• Title/Summary/Keyword: Heat control unit

Search Result 189, Processing Time 0.025 seconds

An experimental study on performance evaluation for development of compact steam unit applied with hybrid plate heat exchanger (하이브리드 판형 열교환기 적용 컴팩트 스팀 유닛 개발을 위한 성능 평가에 관한 실험적 연구)

  • Park, Jae-Hong;Cho, Sung-Youl;Lee, Jun-Seok;Lee, Sang-Rae;Kim, Seung-Hyun;Lim, Gye-Hun;Seo, Jung-Wan;Kim, Jeung-Hoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.296-301
    • /
    • 2017
  • In various industrial places such as power generation plants, petrochemical and unit factories, the demands of systems that produce hot water by utilizing wasted or surplus steam have been increased. Compact steam unit(CSU) is a system that can meet these demands and produce hot water by using surplus or wasted steam, and it is also one of the good solutions in view of energy reuse. The new CSU with a capacity of 1,600 kW was developed with a hybrid plate heat exchanger of which thermal performances are better than a conventional plate heat exchanger, an improved temperature control valve, a user-friendly control system, and other components in this study. The purpose of this study was to obtain performance data of the new CSU through various experiments and utilize them for the CSU commercialization. The experimental results show that heat balances between the hot side(steam) and the cold side(cold water) were within ${\pm}0.77%$, and the fluctuations of outlet temperature of the secondary side which are one of the most important evaluation factors in the CSU were $(0{\sim}0.3)^{\circ}C$.

Effective Dynamic Models for the Development of Control Algorithms of a Condensing Gas Boiler System (콘덴싱 가스보일러시스템의 제어 알고리즘 개발을 위한 효과적인 동적모델)

  • Han, Do-Young;Kim, Sung-Hak
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.34-39
    • /
    • 2007
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, the effective operations and controls of the system are necessary. In this study, mathematical models of a condensing gas boiler system were developed and programmed in order to predict dynamic behaviors of the system. These include dynamic models for a blower, a gas valve, a pump, a burner, a boiler heat exchanger, and a hot water heat exchanger. Control algorithms for the control of a gas valve, a blower, and a pump were also assumed. Simulation results showed good predictions of the dynamic phenomena of a boiler system. Therefore, the simulation program developed for this study may be effectively used for the development of control algorithms of the boiler system.

  • PDF

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors (전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구)

  • 강환국;김재진;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF

CFD Analysis of a Concept of Nuclear Hybrid Heat Pipe with Control Rod (원자로 제어봉과 결합된 하이브리드 히트파이프의 CFD 해석)

  • Jeong, Yeong Shin;Kim, Kyung Mo;Kim, In Guk;Bang, In Cheol
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.109-114
    • /
    • 2014
  • After the Fukushima accident in 2011, it was revealed that nuclear power plant has the vulnerability to SBO accident and its extension situation without sufficient cooling of reactor core resulting core meltdown and radioactive material release even after reactor shutdown. Many safety systems had been developed like PAFS, hybrid SIT, and relocation of RPV and IRWST as a part of steps for the Fukushima accident, however, their applications have limitation in the situation that supply of feedwater into reactor is impossible due to high pressure inside reactor pressure vessel. The concept of hybrid heat pipe with control rod is introduced for breaking through the limitation. Hybrid heat pipe with control rod is the passive decay heat removal system in core, which has the abilities of reactor shutdown as control rod as well as decay heat removal as heat pipe. For evaluating the cooling performance hybrid heat pipe, a commercial CFD code, ANSYS-CFX was used. First, for validating CFD results, numerical results and experimental results with same geometry and fluid conditions were compared to a tube type heat pipe resulting in a resonable agreement between them. After that, wall temperature and thermal resistances of 2 design concepts of hybrid heat pipe were analyzed about various heat inputs. For unit length, hybrid heat pipe with a tube type of $B_4C$ pellet has a decreasing tendency of thermal resistance, on the other hand, hybrid heat pipe with an annular type $B_4C$ pellet has an increasing tendency as heat input increases.

