• Title/Summary/Keyword: Heat detection

Search Result 440, Processing Time 0.03 seconds

Pre-detection Parameter of the Combustion Instabilities in the Gas Turbine Combustor (덤프형 가스터빈 연소기에서의 화염 불안정성의 사전 감지 인자)

  • Lee, Byeong-Jun;Santavicca, D.A.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.5
    • /
    • pp.750-756
    • /
    • 2002
  • The effect of equivalence ratio and velocity on the stability of flame in dump combustor was studied in an atmospheric pressure, laboratory scathe dump combustor operating natural gas. Traditionally, peak-to-peak pressure, fluctuation of the heat release rate and Rayleigh index were used to find and control the combustion instability. Cross correlation coefficients, Ci,j which is defined as the normalized value of the integration of the product of two of the mixer pressure, dump plane pressure and heat release rate, are introduced to see whether the flame is stable or not. Ci,j shows more sensitive to combustion status than Rayleigh index in steadily burning flame. Also, the result indicates that the amplitude of Ci,j between heat release and mixer pressure goes up before the flame at the rich de-stabilizing equivalence ratio near $\psi$=0.85. t means Ci:j at this case has a potential to detect the de-stablizing moment in prior to becoming unstable in dump combustor.

Liver metabolic perturbations of heat-stressed lactating dairy cows

  • Fan, Caiyun;Su, Di;Tian, He;Li, Xiaojiao;Li, Yu;Ran, Lei;Hu, Ruiting;Cheng, Jianbo
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.8
    • /
    • pp.1244-1251
    • /
    • 2018
  • Objective: The objective of the present study was to elucidate the mechanism underlying liver metabolic perturbations in dairy cows exposed to heat stress (HS). Methods: Liquid chromatography massabl spectrometry was used to analyze metabolic differences in livers of 20 dairy cows, with and without exposure to HS. Results: The results revealed 33 potential metabolite candidate biomarkers for the detection of HS in dairy cows. Fifteen of these metabolites (glucose, lactate, pyruvate, acetoacetate, ${\beta}$-hydroxybutyrate, fumaric acid, citric acid, choline, glycine, proline, isoleucine, leucine, urea, creatinine, and orotic acid) were previously found to be potential biomarkers of HS in plasma or milk, discriminating dairy cows with and without HS. Conclusion: All the potential diagnostic biomarkers were involved in glycolysis, amino acid, ketone, tricarboxylic acid, or nucleotide metabolism, indicating that HS mainly affected energy and nucleotide metabolism in lactating dairy cows.

Differential temperature fire detector analysis of comparative study based on sensor installation (차동식 열감지기 설치기준 비교분석에 관한 연구)

  • Hwang, Dong-Hwan;Yang, Kwang Mo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber (적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구)

  • Kang Byung Ha;Lee Jung Hoon;Kim Ho-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

A Defect Detection of Thin Welded Plate using an Ultrasonic Infrared Imaging (초음파 열화상 검사를 이용한 박판 용접시편의 결함 검출)

  • Cho, Jai-Wan;Chung, Chin-Man;Choi, Young-Soo;Jung, Seung-Ho;Jung, Hyun-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1060-1066
    • /
    • 2007
  • When a high-energy ultrasound propagates through a solid body that contains a crack or a delamination, the two faces of the defect do not ordinarily vibrate in unison, and dissipative phenomena such as friction, rubbing and clapping between the faces will convert some of the vibrational energy to heat. By combining this heating effect with infrared imaging, one can detect a subsurface defect in material efficiently. In this paper a detection of the welding defect of thin SUS 304 plates using the UIR (ultrasonic infrared imaging) technology is described. A low frequency (20kHz) ultrasonic transducer was used to infuse the welded thin SUS 304 plates with a short pulse of sound for 280ms. The ultrasonic source has a maximum power of 2kW. The surface temperature of the area under inspection is imaged by a thermal infrared camera that is coupled to a fast frame grabber in a computer. The hot spots, which are a small area around the defect tip and heated up highly, are observed. From the sequence of the thermosonic images, the location of defective or inhomogeneous regions in the welded thin SUS 304 plates can be detected easily.

Enzyme-linked Immunosorbent Assay for the Detection of Hen's Egg Proteins in Processed Foods

  • Shon, Dong-Hwa;Kim, Hyun-Jung;Kim, Soo-Ho;Kwak, Bo-Yeon
    • Food Science of Animal Resources
    • /
    • v.30 no.1
    • /
    • pp.36-41
    • /
    • 2010
  • The Hen's egg is widely used in many processed foods as an ingredient and is one of the most prevalent food allergens in children. To detect egg proteins in processed foods, we developed a competitive indirect enzyme-linked immunosorbent assay (ciELISA) using an anti-ovomucoid (OM) antibody, which was produced by immunization of rabbits with OM, the most heat-stable component of the egg proteins. The detection limit of this quantitative assay system was 30 ng/mL. Cross-reactivity of the anti-OM antibody toward OM, ovalbumin, skim milk, casein, whey protein isolate, and isolated soy protein was 100, 0.4, 0.2, 0.04, 0, and 0%, respectively. In the spike test of egg white powder in milk replacer, commercial sausage, and in-house sausage, the assay recoveries ($mean{\pm}SD$) were $129{\pm}13.7%$, $73.9{\pm}12.5%$, and $65.5{\pm}13.6%$, respectively. When egg white in a commercial crab meat analog and sausage was determined by ciELISA, the assay recovery was found to be 108% and 127%, respectively. The combined results of this study indicate that this novel ciELISA for OM detection could be applied for the quantification of hen's egg proteins in processed foods.

