• 제목/요약/키워드: Heart valve transplantation

검색결과 23건 처리시간 0.018초

Heart Transplantation in a Patient with Persistent Left Superior Vena Cava

  • Lee, Jae-Hong;Park, Eun-Ah;Lee, Whal;Cho, Hyun-Jai;Kim, Ki-Bong;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.533-535
    • /
    • 2014
  • A 56-year-old male presented with severe exertional dyspnea and pitting edema in the lower extremities. The preoperative evaluation demonstrated biventricular dysfunction associated with severe tricuspid valve regurgitation and a persistent left superior vena cava. He was registered as a transplantation candidate, and orthotopic heart transplantation was performed using the standard bicaval technique. The left superior vena cava was connected to the right atrial appendage after the construction of a conduit using the recipient's autologous coronary sinus tissue. One-month postoperatively, computed tomography imagery demonstrated a patent conduit between the left superior vena cava and right atrial appendage.

초저온 냉동보관법을 이용한 동종판막 이식술에 대한 연구 (Aortic and Pulmograft Transplantation Utilizing Cryopreservation)

  • 송명근;이동순
    • Journal of Chest Surgery
    • /
    • 제23권4호
    • /
    • pp.622-639
    • /
    • 1990
  • The use of aortic valve homograft has been developed since 1962 when Ross and Barratt - Boyes independently replaced a diseased aortic valve with an orthotopically inserted homograft valve. And also surgical treatment of complex congenital cardiac malformations utilizing homograft extracardiac conduit has been tried with better result than any other prosthetic material. The present study was undertaken to clarify the safety tissue viability, sterility, after following our protocol of procurement of heart, dissection of aortic and pulmonic homograft, sterilization, cryopreservation, thawing and dilution, and transplantation on experimental animal, sheep. Tissue viability of valve and great artery was assessed by tissue culture. Sterility was evaluated by bacterial and fungal culture. The method used was proven no deleterious effect on the integrity of the valve. Tissue culture of valve tissue before, and after cryopreservation process resulted that active fibroblast growth was observed from homograft sterilized with antibiotics. And culture of the transplanted homograft from sacrificed animal showed active fibroblast growth. Pathologic examination of implanted valve tissue from sacrificed sheep showed mild calcification and minor change, but there were moderate and severe calcification of wall of great arteries.

  • PDF

동맥근 농양 및 좌심실유출호 가성 심실류 환자에서 폐동맥 자가이식편을 이용한 대동맥근부치환술 -1례 치험 보고- (Aortic Root Replacement with Pulmonary Autograft in Patient with Subaortic Abscess and False Aneurysm in Left Ventricular Outflow Tract -Report of A Case-)

  • 장병철
    • Journal of Chest Surgery
    • /
    • 제28권7호
    • /
    • pp.704-707
    • /
    • 1995
  • The use of the patient`s pulmonary valve for replacement of the patient`s diseased aortic valve was introduced and developed by Mr. Donald Ross. The long term benefits of having a normal, fully viable, trileaflet semilunar valve in aortic position was demonstrated. A 38 year old male had histories of failures of previously implanted aortic prosthetic valves twice and evidence of progressive heart failure. At operation, aortic root abscess was found; the abscess extension to adjacent structures and partial valve dehiscence had occurred. The patient underwent replacement of the aortic root with autologous pulmonary valve, autologous pericardial patch repair of left ventricuar outflow tract and recontruction of the right ventricular outflow tract and pulmonary artery with prosthetic valved conduit. Postoperatively, the patient recovered well. Postoperative doppler echocardiography demonstrated minimal central regurgitation in new aortic valve. Aortic root replacement with pulmonary autograft in a patient of recurrent aortic root abscess and false aneurysm of left ventricuar outflow tract was experienced and reported with follow up echocardiography.

