• Title/Summary/Keyword: Heat Insulation

Search Result 887, Processing Time 0.025 seconds

A Study on the Thermal Design of the Cryogenic LNG Carrier (초저온 LNG선의 열설계에 관한 연구)

  • 김용모;고상철;천병일;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.1-10
    • /
    • 1993
  • This paper introduces the outline of hull structure to the sorts of LNG carrier briefly. Especially, explains in detail for the insulation system of Moss Rosenberg Verft spherical tank type LNG carrier. It is not easy task to calculate exactly the temperature distribution of hull because of very complicated structure of hull. Therefore, in this paper by the adequate modeling of the Moss Rosengerg spherical tank type LNG carrier, a program is developed which calculate the temperature distribution of every hull and estimate the heat influx from every hull and output the BOR according to the variation of atmospheric conditions on boyage.

  • PDF

Research and Development of RFIC Technology in Smart Temperature Information Material

  • Chang, Chih-Yuan;Hung, San-Shan;Chang, Yu-Chueh;Peng, Yu-Fang
    • Journal of Construction Engineering and Project Management
    • /
    • v.1 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • Conservation of energy and fuel is the trend in smart building design. Radio Frequency Integrated Circuit (RFIC) technology is often used in temperature sensing and signal transmission to manage indoor temperature, but it is rarely applied to the shell of the building. Heat retention and poor insulation in building shells are the largest causes of high energy consumption by indoor air conditioning. Through combining RFIC technology with temperature sensors, this study will develop smart temperature information material that can be embedded in concrete. In addition to accurately evaluating the effectiveness of shell insulation material, the already-designed Building Physiology Information System can monitor long-term temperature changes, leading to smarter building health management.

A Study on the Insulation Degradation Properties for Stator Form-wound Winding of Traction Motors in Urban Transit E.M.U (철도차량용 견인전동기의 형권 고정자 코일에 대한 절연열화 특성 연구)

  • Kim, K.J.;Chae, S.H.;Wang, J.B.;Park, H.J.;Lee, I.W.;Hur, I.G.;Ha, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.452-454
    • /
    • 1999
  • In this paper, sample coils for stator form-wound winding of traction motor were made for the accelerative thermal degradation composed of heat, vibration, moisture and overvoltage. In progress of test periods, diagnosis tests such as insulation resistance, dielectric loss and partial discharge were investigated. Reliability and expected life were evaluated on the insulation system for 200 class traction motor considering various environmental stress.

  • PDF

Condition Diagnosis by the Complex Accelerating Degradation for fault Prediction & estimation of reliability on the traction motor - Insulation Resistance & Polarization Index Properties (견인전동기의 고장예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 절연저항 및 성극지수 특성 연구)

  • Wang, Jong-Bae;Byun, Yoon-Sub;Baek, Jong-Hyen;Park, Hyun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1374-1376
    • /
    • 2000
  • In this paper, sample coils for stator form-wound winding of traction motor were tested by the accelerative thermal degradation, which composed of heat, vibration, moisture and overvoltage applying. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, insulation resistance and PI properties were investigated as diagnosis tests in the range of $20{\sim}160^{\circ}C$. Analysis of polarization properties was performed on the base of do current-time change.

  • PDF

Properties of Thermal Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 열적 열화특성)

  • Park Hyun-June;Lee Chang-Moo;Lee Han-Min;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.606-610
    • /
    • 2003
  • The 200 class insulation system which adopted to traction motor have excellent dielectric strength but weaken to thermal stress therefore deterioration phenomena analysis according to thermal stress is necessary. Accelerated thermal aging tests have been used to determine thermal reliability of stator coils used as traction motor in electric multiple unit. The conventional aging test is carried on according to IEC 60034-18-31 and IEEE Std. 275-1992. Variation in insulation resistance, P.I, capacitance, dielectric loss($tan{\delta}$) and partial discharge are measured during the aging cycle. Sample coils for traction motor were tested by accelerated aging test which composed of heat, vibration and moisture. Reliability and expected life were evaluated on the insulation system for traction motor.

