• Title/Summary/Keyword: Heat Cycle

Search Result 1,580, Processing Time 0.027 seconds

LCC 분석에 의한 하천수 미활용에너지 이용시스템의 경제성 평가 (Life-Cycle Analysis of the River Water Unutilized Energy System)

  • 박일환;윤형기;장기창;박준택;박성룡
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.596-604
    • /
    • 2005
  • This paper presents the work on evaluating the LCC (Life-Cycle Cost) of a heat pump system as unutilized energy system. The river water as an unutilized energy source was used for the heat source of heat pump system. LCC analysis is a concrete method for evaluating the economical efficiency of energy facilities of building. The present case study shows an example of adequate use of the LCC analysis on a heat pump system and conventional gas boiler and refrigerator for building heat supply. A life cycle of 20 years was used to calculated net present value of energy cost. Over a 20 year life cycle, the energy cost could be reduced by 612 million won if a heat pump system were used instead of a conventional boiler and an absorption refrigerator.

온라인 웹기반 원전 터빈 사이클 열성능 분석 시스템 (Web-Based On-Line Thermal Performance Analysis System for Turbine Cycle of Nuclear Power Plant)

  • 최기상;최광희;지문학;홍승열;김성근
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.409-416
    • /
    • 2005
  • We need to develop a on-line thermal performance analysis system for nuclear power plant to determine performance status and heat rate of turbine cycle. We have developed PERUPS(PERformance Upgrade System) to aid the effective performance analysis of turbine cycle. Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on PTC(Performance Test Code). Robustness in the on-line performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful web interfaces for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis report. The system was successfully applied for YongGwang nuclear plant unit #3,4.

Revised VX흡수식 냉동사이클의수치 해석 (A Numerical Analysis of a Revised VX Absorption Cooling Cycle)

  • 장원영;정은수;김병주
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.505-513
    • /
    • 2001
  • A revised VX cycle using ammonia/water as the working fluid is a cycle which is suitable to produce cooling utilizing low temperature hat sources. The cycle was analyzed numerically to investigate the effects of the design and operating conditions on the performance. It was shown that both COP and cooling capacity were significantly influenced by the performance of he rectifier. Insufficient UA of the rectifier reduced both ammonia mass fraction and mass flow rate of the vapor entering the condenser, which produced cooling effect in the evaporator. As the temperature and the mass flow rate of the heat source increased, both COP and exergetic efficiency decreased due to the irreversibilities produced in heat exchangers, but cooling capacity did not vary much. Cooling capacity increased significantly as the coolant temperature decreased, although COP and exergetic efficiency remained nearly constant.

  • PDF

저온 해수를 이용한 난방 및 담수화사이클 성능 해석 (Analysis of Heating and Desalination Cycle Using Low Temperature Seawater)

  • 이호생;이승원;정동호;문덕수;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제14권4호
    • /
    • pp.301-306
    • /
    • 2011
  • 저온 해수에너지를 이용한 난방사이클 및 이와 연계할 수 있는 적정 담수화사이클에 대하여 제안 및 해석을 수행하였다. 난방사이클은 기본 증기압축식 사이클을 이용하여 1단 및 2단압축사이클에 대해 해석을 수행하였고, 담수화사이클은 난방사이클과 연계할 수 있도록 설계하여 해석을 수행하였다. 난방사이클의 증발기 열원으로 5이하의 저온 해수열을 이용하였고, 난방수 온도는 60 이상 공급될 수 있도록 해석하였으며, 사이클 작동유체는 R-134a, R-1234 yf, R-600a를 적용하였다. 사이클 해석 결과, 2단압축사이클을 적용할 경우 1단압축사이클에 비해 모든 냉매에서 압축기 소요동력은 약 15.6% 감소하였고, 성능계수는 약 17.6% 향상되었다. 냉동법 담수화 사이클의 경우 R-134a에 대해서 난방수 60 조건일 때, 1단압축 사이클에 비해 2단압축사이클을 적용할 경우 담수 1kg 생산당 에너지가 약 19.8% 감소하는 것으로 나타났다.

복합사이클 발전플랜트 폐열회수 보일러의 구성요소 크기비의 최적화 (Ratio Optimization Between Sizes of Components of Heat Recovery Steam Generator in Combined Cycle Gas Turbine Power Plants)

  • 인종수;이상용
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.403-410
    • /
    • 2009
  • This paper proposes a new approach to find the optimum ratios between sizes of the heat exchangers of the heat recovery steam generator (HRSG) system with limited size to maximize the efficiency of the steam turbine (bottom) cycle of combined cycle power plants (CCPP), but without performing the bottom cycle analysis. This could be achieved by minimizing the unavailable exergy (the sum of the destroyed and the lost exergies) resulted from the heat transfer process of the HRSG system. The present approach is relatively simple and straightforward because the process of the trial-and-error method, typical in performing the bottom cycle analysis for the system optimization, could be avoided. To demonstrate the usefulness of the present method, a single-stage HRSG system was chosen and the optimum evaporation temperature was obtained corresponding to the condition of the maximum useful work. The results show that the optimum evaporation temperature based on the present exergy analysis appears similar to that based on the bottom cycle analysis. Also shown is the dependency of size (NTU) ratios between the heat exchangers on the inlet gas temperature, which is another important factor in determining the optimum condition once overall size of the heat recovery steam generator is given. The present approach turned out to be a useful tool for optimization of the singlestage HRSG systems and can easily be extended to multi-stage systems.

