• Title/Summary/Keyword: Healthcare systems

Search Result 765, Processing Time 0.027 seconds

Analysis of Healthcare Convergence on Bacterial Contamination of Radiological Equipment in Emergency Rooms of General Hospitals (종합병원 응급실내의 영상의학과 장비에서의 세균 오염에 관한 보건학적 융합 분석)

  • Hong, Dong-Hee;Park, Mi-Soon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2017
  • It is to establish preliminary data about healthcare convergencr of infection control by performing a bacterial contamination test for CT scanner as well as general radiographic systems in the emergency rooms of general hospitals. The period was December 1 ~ December 31, 2015. It is detect in the emergency rooms of 7 medical facilities including 2 in Seoul, and 1 in Gyeonggi-do Province, and 2 in Jeonla-do Province, and 2 in Chungcheong-do Province. The surface contamination strains detected from CT scanner in the radiology department emergency rooms were Micrococcus species(4,5%), Stenotrophomonas maltophilia(9%), Enterococcus faecium(4.5%), Providencia stuartii(4.5), and Gram negative bacilli(4.5%). Also, the surface contamination strains detected from general radiographic system in the radiology department emergency rooms were Providencia stuartii(11%), Klebsiella pneumonia(3.5%), Stenotrophomonas maltophilia(11%), Pantoea species(11%), Acinetobacter baumannii(3.5%), Micrococcus species(3.5%), Escherichia coli(3.5%), Enterobacter species(3.5%), and Gram negative bacilli(11%). Considering that the regions of most detection were all the places closely related to patients, radiologists would have to thoroughly clean with alcohol before and after a test.

Analysis on the Assist Characteristics for the Knee Extension Motion of Lower Limb Orthosis Using Muscular Stiffness Force Feedback (근육 강성도 힘 피드백을 이용한 하지 보조기의 무릎 신전 운동 보조 특성 분석)

  • Kim, K.;Kang, S.R.;Jeong, G.Y.;Joo, S.J.;Kim, N.G.;Kwon, T.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.217-226
    • /
    • 2010
  • The lower limb orthosis with a pneumatic rubber actuator, which is intended for the assistance and the enhancement of muscular activities of lower limbs was developed in this study. Compared to other knee extension assistive devices being developed by other researchers, our device is designed especially for the elderly people and intended only for slight assistance so that the subjects can keep their muscular strength. For the effectiveness of system, muscular activities of major muscles in lower limbs during sit-to-stand (STS) and squat motion were measured and analyzed. Subjects were performed the STS and squat motion with and without lower limb orthosis. We made comparison muscular activities between with and without lower limb orthosis. Lower limb orthosis was controlled using muscular stiffness force feedback that is controlled by muscular activities of the measured muscle from force sensor. For analysis of muscular activities, electromyography of the subjects was measured during STS and squat motion, and these were measured using MP 150(BIOPAC Systems, Inc.). Muscles of interest were rectus femoris(RF), vastus lateralis(VL), vastus medialis(VM) and vastus intermedius(VI) muscles in lower limbs of the right side. A biodex dynamometer was used to measure the maximal concentric isokinetic strength of the knee extensors of wearing and not wearing orthosis on right side. The test were performed using the concentric isokinetic mode of test with the velocity set at 60°/s for muscles around the knee joints. The experimental result showed that muscular activities in lower limbs wearing orthosis using muscular stiffness force of a vastus medialis muscle was reduced and knee extension torque of an knee joint wearing lower limb orthosis was increased. With this, we confirmed the effectiveness of the developed lower limb orthosis.

The way to achieve Universal Health Coverage: Focusing on the Historical and Cultural Context of Health Care Sector in Vietnam (보편적 건강보장을 향한 노정 : 베트남 보건의료 부문의 역사·문화적 맥락을 중심으로)

  • BEAK, Yong Hun
    • The Southeast Asian review
    • /
    • v.28 no.1
    • /
    • pp.173-218
    • /
    • 2018
  • This study focuses on the healthcare sector in Vietnam which is promoting universal health insurance for the achievement of Universal Health Coverage (UHC) under Sustainable Development Goals (SDGs). The purpose of this study is to examine the characteristics of the reform process of the health care system and the law on health insurance through the historical and cultural contexts and its implications from the perspective of development. Based on the three dimensions of UHC - extension of protection for population, provision of various medical services, and financial protection, the current status of the Vietnam healthcare sector is summarized respectively as follows. First, according to the revised Health Insurance law which came into effect in 2015, the mandatory health insurance premiums are calculated based on household units. Second, there is a medical network that can provide preventive and healthcare services centered on primary health care facilities, for example commune health stations (trạm y $t{\hat{e}}$ $X{\tilde{a}}$). Third, out-of-pocket expenditure is still a large proportion although public spending has increased and private spending has decreased since the enforcement of the health insurance law and various schemes. Vietnam is currently striving towards a universal health care system. The development of institutions and systems should be designed in a way that is appropriate for the members of the society rather than efficiency. This article findings shed light on the role of social values, family culture, and informal institutions.

