• 제목/요약/키워드: Heat exchanger performance

검색결과 1,178건 처리시간 0.021초

열전소자가 적용된 냉·온수 매트용 전열 모듈의 기초 열설계에 관한 수치해석적 연구 (Numerical Analysis on the Thermal Design of a Heat Exchanger for a Cold & Hot Water Mattress Equipped with Thermoelectric Modules)

  • 양호동;박설현
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.113-121
    • /
    • 2021
  • In this study, the thermal characteristics of cold and hot water mattress units equipped with thermoelectric modules were investigated via numerical analyses. Cold and hot water mattress products that are currently in existence use manual methods requiring refrigerants to be added to the hot water boiler. However, the cold and hot water mattress units using thermoelectric modules can provide improved efficiency via energy savings and actively resolving environmental pollution problems. To determine the efficiency of the thermoelectric module, the mattress was modeled and its efficiency was analyzed for the cooling and heating processes using two 100-W-class and one 200-W-class thermoelectric modules, respectively. From the results of this study, it was confirmed that when two 100-W-class modules were used, the application area was larger than when a single 200-W-class module was used, with uniform temperature distribution and improved performance compared to existing products in terms of electrical energy.

벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가 (Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process)

  • 김재영;임호;우제민;조성호;문종호;이승용;이효진;이창근;이종섭;민병무;박영철
    • Korean Chemical Engineering Research
    • /
    • 제55권3호
    • /
    • pp.419-425
    • /
    • 2017
  • 본 연구에서는 벤치급 건식 $CO_2$ 포집 성능평가 장치에서 흡수반응기 내부의 구조와 형태에 따른 K-계열 흡수제(KEP-CO2P2, 한국전력공사 전력연구원)의 성능특성을 확인하였다. 흡수반응기 혼합영역(mixing-zone)에 구조와 형태가 다르게 제작된 두 종류의 열교환기가 적용되었으며, 각각 CASE 1과 CASE 2로 나뉘어 동일한 조업조건으로 연속운전을 수행하였다. 연속운전동안 흡수반응 온도는 $75{\sim}80^{\circ}C$, 재생반응 온도는 $190{\sim}200^{\circ}C$, 그리고 반응기체($CO_2$) 농도는 12~14 vol%으로 설정하였다. 특히 흡수제의 흡수능 비교를 위해 흡수반응기 혼합영역의 차압을 400~500 mm$H_2O$로 유지하며 운전하였다. 또한 반응 후 채집한 시료는 반응성 비교를 위해 TGA를 이용하여 물성분석을 하였다. CASE 1 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 64.3%, 2.40 wt%으로 산출 되었고, CASE 2 실험에서 $CO_2$ 제거효율과 동적흡수능은 각각 81.0%, 4.66 wt%으로 산출되었다. 또한 반응 후 흡수제에 대한 TGA 측정 결과의 무게감량을 이용하여 흡수제의 동적흡수능을 계산한 결과, CASE 1과 CASE 2 실험에서 반응 후 흡수제의 동적흡수능은 각각 2.51 wt%와 4.89 wt%으로 산출되었다. 결론적으로 동일한 조업조건에서 흡수반응기 내부에 삽입되는 열교환기의 구조와 형태에 따라 흡수제의 성능 차이가 있는 것을 확인하였다.

R718-R744용 캐스케이드 냉동시스템의 최대 성능 예측 (Prediction on Maximum Performance of Cascade Refrigeration System Using R717 and R744)

  • 노건상;손창효
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2565-2571
    • /
    • 2009
  • 본 논문은 시스템의 운전조건하에서 R717-R747용 이원냉동 사이클의 성능 분석에 대한 기초 설계자료를 제공하는 것이다. 본 논문에서 고려한 운전변수는 암모니아 고온사이클과 이산화탄소 저온사이클의 과냉각도, 과열도, 응축과 증발온도이다. 이원 냉동사이클의 성적계수는 과열도가 증가할수록 증가하는 반면, 과냉각도가 증가할수록 감소한다. 그리고, 이원 냉동사이클의 성적계수는 응축온도와 함께 증가하지만, 증발온도와는 반대로 감소한다. 따라서, 과열도, 과냉도, 응축과 증발온도는 본 시스템의 성적계수에 영향을 미치는 것을 알 수 있었고, 최대 성능계수와 최적의 증발온도에 대한 수학 방정식을 개발하기 위해 이러한 변수들을 포함시켜 다중 회귀분석을 통해 제안하였다.

