창호의 성능인증 규격 기준과 면적 변화에 따른 에너지성능 비교분석 (A Comparative Analysys of Window Energy Performance According to the Difference Between Actual size and Standard size)

  • 김성범;이수열;김동윤;최원기
    • 한국태양에너지학회 논문집
    • /
    • 제40권1호
    • /
    • pp.49-60
    • /
    • 2020
  • This study reviewed selected specific windows and reviewed the window performance certification criteria including KS F 2278 and KS L 9107 and analyzed the change in performance based on the change of area. This study also compared the heating and cooling loads of an apartment house applied with window performance reviewed in consideration of insulation and SHGC performance and actual size based on KS F 2278. The analyzed window was a double window composed of aluminum and PVC and the building was the apartment house model of 141 ㎡. The analysis results were as follows. First, as the window glass's thermal performance is superior to frame, the performance degraded in reduced area. In case of selected window, the 1 m × 1m window's thermal performance and SHGC decreased by 35% and 37% respectively compared to 2 m × 2 m window. Secondly, in the comparison of performance for increasing area with 2 m × 2 m and 3 m × 3 m windows, the 3 m × 3 m window's thermal performance and SHCG increased about 14%. Third, in the comparison of heating and cooling loads of the analyzed model considering the apartment house model applied with window performance derived from KS F 2278 and actual figures, the model's total heating and cooling loads increased by 33% with cooling decreasing by 36% and heating increasing by 77%. Above analysis results show that evaluation of window performance based on criteria such as KS F 2278 and KS L 9107 may lead to distortion of performances different from actual products. Thus, it is necessary to suggest new evaluation criteria.

석면분진폭로에 의하여 석면폐증과 늑막삼출액 폐암이 합병된 1예 (A case of Asbestosis, Pleural Effusion and Lung Cancer Caused by Long-Term Occupational Asbestos Exposure)

  • 정장영;안형숙;김지원;김경아;윤임중;김한욱;최영미;송정섭
    • Tuberculosis and Respiratory Diseases
    • /
    • 제41권6호
    • /
    • pp.651-657
    • /
    • 1994
  • 저자들은 최근 석면분진에 11년간 폭로된 직업력이 있으며 작업중단 5년후 약3개월간의 호흡곤란을 주소로 입원하여 흉부X-선, 폐기능검사, 전산화단층촬영, 기관지경검사 및 석면소체검사, Gallium scan을 통하여 석면폐증, 늑막삼출액과 폐암으로 진단된 1예를 경험하였기에 문헌조사와 함께 이를 보고하는 바이다.

  • PDF

고로슬래그 미분말의 치환율 변화에 따른 고성능 콘크리트의 특성분석 (Properties of High Performance Concrete Corresponding to the Replacement Ratio of the Blast Furnace Slag)

  • 김성환;손호정;배장춘;한민철;백주현;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.669-672
    • /
    • 2008
  • 본 연구에서는 고로슬래그 미분말을 다량 치환하는 고성능 콘크리트의 가능성을 분석하기 위해, 고로슬래그 미분말의 치환율 변화에 따른 콘크리트의 특성을 분석하였는데, 그 결과를 요약하면 다음과 같다. 먼저, 굳지않은 콘크리트의 특성으로 유동성은 고로슬래그 미분말의 치환율이 증가함에 따라 증가하는 경향을 나타내었고, 공기량은 감소하는 경향을 나타내었으며, 응결시간은 지연되는 것으로 나타났다. 경화콘크리트의 특성으로 고로슬래그 미분말의 치환율이 50%까지 증가하는 조건에서의 압축강도는 초기재령에서 OPC보다 저하 하였지만 재령 28일에서는 OPC와 동등이상의 수준을 나타내었으며, 간이 단열에 의한 온도 상승량은 수화 초기에 치환율이 증가 할수록 감소였으나 후반부에서는 수화가 서서히 진행되어 수화열이 증가하는 것으로 나타났다.

