• Title/Summary/Keyword: Heat Control

Search Result 3,676, Processing Time 0.038 seconds

Heat Inducible Expression of the CDC70 Gene Under the Control of Heat Shock Element in Saccharomyces Cerevisiae

  • Lee, Seok-Jae;Jahng, Kwang-Yeop;Lee, Young-Hoon;Chae, Keon-Sang
    • Journal of Microbiology
    • /
    • v.33 no.3
    • /
    • pp.196-200
    • /
    • 1995
  • In order to express the CDC70 gene of Saccharomyces cerevisiae by heat shock, we have designed heat inducibe hybrid promoters using the Drosophila melanogaster heat shock elements (HSEs). A 220 bp-long upstream fragment of the D. melanogaster hsp70 gene comprised of four HSEs was placed upstream of the putative proximal TATA box of the CDC70 gene. Hybrid promoters containing different fusion joints were tested for their ability to drive the CDC70 gene expression by heat shock. The results showed that the HSEs of D. melanogaster conferred the heat-induced CDC70 gene expression, but the heat inducibility was much lower than that in D. melanogaster.

  • PDF

Effects of Postharvest Heat Treatment on Alleviation Chilling Injury and Improvement Storability of Oriental Melon (수확 후 고온처리가 참외의 저온장해 완화와 저장성 향상에 미치는 영향)

  • Kang Ho-Min;Park Kuen-Woo;Kim Il Sop
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.137-143
    • /
    • 2005
  • Oriental melons hold at $38^{\circ}C$ for 48 hours before storage increased their soluble solid, titratable acidity, vitamin C contents and ${\alpha}$-tocopherol activity. These heat treated oriental melons maintained lower production of carbon dioxide, ethylene and acetaldehyde and loss of fresh weight than untreated them, called control, during $3^{\circ}C$ MA storage. After 39 days in storage, the last day of storage, visual quality and internal quality, such as firmness, soluble solid, titratable acidity, vitamin C and ${\alpha}$-tocopherol activity, showed higher in heat treated oriental melons. Especially, Ion leakage of flesh, index of chilling injury, increased remarkably in control, so that heat treatment had to alleviate chilling injury in oriental melon. Moreover, while Alternaria rot was shown in control plot after 25 days in $3^{\circ}C$ MA storage, oriental melons treated heat were not appeared any decomposition after 39 days in $3^{\circ}C$ MA storage. As storage life of oriental melon was calculated by regression equation between visual quality and days in storage, that was longer 8 days in heat treated than control. Consequently, heat treatment that was mild, $38^{\circ}C$ and long period, 48 hours, executed before storage, sterilized surface alleviated chilling injury and lengthened storage life in oriental melons.

발효조의 냉각량 측정을 통한 유가배양제어

  • Hong, Geon-Pyo;Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.181-184
    • /
    • 2000
  • The cooling rate of a bioreactor was measured to estimate the heat generation by microbial cultivation production. The estimated heat production was calculated from the varying temperature of cooling water. It was used for monitoring growth and specific metabolic events for microbial cultivations. Metabolic heat measured was also adopted for a control parameter for fed-batch cultivation.

  • PDF

A precision temperature control system using one-board micom (One-board micom을 이용한 정밀 온도 제어 시스템)

  • 주해호;조덕현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.457-461
    • /
    • 1988
  • In this study an one-board micom controlled precision temperature control system has been developed. The digital temperature control system is consisted of an one-board micom as digital controller, a 12-bit A/D and D/A converter, a power amplifier, a NTC thermister, a preamplfier and a heat chamber. An operating control program for the control system was written in Z80 machine language. A Dual-PID predictor control algorithm was proposed. Experments were conducted with different sampling time and limitted error value. As a result, the temperature in a heat chamber can be well controlled within +- 0.2 .deg.C when the sampling time was applied to 10 sec and the limitted error value +- 0.5 .deg.C under the dual-PID predictor control algorithm. By means of one-board micom overall system has been reduced in size and volume, thus the system becomes compact and less expensive.

  • PDF

Implementation of Real-Time Thermal Environment for Virtual Reality Using Gain Scheduling and Cascade Control (게인 스케쥴링과 캐스케이드 제어에 의한 가상현실용 열환경의 실시간 구현)

  • Sin, Yeong-Gi;Jang, Yeong-Su;Kim, Yeong-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.7
    • /
    • pp.567-573
    • /
    • 2001
  • A real-time HVAC system is proposed which implements real-time control of thermal environment for virtual reality. It consists of a pair of hot and cold loops that serve as thermal reservoirs, and a mixing box to mix hot and cold air streams flowing if from loops. Their flow rates are controlled in real-time to meet a set temperature and flow rate. A cascade control algorithm along with gain scheduling is applied to the system and test results shows that the closed-loop response approached set values within 3 to 4 seconds.

