• Title/Summary/Keyword: Heat Accumulation

Search Result 226, Processing Time 0.028 seconds

An experimental study of behavior of defrosting on the fin-tube heat exchanger (핀-관 열교환기에 대한 제상 거동에 관한 실험적 연구)

  • Lee, Kwan-Soo;Kim, Kyu-Woo;Ji, Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.649-657
    • /
    • 1998
  • In this study, the effects of the various conditions of frosting and defrosting on the behavior of defrosting in a fin-tube heat exchanger have been examined experimentally. The electric heater is used for defrosting in a fin-tube heat exchanger It is shown that there are several local maxima in the water draining rate. The amount of residual water on the heat exchanger after the completion of defrosting is kept constant due to surface tension on the heat exchanger. Without considering the degradation of the thermal performance due to the frosting, the defrosting efficiency is improved with increasing amount of the frost irrespective of the frosting condition. The defrosting behavior is affected by the frosting density as well as the frost accumulation, which vary with the experimental operating conditions during the frosting period. The heat loss to the surrounding air decreases, and the melting and defrosting efficiencies show high values with decreasing heat input.

  • PDF

STUDY ON THE PREVENTION METHOD FOR HEAT ACCUMULATION FOR PERSONAL RAPID TRANSIT (PRT) VEHICLE UNDER BODY (PRT 차량하부 열부하 저감방안 도출 연구)

  • Kwon, S.B.;Song, J.H.;Kang, S.W.;Jeong, R.G.;Kim, H.B.;Lee, C.H.;Seo, D.K.
    • Journal of computational fluids engineering
    • /
    • v.18 no.1
    • /
    • pp.58-62
    • /
    • 2013
  • Personal Rapid Transit (PRT) is the emerging personal transport vehicle operating on the loop automatically. The PRT system utilize the electrical power from super capacity or battery, it is important to manage the power or energy. In this regards, the management of high temperature occurred by the operation of system is significantly important to prevent from serious damage of component. In this study, we studied the adequate shape of underbody which can reduce the heat accumulation by pickup coil and condenser using natural air cooling. We suggested the additional air pathway, air inlet and flow separator to decrease the temperature of the heat source components. It was found that suggested system can decrease the temperature of PRT under body by 16% during the static mode and by 10% during the running mode at 30km/h. It is expected that the findings of this study will feed into final design of newly built Korean PRT vehicle.

Suggestion on experimental animal model of the dermatitis with dampness-heat syndrome in the traditional Korean medicine

  • Lim, Dahae;Go, Jihyun;Hong, Sungwei;Kang, Sangwoo;Yoou, Myoung-Schook;Kim, Na-Rae;Nam, Sun-Young
    • CELLMED
    • /
    • v.5 no.1
    • /
    • pp.2.1-2.2
    • /
    • 2015
  • According to the traditional Korean medicine, Dampness-heat (DH)is an abnormal state of the body that results in a pathological accumulation of dampness and heat. DH is caused by overeating fatty, sweet foods or overdrinking alcohol. Exposure to hot and humid atmospheres is another cause of DH. Although many experimental animal model on various diseases related with DH syndrome were established, DH syndrome dermatitis model is not established. Thus, we introduce the experimental animal model of the dermatitis with DH syndrome.

Improving the Thermal Environment of Balcony in Apartment House (공동주택 발코니의 열환경 향상방안)

  • Park, Sun-Hyo;Bae, Sang-Hanw;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.41-46
    • /
    • 2003
  • In recent days, it is usual case to extend the dwelling area to the balcony which is provided by service area. But the use of the extended area can be arisen discomfort with a view point of thermal environment by excessive heat accumulation in summer and excessive cold draft in winter. In this study, the skills were reviewed to improve the thermal environment of the extended area and evaluations were carried out. Additional heat supply by heat-convector installed at the lower end of the curtain wall can improve the thermal environment of the extended area and also arise surface temperature of the curtain wall surface. And aluminum plate installed under the floor could not improve the thermal environment but it was effective to shortening the initial heating time.

  • PDF

Pre-strain Effect on the Bauschinger Phenomenon of Non-Heat Treatable Cold Forging Steel (냉간 비조질강의 바우싱거 효과에 미치는 변형량의 영향)

  • Ha J. G.;Kwon Y. N.;Kim S. W.;Lee Y. S.;Lee J. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.326-329
    • /
    • 2005
  • Since the required strength of forged part is achieved by work hardening with the accumulation of plastic strain during the cold working, severe load can be exerted on die system. So, dies are liable to the early fracture for the non-heat treated steel forging in comparison with the conventional mild steels. Therefore, it is necessary to lower the flow stress of steels as much as possible during forging steps. Bauschinger effect can be utilized to lower flow stress during forging steps by giving the tensile prestrain on the forging billet during wire drawing step. In the present study, the prestrain effect on Bauschinger phenomenon is studied to avoid difficulties with application of non-heat treated cold forging steels in practice.

  • PDF

ELECTRICAL FIRE (전기화재)

  • Park, Heon-Sik
    • Fire Protection Technology
    • /
    • s.11
    • /
    • pp.13-22
    • /
    • 1991
  • To understand electrical fire, the cause of it is classified into overcurrent, short circuit, leak, joint, overheat, accumulation of heat, spark, deterioration of insulation, static electricity, and lightning etc. and explained. And then by the precautions to it, proposed to the improvement of electric products, the completeness of safecty management and the use of alarm systems.

