• 제목/요약/키워드: Heat Transfer Experiment

검색결과 742건 처리시간 0.025초

비정상후류가 선형터빈익렬의 유동 특성 및 익형의 열전달에 미치는영향에 관한 연구 (Influence of Unsteady Wake on Flow Characteristics and Heat Transfer from Linear Turbine Cascade)

  • 윤순현;심재경;이대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.393-396
    • /
    • 1998
  • To examine the influence of unsteady wake on the flow and heat transfer characteristics, an experiment has been conducted in a four-vane linear cascade. Flow and heat transfer measurements are made for the inlet Reynolds number of 66000(based on chord length and free-stream velocity). Turbulent intensity and stress were measured using hot wire anemometer, and to measure the convective heat transfer coefficients on the blade surfaces liquid crystal/gold film Intrex technique was used. The disturbance by the unsteady wake is characterized by the unresolved unsteadiness. The unsteady wake enhances the turbulent motion of flow in the cascade passage. It also promotes the boundary layer development and transition. The results show that heat transfer coefficients on the suction surface increase with increasing unresolved unsteadiness.

  • PDF

PF 열교환기를 적용한 공조기의 성능 비교 실험연구 (Experimental Study on Performance Comparison of Air-Conditioner with PF Heat Exchanger)

  • 권영철;박윤창
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.470-475
    • /
    • 2009
  • 본 연구에서는 핀-관 열교환기와 PF 열교환기의 열전달 특성과 이를 적용한 공조기의 성능을 비교 조사하였다. 또한 공조기의 냉방기간 에너지효율(CSPF)을 평가하였다. 열교환기 실험을 위해 3종류의 열교환기에 대한 열전달 및 압력강하를 그리고 공조기 성능평가를 위해 냉방표준, 냉방저온에서 냉방능력, 소비전력, COP를 산출하였다. 실험은 칼로리미터와 항온수조를 사용하여 수행되었다. 유입공기 속도가 증가함에 따라 열교환기의 열전달율과 압력강하는 증가하였다. PF 열교환기 적용 시스템의 적정 냉매량은 핀-관공조기보다 약 $15{\sim}20%$ 감소하였으나, 냉방능력은 증가, 소비전력은 감소하여 COP는 향상되었다. 사각형 핀을 가진 PF 열교환기가 삼각형 핀보다 냉방능력과 COP가 더 우수하였다. 실환경 온도조건을 반영하기 위해 PF 열교환기와 핀-관 열교환기 적용 시스템의 CSPF가 계산되었다.

R141b를 이용한 루프 세관형 히트파이프의 열전달특성 (Heat Transfer Characteristics of Loop Type Capillary Heat Pipe using R141b as a Working Fluid)

  • 김훈;하승만;김탁용;전경환;최재혁;윤석훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.256-257
    • /
    • 2005
  • This paper has been carried out to investigate heat transfer characteristics of loop type capillary heat pipe using R141b as a working fluid. In an experiment heat load are changed from 50W to 250W and the temperature of cooling water is fixed to 20$^{circ}C$ . The heat pipe is composed of 10 turns and outer diameter of heat pipe is 3.2mm. The results show that heat transport rate of this type heat pipe using R141b as a working fluid is good.

  • PDF

The Model and Experiment for Heat Transfer Characteristics of Nanoporous Silica Aerogel

  • Mingliang, Zheng
    • 한국재료학회지
    • /
    • 제30권4호
    • /
    • pp.155-159
    • /
    • 2020
  • Nanoporous silica aerogel insulation material is both lightweight and efficient; it has important value in the fields of aerospace, petrochemicals, electric metallurgy, shipbuilding, precision instruments, and so on. A theoretical calculation model and experimental measurement of equivalent thermal conductivity for nanoporous silica aerogel insulation material are introduced in this paper. The heat transfer characteristics and thermal insulation principle of aerogel nano are analyzed. The methods of SiO2 aerogel production are compared. The pressure range of SiO2 aerogel is 1Pa-atmospheric pressure; the temperature range is room temperature-900K. The pore diameter range of particle SiO2 aerogel is about 5 to 100 nm, and the average pore diameter range of about 20 ~ 40 nm. These results show that experimental measurements are in good agreement with theoretical calculation values. For nanoporous silica aerogel insulation material, the heat transfer calculation method suitable for nanotechnology can precisely calculate the equivalent thermal conductivity of aerogel nano insulation materials. The network structure is the reason why the thermal conductivity of the aerogel is very low. Heat transfer of materials is mainly realized by convection, radiation, and heat transfer. Therefore, the thermal conductivity of the heat transfer path in aerogel can be reduced by nanotechnology.

