• Title/Summary/Keyword: Heat detection

Search Result 436, Processing Time 0.032 seconds

AI Automation Smart Access Management System using Personal Authentication and Heat Detector (AI자동화 개인 인증 및 발열 감지기를 이용한 스마트 출입 관리 시스템)

  • Lee, Hyo-Jai;Hong, Changho;Cho, Sung Ho;Kim, Eungsuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.272-274
    • /
    • 2021
  • Recently, due to COVID-19, the use of non-face-to-face authentication and fever detection systems is increasing. As the number of confirmed cases increases, the government is making it mandatory to authenticate and install a fever detector. It is used for entering and leaving not only general restaurants but also all stores. However, in most cases, the heat detector and the authentication device are separately configured and used, which is very inconvenient. Therefore, this study was conducted to develop an access control system that can simultaneously perform these functions. A smart access control system was developed by combining IOT technology as well as a fever detection function and smart personal recognition function. It is expected to further develop K-Quarantine by distributing it to public facilities and nursing facilities in the future.

  • PDF

Ovulation Synchronization in Water Buffaloes Guided by Milk Progesterone ELISA

  • Hoque, Md. Nazmul;Talukder, Anup Kumar;Kamal, Md. Mostofa;Jha, Ajit Kumar;Bari, Farida Yeasmin;Shamsuddin, Mohammed
    • Journal of Embryo Transfer
    • /
    • v.26 no.2
    • /
    • pp.105-109
    • /
    • 2011
  • Ovulation synchronization (ovsynch) has proved to increase the number of insemination in cattle by overcoming the problems of heat detection. The aim of this study was to do ovsynch in water buffaloes where heat detection is a major reproductive problem and to determine the conception rates after timed artificial insemination (TAI). Twenty cyclic buffaloes at ${\geq}$ 60 days postpartum were selected by examining 24 unobserved estrus buffaloes based on milk progesterone assay (progesterone concentration ${\geq}$ 1.0 ng/ml) from the Mymensingh district of Bangladesh. Ovsynch treatment regimen was started irrespective of the stage of estrous cycle. Gonadorelin (500 ${\mu}g$) was injected intramuscularly at Day 0 followed by Alfaprostol (8 mg) at Day 7. A second injection of Gonadorelin was given at Day 9 and TAI was done with frozen semen from Mediterranean buffalo bulls at 16~20 hours of the second Gonadorelin injection. Milk progesterone ELISA at Day 10~12 post AI confirmed ovulation in 16 out of 20 (80%) buffaloes (progesterone concentration ${\geq}$ 1.0 ng/ml). High progesterone concentration (${\geq}$ 1.0 ng/ml) at Day 10~12 and Day 22~24 of AI showed pregnancy in six out of 20 (30%) buffaloes. Pregnancy was further confirmed by ultrasonography at Day 40 in these six buffaloes. In conclusion, ovsynch followed by TAI could be applied in cyclic buffaloes for overcoming the estrus detection problems; however, more studies are needed to increase the conception rate.

Comparison of different ploidy detection methods in Oncorhynchus mykiss, the rainbow trout

  • Kim, Hong Seab;Chung, Ki-Hwa;Son, Jung-Ho
    • Fisheries and Aquatic Sciences
    • /
    • v.20 no.11
    • /
    • pp.29.1-29.7
    • /
    • 2017
  • The objective of this study was to determine a simple and reliable ploidy identification protocol for the rainbow trout (RT), Oncorhynchus mykiss, in the field condition. To evaluate the ploidy level and compare different detection protocols, triploid RT and gynogenesis were induced by UV irradiation and/or heat shock. The hatching rate at day 30 was 85.2% and the survival rate at day 90 was 69.4% (fingerling). The sex ratio of female RT was 93.75% in the gynogenesis group, illustrating that the UV irradiation inactivated the sperm DNA. The hatching rate and survival rate were 82.0 and 74.7%, respectively, in the triploid-induced group. The triploid induction rate by heat shock procedure was 73.9%. Cytogenetic protocols for ploidy identification such as chromosome counting, erythrocyte nuclear size comparison, and analysis of nucleolar organizing regions (NORs) by silver staining were compared. Silver nitrate staining showed the greatest success rate (22/23 and 32/32 for the triploid-induced group and gynogenesis group, respectively), followed by erythrocyte nuclear size comparison (16/23 and 19/32 for the triploid-induced group and gynogenesis group, respectively) and, lastly, chromosome preparation (2/23 and 6/32 for the triploid-induced group and gynogenesis group, respectively) with the lowest success rate. Based on our findings, silver staining for RT ploidy identification is speculated to be highly applicable in a wide range of research conditions, due to its cost-effectiveness and simplicity compared to other numerous ploidy detection protocols.