환경조절장치(ECS)의 모델링 프로그램 개발에 관한 연구 (A Study on Modeling Program Development of an Environmental Control System)

  • 유영준;이형주;고성희;기자영
    • 한국추진공학회지
    • /
    • 제13권5호
    • /
    • pp.57-63
    • /
    • 2009
  • 본 논문에서는 항공기 POD용 환경조절장치의 개발을 위한 모델링 및 시뮬레이션에 관한 연구를 수행하였다. 먼저, 시스템 요구성능을 분석하여 ACM 방식의 환경조절장치를 구성하고 성능모사를 위한 모델링을 수행하였다. 다음으로 각 구성품의 개념설계를 위해 주요구성품의 성능변화에 따른 민감도를 분석하고 시스템 요구성능을 만족하는 설계점 성능을 결정하였다. 다양한 비행환경에서의 탈설계 성능 모사를 통해 전체 운용영역에서의 개념설계 타당성을 검토하고 천이 성능해석을 통해 동적 거동특성을 분석하였다.

$NH_3$ 냉동장치의 과열도 변화에 의한 성능 특성 연구 II -열교환기 타입 변경- (The Study on Performance Characteristics of $NH_3$ Refrigeration System for Various Degree of Superheat - Part II : The Change of Heat Exchanger Type -)

  • 하옥남;권일욱;전상신;이승재;정송태;하경수;윤갑식;이종인;홍경한
    • 설비공학논문집
    • /
    • 제17권4호
    • /
    • pp.297-302
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the $NH_3$ gas to study the performance characteristics of $NH_3$ refrigeration system by the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1,500 kPa to 1,600 kPa and for degree of superheat from $0^{\circ}C\;to\;10^{\circ}C$ at each condensing pressure. As a result of experiment, when the degree of superheat is $0^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

극저온 추진제 고밀도화 기술동향 및 적용방안 (Review of Cryogenic Propellant Densification Technology)

  • 조남경;한상엽;김영목;정상권
    • 한국추진공학회지
    • /
    • 제9권3호
    • /
    • pp.133-144
    • /
    • 2005
  • 기존 발사체 시스템의 성능을 향상시키는 방법의 하나로 액체산소와 액체수소와 같은 극저온 추진제를 고밀도화하는 기술이 최근 활발히 개발되고 있다. 극저온 추진제 고밀도화를 통하여 발사체에서 추진제의 질량분율을 높임으로 보다 큰 유상하중을 괘도에 진입시킬 수 있다. 본 논문에서는 극저온 추진제 고밀도화의 원리 및 최근 기술동향을 소개한다. 주로 액체산소의 고밀도화에 초점을 맞추어 여러 고밀도화 방법들에 대해서 소개하였다. 고밀도화된 극저온 추진제를 탑재한 발사체의 엔진 및 발사체 전체 성능해석 결과를 통하여, 발사체 시스템의 성능 향상을 정량적으로 소개하였다 또한 향후 극저온 추진제 고밀도화 기술의 국내 위성발사체 적용을 위한 방안을 간략히 제시하였다.

폐쇄형 해양온도차발전 사이클에 관한 연구 (A Study of Closed OTEC Power Plants)

  • 신상호;정동수;김종보;서태범;천원기;오정무
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.23-33
    • /
    • 1997
  • 본 연구에서는 Rankine 사이클을 이용한 해양 온도차 발전 시스템을 컴퓨터로 모사했고 작동유체를 변화시켜 가면서 그 성능을 비교하였다. 증발기와 응축기는 UA(총괄열전달계수$\times$전열면적)와 LMTD(대수평균온도차) 방법으로 모사하였으며 터빈과 펌프는 등엔트로피 효율로 모사하였다. 작동유체로는 R22, R290, R1270, R134a, R125, R143a, R32, R410A 그리고 암모니아 등을 사용하였다. 모사 결과 OTEC 발전 시스템의 효율은 작동유체에 상관없이 거의 일정한 것으로 드러났다. 한편 증발기 출구에서의 과열도와 응축기 출구에서의 과냉도는 시스템의 성능에 거의 영향을 미치지 않는 것으로 나타났지만 터빈의 효율과 열교환기의 크기는 시스템 성능에 큰 영향을 미치는 것으로 나타났다. 마지막으로 따뜻한 표층수와 차가운 심해수 사이의 온도차가 $20^{\circ}C$이상일 때 실제로 전기를 생산할 수 있다는 사실을 확인했다.

