• Title/Summary/Keyword: Heart rate strain

Search Result 26, Processing Time 0.018 seconds

Heart Rate Strain of Forest-workers in Timber Harvesting Operation (심박수를 이용한 임목수확작업의 작업강도 분석)

  • Baek, Seung-An;Lee, Eun-Jai;Nam, Ki-Hun;Cho, Koo-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.593-601
    • /
    • 2020
  • This study was conducted to analyze the physical strain with heart rate monitor in timber harvesting operations in order to reduce occupational accidents. The timber harvesting activities are manual cutting(felling, limbing and bucking) with a chainsaw and extraction by cable yarder. The study took place on Japanese larch stand. The average height was 26m and average diameter at breast height(DBH) was 3 7cm. The havest unit was gentle slope to steep slope. Results showed that the heart rate increases for chocking, felling, limbing and bucking were 94.0%, 87.9%, 84.8% and 56.4% respectively. The rate of Work Load Index was higher in the limbing(61.4%) activity than other activities chocking(55.2%), felling(54.1%) and bucking(32.1%). During 50% working heart rate test it was found that limbing(1.09), chocking(1.05) and felling(1.04) was exposed to high work intensity compared to bucking(0.83). The results showed that maximum acceptable work times(felling, chocking and limbing) were 2.30 hour, 1.85 hour and 1.60 hour respectively. To avoid occupational accidents, timber harvest workers may use a suitable working hour schedule to felling, chocking, limbing.

Study on Pathogenicity of Borrelia burgdorferi Sensu Lato Isolated in Korea (국내에서 분리된 Borrelia burgdorferi Sensu Lato의 병원성 연구)

  • Park, Kyung-Hee;Lim, Jung-A;Kim, Jong-Hyun;Park, Eui-U
    • The Journal of the Korean Society for Microbiology
    • /
    • v.34 no.5
    • /
    • pp.471-478
    • /
    • 1999
  • Spirochetes were isolated from the midgut of Ixodes persulcatus ticks captured at Chungju, Korea and identified as Borrelia afzelii strains by polymerase chain reaction. To determine the pathogenicity of the B. afzelii strains isolated in Korea, the microbiological and pathological features of Lyme disease were observed in C3H/He mice after intraperitoneal inoculation of the fresh isolate of B. afzelii strain. The results are summarized as follows 1) The Borrelia were detected in the tissues of heart, spleen, kidney, urinary bladder and knee joint within 7 days after inoculation of infection by dark field microscopic examination. The isolation rate from heart, urinary bladder and joint was significantly higher than the rate from spleen, kidney, and blood samples. 2) The Borrelia was detected in heart muscle by indirect immunofluorescent antibody test. 3) Antibody to the Borrelia was detected as early as one week after inoculation. 4) The marked tropism of the Borrelia was observed in myocardial, urinary tract and joint tissue. The main pathological features are inflammation in tissues of heart, kidney, joint and urinary bladder. From these results, the Borrelia afzelii strain isolated in Korea were determined as pathogenic strain.

  • PDF

A Study on the Evaluations of Compression Force for the Prevention of Low Back Pain : Nine-step Stretching Exercises (요통 예방을 위한 요추부하 평가에 관한 연구)

  • Yang, S.H.;Kim, D.S.;Park, P.;Kal, W.M.;Kang, Y.S.
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.248-255
    • /
    • 1998
  • The objective of this study is to conduct the prevention method using electromyography that is to resist the strain on L5/S1 disc and to measure the heart rate for the prevention of low back pain during lifting. EMG signals and heart rate were analyzed under the condition of fixed vertical factor (20∼80cm), two horizontal factors (35cm, 55cm), and two weight factors (10kg, 25kg) 2 times per minute for each lifting task. Eight healthy male workers performed nine-step stretching exercises which were intensified back power at the L5/S1 disc for six months. After completion of the two trials, the results were compared. The results of this analysis show that EMG signals have more an effect on the weight than the horizontal factors similar to those analyzed previous study, and are decreased. Therefore, those exercises presented very efficient. Also, there are not statistically significant differences on the analysis result of heart rate between weight factors.