  • PDF

A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window (슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF

Thermoregulation of the Aged People in Cold, with Special Reference to Physical Insulation (노인(老人)의 한냉환경(寒冷環境)에서의 체온조절상(體溫調節相)에 관(關)한 실험적연구(實驗的硏究) - 특(特)히 물리적조절상(物理的調節相)에 관(關)하여 -)

  • Lee, Dae-Yon
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.215-230
    • /
    • 1967
  • It has been suggested by Krag and Kountz (1950), Horvath et al. (1955) and Spurr et al. (1955) that the mechanism for prevention of heat loss is less efficient in the aged than in the young. In addition, they observed that peripheral vasoconstriction occurred more rapidly and more intensively in the aged people in response to the cold stimulus. Although it is not clear on the basis of these reports whether the Physical insulation of the aged people in cold would be different from the younger, it is evident that the vascular reactivity in response to cold seems to be altered in the aged people. Hence this investigation was undertaken to investigate the physical insulation of the aged people in a systemic manner by water immersion method which has been successfully applied to the Eskimos and Korean diving women by Rennie et al.

  • PDF

Development of Rice Hull Insulation Board using Urea Formaldehyde Resin (요소수지(尿素樹脂) 연질(軟質) 왕겨보드의 개발(開發))

  • Lee, Hwa-Hyoung;Kang, Chun-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.50-55
    • /
    • 1998
  • This study was carried out to develop low density board made of rice hull which needs proper use. Urea formaldehyde adhesive(UF) was used. The raw materials were the mixtures of the rice hulls from IllFum, DongGin, ChuChong, etc. The physical and mechanical properties of rice hull insulation board were examined. The results are as follows : For the thickness of 15mm of the low density rice hull board bonded with UF resin, proper manufacturing conditions were $171^{\circ}C$ of hot pressing temperature with thickness bar for optimum density, 12 percent of resin solid contents of rice hull ovendry weight, and 20 minutes of hot pressing time. These conditions meet Korean standards(KS 3201-1982) in relation to free formaldehyde emission, bending strength, water absorption and heat resistance.

  • PDF

A Study on the Chemical Compositions of Jeju Basalt for the Development of an Inorganic Insulation Material (무기 내화 단열재 개발을 위한 제주도 현무암의 화학조성에 대한 연구)

  • Gang, Myung-Bo;Kam, Sang-Kyu;Kim, Nam-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.3
    • /
    • pp.1-6
    • /
    • 2019
  • The basalt fiber, which is found to be non-toxic and harmless to the human body, is expected to become a trend for industrial fibers as they have better properties of non-combustion, heat-resistant, soundproof, absorbent, moistureproof, wear-resistant, corrosion resistant, lightweight, and high strength properties. Thus, in this study, we analyzed the chemical compositions of basalt produced at seven sites on Jeju Island for making a high value inorganic insulation material. The results showed that the MgO content of basalt collected from the eastern part of Jeju Island was higher than 7.5 percent, while that of the western region was less than 6 percent.

RESEARCH AND DEVELOPMENT OF RFIC TECHNOLOGY IN SMART TEMPERATURE INFORMATION MATERIAL

  • Chih-Yuan Chang;San-Shan Hung;Yu-Chueh Chang;Yu-Fang Peng
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.480-486
    • /
    • 2011
  • Conservation of energy and fuel is the trend in smart building design. Radio Frequency Integrated Circuit (RFIC) technology is often used in temperature sensing and signal transmission to manage indoor temperature, but it is rarely applied to the shell of the building. Heat retention and poor insulation in building shells are the largest causes of high energy consumption by indoor air conditioning. Through combining RFIC technology with temperature sensors, this study will develop smart temperature information material that can be embedded in concrete. In addition to accurately evaluating the effectiveness of shell insulation material, the already-designed Building Physiology Information System can monitor long-term temperature changes, leading to smarter building health management.

  • PDF