• 제목/요약/키워드: Heat Transmission

검색결과 576건 처리시간 0.026초

급냉응고된 AI-Li-Cu-Mg-Zr 합금의 시효거동 (Aging Behaviors of a Rapidly Solidified Al-Li-Cu-Mg-Zr Alloy)

  • 남동회;홍영준;정해용;배차헌;김인배
    • 열처리공학회지
    • /
    • 제4권2호
    • /
    • pp.38-46
    • /
    • 1991
  • Effects of aging treatment on the microstructures and microhardness of a rapidly solidified Al-Li-Cu-Mg-Zr alloy were investigated by differential scanning calorimetry(DSC) and transmission electron microscopy(TEM). The as-melt-spun ribbon was consisted of fine ${\delta}^{\prime}$ and icosahedral intermetallic compound which were precipitated in the matrix. Two exothermic peaks with the range of $120^{\circ}C-190^{\circ}C$ and $280^{\circ}C-344^{\circ}C$ corresponded to ${\delta}^{\prime}$ and ${\theta}^{\prime}$, S', $T_1$ precipitating reaction respectively, and two endothermic peaks with the range of $190^{\circ}C-280^{\circ}C$ and $344^{\circ}C-550^{\circ}C$ corresponded to dissolution of ${\delta}^{\prime}$ and ${\theta}^{\prime}$, S', $T_1$ respectively in DSC curves. Peak hardness value was obtained at $210^{\circ}C$ for 1 hr aging treatment.

  • PDF

급냉응고된 Al-Li-Cu 합금의 시효거동 (Aging Behaviors of a Rapidly Solidified AI-Li-Cu Alloy)

  • 홍영준;김순호;강민철;김인배
    • 열처리공학회지
    • /
    • 제6권3호
    • /
    • pp.138-143
    • /
    • 1993
  • Effects of aging treatment on the microstructural evolution of a rapidly solidified Al-Li-Cu alloy were investigated by differential scanning calorimetry (DSC) and transmission electron microscopy(TEM). It was found that the precipitation sequence was: supersaturated solid solution ${\alpha}^{\prime}$ ${\rightarrow}$ metastable ${\delta}^{\prime}$ + stable precipitate $T_1$ ${\rightarrow}$ stable precipitates ${\delta}+T_1$. Two exothermic and two endothermic peaks are detected by DSC analysis. The two exothermic and endothermic peaks corresponded to ${\delta}^{\prime}$ and ${\delta}+T_1$ precipitation and dissolution reactions respectively. The enthalpy of ${\delta}^{\prime}$ precipitation decreased with increasing of aging temperature and time until the finishing point of precipitation. The activation energy for precipitation of ${\delta}^{\prime}$ was measured as 80KJ/mol and the energy for dissolution was 93KJ/mol. These values arc higher than those of AI-Li binary alloy. Peak hardness value (Hv 170) was obtamed at $210^{\circ}C$ for 1hr aging treatment which coincided with finishing point of ${\delta}^{\prime}$ precipitation.

  • PDF

Cu, Mg을 함유한 Al-Li 합금의 기계적 성질과 전기저항 변화에 미치는 기본 및 추가 강화상들의 역할 (Roles of Fundamental and Additional Hardening Precipitates on the Changes of Mechanical Properties and Electrical Resistivity in Al-Li Alloys Containing Cu and Mg)

  • 정동석;송기호;우기도
    • 열처리공학회지
    • /
    • 제7권2호
    • /
    • pp.77-87
    • /
    • 1994
  • Roles of fundamental and additional hardening precipitates on the changes of mechanical properties and electrical resistivity during precipitation decomposition in binary Al-Li, ternaty Al-Li-Cu and multi-Li-Cu-Mg-Zr alloys have been investigated by the detailed measurement of electrical resistivity, hardness and tensile strength and the observation of transmission electron micrographs. Peek hardness and tensile strength in multi-component Al-Li-Cu-Mg-Zr Alloy had higher than that of the other alloys and the results of measurement of hardness, strength and electrical resistivity in each alloys aged at 90 and $190^{\circ}C$, precipitation behaviors and mechanical properties in binary, ternary and multi-component Al-Li alloys were contributed to the ${\delta}^{\prime}$ precursory phase of ${\delta}^{\prime}$, $T_1$, G.P.B. zone and S' phases, repectively.