  • PDF

2 모듈 스택을 이용한 5kW급 SOFC 시스템 운전결과 (Operation Results of a 5kW-Class SOFC System Composed of 2 Sub-Module Stacks)

  • 이태희;최미화;유영성
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.609-615
    • /
    • 2011
  • A 5 kW class SOFC system for cogeneration power units was consisted of a hot box part and cold BOPs. High temperature components such as a stack, a fuel reformer, a catalytic combustor, and heat exchanges are arranged in the bot box considering their operating temperatures for the system efficiency. The hot box was made of ceramic boards for the thermal insulation. A 5 kW class SOFC stack was composed of 2 sub-modules and each module had 64 cells with $15{\times}15cm^2$ area and stainless steel interconnects. The 5 kW class SOFC system was operated with a hydrogen and a city gas. With a hydrogen, the total power of the stacks was about 7.1 kWDC and electrical efficiency was about 49.3% at 80 A. With a city gas, the total power of the stacks was about 5.7 $kW_{DC}$ and electrical efficiency was about 38.8% at 60 A. Under self-sustained operating condition, the system efficiency including a power conditioning loss and a consumed power by BOPs was about 30.2%.

단열갱폼 적용에 따른 동절기 보양비 사용량 및 발열량 검토에 관한 실험적 연구 (A Study on the Energy Consumption Cost in the Winter and Calorific Value by Insulated Gang-form)

  • 남경용;최석;안성진;임명관
    • 한국건축시공학회지
    • /
    • 제20권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 본 논문은 동절기 콘크리트 보양 시 투입되는 에너지(전력) 소비량과 콘크리트 발열량 변화를 통해 단열갱폼의 단열성능을 검토하고자 하였다. 실험결과에 따르면, 일반갱폼은 콘크리트 타설 이후 12시간동안 에너지(전력) 소비가 3회 발생하게 된다. 반면 단열갱폼은 콘크리트 타설 후 21시간 동안 에너지(전력) 소비가 발생되지 않았다. 최종 전력 소비량은 일반갱폼이 단열갱폼보다 3.7배 높게 나타나 에너지(전력) 소비에서 단열갱폼의 우수한 성능을 확인할 수 있었다. 발열량 검토결과는 일반갱폼에서 콘크리트 타설 후 외기 온도변화에 따라 발열량이 크게 변하는 것을 알 수 있었다. 하지만 단열갱폼의 경우 프레임 일부에서 미비한 열손실이 발생했을 뿐 콘크리트 타설 직후부터 거푸집 탈형까지 일정한 발열패턴을 보여주고 있었다.

환경온도 -10℃에서 Clo값에 따른 인체 생리반응 및 주관적 감각 (Physiological Responses and Subjective Sensations by Clo Values at -10℃)

  • 김지연;송민규;김희은
    • 한국의류산업학회지
    • /
    • 제12권4호
    • /
    • pp.531-537
    • /
    • 2010
  • The purpose of this study was to review physiological responses and subjective sensations in the cold environment when the subjects wore ensemble with different clo values. Seven healthy male subjects participated in this experiment. This experiment was conducted in a climatic chamber with $-10^sC$ and 50%RH. Subjects wore five different kinds of ensemble[C1 (4.453 clo), C2 (3.452 clo), C3 (2.865 clo), C4 (2.387 clo), and C5 (2.280 clo)]. The experiment was composed of 20 min of rest period, 20min of treadmill exercise(6 km/h) period, 30 min of recovery period. We monitored skin temperature on 7 sites, clothing microclimate and subjective sensations. The clo value had positive correlations with mean skin temperature and clothing microclimate. The subjects feel more warm and humid as the clo value goes up. The subjects reported comfort when they wore C1 and C2 ensemble having over 3 clo value. However, they felt less comfortable during the exercise period since there was high humidity. Skin temperature on the extremities were more dramatically changed by the exercise rather than clo value. Thus it seems that in the cold environment, heat balance can mostly be controlled by the choice of clothing, and the clothes with high clo values can provide higher insulation. In conclusion, our findings suggest that it would be more effective to control clo value depending on the activity level for maintaining comfort level in the cold environment.