Regulation of Heat-Stable Enterotoxin Production in Escherichia coli -1. Effeets of Phosphate, Ammonia, Glucose, and Glucose Metabolites on the Heat-Stable Toxin Production by Enterotoxigenic Escherichia coli- (대장균의 내열성장독소 생산조절기전 -I. 장독성대장균의 내열성장독소생산에 인산염, 암모니아, 포도당 및 포도당 대사산물이 미치는 영향-)

  • Kim, Ik-Sang;Hong, Tae-Yee;Lee, Woo-Kon;Chang, Woo-Hyun
    • The Journal of the Korean Society for Microbiology
    • /
    • v.20 no.1
    • /
    • pp.55-63
    • /
    • 1985
  • Phosphate, ammonia, glucosamine, glucose, pyruvate, succinate, fumarate, malate and acetate were examined for their ability to control the heat-stable enterotoxin (ST) production in succinate salts medium or in M9 medium. The results obtained were summerized as follows. 1. When the initial phosphate concentration was adjusted to 1.0mM, ST production was decreased to 80u/ml or less. But when the initial phosphate concentration was adjusted to 64mM or 100mM, enterotoxin production was 320u/ml. 2. When the initial ammonia concentration in the medium was adjusted to 1.0mM, no ST production and cell growth were observed. But when ammonia concentration was adjusted to 10mM, 19mM, 38mM or 76mM, enterotoxin production was 320u/ml. 3. Among carbon sources, glucosamine, glucose, pyruvate, succinate, fumarate, malate and acetate, acetate supported the highest specific production (928 unit/O.D.) of heat-stable enterotoxin. From this results, we could assume that heat-stable enterotoxin production is controlled by stringent control mechanism. 4. When the pH of the succinate salts medium was kept between 6.2 to 6.5, no heat-stable enterotoxin production was observed, but when the pH of the medium was kept between pH 6.2 to 6.5, 267 unit/O.D. of heat-stable enterotoxin was produced. 5. Glucose inhibited the heat-stable enterotoxin production and the mechanism was assumed due to its capacity to lower the pH of the medium during catabolysis and its high metabolic energy.

  • PDF

Heat Load Estimation-Based Switching Explicit Model Predictive Temperature Control for VRF Systems (시스템 에어컨의 온도 제어를 위한 부하 예측 기반 스위칭 모델 예측 제어)

  • Jun-Yeong Kim;S.M. Lee
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.3
    • /
    • pp.123-130
    • /
    • 2024
  • This paper proposes an EMPC (Explicit Model Predictive Controller) for temperature tracking control based on heat load prediction by an ESO (Extended State Observer) for a variable cooling circulation system with multiple indoor units connected to one outdoor unit. In this system, heat transfer and heat loss relative to the input temperature are modeled using system dynamics. Using this model, we design an EMPC based on an ESO that is robust to temperature changes and depends on airflow. To determine the stability of both the controller and the observer, asymptotic stability is verified through Lyapunov stability analysis. Finally, to validate the performance of the proposed controller, simulations are conducted under three scenarios with varying airflow, set temperature, and heat load.

Study on the Equilibrium Point of Heat and Mass Transfer between Liquid Desiccant and Humid Air with in the Solar Air Conditioning System

  • Sukmaji, I.C.;Rahmanto, H.;Agung, B.;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.161-167
    • /
    • 2009
  • The liquid solar air conditioning system is introduced as an alternative solution to control air condition and to save electrical energy consumption. The heat and mass transfer performances of dehumidifier/regenerator in liquid solar air conditioning system are influenced by air and desiccant condition. The application of this system, the thermal energy from the sun and inlet air are unable to control, but operation parameter of other components such as pump, fan and sensible cooling unit are able to control. The equilibrium point of heat and mass transfer are the liquid desiccant and inlet air conditions, where, the heat and mass are not transferred between the liquid desiccant and vapor air. By knowing equilibrium point of heat and mass transfer, the suitable optimal desiccant conditions for certain air condition are funded. This present experiment study is investigated the equilibrium point heat and mass transfer in various air and desiccant temperature. The benefit of equilibrium point heat and mass transfer will be helpful in choose and design proper component to optimize electrical energy consumption.

