작은 유로 내에서의 흐름응축 열전달 (I) -새로운 실험기법의 개발 - (Flow Condensation Inside Mini-Channels (I) -Development of New Experimental Technique-)

  • 신정섭;김무환
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1424-1431
    • /
    • 2004
  • With traditional experimental methods such as the secondary fluid (e.g., water) calorimetric method, it is very difficult to accurately test the local condensation heat transfer inside mini-channels. Hence, there are large discrepancies between the results of previous studies. The experimental methods as well as unidentified sources of uncertainties could be reasons for such discrepancies. In this study, innovative experimental techniques were developed to measure the in-tube condensation heat transfer coefficient. With these techniques, very low heat dissipation rates such as several watts from the mini-channel could be estimated and low mass flow rates below the 0.1 ㎏/h could be measured with reasonable uncertainties. To the authors' knowledge, these techniques provide a unique experimental apparatus for measuring the condensation heat transfer coefficients inside the sub-millimeter hydraulic diameter single channels.

IGBT 전력반도체 모듈 패키지의 방열 기술 (Heat Dissipation Technology of IGBT Module Package)

  • 서일웅;정훈선;이영호;김영훈;좌성훈
    • 마이크로전자및패키징학회지
    • /
    • 제21권3호
    • /
    • pp.7-17
    • /
    • 2014
  • Power electronics modules are semiconductor components that are widely used in airplanes, trains, automobiles, and energy generation and conversion facilities. In particular, insulated gate bipolar transistors(IGBT) have been widely utilized in high power and fast switching applications for power management including power supplies, uninterruptible power systems, and AC/DC converters. In these days, IGBT are the predominant power semiconductors for high current applications in electrical and hybrid vehicles application. In these application environments, the physical conditions are often severe with strong electric currents, high voltage, high temperature, high humidity, and vibrations. Therefore, IGBT module packages involves a number of challenges for the design engineer in terms of reliability. Thermal and thermal-mechanical management are critical for power electronics modules. The failure mechanisms that limit the number of power cycles are caused by the coefficient of thermal expansion mismatch between the materials used in the IGBT modules. All interfaces in the module could be locations for potential failures. Therefore, a proper thermal design where the temperature does not exceed an allowable limit of the devices has been a key factor in developing IGBT modules. In this paper, we discussed the effects of various package materials on heat dissipation and thermal management, as well as recent technology of the new package materials.

단면 변화가 있는 기주의 열음향진동에 관한 연구 (A Study on the Thermoacoustic Oscillation of an Air Column with Variable Cross Section Area)

  • 권영필;홍하표
    • 대한설비공학회지:설비저널
    • /
    • 제17권2호
    • /
    • pp.131-139
    • /
    • 1988
  • The thermoacoustic oscillation induced in an air column with variable cross section area is investigated theoretically and experimentally. The onset condition of the oscillation is derived by equating the acoustic power production to the power dissipation. The power production at the heater is predicted by using the efficiency factor obtained by heat transfer analysis for a single wire in a uniform cross flow and considering the interference between heater wires. The power dissipation is estimated by measuring the attenuating coefficient from the pressure decay curve. The theoretical prediction to the onset condition of the oscillation is confirmed experimentally. The effect of the variation of the column cross section area on the onset condition is presented.

  • PDF

EFFECTS OF SORET AND DUFOUR ON NATURAL CONVECTIVE FLUID FLOW PAST A VERTICAL PLATE EMBEDDED IN POROUS MEDIUM IN PRESENCE OF THERMAL RADIATION VIA FEM

  • RAJU, R. SRINIVASA
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권4호
    • /
    • pp.309-332
    • /
    • 2016
  • Finite element method has been applied to solve the fundamental governing equations of natural convective, electrically conducting, incompressible fluid flow past an infinite vertical plate surrounded by porous medium in presence of thermal radiation, viscous dissipation, Soret and Dufour effects. In this research work, the results of coupled partial differential equations are found numerically by applying finite element technique. The sway of significant parameters such as Soret number, Dufour number, Grashof number for heat and mass transfer, Magnetic field parameter, Thermal radiation parameter, Permeability parameter on velocity, temperature and concentration evaluations in the boundary layer region are examined in detail and the results are shown in graphically. Furthermore, the effect of these parameters on local skin friction coefficient, local Nusselt number and Sherwood numbers is also investigated. A very good agreement is noticed between the present results and previous published works in some limiting cases.

풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구 (A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine)

  • 최만수;장영학;박태식;정문선;문채주
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

다공성매질을 삽입한 수평채널의 열전달 및 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of a Horizontal Channel Filled with Porous Media)

  • 손영석;신지영;조영일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.244-251
    • /
    • 2009
  • Porous media have especially large surface area per volume, which contain complex fluid passage. If porous media can be applied to cool a CPU or an electronic device with large heat dissipation, it could result in heat transfer enhancement due to the enlargement of the heat transfer area and the flow disturbance. This study is aimed to identify the heat transfer and pressure drop characteristics of high-porosity metal foams in a horizontal channel. Experiment is performed with the various heat flux, velocity and pore density conditions. Permeabilities, which is deduced from Non-Darcy flow model, become lower with increasing pore density. Nusselt number also decreases with higher pore density. High pore density with same porosity case shows higher pressure loss due to the increase of surface area per unit volume. The fiction factor decreases rapidly with increase of Reynolds number in Darcy flow region. However, it converges to a constant value of the Ergun coefficient in Non-Darcy flow region.