Defect Detection of Ceramic Heating Plate Using Ultrasound Pulse Thermography (초음파 펄스 서모그라피를 이용한 세라믹 전열 판의 결함 검출)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Kim, Seung-Ho;Jung, Hyun-Kyu
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.4 s.287
    • /
    • pp.259-263
    • /
    • 2006
  • The applicability of UPT (Ultrasound Pulse Thermography) for real-time defect detection of the ceramic heating plate is described. The ceramic heating plate with superior insulation and high radiation is used to control the water temperature in underwater environment. The underwater temperature control system can be damaged owing to the short circuit, which resulted from the defect of the ceramic heating plate. A high power ultrasonic energy with pulse duration of 280 ms was injected into the ceramic heating plate in the vertical direction. The ultrasound excited vibration energy sent into the component propagate inside the sample until they were converted to the heat in the vicinity of the defect. Therefore, an injection of the ultrasound pulse wave which results in heat generation, turns the defect into a local thermal wave transmitter. Its local emission is monitored and recorded via the thermal infrared camera at the surface which is processed by image recording system. Measurements were Performed on 4 kinds of samples, composed of 3 intact plates and the defect plate. The observed thermal image revealed two area of crack in the defective ceramic heating plate.

Detection of Poliovirus in Water by Cell Culture and PCR Methods (세포배양법과 PCR 방법에 의한 물에서의 폴리오 바이러스 검출)

  • 조연희;이찬희
    • Korean Journal of Microbiology
    • /
    • v.38 no.3
    • /
    • pp.198-204
    • /
    • 2002
  • Poliovirus is a member of enterovirus which causes paralytic poliomyelitis, encephalitis and aseptic meningitis. Since poliovirus is spread by the fecal-oral route and poliovirus-contaminated water could be a potential threat for public health, detection of poliovirus in drinking water resource is important. Infectious poliovirus and poliovirus inactivated by heat or UV were used to test three detection methods such as cell culture method, reverse transcription-polymerase chain reaction (RT-PCR) and integrated cell culture (ICC)-PCR. Infectious poliovirus was detected by all three methods and ICC-PCR was the most sensitive and fast in detecting poliovirus. Inactivated polioviruses could not be detected by cell culture or ICC-PCR methods. On the other hand, heat- inactivated viruses could be detected by RT-PCR. Thus it is suggested that ICC-PCR method is the most sensitive and effective in detecting infectious polioviruses in water sample.

Prevalence of pili and enterotoxins of Escherichia coli associated with diarrhea in preweaning piglets (포유자돈 소장에서 분리된 대장균의 섬모항원과 장내독소 분포양상)

  • Ham, Hee-jin;Cheon, Doo-sung;Chae, Chan-hee
    • Korean Journal of Veterinary Research
    • /
    • v.37 no.4
    • /
    • pp.779-784
    • /
    • 1997
  • A comprehensive study of 132 Escherichia coli isolates from 150 piglets with colibacillosis included detection of heat-labile enterotoxin, heat-stable enterotoxin, and identification of K88 (F4), K99 (F5), 987P (F6), and F41. Four pili were examined by haemagglutination and slide agglutination test. Heat-labile(LT) and heat-stable(ST) enterotoxin was determined by reverse passive latex agglutination and precipitation test, respectively. Among 132 E coli isolates, 26 had K88 (19.7%), 16 had K99 (12.1%), 3 had 987P (2.3%), and 2 had F41 (1.5%). Three had K88 and K99 (2.3%), 3 had K88 and 987P (2.3%), 2 had K99 and 987P (1.5%), 5 had K99 and F41 (3.8%), and 8 E coli strains had K88, K99 and F41 (6.1%) simultaneously. Among 132 E coli isolates, 5 produced LT only (3.8%), 55 produced heat-stable toxin ST only (41.7%), and 4 produced both LT and ST (3.0%). Three major pathotypes accounted for 27.9% of E coli isolates: $K99^+$ (8.3%), $K88^+ST^+$ (9%) and $K88^+$ (10.6%). Results of this study indicated that piliated enterotoxin-producing E coli was prevalent and was associated with diarrhea in preweaning piglets.