Analysis of the Needs of Field Experts for the Provision of Rehabilitation Sports Activities Services for the Disabled (장애인 재활운동 및 체육활동 서비스 제공을 위한 현장 전문가 요구도 분석)

  • Kang, Dong-Heon;Park, Ji-Young;Eun, Seon-Deok
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.213-231
    • /
    • 2021
  • Due to the absence of rehabilitation sports service systems linked to post-discharge medical measures and rehabilitation, disabled people cannot participate in physical activities suitable for individual disability types, characteristics, and physical functions. In December 2017, the Act on the Rights of Health for the Disabled) was implemented to provide an institutional basis for disable people to address their needs for rehabilitation sports. Based on related studies conducted in Korea, this study aims to collect the results of a demand survey conducted on experts who are rehabilitation sports service providers and analyze the demand for rehabilitation sports services from a policy perspective. This study extracts the needs of experts presented in the literature and presents the extracted content as an inductive content analysis. The criteria for selecting the literature were selected based on studies related to "adaptive physical activity and exercise," "sports for all for the disabled," and "rehabilitation sports" conducted in the Republic of Korea, including the results of a demand survey on experts. The study results were categorized into seven categories (perception of sports activities, programs, leaders, facilities, accessibility, cost/support/financial resources, and others) of field experts who are rehabilitation sports service providers. In a future study, it will be necessary for people with disability, who are consumers who will provide actual services, to identify problems at the disabled sports site and come up with measures to improve them.

Private Blockchain and Biometric Authentication-based Chronic Disease Management Telemedicine System for Smart Healthcare (스마트 헬스케어를 위한 프라이빗 블록체인과 생체인증기반의 만성질환관리 원격의료시스템)

  • Young-Ae Han;Hyeok Kang;Keun-Ho Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.1
    • /
    • pp.33-39
    • /
    • 2023
  • As the number of people with chronic diseases increases due to an aging society, it is urgent to prevent and manage their diseases. Although biometric authentication methods and Telemedicine Systems have been introduced to solve these problems, it is difficult to solve the security problem of medical information and personal authentication. Since smart healthcare includes personal medical information of subjects, the security of personal information is the most important field. Therefore, in this paper, we tried to propose a Telemedicine System using a smart wearable device ECG in the form of a wristband and face personal authentication in a private blockchain environment. This system targets various medical personnel and patients with chronic diseases in all regions, and uses a private blockchain that can increase data integrity and transparency, ECG and face authentication that are difficult to forge and alter and have high personal identification to provide a system with high security and reliability. composed. Through this, it is intended to contribute to increasing the efficiency of chronic disease management by focusing on disease prevention and health management for patients with chronic diseases at home.

Legislation Status and Legal Issues of Non-Face-to-Face Treatment (비대면진료 관련 입법 현황과 법적 쟁점)

  • Jinsuk, Kim;Eol, Lee
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.4
    • /
    • pp.131-160
    • /
    • 2023
  • An amendment to Medical Law allowing permanent face-to-face treatment has been proposed in the 21st National Assembly, with five different bills introduced. However, each proposed amendment focuses on different aspects, and the issue is currently in a state of 'ongoing review' due to factors such as opposition from the medical profession and political considerations. However, from the perspective that the introduction of non-face-to-face treatment should be institutionalized and legislated prioritizing patient safety, certain directions are proposed. These include focusing on returning patients as the primary target, chronic diseases as the focal conditions, outpatient medical institutions as the implementing agencies, restricting non-face-to-face means primarily to video systems, and legally exempting healthcare professionals from responsibility for incidents beyond their control. The proposed directions also emphasize establishing the right to demand face-to-face treatment. It is suggested to legislate initial standards that ensure a minimum level of safety and gradually expand the scope of non-face-to-face treatment through future research, evaluation, and similar step-by-step approaches.