냉매의 소결금속관 표면에서의 비등 열전달에 관한 실험적 연구 (Experimental Study on Boiling Heat Transfer of the Tubes with Sintered Metal Surface for Freon-11)

  • 박찬준;문병수;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제10권3호
    • /
    • pp.220-227
    • /
    • 1981
  • The purpose of this paper is to investigate the potential ability of sintered metal tube to promote heat transfer. In the experiment for Freon - 11, the boiling heat transfer on the sintered metal tube of bronze element is investigated and compared with that of the bronze tube (bare tube) atmospheric pressure. The experimental results are obtained as follows : 1) For sintered metal tubes of bronze element with particle diameters which ranges from $79({\mu})\;to\;461({\mu})$ and bare tube, boiling characteristic curves are expressed as : a) Sintered metal tube $$q{\propto}{\Delta}T^{1.05\~1.373}$$ b) Brae tube $$q{\propto}{\Delta}T^{3.096}$$ 2) Compared with that of the bare tube at low temperature difference$({\Delta}T_{sat})$, boiling heat transfer coefficient of the sintered bronze tube are relatively high. 3) There is tendency that curves of boiling heat transfer coefficients of sintered ·bronze tube and bare tube approach each other at rather high temperature difference. It is due to the increasing rate of the former heat transfer coefficient along with temperature difference is smaller than that of the latter. 4) Referring to particle diameter, optimum condition, i. e. , maximum heat transfer coefficient is found to be at approximately 2 mm thickness of sintered layer with $D_p=150({\mu})$.

  • PDF

공기조화용 액적방열기의 열전달특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Liquid Droplet Radiator for Air Conditioning)

  • 김금무;김춘식;김용모;김종헌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.17-26
    • /
    • 1995
  • In general existing air conditioning devices, which are carried out by convection heat transfer, are very popular compared with the radiation type air conditioning devices. But perconal convection tpe air conditioning units are unuseful air conditioning type because it handles amount of surrounded air to meet the temperature and humidity. In this view, this study is intended to develope personal dir conditioning units using a radiation type radiator. Liquid Droplet Radiator(L.P.R.) radiates the energy by means of thermal radiation. Radiative energy from L.P.R. is the infrared rays which heat the objects without lose of energy. It is a desirable heating method for the local area within the large room. In this study, the analysis uses the Monte Carlo methd to predict the temperature distribution in the droplet sheet and the net heat flux from the L.D.R.. And for this study and experiment was carried out to analyse the radiative and convective heat transfer characteristics in the L.D.R.. And the experiment was investigated the effects of inlet temperature, feed rate, optical thickness and droplet diameter on heat transfer characteristics of L.D.R.. The obtained results from the numerical and experimental studies of L.D.R. were as follows ; (1) The heat flux of L.D.R. was effected by extinction coefficient of droplet sheet, optical thickness and droplet temperature, surface area and emissivity of the droplet. And it was increased with the temperature, feed rate and optical thickness, on the other hand decreased with increasing of droplet diameter. (2) The experimental results for heat flux was ecalucted below 20% than that of the numerical solution by Monte Carlo method, but the tendency of the variation shows relatively good agreement.

  • PDF

판형 열교환기의 탈설계 성능해석 및 실험 (Off-Design Performance of a Plate Heat Exchanger : Analysis and Experiment)

  • 한동원;신지영;손영석;송치성
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.779-787
    • /
    • 2004
  • Design and off-design program is set up to analyze the performance of a plate heat exchanger. The program is verified by comparing the results with the experiment. The comparison shows that the predicted overall heat transfer coefficients are in good agreement with the measurements. Also the off-design performance according to the variations of inlet water temperature, flow rate, and the number of plates is analyzed to study the performance characteristic of a plate heat exchanger.

