고 있는 기능이 다양하다. 그 중 하천의 환경 기능은 많은 열용량을 축적시켜 수면의 온도상승을 적게 하여 하천의 온도는 물론 주변지역의 온도를 낮추는 역할을 하게 된다. 특히 흐르는 물은 대류와 혼합과정을 거치며 열을 운반할 수 있으므로 효율적인 축열체가 된다. 또한 하천의 물 등은 광의 투과성이 높기 때문에 표면에서는 반사되지 않고 수체 내에 열을 저장한다. 따라서 이러한 현상이 종합적으로 작용하여 도심하천은 도심지에서 높게 형성된 온도를 낮추는 냉각효과가 있다고 판단된다. 이러한 영향을 알아보기 위해 본 연구에서는 원격탐사 기법을 이용하여 도심하천이 도시 열완경 완화에 미치는 영향을 분석하였다. 분석을 위해 2009년 9월 6일 Landsat 7 ETM+ 위성영상을 이용하여 LST (Land Surface Temperature)를 추출하고, SEBAL (Surface Energy Balance Algori- thms for Land) 모델을 이용하여 지표면 열수지 성분을 추출하였다. 그 결과, 도심하천 주변의 온도가 도심지에 비해 $2{\sim}3^{\circ}C$ 정도 낮게 형성되었으며, 잠열은 주변 도심지에 비해 하천에서 높은 분포를 나타내었다. 그러나 하천 둔치나 하천 주변의 콘크리트, 아스팔트 및 나대지 등의 토지피복은 지표면 온도가 높게 형성되어 도심의 heat spot으로 작용하여 열 환경을 악화시키나 도심하천은 cool spot 작용을 하여 도심의 열을 완화하는 기능을 갖는 것으로 판단된다.

  • PDF

Analysis of Integration Factor Effect in Dynamic-Structure-Fluid-Heat Coupled Time Transient Staggered Integration Scheme for Morton Effect Analysis (모튼이펙트 해석을 위한 동역학-구조-유체-열전달 시간과도응답 연성해석 시차적분법에서 시상수 효과 분석)

  • Suh, Junho;Jeung, Sung-Hwa
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.77-86
    • /
    • 2019
  • The present study focuses on the effect of staggered integration factor (SIF) on Morton effect simulation results. The Morton effect is a synchronous rotordynamic instability problem caused by the temperature differential across the journal in fluid film bearings. Convection and conduction of heat in the thin film displaces the hot spot, which is the hottest circumferential position in the thin film, from -20 to 40 degrees ahead of the high spot, where the minimum film clearance is experienced. The temperature differential across the journal causes a bending moment and the corresponding thermal bow in the rotating frame acts like a distributed synchronous excitation in the fixed frame. This thermal bow may cause increased vibrations and continued growth of the synchronous orbit into a limit cycle. The SIF is developed assuming that the response of the rotor-lubricant-bearing dynamic system is much quicker than that of the bearing-journal thermal system, and it is defined as the ratio between the simulation time of the thermal system and the rotor-spinning period. The use of the SIF is unavoidable for efficient computing. The value of the SIF is chosen empirically by the software users as a value between 100 and 400. However, the effect of the SIF on Morton effect simulation results has not been investigated. This research produces simulation results with different values of SIF.

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Effects of Nd:YAG Laser Welding Parameters on Fatigue life of Lap Joint Structure in Stainless Steel (스테인리스강의 Nd:YAG 레이저 겹치기 용접부 피로수명에 미치는 용접변수의 영향)

  • Kim, Yang;Yang, Hyun-Seok;Park, Ki-Young;Lee, Kyoung-Don
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.69-75
    • /
    • 2008
  • Spot welding which use the main process for side block production of stainless steel railway vehicle is legged behind in laser welding about a quality and productivity. Although the laser welding has many potential advantages such as low heat input and aspect ratio of weld bead, its application to a new structural component still is required many engineering data including mechanical properties such as tensile, fatigue strength, etc on. Therefore, experimental analysis was carried out to understand the fatigue phenomena of different thickness stainless steel overlap joining panels by Nd:YAG laser welding. The fatigue life curves were obtained through fatigue tests with the various levels of applied load. The fatigue life is related with the parameters such as gap size and penetration depth through experiment. As the results, tensile strength and fatigue life were proportional in heat input level and gap was identified the major factor for fatigue life. Also we could know that deferent a-ferrite content at HAZ depend on welding heat input was important factor to determine a formation of initial crack and total fatigue life cycle.