LNG 냉열을 이용하는 암모니아-물 랭킨 사이클과 유기 랭킨 사이클의 열역학적 성능 특성 해석 (Thermodynamic Performance Analysis of Ammonia-Water Rankine Cycle and Organic Rankine Cycle Using Cold Energy of LNG)

  • 김경훈
    • 한국수소및신에너지학회논문집
    • /
    • 제31권4호
    • /
    • pp.363-371
    • /
    • 2020
  • Recently, the technologies to utilize the cold energy of liquefied natural gas (LNG) have attracted significant attention. In this paper, thermodynamic performance analysis of combined cycles consisting of ammonia Rankine cycle (AWR) and organic Rankine cycle (ORC) with LNG Rankine cycle to recover low-grade heat source and the cold energy of LNG. The mathematical models are developed and the effects of the important system parameters such as turbine inlet pressure, ammonia mass fraction, working fluid on the system performance are systematically investigated. The results show that the thermal efficiency of AWR-LNG cycle is higher but the total power production of ORC-LNG cycle is higher.

해수열원 히트펌프 시스템의 냉난방 운전 특성에 관한 실증 연구 (Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump)

  • 김지영;백영진;나호상;장기창
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.544-549
    • /
    • 2009
  • The purpose of this study is to investigate the field Operation Characteristics of a sea water heat source cascade heat pump system and system applicable to Building. Cascade heat pump system is composed R410A compressor, R134a compressor, EEV, cascade heat exchanger, Plate heat exchanger etc. Building area is $890m^2$ and has five floors above ground. R410A is used for a low-stage working fluid while R134a is for a high-stage. The system could runs at dual mode. One is mode of general R410A refrigeration cycle in summer and the other is cascade cycle. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. The filed test results show that the sea water heat source heat pump system exhibits a COP of about 5.5 in cooling mode along with a heating COP of about 4.0 in 1-stage heating mode. Cascade 2-stage heat pump system is enough to supply $60^{\circ}C$ water and heating COP is about 3.0

  • PDF

이상 브레이튼 사이클에서의 램 제트 추진기관 성능의 기본 특성 (Performance Characters of the Ramjet Based on Ideal Brayton Cycle)

  • 이태호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.117-121
    • /
    • 2003
  • In order to investigate the performance characters of the ramjet propulsion, at the first step, in this paper Ideal Brayton cycle is adopted. In the Ideal Ramjet cycle some of the Parameters are independent of the heat input, for example thermal efficiency but in the Ideal Brayton cycle, Mach number and the entry temperature of the combustion chamber are important variables with the heat input.

  • PDF

저온 지열발전의 출력 극대화를 위한 흡수식 동력 사이클의 시뮬레이션 (Simulation of an Absorption Power Cycle for Maximizing the Power Output of Low-Temperature Geothermal Power Generation)

  • 백영진;김민성;장기창;이영수;윤형기
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.145-151
    • /
    • 2010
  • 본 연구에서는 지열발전 등과 같은 저온 열원을 에너지원으로 하는 발전에 응용될 수 있는 흡수식 동력 사이클의 출력 최적화를 수행하였다. 이를 위해 정상상태 사이클 시뮬레이션을 수행하여 사이클의 성능을 고찰하였다. 시뮬레이션은 열원과 열침의 입구온도 및 유량을 고정한 상태에서 수행하였으며, 일반적인 발전소의 열원-열침 유량비를 고려하였다. 사이클의 성능은 두 개의 독립변수를 이용하여 나타내었는데, 이는 분리기 입구 암모니아 농도와 터빈 입구 압력이다. 시뮬레이션 결과, $100^{\circ}C$의 지열수와 $20^{\circ}C$의 냉각수(지열수 유량의 5배) 조건에서, 흡수식 동력 사이클을 이용하면 지열수 유량 1 kg/s 당 최대 약 14 kW의 출력을 얻을 수 있음을 보였다.

바이오매스를 에너지원으로 하는 유기냉매 사이클 스크롤 팽창기 발전 장치 설계 (Design of Scroll Expander for Electric Power Generation System using Organic Rankine Cycle with Biomass Energy Source)

  • 문제현;유제승;김현진;조남진
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.30-36
    • /
    • 2012
  • A scroll expander has been designed to produce a shaft power from a R134a Rankine cycle for electricity generation. Heat was supplied to the Rankine cycle through a heat exchanger, which received heat from another cycle of water. In the water cycle, water was heated up in a boiler using biogenic solid fuel. The designed scroll expander was a horizontal type, and a trochoidal oil pump was employed for oil supply to bearings and Oldham-ring keys. For axial compliance, a back pressure chamber was created on the backside of the orbiting scroll base plate. Numerical study has been carried out to estimate the performance of the designed scroll expander. The expander was estimated to produce the shaft power of about 2.9 kW from a heat supply of 36 kW, when the temperature of R134a was $80^{\circ}C$ and $35^{\circ}C$ at the evaporator and condenser of the Rankine cycle, respectively. The expander efficiency was about 70.5%. When the amount of heat supply varied in the ranges of 7.5~55 kW, the expander efficiency changed in the range of 45.6~70.5%, showing a peak efficiency of 70.5% at the design shaft speed.