  • PDF

네트워크 분석법을 이용한 『온병조변』 처방의 구조적 분석 연구 (Study of structural analysis on formulas from 『Onbyungjobyun』 using network analysis)

  • 오용택;김홍준;김안나
    • 대한한의학방제학회지
    • /
    • 제27권1호
    • /
    • pp.65-71
    • /
    • 2019
  • Objective : This study aims to diversify interpretation of formulas from "Onbyungjobyun" by analyzing various formulas from "Onbyungjobyun" as basic formulas. Method : This study found herbal communities of combination by analyzing herbal combinations based on network analysis of formulas from "Onbyungjobyun", and has analyzed each community of combination as basic formulas. Result : The results of network analysis showed a total of 3 herbal communities of combination; first was medicinal herbs from Eungyo-san(銀翹散), Jeungaek-tang(增液湯), Bokmaek-tang(復脈湯), Gyeji-tang(桂枝湯), Sogeonjung-tang (小建中湯) series; second was medicinal herbs from Angungwoohwang-hwan(安宮牛黃丸); third was medicinal herbs from Baekho-tang(白虎湯), Jaseol-dan(紫雪丹), Sayeok-tang(四逆湯) series. Conclusion : The formulas from "Onbyungjobyun" are consisted of herbal communities of combination; that treat warm-heat pathogen and supplies yin essence or yang qi; treat reverse transmission to the pericardium(逆傳心包); and treat heat in the qi phase in Onbyeong and cold-dampness in the middle energizer.

금속패널지붕의 열교 방지를 위한 열교차단장치 개발 및 적용효과 분석 (Study of Thermal Bridge Breaker to Prevent the Thermal Bridge Effect on Metal Panel Roofs)

  • 김선호;정채봉;이충식;김종민;김병철
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.32-37
    • /
    • 2021
  • To realize a zero-energy building, a technology that minimizes the energy loss due to thermal bridges by preventing their formation is emerging as an important design factor. In this study, we develop a thermal bridge breaker to prevent thermal bridging in a metal panel roof and attempt to analyze the effects of its application. To this end, we fabricated a thermal bridge breaker and analyzed it in terms of its strength and heat-transfer characteristics, in addition to conducting a load simulation. The thermal bridge prevention effect of the developed thermal bridge breaker improved the insulation performance of the metal panel roof, and the results of a cooling/heating peak load simulation performed by applying the heat transmission resistance test results to a building proved the existence of this effect.

덴드리머와 팔라듐 나노입자를 이용한 단일벽 탄소나노튜브 고성능수소센서 (Effects of Pd Nanoparticles on Single-Walled Carbon Nanotubes as High-Sensitivity Hydrogen Gas Sensors)

  • 이준민;주성화;조진현;김성진;이우영
    • 대한금속재료학회지
    • /
    • 제48권4호
    • /
    • pp.342-346
    • /
    • 2010
  • Pd nanoparticles (NPs) were successfully functionalizedon the surfaces of single-walled carbon nanotubes (SWNTs) by dendrimer-mediated synthesis. The hydrogen sensing properties of the Pd NPs functionalized SWNTs were investigated. Pd NPs-dendrimer-SWNTs sensors show much better speedsand superior recovery rates but lower sensitivity compared to Pd NPs-functionalized SWNTs directly fabricated due to the existence of dendrimers. Pyrolysis of the dendrimers by heat treatment resulted in a fast response time and high sensitivity owing to the reduced length of the dendrimers. These results demonstrate that the heat treatment of dendrimers in Pd NPs-dendrimer-SWNTs sensors can enable significant electrical conductance modulation upon exposure to extremely low concentrations (10 ppm) of hydrogen gas ($H_2$) in air.

Nb 첨가 오스테나이트계 내열 스테인리스강의 열기계적 피로 수명 및 변형 거동 (Endurance Life and Deformation Behavior under Thermo-mechanical Fatigue of Nb-added Heat Resistant Austenitic Stainless Steel)

  • 오용준;박중철;양원존
    • 대한금속재료학회지
    • /
    • 제49권7호
    • /
    • pp.541-548
    • /
    • 2011
  • Thermomechanical fatigue (TMF) behavior of heat resistant austenitic stainless steel was evaluated in the temperature range from 100$^{\circ}C$ to peak temperatures of 600 to 800$^{\circ}C$; The fatigue lives under TMF conditions were plotted against the plastic strain range and the dissipated energy per cycle. In the expression of the inelastic strain range versus fatigue life, the TMF data obtained at different temperature ranges were located close to a single line with a small deviation; however, when the dissipated energy per cycle, calculated from the area of the stress-strain hysteresis loops at the half of the fatigue life, was plotted against the fatigue life, the data showed greater scattering than the TMF life against the inelastic strain range. A noticeable stress relaxation in the stress-strain hysteresis curve took place at the peak temperatures higher than 700$^{\circ}C$, but all specimens in this study exhibited cyclic hardening behavior with TMF cycles. Recrystallization occurred during the TMF cycle concurrent with the formation of fine subgrains in the recrystallized region, which is considered to cause the cyclic hardening of the steel.

