• Title/Summary/Keyword: Heat exchanger performance

Search Result 1,178, Processing Time 0.046 seconds

A study on the performance of the finned tube heat exchanger affected by the frosting using CFD tool (전산해석을 이용한 착상이 핀튜브 열교환기 성능에 미치는 영향에 관한 연구)

  • Kim, Sung-Jool;Choi, Ho-Jin;Ha, Man-Yeong;Bang, Seon-Wook
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2738-2743
    • /
    • 2008
  • We conducted a study by computational simulation about the effects of frost thickness on the pressure drop and heat transfer characteristics as whole heat exchanger configuration changes. In order to perform the analysis for validation, we assumed that frost properties have constant values and the frost layers that are formed on the fin and tube surfaces are uniform. In order to find the constant thermal conductivity of frost layer, a variety of frost thermal conductivities are performed in our work and compared with the results by Lee et al. [4] and Yang et al. [5] proposed many experimental data about the 2-rows and 2-columns finned tube heat exchanger. The numerical results agreed well with the experimental data when frost conductivity is 0.07W/mK. After the validation had performed, we applied this procedure to the finned tube heat exchanger of domestic refrigeration and investigated the thermo-hydraulic characteristic of the heat exchanger affected by frost thickness according to the inlet velocities and temperatures of air considering the configuration change such as fin pitch.

  • PDF

Characteristics of Thermal Efficiency with Changing Distances Between Tubes for Heat Exchanger (열교환기 관사이의 거리변화에 대한 열효율 특성)

  • Kim, Jong-Min;Lee, Jae-Park;Lee, Seung-Ro;Lee, Chang-Eon;Kum, Sung-Min
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.177-181
    • /
    • 2010
  • There are various types of heat exchanger by its purpose and usage, but the important thing is making smaller size of heat exchanger with increasing of the performance of heat exchanger. However, when a burner exists in front of a heat exchanger like boiler, the thermal efficiency of heat exchanger is not only important, but the characteristics of pollutant emission should be considered. Therefore, in this study, a circular tube type of heat exchanger in front of premixed burne, which has a shorter of flame length than that of non-premixed burner and can control $NO_x$ and CO emission by adjustment of equivalence ratio, was installed. Consequently, characteristics of $NO_x$ and CO emission and thermal efficiency of heat exchanger were studied with changing distances between tubes and equivalence ratio, experimentally.

DESIGN ANALYSIS OF OFFSET STRIP FIN HEAT EXCHANGER

  • Bhowmik, Himangshu;Lee, Kwan-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2131-2136
    • /
    • 2008
  • The characteristics of heat transfer and pressure drop in an offset strip fin heat exchanger was studied with a steady-state three dimensional numerical model. Flow Reynolds number $Re_{dh}$ ranged from 10 to 3500 and Prandtl number Pr ranged from 0.7 to 50. The dimensionless performance factors, i.e. 'the pumping power factor F' and 'the heat transfer performance factor J' were analyzed and obtained a relationship between them. Finally, the prediction of F and J factors was generalized for different Prandtl numbers.

  • PDF

Effect of design factors on the performance of heat exchanger with a slit fin (슬릿휜형 열교환기의 성능에 대한 설계인자의 영향)

  • Yun, J.Y.;Lee, K.S.;Kim, H.Y.;Kang, H.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.210-220
    • /
    • 1997
  • This study is to systematically analyze the effect of various kinds of design parameters on heat transfer and pressure drop characteristics of heat exchanger with a slit fin. TAGUCHI method, known to us as a very reasonable tool in the parametric study, is employed in the present work. Experimental factors have been limited to seven cases, considering the production of sample and the cost. The 18 kinds of large scale models are made by compounding level on each factor and the heat transfer and flow characteristics on each model has been analyzed. The present results allow us to be able to quantitatively estimate the various parameters affecting the heat exchanger performance, and main factors for an optimum design of a heat exchanger have been selected. The optimum design value on each parameter was presented and the reproducibility on the results was guaranteed.

  • PDF

Thermal Performance of a Spirally Coiled Finned Tube Heat Exchanger Under Wet-Surface Conditions

  • Wongwises Somchai;Naphon Paisarn
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.212-226
    • /
    • 2006
  • This paper is a continuation of the authors' previous work on spiral coil heat exchangers. In the present study, the heat transfer characteristics and the performance of a spirally coiled finned tube heat exchanger under wet-surface conditions are theoretically and experimentally investigated. The test section is a spiral-coil heat exchanger which consists of a steel shell and a spirally coiled tube unit. The spiral-coil unit consists of six layers of concentric spirally coiled finned tubes. Each tube is fabricated by bending a 9.6 mm diameter straight copper tube into a spiral-coil of four turns. The innermost and outermost diameters of each spiral-coil are 145.0 and 350.4 mm, respectively. Aluminium crimped spiral fins with thickness of 0.6 mm and outer diameter of 28.4 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Air and water are used as working fluids in shell side and tube side, respectively. The experiments are done under dehumidifying conditions. A mathematical model based on the conservation of mass and energy is developed to simulate the flow and heat transfer characteristics of working fluids flowing through the heat exchanger. The results obtained from the present model show reasonable agreement with the experimental data.