  • PDF

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor (홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현)

  • Jin, Sang-Gon;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

Developing Liquid Cooling Garments to Alleviate Heat Strain of Workers in Summer and Exploring Effective Cooling Temperature and Body Regions (여름철 작업자들의 고체온증 예방을 위한 액체냉각복 개발 및 효과적인 냉각온도와 인체 냉각부위 탐색)

  • Jung, Jae-Yeon;Kang, Juho;Seol, Seonhong;Lee, Joo-Young
    • Fashion & Textile Research Journal
    • /
    • v.22 no.2
    • /
    • pp.250-260
    • /
    • 2020
  • The purpose of the present study was to explore the most effective body region and cooling temperature to alleviate heat strain of workers in hot environments. We developed liquid cooling hood, vest, sleeves and socks and applied the water temperatures of 10, 15, 20, and 25℃ through the liquid cooling garments in a hot and humid environment (33℃ air temperature and 70% RH air humidity). A healthy young male participated in a total of 16 experimental trials (four cooling garments × four cooling temperatures) with the following protocol: 10-min rest, 40-min exercise on a treadmill and 10-min recovery. The results showed that rectal temperature, mean skin temperature, and ratings of perceived exertion during exercise; heart rate and diastolic blood pressure during recovery; and total sweat rate were lower for the vest condition than other garment conditions(p < .05). However, there was no differences in mean skin temperature among the four cooling garments when we compared the values converted by covering area(%BSA). When we classified the results by cooling temperature, there were no consistent differences in thermoregulatory and cardiovascular responses among the four temperatures, but 25℃ water temperature was evaluated as being the most ineffective cooling temperature in terms of subjective responses. In conclusion, the results indicated that wearing cooling vest with < 20℃ cooling temperature can alleviate heat strain of workers in hot and humid environments. If the peripheral body regions are cooled with liquid cooling garments, larger cooling area with lower cooling temperature than 10℃ would be effective to reduce heat strain of workers. Further studies with a vaild number of subjects are required.

Study of Efficient Cooling Part for Cooling Clothes Development (냉각복 개발을 위한 효율적 냉각부위 규명에 관한 연구)

  • 최정화;황경숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.6
    • /
    • pp.771-778
    • /
    • 2002
  • Cooling clothes especially cooling vest are being considered for as an efficient way to reduce heat strain under hot environment. But wearing ice gel or ice-based cooling vest caused discomfort to subjects due to the weight of vest. Therefore, this study was executed to find efficient cooling parts and to reduce vest weight by cooling only these parts. Two male subjects were exposed to heat(40$^{\circ}C$, 30%RH) with A type(breast+back+abdomen+waist), B type(breast+back+waist), C type(breast+back+abdomen) and D type(breast+back) cooling vest that distinguished with cooling part. The results were as follows; When subjects were C type and D type vest, sweat volume was less and skin temperature was low. Heart rate and rectal temperature were low in B type and D type. These results suggest that excessive cooling of breast and abdomen may exert a bad influence to health and cooling of back is desirable.

Influence of Osmolarity of Cardioplegic Solution in the Myocardial Function - Comparison between the YUMC and the St.Thomas Hospital Cardioplegic Solution - (심마비용액의 삼투압이 심근보호에 미치는 영향 - 연세의대 심마비용액과 성토마스병원 심마비용액의 비교 연구 -)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.22 no.6
    • /
    • pp.927-935
    • /
    • 1989
  • Using an isolated Rat heart preparation of the Sprague Dawley strain, the YUMC cardioplegic solution k the St. Thomas Hospital Cardioplegic Solution were compared in the non waking K working heart perfusion systems by evaluating the hemodynamics, [bio] chemical, and light microscopic finding The heart rate k coronary flow of the two groups in the 20 minutes post ischemic recovery time were 288.6*6.5 vs 283.7*12 and 21.3*1.0 vs 19.0*1.7 respectively with no statistical significance existing. However the aortic systolic pressure, aortic overflow, cardiac output which were 81.7[4.2 vs 78.4*1.8, 18.3*1.1 vs 13.0*2.5 and 36.9*0.9 vs 32.0*3.2 respectively with P < 0.01 indicate that the comparison of these three parameters is statistically meaningful. The amount of CPK extracted in the 20 minutes post 120 minutes of ischemia was compared for the two cardioplegic solution, the results of which turned out to be similar, light microscopic findings were also found to be similar. It is thought that the YUMC cardioplegic solution provided better results than the St. Thomas hospital solution because of the differing composition of the two solution such as glucose, mannitol, albumin were put only in the former solution enhancing osmolarity of the cardioplegic solution providing better hemodynamic results.