Critical heat flux (CHF) in pool boiling under static and rolling conditions

  • Tanjung, Elvira F.;Albdour, Samah A.;Jeong, Yeon Uk;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.520-529
    • /
    • 2020
  • Experimental investigations were attempted to simultaneously observe the vapor behaviors and critical heat flux under static and rolling conditions. From visualization results, vapor initiated, grew, and detached individually in a vertical direction from the static heated surfaces (at 10, 20, and 30°). While under rolling motion, initiated vapor grew, and interacted with each other, resulting in forming a wider dry spot on the heated surface. Also, it was observed that the vapor drifted upward and stayed on the heated surface longer compared to under static condition. The faster the platform rolls, the longer the vapor stay on the heated surface, significantly decreasing the CHF. On the other hand, as the platform rolls slower (at high rolling period), CHF increases. CHF was decreased with increasing maximum rolling amplitude and inclination angle under both conditions (static and rolling). CHF under rolling conditions was noticed to be lower than under static condition except at maximum rolling amplitude of 10°. The bubble departure frequency at a maximum rolling amplitude of 10° was the highest among all of rolling amplitudes, thereby enhancing the CHF. These results indicate that rolling motion significantly affects vapor behaviors and CHF.

The Heat Transfer Analysis of the First Stage Blade (발전용 가스터빈 1단 동익 열전달 해석)

  • Hong, Yong-Ju;Choi, Bum-Seog;Park, Byung-Gyu;Yoon, Eui-Soo
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.30-35
    • /
    • 2001
  • To get higher efficiency of gas turbine, The designer should have more higher turbine inlet temperature (TIT). Today, modem gas turbine having sophisticated cooling scheme has TIT above $1,700^{\circ}C$. In the korea, many gas turbine having TIT above $1,300^{\circ}C$ was imported and being operated, but the gas with high TIT above $1,300^{\circ}C$ in the turbine will give damage to liner of combustor, and blade of turbine and etc. So frequently maintenance for parts enduring high temperature was performed. In this study, the heat transfer analysis of cooling air in the internal cooling channel (network analysis) and temperature analysis of the blade (Finite Element Analysis) in the first stage rotor was conducted for development of the optimal cooling passage design procedure. The results of network analysis and FEM analysis of blade show that the high temperature spot are occured at the leading edge, trailing edge near tip, and platform. so to get more reliable performance of gas turbine, the more efficient cooling method should be applied at the leading edge and tip section. and the thermal barrier coating on the blade surface has important role in cooling blade.

  • PDF

The Surface Hardening Characteristics of Hot work Tool Steel by CW Nd:YAG Laser (CW Nd:YAG 레이저에 의한 열간금형 공구강의 표면경화특성)

  • Shin H.J.;Yoo Y.T.;Ahn D.G.;Shin B.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.219-220
    • /
    • 2006
  • Laser surface hardening technologies have been used to improve characteristics of wear and to enhance the fatigue resistance for mold parts. The objective of this research work is to investigate the influence of the process parameters, such as power of laser and defocused spot position, on the characteristics of laser surface hardening for the case of SKD61 steel. CW Nd:YAG laser is selected as the heat source. The optical lens with the elliptical profile is designed to obtain a wide surface hardening area with a uniform hardness. From the results of the experiments, it has been shown that the maximum hardness is approximatly 740 Hv when the power, focal position and the travel of laser are 1,095 W, +1mm and 0.3 m/min, respectively. In addition, the hardening width using the elliptical lens was three time larger than that using the defocusing of laser beam.

  • PDF

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.