변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구 (Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer)

  • 김국겸;서용권;강상모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.449-455
    • /
    • 2015
  • 전력용 변압기 용량의 증대와 고효율화에 따른 권선의 단위체적당 열발생량의 증가 및 이에 따른 절연성능의 저하는 전력용 변압기의 수명과 신뢰성에 큰 영향을 준다. 이러한 문제점은 방열기의 냉각성능을 증가시킴으로써 해결이 가능하다. 본 연구는 ONAF(Oil Natural Air Forced) 형식의 변압기의 방열기에 대해 공기의 강제대류를 일으키는 팬의 위치에 따른 냉각성능 평가를 통하여 냉각효과가 가장 큰 팬의 위치를 찾기 위한 것이다. 해석에는 유동해석 상용소프트웨어를 사용하였으며, 해석시간의 단축을 위하여 오일의 냉각유로를 단순화시켰고 팬의 지름을 일정하게 두고 팬의 위치를 다양하게 변화시켜가며 해석을 실행하였다. 해석 결과 팬의 수직적인 위치 변화는 냉각성능에 크게 영향을 주지 않았으나 팬이 변압기의 전방영역에 위치할 경우 후방영역의 배치보다 온도강하가 큰 것을 확인할 수 있었다.

표면개량 버블시트 종류 변화가 서중환경 콘크리트의 온도 및 균열발생에 미치는 영향 (Effect of the Kind of Modified Bubble Sheets on the Temperature Profiles and Crack Reduction of the Concrete under Hot Weather)

  • 이상운;한민철
    • 한국건축시공학회지
    • /
    • 제18권3호
    • /
    • pp.251-257
    • /
    • 2018
  • 여름철 콘크리트는 수분증발에 의한 소성 및 건조수축균열, 슬럼프 저하, 콜드조인트 발생 등 다양한 문제가 발생한다. 이에 국내에서는 수분증발을 방지하고, 단열성능을 확보하기 위해 표면피복 양생을 위한 다양한 형태의 버블시트를 제작하여 사용하고 있으나, 여름철에는 적용사례가 없었다. 따라서 본 연구에서는 여름철 시공중인 아파트 현장에 1중의 투명, 백색 및 알루미늄 증착 버블시트와 PE필름 및 표면노출의 5가지 표면피복 양생재를 적용하여 콘크리트의 온도 및 균열특성 등 품질에 미치는 영향을 분석하였다. 실험결과 알루미늄 증착 버블시트가 온도저감, 균열저감 면에서 가장 뛰어난 것으로 나타났지만, 알루미늄 재질의 특성상 빛이 반사되어 시공자의 눈부심에 따른 시각공해가 발생하기 때문에 백색 버블시트의 사용이 가장 효과적인 것으로 밝혀졌다.

메가스포츠시설의 사후 활용을 위한 임시주거 계획 - 2018평창동계올림픽을 중심으로 - (The Planning of Temporary Housing for Post Application of Mega Sports Facilities - Focused on the 2018 Winter Olympics -)

  • 이종찬;강윤도;김병선
    • KIEAE Journal
    • /
    • 제16권4호
    • /
    • pp.41-46
    • /
    • 2016
  • Purpose: This is a study on the planning of temporary housing for post application of Mega Sports facilities. The subject of the study is 2018 Pyeongchang Winter Olympics, which is to suggest building an alternative temporary housing using shipping containers(high cube), which solve the lack of accommodations and recycle temporary housing after Olympics, save money and be eco-friendly in Olympics. Method: This study includes this ; research on the a fact-finding survey about Mega sports facilities post application and demand survey on 2018 Pyeongchang Winter Olympics accomodations and an analysis about temporary housing plan. Furthermore we decided temporary housing building plan by analyzing residents' needs and traits of the housing etc. Through this, we made a schematic design for household units. Result: As a result, this study is a plan of making space, forms, and structure. The planned size is $38.4m^2$(L:12m, W:3.2m) except balcony, and indoor height is 2.5m. The space consists of entrance, bathroom, bedroom and living room with folding furniture system. Also there's a detailed floor plan of the ceiling, wall, and floor we drew up. The ceiling and wall consist of dampproof film, noncombustible board, fire proof urethane form, and color-designed sheet. The floor is composed of floor tile, cement mortar, light concrete(with heat coil), insulation, and dampproof film. Additionally, this study is a plan of interior dry wall with detail using modular construction method for work efficiency and quality improvement.

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.