• Title/Summary/Keyword: Heart PET

Search Result 49, Processing Time 0.025 seconds

Clinical Application of $^{18}F-FDG$ PET in Gastric Cancer (위암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yun, Mi-Jin;Kim, Tae-Sung;Hwang, Hee-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.39-45
    • /
    • 2008
  • PET or PET/CT detects only less than 50% of early gastric cancer and 62-98% of advanced gastric cancer. Therefore, mass screening programs are recommended for all adults over the age of 40 for early detection and early treatment of gastric cancer through endoscopy or various radiological tests. The most important step after diagnosis of gastric cancer is accurate staging, which mainly evaluates tumor resectability to avoid unnecessary surgery. Important factors that affect tumor resectability are whether the tumor can be separated from adjacent organs or important blood vessels, the extent of lymph node metastasis, presence of peritoneal metastasis, or distant organ metastasis. To evaluate the extent of local tumor invasion, anatomical imaging that has superior spatial resolution is essential. There are a few studies on prognostic significance of FDG uptake with inconsistent results between them. In spite of lower sensitivity for lymph node staging, the specificity of CT and PET are very high, and the specificity for PET tends to be higher than that for CT. Limited data published so far show that PET seems less useful in the detection of lung and bone metastasis. In the evaluation of pleural or peritoneal metastasis, PET seems very specific but insensitive as well. When FOG uptake of primary tumor is low, distant metastasis also tends to show low FDG uptake reducing its detection on PET. There are only a few data available in the evaluation of recurrence detection and treatment response using FDG PET or PET/CT.

In a Universal Design Viewpoint Usability Evaluation Research to PET Bottle (유니버설 디자인 관점에서의 PET BOTTLE에 대한 사용성 평가 연구)

  • Kim Sang-Sik
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.166-169
    • /
    • 2005
  • While use of a pet bottle with use it is light recently and convenient increases quickly, it is used from the child, also diffusing the user to a pet bottle to people of various classes, such as an old person, a woman, a male, the man in the street, and a disabled person. However, those who are standardized on the basis of the common man with the plan energy of a pet bottle, and cannot attain to the standard, That is, a child and a disabled person may be condemned to the vague situation that a lid cannot be opened or a contents thing cannot be drunk without external help. And the characteristic of a material and production which are called PET Even if convenience is emphasized for the cost reduction of COST, a design is chosen easily, and even if it calls it the man in the street, the point of coming to experience a situation with the difficult time of use can be found well. In research of a book, problem derivation which classifies entering school and a preschool man-and-woman child for a child drink for an object first by the viewpoint of universal design paying attention to such problems, and leads the actual use example of a pet bottle was carried out in true heart, and various notional approach was shown by the solution method.

  • PDF

Clinical Application of $^{18}F-FDG$ PET in Bile Duct Cancer (담도암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yun, Mi-Jin;Kim, Tae-Sung;Hwang, Hee-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.66-70
    • /
    • 2008
  • Reports about FDG PET in biliary tumor are limited and there are almost no reports regarding its efficacy. Biliary tumor is divided to intrahepatic and extrahepatic bile duct cancer, and intrahepatic bile duct cancer can be further divided to peripheral type which occurs at lobular duct and hilar type which occurs at hepatic hilum. Surgical resection is the only curative method for bile duct tumor, and accurate staging plays an important role in deciding treatment modality. Among intrahepatic bile duct tumors, peripheral type and hilar type have the same histological characteristics, but different clinical manifestations and tumor growth pattern. On PET image, FDG uptake is also different between peripheral type and hilar type. Most of the former shows high FDG uptake at primary and metastasis site so it is very useful for determining stage and changing treatment plans. However, the later is diversified among low uptake and very high uptake. The FDG uptake pattern of hilar type is similar to that of extrahepatic bile duct cancer, and mucinous component is an important factor, which affects FOG uptake. When tumor cells are scattered in desmoplatsic stroma, then FDG uptake is low as well. In contrast, when FDG uptake is high, it is likely to be tubular type which has high tumor density. Tumor growth pattern also affects FDG uptake. Nodular type mostly takes higher FDG compared to infiltrative type. There are many cases where benign inflammatory diseases take high FDG that PET alone can not distinguish malignant lesion from benign lesion. In conclusion, studies about PET using FDG are still limited. Thus, it is hard to make accurate conclusion about the roles of PET or PET/CT in biliary cancers, but peripheral type intrahepatic bile duct cancers and mass forming hilar and extrahepatic bile duct cancers appear to be good indications performing FDG PET or PET/CT.