  • PDF

Experimental Study on Cooling and Heating Operation Characteristics of Inverter type Multi-Heat Pump (인버터형 멀티 히트펌프의 냉난방 운전특성에 대한 실험연구)

  • Park, B.K.;Seo, D.N.;Um, Y.S.;Kwon, Y.C.;Ko, K.W.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.618-622
    • /
    • 2007
  • In the present study, the cooling and heating operation characteristics of a multi-heat pump have been experimentally investigated for the number of the indoor units(A, B, C) and the operating conditions. The heat pump was controlled by an inverter scroll compressor. The performance of the heat pump was measured by the multi-calorimeter of an air enthalpy method. Cooling and heating capacities and COPs were obtained at the cooling and heating temperature conditions and the setting temperatures of an indoor unit. With increasing the operation frequency of the compressor, the cooling and heating capacities of the heat pump increased linearly. The operation frequency region of the compressor was different as the combination of the indoor unit and the cooling/ heating condition.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES OF A COMPOSITE RESIN INLAY BY CURING METHODS (중합방법에 따른 복합레진 인레이의 물리적 성질에 관한 연구)

  • Cho, Sung-A;Cho, Young-Gon;Moon, Joo-Hoon;Oh, Haeng-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.254-266
    • /
    • 1997
  • This study was to know the usefulness of argon laser for composite resin, to prove the polymerized effect of heat treatment of composite resin inlay and to get the curing method for optimal physical properties of composite resin inlay. In this study we used four light curing units and one heat curing unit: Visilux $II^{TM}$, a visible light gun: $SPECTRUM^{TM}$, an argon laser: Unilux AC$^{(R)}$ and Astorn XL$^{(R)}$, visible light curing unit: CRC-$100^{TM}$ for heat treatment. Compared to a control group, we divided the experemental groups into five as follows: Control group: Light curing(Visilux $II^{TM}$) Experimental group 1 : Light curing(Visilux $II^{TM}$) + Light curing(Unilux AC$^{(R)}$) Experimental group 2: Light curing(Visilux $II^{TM}$) + Light curing(Astron XL$^{(R)}$) + Heat treatment(CRC-$100^{TM}$) Experimental group 3 : Laser curing($SPECTRUM^{TM}$) Experimental group 4 : Laser curing($SPECTRUM^{TM}$) + Light curing(Unilux AC$^{(R)}$) Experimental group 5 : Laser curing($SPECTRUM^{TM}$) + Light curing(Astron XL$^{(R)}$) + Heat treatment (CRC-$100^{TM}$) According to the above classification, we made samples through the curing of Clearfil CR Inlay$^{(R)}$, which is a composite resin for inlay, in a separable cylindrical metal mold and polycarbonate plate. And then, we measured and compared the value of compressive strength, diametral tensile strength and the surface micro hardness of each sample. The results were as follows : 1. Among the experimental groups, group 5 showed the highest value of compressive strength, $157.50{\pm}10.24$ kgf and control group showed the lowest value of compressive strength, $103.93{\pm}21.93$ kgf. Control group showed significant difference with the experimental groups(p<0.001). Group 2 which was treated by the heat showed higher compressive strength than that of group 1 which was not, and there was significant difference between group 1 and group 2(p<0.001). Group 5 which was treated by heat showed higher compressive strength than group 4 which was not, and there was significant difference group 4 and group 5(p<0.001). 2. Among the experimental groups, group 5 showed the highest value of diametral tensile strength, $95.84{\pm}1.97$ kgf and control group showed the lowest value of diametral tensile strength, $81.80{\pm}2.17$ kgf. Control group which was cured by visible light showed higher diametral tensile strength than group 3 which was cured Argon Laser. Group 2 which was treated by heat showed higher compressive strength than that of group 1 which was not, and there was significant difference between group 1 and group 2(p<0.001). Group 5 which was treated by heat showed higher compressive strength than group 4 which was not, and there was a significant difference group 4 and group 5(p<0.001). 3. Among the experimental groups, group 5 showed the highest value of microhardness of top surface, $148.42{\pm}9.57$ kgf and control group showed the lowest value of microhardness, $111.43{\pm}7.63$ kgf. In the case of bottom surface, group 5 showed the highest value of $146.19{\pm}7.62$ kgf, and control group showed the lowest, $104.03{\pm}11.05$ kgf. Group 3 which was cured by Argon Laser showed higher diametral tensile strength than control group which was cured only with a visible light gun. Group 2 which was treated by heat showed higher compressive strength than that of group 1 which was not, and there was a significant difference between group 1 and group 2(p<0.001). Group 5 which was treated by heat showed higher compressive strength than group 4 which was not, and there was a significant difference group 4 and group 5(p<0.001). 4. According to the above results, we took a conclusion that argon laser can be used as a useful unit for curing the composite resin and heat treatment can improve the physical properties of the composite resin inlay.

  • PDF