• 제목/요약/키워드: Heat fluxes

검색결과 366건 처리시간 0.024초

온수의 표면방출에 의한 2차원 비정상 난류 열확산 의 예측 (Prediction of 2-Dimensional Unsteady Thermal Discharge into a Reservoir)

  • 박상우;정명균
    • 대한기계학회논문집
    • /
    • 제7권4호
    • /
    • pp.451-460
    • /
    • 1983
  • Computational four-equation turbulence model is developed and is applied to predict twodimensional unsteady thermal surface discharge into a reservoir. Turbulent stresses and heat fluxes in the momentum and energy equations are determined from transport equations for the turbulent kinetic energy (R), isotropic rate of kinetic energy dissipation (.epsilon.), mean square temperature variance (theta. over bar $^{2}$), and rate of destruction of the temperature variance (.epsilon. $_{\theta}$). Computational results by four-equation model are favorably compared with those obtained by an extended two-equation model. Added advantage of the four-equation model is that it yields quantitative information about the ratio between the velocity time scale and the thermal time scale and more detailed information about turbulent structure. Predicted time scale ratio is within experimental observations by others. Although the mean velocity and temperature fields are similarly predicted by both models, it is found that the four-equation model is preferably candidate for prediction of highly buoyant turbulent flows.

역복사경계해석을 위한 다양한 조정기법 비교 (Comparison of Regularization Techniques For an Inverse Radiation Boundary Analysis)

  • 김기완;백승욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1288-1293
    • /
    • 2004
  • Inverse radiation problems are solved for estimating the boundary conditions such as temperature distribution and wall emissivity in axisymmetric absorbing, emitting and scattering medium, given the measured incident radiative heat fluxes. Various regularization methods, such as hybrid genetic algorithm, conjugate-gradient method and Newton method, were adopted to solve the inverse problem, while discussing their features in terms of estimation accuracy and computational efficiency. Additionally, we propose a new combined approach of adopting the genetic algorithm as an initial value selector, whereas using the conjugate-gradient method and Newton method to reduce their dependence on the initial value.

  • PDF

SLAG 박리성 평가 방법에 대한 고찰 (A study on the evaluation method for slag detachability)

  • 우유철;김희진
    • Journal of Welding and Joining
    • /
    • 제5권1호
    • /
    • pp.57-63
    • /
    • 1987
  • A method which can be used for evaluating slag detachability is proposed in this study. The proposed method was intended to get an absolute value for slag detachability, to give consistent value for a given welded joint, and finally to be simple to test. With a test fig made in this study, an impact by dropping a steel ball (13Kg in weight) is applied on the back side of an as-welded plate having a slag layer on the weld bead. Such impact applied forces the slag to drop off from the bead surface. In order to make a quantitative evaluation the amount of slag removed was measured with increasing the number of drops. Using this method six kinds of fluxes were evaluated in terms of the effects of flux type, basicity and weding variables on the slag detachability. As an initial result of this test, it was found that welding heat input affects the detachability significantly. Most importantly the evaluation made using the presently proposed method gives the same order of ranking as that of the actual practice done by a welder.

  • PDF

An Experimental Study of The Effects of The Mixing Vane on Air-water Mixed Flow

  • Kim, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.331-336
    • /
    • 1996
  • The effects of a mixing vane on air-water mixed flow have been experimentally studied in this work, to investigate the basic mechanisms that the mixing vane affects critical heat flux (CHF). Experiment was performed for various flow rates focusing on bubbly flow and annular flow patterns. Acrylic tube (1.7m long, 11 mm I.D.) and the split vane type mixing vane were used, and ring-type conductance probes were used to measure the liquid film thickness in annular flow. Experimental results show that, (a) bubbly-to slug flow transition and churn-to-annular flow transition occur respectively near the mixing vane compared to the tests without mixing vane, (b) in bubbly flow region, the mixing vane breaks the bubbles into smaller ones and forwards bubbles to the center region of the tube by the centrifugal force, (c) the liquid film thickness in annular flow is decreased near the mixing vane for mass fluxes.

  • PDF

타워형 태양열 흡수기의 열전달 특성 실험장치에 관한 연구 (Scale Down Design on Experiment Facility of the Water/Steam Receiver for Solar Power Tower)

  • 서호영;김종규;강용혁;김용찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.676-679
    • /
    • 2007
  • This paper describes an experiment facility to measure the circulation characteristics of a water/steam receiver at various heat fluxes. The natural circulation type receiver was considered in this study. The experiment facility was designed to satisfy circulation balance with an appropriate scale down. As a result, riser tube inner diameter was 7.4 mm and water circulation was 0.319 kg/s. Downcomer tube inner diameter by circulation balance was 9.52 mm and the quality was from 0 to 0.23.