18FDG Synthesis and Supply: a Journey from Existing Centralized to Future Decentralized Models

  • uz Zaman, Maseeh;Fatima, Nosheen;Sajjad, Zafar;Zaman, Unaiza;Tahseen, Rabia;Zaman, Areeba
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10057-10059
    • /
    • 2015
  • Positron emission tomography (PET) as the functional component of current hybrid imaging (like PET/CT or PET/MRI) seems to dominate the horizon of medical imaging in coming decades. $^{18}$Flourodeoxyglucose ($^{18}FDG$) is the most commonly used probe in oncology and also in cardiology and neurology around the globe. However, the major capital cost and exorbitant running expenditure of low to medium energy cyclotrons (about 20 MeV) and radiochemistry units are the seminal reasons of low number of cyclotrons but mushroom growth pattern of PET scanners. This fact and longer half-life of $^{18}F$ (110 minutes) have paved the path of a centralized model in which $^{18}FDG$ is produced by commercial PET radiopharmacies and the finished product (multi-dose vial with tungsten shielding) is dispensed to customers having only PET scanners. This indeed reduced the cost but has limitations of dependence upon timely arrival of daily shipments as delay caused by any reason results in cancellation or rescheduling of the PET procedures. In recent years, industry and academia have taken a step forward by producing low energy, table top cyclotrons with compact and automated radiochemistry units (Lab-on-Chip). This decentralized strategy enables the users to produce on-demand doses of PET probe themselves at reasonably low cost using an automated and user-friendly technology. This technological development would indeed provide a real impetus to the availability of complete set up of PET based molecular imaging at an affordable cost to the developing countries.

Importance of PET/CT Scan Use in Planning Radiation Therapy for Lymphoma

  • Milana, Mitric-Askovic;Marko, Erak;Miroslav, Latinovic;Tihomir, Dugandzija
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.2051-2054
    • /
    • 2015
  • Background: Radiation therapy is a key part of the combined modality treatment for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), which can achieve locoregional control of disease. The 3D-conformal radiation oncology can be extended-field (EFRT), involved-field (IFRT) and involved node (INRT). New techniques have resulted in a smaller radiation field and lower dose for critical organs such as lung heart and breast. Materials and Methods: In our research, we made a virtual simulation for one patient who was treated in four different radiotherapeutic techniques: mantle field (MFRT), EFRT, IFRT and INRT. After delineatiion we compared dose-volume histograms for each technique. The fusion of CT for planning radiotherapy with the initial PET/CT was made using Softver Xio 4.6 in the Focal program. The dose for all four techniques was 36Gy. Results: Our results support the use of PET/CT in radiation therapy planning. With IFRT and INRT, the burden on the organs at risk is less than with MFRT and EFRT. On the other hand, the dose distribution in the target volume is much better with the latter. Conclusions: The aim of modern radiotherapy of HL and NHL is to reduce the intensity of treatment and therefore PET/CT should be used to reduce and not increase the amount of tissue receiving radiation.

State of the Art of Imaging Equipment and Tools for Nuclear Cardiology (심장핵의학 검사를 위한 영상장비 및 도구의 최신동향)

  • Lee, Byeong-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.165-173
    • /
    • 2009
  • Nuclear cardiology in Korea is less active, compared to nuclear oncology, but it has been specialized and ramified. Lately, sophisticated nuclear cardiac imaging methods provide more convenience for patients. It is necessary to accurately estimate the recent progress in the imaging devices for nuclear cardiology. Myocardial perfusion imaging is a well established study to evaluate heart function. Myocardial perfusion SPECT and PET have been used for assessment of coronary artery disease with various radiopharmaceuticals. And of late, the development of advanced imaging devices - multi-pinhole technique and high definition imaging technique - and software made the scanning time shorter and expanded the application field. Therefore, it is required to review the nuclear cardiology hardware/software for the clinical practice and research. In this review, the characteristics about recently-developed SPECT/PET and software for nuclear cardiology are described. It is hoped that this information would contribute to improving the activity of nuclear cardiac research in Korea where the research for the fusion imaging combining a and nuclear imaging is drawing more attention.