  • PDF

Thermal and subjective responses by sun hats for farmer in a hot climatic chamber (서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응)

  • 김명주;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.5
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.

An Experimental Study on Artificial Infection of Olive Flounder Paralichthys olivaceus by Streptococcus parauberis Using Different Injection Sites (넙치(Paralichthys olivaceus)의 Streptococcus parauberis 인위감염을 위한 공격실험 방법에 관한 연구)

  • Kim, Tae-Ho;Lee, Nam-Sil;Choi, Hye-Sung;Jung, Sung-Hee;Han, Hyun-Ja
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.4
    • /
    • pp.628-636
    • /
    • 2020
  • Streptococcosis in the olive flounder Paralichthys olivaceus can be caused by Streptococcus parauberis. We compared three routes of administration for experimental injections of the S. parauberis 19FBSPa0003 strain in the olive flounder. Pathological changes were observed during the experimental infection. Inflammation of the serous membrane in the liver, intestine, spleen and heart was the major pathological change found in the infected olive flounder. No mortality was observed in fish that received intraperitoneal (IP) injection at less than 1×104 colony-forming unit (CFU)/fish. The lethal dose 50 for olive flounder, given an intravenous (IV) injection, was 7.94×104 CFU/fish. Fish with a higher concentration of IV injected S. parauberis (1×108 CFU/fish) died within a maximum of two days. However, serious necrosis and bacterial proliferation in ellipsoidal cells of the spleen and heart tissues were found in moribund or dead fish, 1-2 days after IV injection. Similar histopathological signs were observed in olive flounder inoculated by subcutaneous (SC) infected and naturally infected. In addition, SC was also strongly associated with bacteria concentration and cumulative mortality rate. Based on these results, SC is the recommended method for artificial infection by S. parauberis in the olive flounder.

Efficacy of Cooling Vests for Alleviating Heat Strain of Farm Workers in Summer (여름철 농민의 서열 부담 경감을 위한 냉각조끼의 성능 평가)

  • Choi Jeong-Wha;Kim Myung-Ju;Lee Joo-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.8 s.145
    • /
    • pp.1176-1187
    • /
    • 2005
  • The purpose of this study was to evaluate the efficiency of cooling vests developed for farm workers harvesting red pepper in summer. The study was performed using the following two steps: 1) Climatic chamber test, 2) Field test. For the chamber test, a work environment was simulated as $33^{\circ}C$ and $65\%$RH, and the thermo-physiological and subjective responses were measured with and without cooling vests. Twelve young males participated as subjects. For the field test, three farmers participated while harvesting red pepper on the form, in summer. The measurements used were same as in the chamber test. Subjects were tested without any cooling vests, as a control. They were tested wearing vests with 2 frozen gel packs (CV2: Cooling area, $308cm^2$), and vests with 4 frozen gel packs (CV4: Sooting area, $616cm^2$). As a result of the chamber test, rectal temperature($T_{re}$) and mean skin temperature( $T_{sk}$) were lower in both CVs than in Control, and this tendency was statistically significant in CV4 (p<.05). Clothing microclimate temperature ($T_{clo}$) and total sweat rate (TSR) were significantly lower when wearing cooling vests (p<.05) Heart rate (HR) was also lower in wearing cooling vests than in Control, and the speed of recovery to the comfort level was faster when the subjects wore cooling vests. In addition, subjects felt 'less hot, less humid, and less uncomfortable' in both CVs than in Control. Field tests showed a similar tendency with the chamber tests. In particular, wearing the cooling vest was effective in restraining the raise of $T_{clo}$ on the back. It can be concluded that the cooling vest was effective in alleviating heat strain and discomfort in both the chamber test and the field test, despite the cooling area of the cooling vest being just $3.4\%$ of the body surface area ($616cm^2$).