  • PDF

Syndrome Differentiation of Low Back Pain Presented in Uibujeonrok and Donguibogam in Korean Medicine (의부전록(醫部全錄)과 동의보감(東醫寶鑑)에 제시된 한의학적 요통(腰痛) 분류(分類)에 대한 소고(小考))

  • Lim, Hansol;Nam, Donghyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.3
    • /
    • pp.173-184
    • /
    • 2015
  • Objectives The purpose of this study is to understand formation courses of the ten types of LBP (十種腰痛) in Korean medicine through reviewing classic literatures. Methods We summarized sentences describing syndrome differentiation of LBP directly in Uibujeonrok (醫部全錄) and Donguibogam (東醫寶鑑), and then organized similarities and differences among diagnostic factors described in the classic literatures. Results In most of the classics LBP was classified according to the cause but the causes varied depending on the classic literatures. Cheonkeumbang (千金方) tried to suggest a reasonable classification of LBP in a relatively early age. In Dangyesimbeop (丹溪心法) the causes of LBP were divided into 6 factors; qi movement stagnation (氣鬱), dampness-heat (濕熱), kidney deficiency (腎虛), static blood (瘀血), sprain (挫閃) and phlegm accumulation (積痰). It had a lot of influence on the classic literatures published later. Donguibogam was also influenced by the Dangyesimbeop and the ten types of LBP in Donguibogam was similar to the information on the classification shown in Uihakipmun (醫學入門) and Uijongpildok (醫宗必讀). Conclusions We verified universality of the ten types of LBP; kidney deficiency, phlegm-retained fluid (痰飮), food accumulation (食積), sprain, static blood, wind (風), cold (寒), dampness (濕), dampness-heat and qi (氣).

Ginsenosides Rg1 regulate lipid metabolism and temperature adaptation in Caenorhabditis elegans

  • Hao Shi ;Jiamin Zhao ;Yiwen Li ;Junjie Li ;Yunjia Li;Jia Zhang ;Zhantu Qiu ;Chaofeng Wu ;Mengchen Qin ;Chang Liu ;Zhiyun Zeng ;Chao Zhang ;Lei Gao
    • Journal of Ginseng Research
    • /
    • v.47 no.4
    • /
    • pp.524-533
    • /
    • 2023
  • Background: Obesity is a risk factor for aging and many diseases, and the disorder of lipid metabolism makes it prominent. This study aims to investigate the effect of ginsenoside Rg1 on aging, lipid metabolism and stress resistance Methods: Rg1 was administered to Caenorhabditis elegans (C. elegans) cultured in NGM or GNGM. The lifespan, locomotory activity, lipid accumulation, cold and heat stress resistance and related mRNA expression of the worms were examined. Gene knockout mutants were used to clarify the effect on lipid metabolism of Rg1. GFP-binding mutants were used to observe the changes in protein expression Results: We reported that Rg1 reduced lipid accumulation and improved stress resistance in C. elegans. Rg1 significantly reduced the expression of fatty acid synthesis-related genes and lipid metabolism-related genes in C. elegans. However, Rg1 did not affect the fat storage in fat-5/fat-6 double mutant or nhr-49 mutant. Combined with network pharmacology, we clarified the possible pathways and targets of Rg1 in lipid metabolism. In addition, Rg1-treated C. elegans showed a higher expression of anti-oxidative genes and heat shock proteins, which might contribute to stress resistance Conclusion: Rg1 reduced fat accumulation by regulating lipid metabolism via nhr-49 and enhanced stress resistance by its antioxidant effect in C. elegans.

Evaluation of Thermal Environment in the Detached Housing Area Based on the Form-Based Codes (형태기반코드를 기반으로 한 주거지 열환경 평가)

  • Ryu, Ji-Won;Jung, Eung-Ho
    • Journal of the Korean housing association
    • /
    • v.25 no.5
    • /
    • pp.43-50
    • /
    • 2014
  • This study assesses thermal environment of detached housing area by classifying buildings types with codes based on spatial characteristics and forms of the detached housing area and applying heat island alleviation measures, especially focused on FBCs (Form-Based Codes). We analyzed shapes and materials of outdoor space with 3D-CAD, which can affect the surface temperature of the case studies, focusing on heat island alleviation measures, and performed space design by applying relevant climate factors to a simulation. As to the 3D surface temperature and HIP distribution, low-temperature distribution was shown in the case studies when we applied heat island alleviation measures. FBCs (Form- Based Codes) is being developed for the purpose of creating new urban environment. This study is significant because it pays attention to the effects of surface temperatures on accumulation of sensible heat and reviews heat island alleviation measures with outdoor space shapes/materials in order to lower surface temperatures, aiming at improved pleasantness of the detached housing area.

A study on the heat treatment processing of 7050 aluminum alloy (7050Al 합금의 열처리공정 개발에 관한 연구)

  • Lee, H.S.;Nam, T.W.;Lee, B.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.2
    • /
    • pp.139-146
    • /
    • 1996
  • The aero-industry is union industry which includes a research development type, a knowledge accumulation type and a developed country type. The aero-industry of Korea is in semi-developed type stage but departed later than that of other country such as Taiwan, Indonesia etc. Therefore, the necessity of domestic airplane material is required. This study on 7050Al extruded alloy aims to suggest an adequate heat treatment conditions of T73, T74 and T76. The results of this study show that; 1. The optimum conditions of T7x heat treatment in extruded 7050Al alloy show this; $$T73:121^{\circ}C{\times}7hr+177^{\circ}C{\times}14hr$$. $$T74:121^{\circ}C{\times}7hr+177^{\circ}C{\times}10hr$$. $$T76:121^{\circ}C{\times}7hr+163^{\circ}C{\times}21hr$$. 2. The 2nd step aging heat treatment such as T73, T74 and T76 etc. is efective in 7050Al alloy but the variation otf microstructure and mechanical property with dispersive inclusions produced for extrusion process causes some troubles. Accordingly, in order to produce a good 7050Al alloy, a careful attention is needed in manufacturing process.

  • PDF