  • PDF

선천성 심질환을 가진 3개월 소아에서 장기간의 체외 막형 산소화 보조 후 몸무게 차이가 큰 공여자-수용자간 심장 이식 (Transplantation of an Extremely Oversized Heart after. Prolonged Extracorporeal Membrane Oxygenation Assistance in a 3-month-old Infant with Congenital Heart Disease)

  • 조현진;서동만;장원경;박천수;김영휘
    • Journal of Chest Surgery
    • /
    • 제42권5호
    • /
    • pp.630-634
    • /
    • 2009
  • International Society for Heart and Lung Transplantation (ISHLT)는 2007년 보고에서 선천성 심질환, 1세 미만의 나이, 이식 당시 체외 막형 산소화 보조가 심장 이식 후 사망의 유의한 위험 요소임을 보고하였으며, 몸무게 차이가 클 경우에도 사망의 위험도를 높인다고 하였다. 이 증례의 환아는 심한 좌심실 유출로 협착, 승모판 폐쇄 부전이 있어 Ross수술과 승모판 성형술을 시행하였으나 술 후 심한 좌심실 기능부전으로 체외 막형 산소화 보조를 적용하였다. 체외 막형 산소화 보조 30일이 경과한 생후 3개월 경 공여자-수용자간 몸무게 비가 4.42에 이르는 매우 큰 심장을 성공적으로 이식하였기에 이식의 기술적인 주요 사항을 문헌 고찰과 함께 보고하는 바이다.

송아지에 이식한 공기구동형 인공심장의 혈역학적 연구 (Hemodynamic study of Pneumatic Artificial Heart Implanted in Calves)

  • 박표원
    • Journal of Chest Surgery
    • /
    • 제23권3호
    • /
    • pp.438-451
    • /
    • 1990
  • Pneumatic total artificial heart[TAH] has been clinically applied for the purpose of permanent or temporary use followed by cardiac transplantation in the patients with end stage heart diseases. In spite of the good durability of the pneumatic TAH, thrombus formation, bleeding and infection resulted in death. The Tomasu heart, which is a type of pneumatic TAH, was used in this study. This model is a modified Jarvik heart and consists of atrial cuffs, outflow vascular grafts and thin-layer seamless diaphragm type of ventricles. Cardiac outputs of the left artificial heart were measured by Donovan`s mock circulation under variable conditions of driving parameters, and an experimental artificial heart implantation was performed in 4 calves to observe the changes of hemodynamic parameters in early postoperative period and hematologic and bio-chemical changes in a long-term survival case. In the mock circulation test, cardiac output of the heart was increased with the increase of the left atrial pressure and left driving pressure. Maximum cardiac output was obtained at the heart rate of 120 to 130/min and percent systole of 40 to 45Zo under the condition of a constant left driving pressure of 180mmHg and left atrial pressure of 10mmHg. During the first 24 hours of TAH pumping, driving pressure ranged from 178$\pm$5mmHg to 187$\pm$8mmHg for the left heart and from 58$\pm$6mmHg to 78$\pm$28mmHg for the right heart. The Mean arterial pressure significantly increased between 2 and 8 hours after the start of pumping. The survival time ranged from 27 hours to 46 days. The causes of death were respiratory failure in 2 cases, mechanical valve failure in one, and left ventricular outflow obstruction due to thrombus in a 46-day survival case. This study demonstrated that Tomasu artificial heart operated effectively during the first 24 hours of artificial heart pumping, but thrombus formation around the valve holding area was the main problem in long-term survival case.

  • PDF

Outcomes after Mechanical Aortic Valve Replacement in Children with Congenital Heart Disease