Beneficial effects of Paeo-tang on cardiovascular and renal function in L-NAME-induced hypertensive rats (파어탕의 L-NAME 유도 고혈압 동물군에서의 혈압강하효과 및 심신기능 개선 효과)

  • Na, Se Won;Hong, Mi Hyeon;Kim, Hye Yoom;Jang, Youn Jae;Yoon, Jung Joo;Lee, Yun Jung;Kang, Dae Gill;Lee, Ho Sub
    • Herbal Formula Science
    • /
    • v.28 no.3
    • /
    • pp.271-280
    • /
    • 2020
  • Hypertension has been approved to cause disharmony between the heart and kidney such as cardiac hypertrophy and kidney dysfunction. In traditional oriental medicine Paeo-tang (PET) has been shown to have effects on blood circulation improvement. However, the beneficial effect of PET on hypertension remains unknown. In this study, we investigated that PET attenuates blood pressure and improves cardiovascular and renal function in NG-nitro-L-arginine methylester (L-NAME) rat model. Hypertensive rat models were induced by the administration of L-NAME (40 mg/kg/day) and then PET (50 or 100 mg/kg/day) or Olmetec was treated for 2 weeks. PET treatment significantly suppressed the systolic blood pressure and decreased intima-media thickness in the thoracic aorta. PET ameliorated endothelium-dependent and independent vascular relaxation in the L-NAME-induced vascular dysfunction. PET ameliorated the functional decline in the kidney such as albumin and blood urea nitrogen in plasma. These results demonstrated that PET possesses protective effects against L-NAME-induced hypertension.

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

PET/CT SUV Ratios in an Anthropomorphic Torso Phantom (의인화몸통팬텀에서 PET/CT SUV 비율)

  • Yeon, Joon-Ho;Hong, Gun-Chul;Kang, Byung-Hyun;Sin, Ye-Ji;Oh, Uk-Jin;Yoon, Hye-Ran;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • The standard uptake values (SUVs) strongly depend on positron emission tomographs (PETs) and image reconstruction methods. Various image reconstruction algorithms in GE Discovery MIDR (DMIDR) and Discovery Ste (DSte) installed at Department of Nuclear Medicine, Seoul Samsung Medical Center were applied to measure the SUVs in an anthropomorphic torso phantom. The measured SUVs in the heart, liver, and background were compared to the actual SUVs. Applied image reconstruction algorithms were VPFX-S (TOF+PSF), QCFX-S-350 (Q.Clear+TOF+PSF), QCFX-S-50, VPHD-S (OSEM+PSF) for DMIDR, and VUE Point (OSEM) and FORE-FBP for DSte. To reduce the radiation exposure to radiation technologists, only the small amount of radiation source 18F-FDG was mixed with the distilled water: 2.28 MBq in the 52.5 ml heart, 20.3 MBq in the 1,290 ml liver and 45.7 MBq for the 9,590 ml in the background region. SUV values in the heart with the algorithms of VPFX-S, QCFX-S-350, QCFX-S-50, VPHD-S, VUE Point, and FOR-FBP were 27.1, 28.0, 27.1, 26.5, 8.0, and 7.4 with the expected SUV of 5.9, and in the background 4.2, 4.1, 4.2, 4.1, 1.1, and 1.2 with the expected SUV of 0.8, respectively. Although the SUVs in each region were different for the six reconstruction algorithms in two PET/CTs, the SUV ratios between heart and background were found to be relatively consistent; 6.5, 6.8, 6.5, 6.5, 7.3, and 6.2 for the six reconstruction algorithms with the expected ratio of 7.8, respectively. Mean SNRs (Signal to Noise Ratios) in the heart were 8.3, 12.8, 8.3, 8.4, 17.2, and 16.6, respectively. In conclusion, the performance of PETs may be checked by using with the SUV ratios between two regions and a relatively small amount of radioactivity.