Local Heat Transfer Coefficients for Reflux Condensation Experiment in a Vertical Tube in the Presence of Noncondensible Gas

  • Moon, Young-Min;No, Hee-Cheon;Bang, Young-Seok
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.104-104
    • /
    • 1999
  • The local heat transfer coefficient is experimentally investigated for the reflux condensation in a countercurrent flow between the steam-air mixture and the condensate. A single vertical tube has a geometry which is a length of 2.4m, inner diameter of 16.56mm and outer diameter of 19.05mm and is made of stainless steel. Air is used as a noncondensible gas. The secondary side is installed in the form of coolant block around vertical tube and the heat by primary condensation is transferred to the coolant water. The local temperatures are measured at 15 locations in the vertical direction and each location has 3 measurement points in the radial direction, which are installed at the tube center, at the outer wall and at the coolant side. In three different pressures, the 27 sets of data are obtained in the range of inlet steam flow rate 1.348 -3.282kg/hr, of inlet air mass fraction 11.8 -55.0%. The local heat transfer coefficient increases as the increase of inlet steam flow rate and decreases as the decrease of inlet air mass fraction. As an increase of the system pressure, the active condensing region is contracted and the heat transfer capability in this region is magnified. The empirical correlation is developed represented with the 165 sets of local heat transfer data. As a result, the Jacob number and film Reynolds number are dominant parameters to govern the local heat transfer coefficient. The rms error is 17. 7% between the results by the experiment and by the correlation.

  • PDF

Corrugate 휜-관 현열 열교환기의 구조에 따른 공기측 열전달 및 압력손실 특성 (Characteristic of air-side sensible heat transfer and pressure drop on the corrugate fin tube heat exchangers)

  • 류준일;전창덕;이진호;남임우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.216-221
    • /
    • 2007
  • An experiment was carried out to investigate the effect of a coolant circuit arrangement on the heat transfer and air pressure drop of a fin-tube sensible heat exchanger with the corrugated fin surface. The air inlet temperature was set to $23^{\circ}C$,the relative humidity to 50% and the air inlet flow rate to 20, 22, $25m^3/min$, respectively. while the coolant temperature was set to $7^{\circ}C$, and the coolant mass flow rate to 10, 16, 22kg/min, respectively. Experiment showed that the exchanger having a diameter of 12.7mm with parallel circuit does better performance in sensible heat transfer and air pressure drop than those three of diameter of 12.7mm with a series circuit and that with diameter of 15.88mm with a parallel circuit.

  • PDF

A Study on the Boiling Heat Transfer Characteristics Using Loop Type Thermosyphon

  • HAN, Kyu-il;CHO, Dong-Hyun
    • 수산해양기술연구
    • /
    • 제52권3호
    • /
    • pp.257-262
    • /
    • 2016
  • Flexible two-phase thermosyphons are devices that can transfer large amounts of heat flux with boiling and condensation of working fluid resulting from small temperature differences. A flexible two-phase thermosyphon consists of a evaporator, an insulation unit, and a condenser. The working fluid inside the evaporator is evaporated by heating the evaporator in the lower part of the flexible two-phase thermosyphon and the evaporated steam rises to the condenser in the upper part to transfer heat in response to the cooling fluid outside the tube. The resultant condensed working fluid flows downward along the inside surface of the tube due to gravity. These processes form a cycle. Using R134a refrigerant as the working fluid of a loop type flexible two-phase thermosyphon heat exchanger, an experiment was conducted to analyse changes in boiling heat transfer performances according to differences in the temperature of the oil for heating of the evaporator, the temperature variations of the refrigerant, and the mass flows. According to the results of the present study, the circulation rate of the refrigerant increased and the pressure in the evaporator also increased proportionally as the temperature of the oil in the evaporator increased. In addition, the heat transfer rate of the boiler increased as the temperature of the oil in the evaporator increased.