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Evaluation of the Modulation Transfer Function for Computed Tomography by Using American Association Physics Medicine Phantom (컴퓨터단층검사에서 AAPM Phantom을 이용한 변조전달함수 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Kwon, Kyung-Tae;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.193-198
    • /
    • 2016
  • In clinical computed tomography (CT), regular quality assurance (QA) has been required. This study is to evaluate the MTF for analyzing the spatial resolution using AAPM phantom in CT exam. The dual source somatom definition flash (siemens healthcare, forchheim, Germany), the brilliance 64 (philips medical system Netherlands) and aquilion 64 (toshiba medical system, Japan) were used in this study. The quantitative evaluation was performed using the image J (wayne rasband national institutes of health, USA) and chart method which is measurement of modulation transfer function (MTF). In MTF evaluation, the spatial frequencies corresponding to the 50% MTF for the CT systems were 0.58, 0.28, and $0.59mm^{-1}$, respectively and the 10% MTF for the CT systems were 1.63, 0.89, and $1.21mm^{-1}$, respectively. This study could evaluate the characteristic of spatial resolution of MTF using chart method, suggesting the quantitative evaluation method using the data.

Deep Learning Algorithm and Prediction Model Associated with Data Transmission of User-Participating Wearable Devices (사용자 참여형 웨어러블 디바이스 데이터 전송 연계 및 딥러닝 대사증후군 예측 모델)

  • Lee, Hyunsik;Lee, Woongjae;Jeong, Taikyeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.6
    • /
    • pp.33-45
    • /
    • 2020
  • This paper aims to look at the perspective that the latest cutting-edge technologies are predicting individual diseases in the actual medical environment in a situation where various types of wearable devices are rapidly increasing and used in the healthcare domain. Through the process of collecting, processing, and transmitting data by merging clinical data, genetic data, and life log data through a user-participating wearable device, it presents the process of connecting the learning model and the feedback model in the environment of the Deep Neural Network. In the case of the actual field that has undergone clinical trial procedures of medical IT occurring in such a high-tech medical field, the effect of a specific gene caused by metabolic syndrome on the disease is measured, and clinical information and life log data are merged to process different heterogeneous data. That is, it proves the objective suitability and certainty of the deep neural network of heterogeneous data, and through this, the performance evaluation according to the noise in the actual deep learning environment is performed. In the case of the automatic encoder, we proved that the accuracy and predicted value varying per 1,000 EPOCH are linearly changed several times with the increasing value of the variable.

Risk Factors for COVID-19 Infection Among Healthcare Workers. A First Report From a Living Systematic Review and meta-Analysis

  • Dzinamarira, Tafadzwa;Nkambule, Sphamandla Josias;Hlongwa, Mbuzeleni;Mhango, Malizgani;Iradukunda, Patrick Gad;Chitungo, Itai;Dzobo, Mathias;Mapingure, Munyaradzi Paul;Chingombe, Innocent;Mashora, Moreblessing;Madziva, Roda;Herrera, Helena;Makanda, Pelagia;Atwine, James;Mbunge, Elliot;Musuka, Godfrey;Murewanhema, Grant;Ngara, Bernard
    • Safety and Health at Work
    • /
    • v.13 no.3
    • /
    • pp.263-268
    • /
    • 2022
  • Health care workers (HCWs) are more than ten times more likely to be infected with coronavirus infectious disease 2019 (COVID-19) than the general population, thus demonstrating the burden of COVID-19 among HCWs. Factors that expose HCWs to a differentially high-risk of COVID-19 acquisition are important to elucidate, enable appropriate public health interventions to mitigate against high risk and reduce adverse outcomes from the infection. We conducted a systematic review and meta-analysis to summarize and critically analyze the existing evidence on SARS-CoV-2 risk factors among HCWs. With no geographical limitation, we included studies, in any country, that reported (i) the PCR laboratory diagnosis of COVID-19 as an independent variable (ii) one or more COVID-19 risk factors among HCWs with risk estimates (relative risk, odds ratio, or hazard ratio) (iii) original, quantitative study design, and published in English or Mandarian. Our initial search resulted in 470 articles overall, however, only 10 studies met the inclusion criteria for this review. Out of the 10 studies included in the review, inadequate/lack of protective personal equipment, performing tracheal intubation, and gender were the most common risk factors of COVID-19. Based on the random effects adjusted pooled relative risk, HCWs who reported the use of protective personal equipment were 29% (95% CI: 16% to 41%) less likely to test positive for COVID-19. The study also revealed that HCWs who performed tracheal intubations were 34% (95% CI: 14% to 57%) more likely to test positive for COVID-19. Interestingly, this study showed that female HCWs are at 11% higher risk (RR 1.11 95% CI 1.01-1.21) of COVID-19 than their male counterparts. This article presents initial findings from a living systematic review and meta-analysis, therefore, did not yield many studies; however, it revealed a significant insight into better understanding COVID-19 risk factors among HCWs; insights important for devising preventive strategies that protect them from this infection.