  • PDF

LNG 인수기지용 냉열발전 시스템 비교 연구 (A Comparative Study of the Cold Power Generation Systems for LNG Terminal)

  • 김동수;박영무
    • 에너지공학
    • /
    • 제5권1호
    • /
    • pp.34-41
    • /
    • 1996
  • LNG의 기화열(냉열)은 NG액화시 소모된 동력으로서 생산된 NG의 약 14%에 달한다. 평택 인수기지의 경우 '93도입물량 기준으로 냉열량은 96MW에 달한다. 냉열을 이용하여 전력을 생산하는 방안으로, 저온 엑서지를 활용하는 Rankine 사이클, 압력 엑서지를 이용한 부분직접 팽창 사이클 및 이 두 사이클의 혼합 사이클인 Linde공정 냉열발전시스템의 성능을 비교연구하였다. 시뮤레이션은 ASPEN Plus를 이용하여 수행하였으며 현재 인수기지에서 운영되고 있는 각종 설비들의 설계데이타를 이용하였다. 시스템별 출력은 약 3∼6MW였으며 최적운전조건의 엑서지 효율은 37%로 계산되었다. 또한 부분직접팽창방식의 최적 시스템을 제시하였고 열교환기의 총 면적이 동일 할 경우 부분직접팽창과 랭킨사이클의 성능은 비슷한 것으로 확인되었다.

  • PDF

열음향 냉장시스템 (II) : 제작 및 실험 (Thermoacoustic Refrigerating System, Part II : Implementation and Experiment)

  • 하재규;안철용;성굉모
    • 한국음향학회지
    • /
    • 제14권6호
    • /
    • pp.13-20
    • /
    • 1995
  • 본 논문에서는 열음향 냉장시스템을 실제로 설계, 제작하고 그 동작을 확인하였다. 제작된 시스템은 4인치의 중음부 스피커로 구동되며 스피커 하우징, 챔버, 스택하우징, 스택, 열교환기, 가는관, 그리고 공명구로 구성되었으며 내부에 10기압의 He을 채워 실험하였다. 실행 중 온도하강측정을 위하여 T 타입의 열전쌍을 열교환기에 부착하였고, 내부음압측정용 콘덴서 마이크로폰을 장착하였다. 스피커의 열손상을 막고 고온 열교환기를 냉각시키기 위하여 냉각수를 공급하였다. 실제 실험을 위하여 제작된 열음향기관의 전기적인 임피던스를 측정하여 공진특성을 파악하였는데, 실험 결과 설계치와는 약간 다르게 340Hz로 구동하는 것이 효율적이었다. 이러한 해석을 기초로 실제 냉장실험을 수행한 결과 $30^\circ{C}$의 조건하에서 340Hz, 50W로 구동하였을 때 $16^\circ{C}$의 냉장효과를 관찰하였다. 관찰된 냉각효과와 설계치의 차이를 규명하기 위하여 제작된 열음향기관의 미비점을 고찰하였는 바, 냉각부의 단열이 제일 중요한 문제임을 파악하였으며 그외의 보완이 필요한 사항은 이후의 진행될 연구의 과제로서 제시하였다.

  • PDF

차세대 원자로 정지냉각계통의 냉각 성능에 대한 연구 (A Study of Cooldown Performance of Shutdown Cooling System of Korea Next Generation Reactor)

  • 유성연;이상섭
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.525-532
    • /
    • 1999
  • 한국형 차세대 원자로는 ABB-CE사의 System 80+의 설계개념을 근간으로 하여 표준화된 원자로의 계통설계를 추진하고 있다. 본 연구에서는 차세대 원자로 정지냉각계통의 운전시 요구되는 인허가 요건등제반 조건을 충족시킬 수 있는지를 해석하였다. 또한 운전시 필요한 열교환기의 유효면적과 원자로 기기냉각수 유량등 기본적인 설계자료를 산출하여 차후 차세대 원자로 정지냉각계통의 상세설계 업부를 수행하는데 필요한 기초자료를 제시하여 핵증기공급계통 (NSSS)의 기술개발을 이루는데 목적이있다. 차세대 원자로는 울진 3, 4호기 열출력 2.825MWth 에 비해 열출력이 4,000MWth 로 증가되어 정지냉각계통의 관련서례자료를 새로 산출해야하므로 정지냉각계통의 냉각능력을 평가하는 KDESCENT 전산코드를 이용하여 원자로 노심의 잔열과 정지냉각계통의 현열을 제거할 수 있는 최소 유량을 제시하였으며 주요 구성기기인 열교환기, 펌프, 밸브 및 기타 기기의 기능 및 정지냉각계통의 운전절차를 고찰하였다.

  • PDF