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

Analysis of a Cryogenic Nitrogen-Ambient Air Heat Exchanger Including Frost Formation (착상을 고려한 극저온 질소-대기 열교환기의 해석)

  • 최권일;장호명
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.825-834
    • /
    • 2000
  • A heat exchanger analysis is performed to investigate the heating characteristics of cryogenic nitrogen by ambient air for the purpose of cryogenic automotive propulsion. The heat exchanger is a concentric triple-passage for supercritical nitrogen, and the radial fins are attached on the outermost tube for the crossflow of ambient air. The temperature distribution is calculated for the nitrogen along the passage, including the real gas properties of nitrogen, the fluid convections and the conductions through the tube walls and the fins. Since the wall temperature of the outer (ambient side) tube is very low in most cases, a heavy frost can be formed on the surface, affecting the heat exchange performance. By the method of the similarity between the heat and the mass transfer of moist air, the frost growth and the time-dependent effectiveness of the heat exchanger are calculated for various operating conditions. It is concluded that the frost formation can augment the heating of nitrogen during the initial period because of the latent heat, then gradually degrades the heat exchange because of the increased thermal resistance. Practical design issues are discussed for the flow rate of nitrogen, the velocity and humidity of ambient air, and the sizes of the fin.

  • PDF

Effects of Cladding and Antifreeze Solution on Cavitation Corrosion of AA3003 Tube of Heat Exchanger for Automobile

  • Young Ran Yoo;Seung Heon Choi;Hyunhak Cho;Young Sik Kim
    • Corrosion Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.203-214
    • /
    • 2024
  • A heat exchanger is a device designed to transfer heat between two or more fluids. In a vehicle's thermal management system, Al heat exchangers play a critical role in controlling and managing heat for efficient and safe operation of the engine and other components. The fluid used to prevent heat exchangers from overheating the engine is mostly tap water. Heat exchange performance can be maintained at sub-zero temperatures using a solution mixed with antifreeze. Although the fluid flowing through the heat exchanger can reduce the temperature inside the engine, it also has various problems such as cavitation corrosion. Cavitation corrosion characteristics in tap water and corrosion characteristics were evaluated in this study when antifreeze was added for test specimens where AA4045 was cladded on the inner surface of AA3003 tubes of a fin-type heat exchanger. The cavitation corrosion resistance of AA3003 was found to be superior to that of AA4045 regardless of the test solution due to higher corrosion resistance and hardness of AA3003 than those of AA4045. The cavitation corrosion rate of Al alloys increased with the addition of antifreeze.

A Comparison of Performance on the Orthogonal and Refraction Heat Exchanger Shape in Air Ventilation System (환기시스템의 굴절 및 평판형 열교환기 형상에 따른 성능비교)

  • Hyeon, Hyeong-Ho;Jeong, Byeong-Ho;Kim, Ji-won;Lee, Kang-yeon
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.7
    • /
    • pp.281-287
    • /
    • 2019
  • Application of heat recovery system applying air supply and cexhaust ventilation device essential in energy management system for the optimum ventilation system utilization and energy saving. This is a key element of infrastructure technology for high-efficiency energy buildings, because it can save heating and cooling energy in winter and summer. In this paper, heat transfer efficiency was simulated using paper, plastic, and aluminum materials that was examined to compare heat exchanger performance under uniform flow conditions. We tested heat transfer efficiengy according to the shape of two of that, one is orthogonal and the other is refraction shape. Based on the simulation results, it is expected to contribute to the production of high performance heat exchanger with heat transfer performance and pressure loss.

Performance Analysis of Energy-Slab Ground-Coupled Heat Exchanger (에너지슬래브 지중열교환기의 성능 분석)

  • Choi, Jong-Min;Sohn, Byong-Hu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.487-496
    • /
    • 2012
  • Recently, utilization of building foundations as ground-coupled heat exchangers has attracted much attention because they reduce the cost and enhance the heat transfer. The objective of this study is to evaluate the performance of energy-slab ground-coupled heat exchanger installed in a commercial building. In order to demonstrate the energy transfer characteristics of the energy-slab, experiments were conducted from October 2010 to September 2011. The 1-year measurement results showed that the mean EWTs of brine returning from the energy-slab were $9.6^{\circ}C$ in heating season and $24.9^{\circ}C$ in cooling season, which were in a range of design target temperatures. In addition, the geothermal heat pump system with the energy-slab showed on-off operation according to the setting temperatures of secondary fluid in water storage tank. The results also showed that the energy-slab extracted heat of 198.6 kW from the ground and injected heat of 318.9 kW to the ground, respectively.