플라스틱 관다발 타입 오일쿨러의 튜브 배열에 따른 열전달 특성 (Heat Transfer Characteristics according to the Tube Arrangement of Bundle Type Plastic Oil Cooler)

  • 허형석;배석정;김현철
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.87-94
    • /
    • 2007
  • It has been argued that the use of plastics can cause problems during design and manufacture owing to their low strength, relatively poor thermal conductivity and large thermal expansion. However, the advantages of plastics e.g., corrosion resistance, low cost, curtailment of weight, design flexibility etc., can compensate abundantly for the disadvantages. This study analyzes and compares the heat transfer performance characteristics of automotive compact oil cooler composed of plastic tube bundle with conventional metal oil cooler on the same core area basis as diameter, tube thickness, number of tube or tube arrangement varies. The performance analyses are accomplished by use of computational fluid dynamics program Fluent 6.2, which is verified and compared with the results of performance tests. The result of analyses is coincided with that of experiments. Flow pattern at air side according to tube arrangement is dominant factor which affects heat dissipation in case of similar total heat transfer surface area.

Thermomechanical Properties of Carbon Fibres and Graphite Powder Reinforced Asbestos Free Brake Pad Composite Material

  • Thiyagarajan, P.;Mathur, R.B.;Dhami, T.L.
    • Carbon letters
    • /
    • 제4권3호
    • /
    • pp.117-120
    • /
    • 2003
  • Asbestos is being replaced throughout the world among friction materials because of its carcinogenic nature. This has raised an important issue of heat dissipation in the non-asbestos brake pad materials being developed for automobiles etc. It has been found that two of the components i.e. carbon fibres as reinforcement and graphite powder as friction modifier, in the brake pad material, can playa vital role in this direction. The study reports the influence of these modifications on the thermal properties like coefficient of thermal expansion (CTE) and thermal conductivity along with the mechanical properties of nonasbestos brake pad composite samples developed in the laboratory.

  • PDF

Thaw consolidation behavior of frozen soft clay with calcium chloride

  • Wang, Songhe;Wang, Qinze;Xu, Jian;Ding, Jiulong;Qi, Jilin;Yang, Yugui;Liu, Fengyin
    • Geomechanics and Engineering
    • /
    • 제18권2호
    • /
    • pp.189-203
    • /
    • 2019
  • Brine leakage is a common phenomenon during construction facilitated by artificial freezing technique, threatening the stability of frozen wall due to the continual thawing of already frozen domain. This paper takes the frequently encountered soft clay in Wujiang District as the study object, and remolded specimens were prepared by mixing calcium chloride solutions at five levels of concentration. Both the deformation and pore water pressure of frozen specimens during thawing were investigated by two-stage loading tests. Three sections were noted from the changes in the strain rate of specimens during thawing at the first-stage load, i.e., instantaneous, attenuated, and quasi-stable sections. During the second-stage loading, the deformation of post-thawed soils is closely correlated with the dissipation of pore water pressure. Two characteristic indexes were obtained including thaw-settlement coefficient and critical water content. The critical water content increases positively with salt content. The higher water content of soil leads to a larger thaw-settlement coefficient, especially at higher salt contents, based on which an empirical equation was proposed and verified. The normalized pore water pressure during thawing was found to dissipate slower at higher salt contents, with a longer duration to stabilize. Three physical indexes were experimentally determined such as freezing point, heat conductivity and water permeability. The freezing point decreases at higher salt contents, especially as more water is involved, like the changes in heat conductivity. The water permeability maintains within the same order at the considered range of salt contents, like the development of the coefficient of consolidation. The variation of the pore volume distribution also accounts for this.

1.29 GHz 펄스파로 산출한 대기경계층 고도 (Atmospheric Boundary Layer Height Estimated based on 1.29 GHz Pulse Wave)

  • 서지우;권병혁;이경훈;이건명
    • 한국전자통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.1049-1056
    • /
    • 2023
  • 대기경계층 고도는 지면의 가열로 인해 발생한 난류가 경계층 내의 열, 수증기 등을 혼합하면서 생성되는 꼭대기로 일반적으로 열역학적 방법을 통해 결정한다. 윈드프로파일러는 대기 중으로 보낸 신호의 산란 정보로 대기의 정보를 산출한다. 윈드프로파일러 관측으로 대기경계층 깊이를 결정하기 위해 난류 성분의 스펙트럼 및 난류운동에너지 소산율, 굴절지수구조계수를 산출하는 방법을 제시하였다. 라디오존데 자료를 기반으로 산출한 온위와 비습의 연직 분포 특징과 비교하여 윈드프로파일러 산출물 기반의 대기경계층 고도 결정 방법이 매우 유용한 것으로 평가되었다.