  • Joon Young Kim;Won Chul Cho;Dong-Hee Kim;Eun Seok Choi;Bo Sang Kwon;Tae-Jin Yun;Chun Soo Park
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.394-402
    • /
    • 2023
  • Background: The optimal choice of valve substitute for aortic valve replacement (AVR) in pediatric patients remains a matter of debate. This study investigated the outcomes following AVR using mechanical prostheses in children. Methods: Forty-four patients younger than 15 years who underwent mechanical AVR from March 1990 through March 2023 were included. The outcomes of interest were death or transplantation, hemorrhagic or thromboembolic events, and reoperation after mechanical AVR. Adverse events included any death, transplant, aortic valve reoperation, and major thromboembolic or hemorrhagic event. Results: The median age and weight at AVR were 139 months and 32 kg, respectively. The median follow-up duration was 56 months. The most commonly used valve size was 21 mm (14 [31.8%]). There were 2 in-hospital deaths, 1 in-hospital transplant, and 1 late death. The overall survival rates at 1 and 10 years post-AVR were 92.9% and 90.0%, respectively. Aortic valve reoperation was required in 4 patients at a median of 70 months post-AVR. No major hemorrhagic or thromboembolic events occurred. The 5- and 10-year adverse event-free survival rates were 81.8% and 72.2%, respectively. In univariable analysis, younger age, longer cardiopulmonary bypass time, and smaller valve size were associated with adverse events. The cut-off values for age and prosthetic valve size to minimize the risk of adverse events were 71 months and 20 mm, respectively. Conclusion: Mechanical AVR could be performed safely in children. Younger age, longer cardiopulmonary bypass time and smaller valve size were associated with adverse events. Thromboembolic or hemorrhagic complications might rarely occur.

Long-Term Outcomes of Homografts in the Aortic Valve and Root Position: A 20-Year Experience

  • Kim, Joo Yeon;Kim, Joon Bum;Jung, Sung-Ho;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제49권4호
    • /
    • pp.258-263
    • /
    • 2016
  • Background: The advantages of using a homograft in valve replacement surgery are the excellent hemodynamic profile, low risk of thromboembolism, and low risk of prosthetic valve infection. The aim of this study was to evaluate the long-term outcomes of homograft implantation in the aortic valve position. Methods: This is a retrospective study of 33 patients (>20 years old) who underwent aortic valve replacement or root replacement with homografts between April 1995 and May 2015. Valves were collected within 24 hours from explanted hearts of heart transplant recipients (<60 years) and organ donors who were not suitable for heart transplantation. The median follow-up duration was 35.6 months (range, 0 to 168 months). Results: Aortic homografts were used in all patients. The 30-day mortality rate was 9.1%. The 1- and 5-year survival rates were $80.0%{\pm}7.3%$ and $60.8%{\pm}10.1%$, respectively. The 1-, 5-, and 10-year freedom from reoperation rates were $92.3%{\pm}5.2%$, $68.9%{\pm}10.2%$, and $50.3%{\pm}13.6%$, respectively. The 1-, 5-, and 10-year freedom from significant aortic dysfunction rates were $91.7%{\pm}8.0%$, $41.7%{\pm}14.2%$, and $25.0%{\pm}12.5%$, respectively. Conclusion: Homografts had the advantages of a good hemodynamic profile and low risk of thromboembolic events, and with good outcomes in cases of aortitis.

심장-폐 이식 증례 보고 (A Case Report of Heart-Lung Transplantation)

  • 노준량;허재학;오삼세;김영태;이정렬;이기봉;오병희;한성구
    • Journal of Chest Surgery
    • /
    • 제31권10호
    • /
    • pp.1004-1008
    • /
    • 1998
  • 본 논문은 동맥관개존증으로 인한 Eisenmenger 증후군 환자에서 시행된 심장-폐이식 수술에 대한 증례 보고이다. 동맥관 개존증으로 인한 Eisenmenger 증후군인 32세의 여자 수혜자는 1996년 6월 이후 심부전으로 심한 호흡곤란을 겪고 있었으며, 1997년 7월초에 빈맥, 호흡곤란, 하지부종을 주소로 응급실을 통하여 입원한 후 호흡곤란, 저산소증, 상심실성 빈맥, 전해질 이상 등으로 치료받으면서 퇴원하지 못하고 심장-폐 이식 대상자로 등록되었다. 수술전에 시행한 심초음파검사에서 우-좌단락의 동맥관개존증, 우심실 및 우심방의 심한 확장, 100 mmHg의 우심실 수축기압 소견을 보였다. 폐동맥압이 체동맥압보다 높게 역전되어 있었고 심한 이산화탄소 정체 및 저산소증의 소견을 보여서 중환자실에서 인공호흡기로 호흡기능을 보조받고 있었다. 공여자는 교통사고로 두부손상을 입고 뇌사판정을 받은 1 8세 남자였다. 공여자 및 수헤자의 혈액형은 모두 AB(+)형이었다. 1997년 10월 26일 심장-폐이식을 시행하였다. 심장 -폐분절은 공여자가 있던 타병원에서 구득하여 냉장보존 상태로 본원으로 이송하였다. 이식된 심장 및 폐의 총 허혈 시간은 각각 249분 및 270분이었다. 면역억제요법은 cyclosporine, azathioprine을 수술전부터 투여하였으며 steroid 는 기관 문합부위의 치유와 감염예방을 위하여 수술후 3주 이후부터 사용하였다. 환자는 수술후 31일째에 특별한 합 병증없이 퇴원하였으며 심장-폐이식후 4개월이 지난 현재, 심폐기능의 이상소견과 거부반응의 증거없이 NYHA funct ional class I의 상태로 지내고 있으며 면역억제제와 예방적 항생제, 소량의 이뇨제 및 항고혈압제를 복용하고 있다.