Analysis on Temperature Distribution and Current-Carrying Capacity of GIL Filled with Fluoronitriles-CO2 Gas Mixture

  • Chen, Geng;Tu, Youping;Wang, Cong;Cheng, Yi;Jiang, Han;Zhou, Hongyang;Jin, Hua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2402-2411
    • /
    • 2018
  • Fluoronitriles-$CO_2$ gas mixtures are promising alternatives to $SF_6$ in environmentally-friendly gas-insulated transmission lines (GILs). Insulating gas heat transfer characteristics are of major significance for the current-carrying capacity design and operational state monitoring of GILs. In this paper, a three-dimensional calculation model was established for a GIL using the thermal-fluid coupled finite element method. The calculated results showed close agreement with experimentally measured data. The temperature distribution of a GIL filled with the Fluoronitriles-$CO_2$ mixture was obtained and compared with those of GILs filled with $CO_2$ and $SF_6$. Furthermore, the effects of the mixture ratio of the component gases and the gas pressure on the temperature rise and current-carrying capacity of the GIL were analyzed. Results indicated that the heat transfer performance of the Fluoronitriles-$CO_2$ gas mixture was better than that of $CO_2$ but worse than that of $SF_6$. When compared with $SF_6$, use of the Fluoronitriles-$CO_2$ gas mixture caused a reduction in the GIL's current-carrying capacity. In addition, increasing the Fluoronitriles gas component ratio or increasing the pressure of the insulating gas mixture could improve the heat dissipation and current-carrying capacity of the GIL. These research results can be used to design environmentally-friendly GILs containing Fluoronitriles-$CO_2$ gas mixtures.

노후화된 대학 건물의 단열성능 향상 실험 및 경제성 평가 (An Experimental Study on the Improvement of Insulation Performance in Old University Buildings and Economic Evaluation)

  • 이정민;소원호;조경찬;최동녁;이권영
    • 한국산학기술학회논문지
    • /
    • 제21권8호
    • /
    • pp.287-297
    • /
    • 2020
  • 본 연구는 노후화된 대학 건물의 내부 단열 성능 향상에 대한 것으로, 대학교 건물 내 재실자의 생산성을 높이고 노후화된 건물의 단열효과를 높이기 위해 진행됐다. 본 논문은 한동대학교 느헤미야홀 건물 내 오피스 재실자의 단열 성능 향상에 대한 지속적인 요청에 응답하여 문제해결을 위해 진행된 연구라는 차별성을 가지고 있으며, 내부온도가 인접건물의 내부온도와 비교했을 때 낮음을 확인하여 연구 필요성에 대한 타당성을 검증하였다. 학교라는 건물의 특성을 고려해 내외부 단열 중 내부 단열을 주제로 단열재를 선택했다. 대학교 교수 오피스를 소형화시킨 모형 방을 만들어 시장에서 사용되는 내부 벽면 단열재를 설치해 실험을 진행했다. 실험 결과를 바탕으로 가열 시간과 실제 열전달 계수를 측정하여 단열효과를 분석하는 경제성 평가를 실시했다. 경제성 평가는 실험과 이론에 의해, 겨울철과 여름철 기준으로 각각 실시되었다. 연구결과, 느헤미야홀 60 개의 오피스에 아이소핑크(30 T)를 내 단열재로 도입하였을 때, 한 달에 겨울철에는 최대 총 1,071,600 원을 절약 할 수 있으며, 여름철에는 총 109,200 원을 절약할 수 있다.

투자회수기간을 고려한 군 주거시설의 단열수준 산정 연구 (Insulation Level Assessment on the Military Residential Facilities Considering the Investment Payback Period)

  • 박영준;맹준호;김태희;김성중;이승민;손기영
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.57-62
    • /
    • 2015
  • Purpose: This study, which is based on the investment payback periods, aims to suggest the proper insulation level which can be adapted to the Defense Military Facility Criteria regarding the military residential condominiums. For the energy performance simulation, it is required to collect the residential data regarding the military condominiums and climatic data concerning the regions they belongs to. The estimates through energy performance simulation are the regional heating loads and the heating transmission coefficients of building components. Method: With the heating loads, the annual heating cost saving per square meters is assessed. With the heating transmission coefficients of building components, the additional insulation installment cost per square meters is evaluated. With two outcomes, one as an annual value and the other as a present value, the investment payback period is calculated. Result: In result, it could be concluded that 55~70% insulation ratio can lead a superior residental environments as well as be contributed to the national policy associated with zero-energy buildings because the estimated investment payback period is shorter than the life span of the military residental condominiums. This upshot can be used as a foundation to enactment the Defense Military Facility Criteria associated with military residential condominiums.