  • PDF

The Accuracy Analysis and Applied Field Research of a Newly Developed Automatic Heat Detector in Dairy Cow (젖소에 있어서 신개발 무인 발정탐색기의 정확도 분석 및 현장 적용 연구)

  • Back, Kwang-Soo;Lee, Wang-Shik;Park, Seong-Jai;Lim, Hyun-Joo;Son, Jun-Kyu;Kim, Sang-Bum;Kwon, Eung-Gi;Jung, Yeon-Sub;Kim, Kwang-Hyun
    • Reproductive and Developmental Biology
    • /
    • v.35 no.3
    • /
    • pp.395-398
    • /
    • 2011
  • The objective of this study was to compare the accuracy analysis and the effect of field application of a newly developed automatic heat detector in dairy cows. From 2009 to 2010, we used 48 Holstein cows (mounting cows : 38 heads, standing cows : 10 heads) raised in experimental barn of National Livestock Research Institute (RDA) for the accuracy analysis of automatic heat detector, and 14 Holstein cows raised in three commercial dairy farms of Cheonan and Pochun area for comparison of the effect of field application. The accuracy of response in cows attached with automatic heat detector was 86.8% (33/38) displayed on board when mounting activity observed, and 100% (10/10) when standing activity observed, and on average, 90.0% (43/48) displayed on board. The accuracy of automatic heat detector in on-farm test was 85.7% (12/14), and conception rate was 75.0% (9/12).

Detection of Heat Change in Urban Center Using Landsat Imagery (Landsat 영상을 이용한 도심의 열변화 탐지)

  • Kang, Joon-Mook;Ka, Myung-Seok;Lee, Sung-Soon;Park, Joon-Kyu
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.2
    • /
    • pp.197-206
    • /
    • 2010
  • Recently, developed countries have continuously been trying to recognize many issues about heat island in urban area and to make up countermeasures for them. This research is designed to extract change of land cover in the area under condition of land development with satellite images and to analyze its effect on the heat change in there. Heat change upon change of land cover in daejeon was analyzed with the four Landsat satellite images taken in April 1985, August 1994, May 2001, and May 2009. In order to measure the temperature on the surface in the city, the land surface temperature was produced with Landsat TM Band 6. Heat change is to detected with it. As a result, The urban area has been increased up to 23.59 percent. On the other hand, the forest area has been decreased up to 27.91%. Due to the urbanization, the temperature on the surface in urban center was higher than surrounding area. In that case, the temperature of urban center area was higher 2.4 to $5.7^{\circ}C$ compared with the forest area.

Test Bed Design of Fire Detection System Based on Multi-Sensor Information for Reduction of False Alarms (화재감지 오보 감소를 위한 다중정보기반 시스템의 Test Bed 설계)

  • Lee, Kijun;Kim, Hyeong Gweon;Lee, Bong Woo;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.107-114
    • /
    • 2012
  • Fire detection system is used for detection and alarm-generation of danger in case of fire. Most fire detection systems being used these days often malfunction from false positive and false negative errors. To improve detection reliability, an integrated fire detection algorithm using multi-senor information of heat, smoke and carbon monoxide detectors is suggested, then built and tested using the LabVIEW environment. Simulated using sensor measurement data offered by National Institute of Standards and Technology (NIST), possibility of reducing false positive and false negative errors is verified.

Test of Independence Between Variables to Estimate the Frequency of Damage in Heat Pipe (열수송관 파손빈도 추정을 위한 변수간 독립성 검정)

  • Myeongsik Kong;Jaemo Kang;Sungyeol Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.61-67
    • /
    • 2023
  • Heat pipes located underground in urban areas and operated under high temperature and pressure conditions can cause large-scale human and economic damage if damaged. In order to predict damage in advance, damage and construction information of heat pipe are analyzed to derive independent variables that have a correlation with frequency of damage, and a simple regression analysis modified model using each variable is applied to the field. However, as the correlation between independent variables applied to the model increases, the independence between variables is harmed and the reliability of the model decreases. In this study, the independence of the pipe diameter, burial depth, insulation level of monitoring system, and disconnection or short circuit of the detection line, which are judged to be interrelated, was tested to derive a method for combining variables and setting categories necessary to apply to the frequency of damage estimation model. For the test of independence, the continuous variables pipe diameter and burial depth were each converted into three categories, insulation level of monitoring system was converted into two categories, and the categorical variable disconnection or short circuit of the detection line status was kept as two categories. As a result of the test of independence, p-value between pipe diameter and burial depth, level of monitoring system and disconnection or short circuit of the detection line was lower than the significance level (α = 0.05), indicating a large correlation between them. Therefore, the pipe diameter and burial depth were combined into one variable, and the categories of the combined variable were set to 9 considering the previously set categories. The insulation level of monitoring system and the disconnection or short circuit of the detection line were also combined into one variable. Since the insulation level is unreliable when the detection line status is disconnection or short circuit, the categories of the combined variable were set to 3.