Simulation of Dynamic Characteristics of a Trigenerative Climate Control System Based On Peltier Thermoelectric Modules

  • Vasilyev, G.S.;Kuzichkin, O.R.;Surzhik, D.I.
    • International Journal of Computer Science & Network Security
    • /
    • 제21권6호
    • /
    • pp.252-257
    • /
    • 2021
  • The application of the principle of trigeneration allows to simultaneously provide electricity to power electronic devices, as well as heat and cold to create the necessary microclimate of the premises and increase efficiency compared to separate cooling and heating systems. The use of Peltier thermoelectric modules (TEM) as part of trigenerative systems allows for smooth and precise control of the temperature regime, high manufacturability and reliability due to the absence of moving parts, resistance to shock and vibration, and small weight and size parameters of the system. One of the promising areas of improvement of trigenerative systems is their modeling and optimization based on the automatic control theory. A block diagram and functional model of an energy-saving trigenerative climate control system based on Peltier modules are developed, and the transfer functions of an open and closed system are obtained. The simulation of the transient characteristics of the system with varying parameters of the components is performed. The directions for improving the quality of transients in the climate control system are determined, as well as the prospects of the proposed methodology for modeling and analyzing control systems operating in substantially nonlinear modes.

10 kW 급 암모니아-수소 혼소엔진을 위한 암모니아 개질 촉매 및 반응기 설계에 관한 연구 (A Study on Ammonia Reforming Catalyst and Reactor Design for 10 kW Class Ammonia-Hydrogen Dual-Fuel Engine)

  • 이상호;최영;박철웅;김홍석;이영덕;김영상
    • 한국수소및신에너지학회논문집
    • /
    • 제31권4호
    • /
    • pp.372-379
    • /
    • 2020
  • Ammonia-hydrogen dual-fuel engine is a way to reduce greenhouse gas emission because ammonia and hydrogen are carbon-free fuels. In ammonia-hydrogen dual-fuel engine, hydrogen is supplied to improve the combustion characteristic of ammonia. In this study, an ammonia reformer was developed to supply hydrogen for 10 kW class ammonia-hydrogen dual-fuel engine. Thermodynamic characteristic and catalyst were investigated for ammonia reforming. Heat transfer was important for high ammonia conversion of ammonia reformer. 99% of ammonia conversion was obtained when 10 LPM of ammonia and 610℃ of hot gas were supplied to the ammonia reformer.

용융성 다이아프램을 이용한 하이브리드 로켓의 연소 특성 연구 (A Study on Combustion Characteristics in Hybrid Rocket using Liquefying Diaphragm)

  • 김학철;김수종;전두성;우경진;이정표;문희장;성홍계;김진곤
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.474-478
    • /
    • 2010
  • 순수 파라핀에 10 wt%의 LDPE를 첨가한 용융성 혼합 연료로 제작한 다이아프램을 장착한 연료를 사용하여 하이브리드 로켓 연소 실험을 수행하였고 다이아프램이 없는 파라핀 연료의 결과와 비교하였다. 용융성 다이아프램을 설치한 경우 강화된 난류와 열전달로 인해 다이어프램 후방의 연료 후퇴율이 크게 증가하였으며 특성속도와 비추력이 증가하였다. 연소 불안정 해석에서는 심각한 연소 불안정이 관찰되지 않았다. 이를 통해 용융성 다이어프램이 용융성 연료를 사용하는 하이브리드 로켓의 낮은 연소 효율 개선에 효과적임을 확인하였다.

  • PDF

미세채널 워터블록의 유입부 형상에 따른 유량분배 및 열유동 특성 (Flow Distribution and Heat Transfer Characteristic of the Microchannel Waterblock with Different Shape of Inlet)

  • 최미진;권오경;윤재호
    • 설비공학논문집
    • /
    • 제21권7호
    • /
    • pp.386-393
    • /
    • 2009
  • The present study has been studied on a thermal and flow characteristic of the microchannel waterblock with flow distributions in each channels. Results of a numerical analysis using the CFX-11 are compared with results of an experiment. Numerical analysis and experiment are conducted under an input power of 150 W, inlet temperature of $20^{\circ}C$ and mass flow rates of $0.7{\sim}2.0$ kg/min. Base temperature and pressure drop are investigated with standard deviations of mass flow rates in each channels of samples. The flow distribution and j/f factor of the sample 4 is increased by about 65.7% and 42.6%, compared to that of the reference model sample 3.