전자총 히터(electron gun heater) 자동검사를 위한 머신비젼 알고리즘

  • 김인수;이문규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.3
    • /
    • pp.58-67
    • /
    • 2000
  • Electron gun heaters are used to heat a cathode in video(TV) monitors. Major defects of the electron gun heaters include dimensional inaccuracy and pollution with dirty materials. In this paper, to save the labor and time being taken to inspect the heaters, a machine vision system is considered. For the system, a new algorithm is developed to measure the 9 different dimensions of each heater and to detect polluted defects. The algorithm consists of three stages. In the first stage, the center of the heater image is obtained and then its boundary detection is performed. For the efficient boundary detection, a mask called the sum mask is used. In the second stage of the algorithm, a set of fiducial points are determined on the boundary image. Finally, using the fiducial points specified dimensions are measured and the amount of polluted area is computed in the third stage. The performance of the algorithm is evaluated for a set of real specimens. The results indicate that measurements obtained by the algorithm satisfy the tolerance limits fur most of the dimensions and the algorithm detects the polluted defects successfully.

  • PDF

Defect Detection in Friction Stir Welding by Online Infrared Thermography

  • Kryukov, Igor;Hartmann, Michael;Bohm, Stefan;Mund, Malte;Dilger, Klaus;Fischer, Fabian
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.50-57
    • /
    • 2014
  • Friction Stir Welding (FSW) is a complex process with several mutually interdependent parameters. A slight difference from known settings may lead to imperfections in the stirred zone. These inhomogeneities affect on the mechanical properties of the FSWed joints. In order to prevent the failure of the welded joint it is necessary to detect the most critical defects non-destructive. Especially critical defects are wormhole and lack of penetration (LOP), because of the difficulty of detection. Online thermography is used process-accompanying for defect detecting. A thermographic camera with a fixed position relating to the welding tool measures the heating-up and the cool down of the welding process. Lap joints with sound weld seam surfaces are manufactured and monitored. Different methods of evaluation of heat distribution and intensity profiles are introduced. It can be demonstrated, that it is possible to detect wormhole and lack of penetration as well as surface defects by analyzing the welding and the cooling process of friction stir welding by passive online thermography measurement. Effects of these defects on mechanical properties are shown by tensile testing.

Highly Sensitive and Selective Gas Sensors Using Catalyst-Loaded SnO2 Nanowires

  • Hwang, In-Sung;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.167-171
    • /
    • 2012
  • Ag- and Pd-loaded $SnO_2$ nanowire network sensors were prepared by the growth of $SnO_2$ nanowires via thermal evaporation, the coating of slurry containing $SnO_2$ nanowires, and dropping of a droplet containing Ag or Pd nanoparticles, and subsequent heat treatment. All the pristine, Pd-loaded and Ag-loaded $SnO_2$ nanowire networks showed the selective detection of $C_2H_5OH$ with low cross-responses to CO, $H_2$, $C_3H_8$, and $NH_3$. However, the relative gas responses and gas selectivity depended closely on the catalyst loading. The loading of Pd enhanced the responses($R_a/R_g$: $R_a$: resistance in air, $R_g$: resistance in gas) to CO and $H_2$ significantly, while it slightly deteriorated the response to $C_2H_5OH$. In contrast, a 3.1-fold enhancement was observed in the response to 100 ppm $C_2H_5OH$ by loading of Ag onto $SnO_2$ nanowire networks. The role of Ag catalysts in the highly sensitive and selective detection of $C_2H_5OH$ is discussed.

A Study on Steady-State Criterion based on COV and a Fault Detection Method during GHP Operation (GHP 운전시 COV에 의한 정상상태 판별 및 이상검출 방법 연구)

  • Shin, Young-Gy;Oh, Se-Jae;Jeong, Jin-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.11
    • /
    • pp.705-710
    • /
    • 2011
  • Fault detection has to be proceeded by steady state filtering to get rid of transient effect associated with thermal capacity. Coefficient of variance (COV), ratio of standard deviation devided by moving average, was employed as steady-state filter. Engine speed and refrigerant pressures were selected as parameters representing system dynamics. The filtered values were registered as members of steady-state DB. They were found to show good functional relationship with ambient temperature. The relationship was fitted with a second order polynomial and the distribution bounds of the data around the fitted curve were expressed by visual inspection because of varying average and random data interval. Fault data were compared with the steady-state data obtained during normal operation. The fault data were easily isolated from the fault-free one. To make such isolation reliable, tests to construct good DB should be designed in a systematic way.