  • PDF

A variational asymptotic approach for thermoelastic analysis of composite beams

  • Wang, Qi;Yu, Wenbin
    • Advances in aircraft and spacecraft science
    • /
    • 제1권1호
    • /
    • pp.93-123
    • /
    • 2014
  • A variational asymptotic composite beam model has been developed for thermoelastic analysis. Composite beams, including sandwich structure and laminates, under different boundary conditions are examined. Previously developed beam model, which is based on variational-asymptotic method, is extended to incorporate temperature-dependent materials experiencing large temperature changes. The recovery relations have been derived so that the temperatures, heat fluxes, stresses, and strains can be recovered over the cross-section. The present theory is implemented into the computer program VABS (Variational Asymptotic Beam Sectional analysis). Numerical results are compared with the 3D analysis for the purpose of demonstrating advantages of the present theory and use of VABS.

역복사경계해석을 위한 다양한 조정법 비교 (Comparison of Regularization Techniques for an Inverse Radiation Boundary Analysis)

  • 김기완;신병선;길정기;여권구;백승욱
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.903-910
    • /
    • 2005
  • Inverse radiation problems are solved for estimating the boundary conditions such as temperature distribution and wall emissivity in axisymmetric absorbing, emitting and scattering medium, given the measured incident radiative heat fluxes. Various regularization methods, such as hybrid genetic algorithm, conjugate-gradient method and finite-difference Newton method, were adopted to solve the inverse problem, while discussing their features in terms of estimation accuracy and computational efficiency. Additionally, we propose a new combined approach that adopts the hybrid genetic algorithm as an initial value selector and uses the finite-difference Newton method as an optimization procedure.

Critical Heat Flux under Forced and Natural Circulations of Water at Low-Pressure, Low-Flow Conditions

  • Kim, Yun-Il;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(1)
    • /
    • pp.315-320
    • /
    • 1995
  • The CHF phenomenon has been investigated for water flow under forced and natural circulation modes with vertical round tubes at low pressure and low flow condition. Experiments have been performed by using three different test sections for mass fluxes below 400 kg/㎡s under near atmospheric pressure. The experimental data for forced and natural circulation are compared with each other. To predict the flow rate at the two-phase region our test condition has been analyzed by RELAP5/MOD3 because the local two-phase condition inside the stainless steel tube cannot be directly measured. To predict the CHF with accuracy we have to consider the parameters at the single-phase region as well as the flow behavior at the two-phase region.

  • PDF

ESTIMATION OF SOIL MOISTURE WITH AIRBORNE L-BAND MICROWAVE RADIOMETER

  • Chang, Tzu-Yin;Liou, Yuei-An
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.26-28
    • /
    • 2008
  • Soil moisture plays an important role in the land-atmosphere energy balance because it governs the partitioning of energy through latent heat fluxes or evapotranspiration. From the numerous studies, it is evident that the L-band radiometer is a useful and effective tool to measure soil moisture. The objective of the study is to develop and to verify the soil moisture retrieval algorithms for the L-band radiometer system. Through the radiometer-observed brightness temperature, surface emissivity and reflectivity can be derived, and, hence, soil moisture. We collect field and L-band airborne radiometer data from washita92, SGP97 and SGP99 experiments to assist the development of the retrieval algorithms. Upon launching the satellite L-band radiometer such as ESA-sponsored SMOS (Soil Moisture and Ocean Salinity) mission, the developed algorithms may be used to study and monitor globe soil moisture change.

  • PDF

가로흐름 수성으로 방출되는 2차원 온배수 난류모형 (A Two-dimensional Turbulence Model for the Thermal Discharge into Crossflow Field)

  • 최흥식;정경태;소재귀;이길성
    • 한국해안해양공학회지
    • /
    • 제5권2호
    • /
    • pp.91-98
    • /
    • 1993
  • 본고는 정상류 가로흐름이 존재하는 천해역으로 방출되는 온수의 거동 예측을 위한 2차원 난류모형 개발을 기술한다. 모델 기본방정식은 수심적분된 연적 및 운동방정식, 에너지보존 방정식이 사용되며, SIMPLE로 알려진 교치기법으로 적분된다. 난류운동량 및 열확산항은 2차원 $ extsc{k}$-$\varepsilon$ 방정식으로부터 결정된다. 기존 실험결과와의 비교에서 천수역 Near-field 해역내 난류현상 재현에 유망한 기법임이 확인되었다.

  • PDF