  • PDF

심내막염 환자의 동종대동맥편을 이용한 대동맥 근부 치환술 - 1례 보고 - (Aortic Root Replacement Using Aortic Homograft in Acute Bacterial Endocarditis One Case Report)

  • 임창영;이헌재
    • Journal of Chest Surgery
    • /
    • 제30권8호
    • /
    • pp.819-822
    • /
    • 1997
  • 세균성 심내막염에 의한 대동맥판 폐쇄부전의 수술치료에 있어서, 우수한 혈역학적 기능과 염증에 대한 높은 저항력 때문에 동종대동맥판을 사용한 수술이 우선적으로 고려되고 있다. 수술방법중에서 대동 맥근부 치환술이 관상동맥하 부착법에 비하여 술 후 대동맥관 폐쇄부전이 적게 발생하는 장점을 갖는다. 46세의 남자가 세균성 심내막염에 의한 급성 대동백판 폐쇄부전 및 심부전으로 내원하였다. 내과적 치료에 반응하지 않고 심부전이 점차 심해져서 20 m동종대동맥편을 이용한 대동맥근부 치환수술을 응급으로 시행하였다. 수술소견상 우관상판첨에 구멍이 나 있었고 좌, 우관상판첨사이의 교련에 심한 석회화가 있었다. 수술후 환자는 순조로이 회복되었고 심초음파검사상 이식된 동종동맥 판의 폐쇄부전소견 은 발견되지 않았다. 염증소견들도 술 후 8주간의 항생제투여로 소실되었다. 약물치료로 조절되지 않는 세균성 심내막염에 의한 급성 대동맥판 폐쇄부전을 동종동맥 판을 사용한 대동맥근부 치환수술로써 성 공적으로 치료하였다.

  • PDF

동종 동맥판의 생육성 평가에 관한연구(I) (Viability Assay of Cardiac Allograft (I))

  • 임창영
    • Journal of Chest Surgery
    • /
    • 제27권1호
    • /
    • pp.1-8
    • /
    • 1994
  • Allograft cardiac valves have been used for over 30 years to replace diseased cardiac valves, reconstruct right or left ventricular outflow tract. With increasing its requirement, the establishment of a viable bank capable of maintaining the viability of graft over a prolonged period would be desirable. The method for determining the viability of allograft by metabolic assay technique using radiolabeled aminoacids has been used recently. An experimental study was done for evaluation of viability of cardiac allograft which was preserved for 14 days at 4oC in nutrient medium[fresh preservation] by metabolism assay technique using 3H-glycine. Also, the effectiveness of low concentration antibiotic solution[CLPV] for sterilization was evaluated. The effectiveness of CLPV solution for sterilization of allograft was perfect. Pre-treatment cultured organisms were not cultured after treatment at all in every cases. The viability of allograft after sterilization was reduced to 66.4%[aortic wall], 74.7%[pulmonary wall], 76.3%[aortic valve], 67.9%[aortic wall]. And after the fresh preservation for 14 days, the viability was reduced to 14.7%, 18.5%, 17.7%, 19.0%, respectively.In conclusion, viability of allograft was reduce to 71.3[66.4-76.3]% after sterilization and 17.5[14.7-19.0]% after fresh preservation. And sterilization effect of CLPV solution was satisfactory.

  • PDF