국내 4개 중유발전소 실증실험을 통한 발전연료 대체용 바이오중유의 연소특성 연구 (The Four Power Plants Field Demonstration Research on Combustion Characteristic of the Bio Oil for Fuel Switching)

  • 백세현;김현희;박호영;김영주;김태형;고성호
    • 한국연소학회지
    • /
    • 제20권1호
    • /
    • pp.15-23
    • /
    • 2015
  • This paper presents the results of field demonstration for fuel switching to bio-fuel oil in 4 commercial heavy oil fired power plants. The 100% fuel switching field demonstration was successfully carried out in two tangential-firing boilers at a capacity of 75 and 100 MWe respectively without major equipment retrofit, and also 25% bio-fuel oil blending for two opposite firing boilers at a capacity of 350 and 400 MWe respectively. Despite the low density and heating value, the bio fuel was successfully replaced heavy fuel oil at the full load by only adjusting operational parameters. Incase of bio fuel oil combustion, heat absorption of radiative heat transfer section was reduced while convection section has opposite trend. In pollutants emission, a major reductionin SOx as well as 10-20% reduction in NOx were achieved by the fuels witching. On the other hand, boiler efficiency was slightly underestimated.

Characteristic analysis and condenser design of gas helium circulation system for zero-boil-off storage tank

  • Jangdon Kim;Youngjun Choi;Keuntae Lee;Jiho Park;Dongmin Kim;Seokho Kim
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권4호
    • /
    • pp.65-69
    • /
    • 2023
  • Hydrogen is an eco-friendly energy source and is being actively researched in various fields around the world, including mobility and aerospace. In order to effectively utilize hydrogen energy, it should be used in a liquid state with high energy storage density, but when hydrogen is stored in a liquid state, BOG (boil-off gas) is generated due to the temperature difference with the atmosphere. This should be re-condensed when considering storage efficiency and economy. In particular, large-capacity liquid hydrogen storage tank is required a gaseous helium circulation cooling system that cools by circulating cryogenic refrigerant due to the increase in heat intrusion from external air as the heat transfer area increases and the wide distribution of the gas layer inside the tank. In order to effectively apply the system, thermo-hydraulic analysis through process analysis is required. In this study, the condenser design and system characteristics of a gaseous helium circulation cooling system for BOG recondensation of a liquefied hydrogen storage tank were compared.

온침 시술 시 생체 조직 내 열분포 분석에 관한 연구 (Thermal Distribution in Living Tissue during Warm Needling Therapy)

  • 김종연;이종수
    • 한방재활의학과학회지
    • /
    • 제24권3호
    • /
    • pp.111-119
    • /
    • 2014
  • Objectives This study aims to analyze a thermal distribution in biological living tissue during warm needling therapy by using a finite element method. The analysis provides an understanding of warm needling's efficacy and safety. Methods A model which consisted of four-layered tissue and stainless steel needle was adopted to analyze the thermal distribution in living tissue with a bioheat transfer analysis. The governing equation for the analysis was a Pennes' bioheat equation. A heat source characteristic of warm needling therapy was obtained by previous experimental measurements. The first analysis of the time-dependent temperature distribution was conducted through points on a boundary between the needle and the tissue. The second analysis was conducted to visualize the horizontal temperature distribution. Results When heat source's peak temperatures was above $500^{\circ}C$ and temperature rising rates were relatively slow, the peak temperature at skin surface exceeded a threshold of pain and tissue damage ($45^{\circ}C$), whereas when the peak temperature was around $400^{\circ}C$, the peak temperature at the skin surface was within a safe limit. In addition, the conduction of combustion energy from the moxa was limited to the skin layer around the needle. Conclusions The results suggest that the skin layer around the needle can be heated effectively by warm needling therapy, but it appears to have little effect at the deeper tissue. These findings enhance our understanding of the efficacy and the safety of the warm needling therapy.