  • PDF

Experimental Study on the Heating Performance Improvement of R134a Heat Pump System for Zero Emission Vehicles (무공해자동차용 R134a 히트펌프 시스템의 난방성능 향상에 관한 실험적 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.257-262
    • /
    • 2014
  • This paper describes an experimental study for heating performance that can be used in R-134a automobile heat pump systems. The heat pump system is widely studied for heating system in zero-emission vehicles to attain both the small power consumption and the effective heating of the cabin. This paper presents the experimental results of the influence on heating capacity and coefficient of performance of heat pump system. Tests were performed with different sizes of internal and external heat exchangers, and refrigerant flow rate was also considered in two-way flow devices. In addition, the heat, air, and water sources with the heat pump system were examined. The experimental results with the heat pump system were used to analyze the impact on performances. The best combination of performance was A-inside heat exchanger, B-outside heat exchanger, and B-flow device, respectively. In addition, a water heat-source was found to give roughly 40% of better performance than an air heat-source heat pump system.

Performance Comparison of Liquid-Cooling with Air-Cooling Heat Exchangers Designed for Telecommunication Equipment

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kang, Hoon;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • Electronic and telecommunication industries are constantly striving towards miniaturization of electronic devices. Miniaturization of chips creates extra space on PCBs that can be populated with additional components, which decreases the heat transfer surface area and generates very high heat flux. Even though an air-cooling technology for telecommunication equipment has been developed in accordance with rapid growth in electrical industry, it is confronted with the limitation of cooling capacity due to the rapid increase of heat density. In this study, liquid-cooling heat exchangers were designed and tested by varying geometry and operating conditions. In addition, air-cooling heat exchangers were tested to provide performance data for the comparison with the liquid-cooling heat exchangers. The liquid-cooling heat exchangers had twelve rectangular channels with different flow paths of 1, 2, and 12. Silicon rubber heaters were used to control the heat load to the heat exchangers. Heat input ranged from 293 to 800W, and inlet temperatures of working fluid varied from 15 to $27^{\circ}C$. The heat transfer coefficients were strongly affected by flow conditions. All liquid-cooling heat exchangers showed higher cooling performance than the air-cooling heat exchanger. The heat exchanger with 2-paths could provide more controllability on the maximum temperature than the others.

Heat Exchange Performance of Improved Heat Recovery System (개량형 열회수 시스템의 열교환 성능)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Kwon, Jin-Keun
    • Journal of Bio-Environment Control
    • /
    • v.12 no.3
    • /
    • pp.107-113
    • /
    • 2003
  • This study was carried out to improve the performance of pre-developed heat recovery devices attached to exhaust-gas flue connected to combustion chamber of greenhouse heating system. Four different units were compared in the aspect of heat recovery performance; A-, B-, and C-types are exactly the same with the old ones reported in previous studies. D-type newly developed in this experiment is mainly different with the old ones in its heat exchange area and tube thickness. But airflow direction(U-turn) and pipe arrangement are similar with previous three types. The results are summarized as follows; 1. System performances in the aspect of heat recovery efficiency were estimated as 42.2% for A-type, 40.6% for B-type, 54.4% for C-type, and 69.2% for D-type. 2. There was not significant improvement of heat recovering efficiency between two different airflow directions inside the heat exchange system. But considering current technical conditions, straight air flow pattern has more advantage than hair-pin How pattern (U-turn f1ow). 3. The main factors influencing on heat recovery efficiency were presumably verified to be the total area of heat exchange surface, the thickness of ail-flow pipes, and the convective heat transfer coefficient influenced by airflow velocity under the conditions of allowable pipe durability and safety. 4. Desirable blower capacity for each type of heat recovery units were significantly different to each other. Therefore, the optimum airflow capacity should be determined by considering in economic aspect of electricity required together with the optimum heat recovery performance of given heat recovery systems.

Microstructural Control of Al-Sn Metal Bearing Alloy with Heat Treatment (열처리에 따른 메탈베어링용 Al-Sn 합금의 미세조직 제어)

  • Kim, Jin-Soo;Park, Tae-Eun;Hahn, Chun-Feng;Sohn, Kwang-Suk;Kim, Dong-Gyu
    • Journal of Korea Foundry Society
    • /
    • v.29 no.1
    • /
    • pp.45-51
    • /
    • 2009
  • Conventionally, Al-Sn bearing manufacturing involves casting the Al-Sn alloy and roll-bonding to a steel backing strip. This article will describe the microstructural control of Al-Sn metal bearing alloy following heat treatment. When the pure aluminum rod dipped in the melt of tin maintained below the melting point of aluminum, the melting of aluminum was accelerated with penetration of tin along the grain boundary of aluminum. The length of plate-shaped eutectic tin was decreased with heat treatment time. With even longer heat treatment time over 1 hour the length of eutectic tin didn't decrease any more, while resulting in coarsening of aluminum matrix. Exuded liquid of eutectic tin was formed at the surface of Al-Sn alloy after heat treatment even at below eutectic temperature.