냉수파이프에 의한 온실의 제습 및 증발냉각효율 (Dehumidification and Evaporative Cooling Efficiency by Water Pipes in Greenhouse)

  • 김문기;남상운;윤남규
    • 생물환경조절학회지
    • /
    • 제7권3호
    • /
    • pp.237-245
    • /
    • 1998
  • 극심한 고온으로 인해 정상적인 작물의 재배가 어려운 여름철의 온실 내 기온을 억제시키기 위한 방법 중 가장 효율을 인정받고 있는 증발냉각법은 실내 습도의 증가로 인해 그 사용에 제한을 받게 된다. 본 연구에서는 온실에서 증발냉각법의 냉방효율을 높이기 위한 방법으로 냉수파이프를 설치하여, 그 열적 특성을 분석하고, 제습효과를 조사하였으며, 그 결과를 요약하면 다음과 같다. 동파이프와 아연도금스틸파이프의 총열전달량을 비교한 결과, 동파이프가 다소 크게 나타났으나, 유의성이 없었으며, 두 가지 파이프 모두 이론값 보다 실측값이 더 작게 나타났다. 냉수파이프 표면에 응축되어 제거된 수증기의 양은 동파이프와 아연도금스틸파이프 사이에서 큰 차이를 보이지 않았으나, 두 가지 파이프 모두에서 제습효과는 충분히 큰 것으로 나타났다. 냉수파이프를 설치함으로써 증발냉각시스템의 냉방효율을 평균 48%만큼 높일수 있으며, 평균 1.3$^{\circ}C$만큼의 실내기온을 추가로 냉각시킬 수 있는 것으로 예측되었다. 또한, 냉수파이프를 이용해 증발냉각시스템의 가동으로 인한 실내의 과습문제를 해결하기 위해서는 파이프표면의 응축된 수분을 효과적으로 제거할 수 있는 장치나 방법에 대한 추가적인 연구가 필요할 것으로 판단된다.

  • PDF

회전을 고려한 브레이크 디스크의 마찰열전달 연구 (Study for Characteristic of Frictional Heat Transfer in Rotating Brake System)

  • 남지우;유홍선;조성욱
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.817-822
    • /
    • 2017
  • 제동 장치는 기계장치의 사용자나 시스템의 안전관점에서 가장 중요한 요소 중 하나이며, 작동 조건 내에서 신뢰성 있는 제동력이 유지 되어야 한다. 일반적으로 브레이크는 운동에너지를 마찰을 통해 열에너지로 변환하여 회전하는 기계장치를 제동한다. 운동에너지가 열에너지로 전환되는 과정에서 고온의 열이 발생하여 기계적 거동에 영향을 준다. 마찰열은 브레이크 시스템의 열팽창 및 마찰계수 변화 등에 영향을 주고 제어되지 않는 고온은 브레이크 성능을 저하시킨다. 따라서 브레이크의 발열을 예측하고 이를 제어하는 것은 중요하다. 마찰열을 예측하기 위한 다양한 수치해석 연구들이 수행되었지만, 계산의 효율 및 재원의 한계로 수치해석의 경계조건을 다양한 형태로 가정하여 마찰열 예측 연구를 수행하였다. 가정된 마찰열 거동은 실제 열전달 온도 분포 경황과 차이가 있고 이를 이용한 냉각 효과나 열응력 수치해석 결과의 신뢰성이 부족하다. 이러한 한계점을 극복하고 마찰열 예측 시뮬레이션 절차를 정립하기 위하여 본 연구에서는 열-구조 결합 요소를 사용하여 브레이크 시스템의 마찰열 발생을 직접적으로 모사하는 시뮬레이션을 수행하였다. 본 논문은 Finite Element Method(FEM)을 이용하여 브레이크 작동에 따른 마찰열 발생을 모사하고 열분포 특성을 분석하기 위해 브레이크 모델을 대상으로 열-구조 연성요소를 적용한 수치해석 연구를 수행하였다. 이 연구는 마찰열 직접 모사의 필요성을 제안하고 시뮬레이션에 필요한 정보를 제공할 수 있다 판단된다.

Array of Slot-Sleeve Antennas for Hyperthermia Therapy

  • Park Soo-Man;Lim Yeongseog
    • Journal of electromagnetic engineering and science
    • /
    • 제5권3호
    • /
    • pp.126-131
    • /
    • 2005
  • To increase the efficiency of an applicator during microwave hyperthermia therapy, first, the length from the antenna end to a slot is varied to get the optimal matching of the characteristic impedance at the frequency of 2.45 GHz. Using the electric and thermal constants of biological tissue, we compose a phantom to calculate temperature increment as well as the resonance characteristics and the SAR distributions. The proposed 3-slot sleeve antenna inserted in an applicator plays an effective role in increasing the therapy size in the view of heating performance as electromagnetic energy tends to concentrate on not feed point direction but treatment area. The SAR is then used in combination with a finite difference heat transfer equation to determine the temperature distribution. Also, in order to shorten treatment time and increase therapy size, a square-array structure is suggested and analyzed.