• Title/Summary/Keyword: Healthcare Devices

Search Result 421, Processing Time 0.026 seconds

A Study on the Software Fault Modes and Effect Analysis for Software Safety Evaluation (소프트웨어 안전성 평가를 위한 소프트웨어 고장 유형과 영향 분석에 관한 연구)

  • Kim, Myong-Hee;Park, Man-Gon
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.1
    • /
    • pp.115-130
    • /
    • 2012
  • These days, most of safety-critical systems, which are systems those failures or malfunction may result in death or serious injury to people, or loss or severe damage to social systems, or environmental harm, are being built of embedded software or loaded controlling software systems on computers, electrical and electronic components or devices. There are a lot kind of fault analysis methods to evaluate safety of the safety-critical systems equipped computers, electrical and electronic components or devices with software. However, the only assessment method to evaluate software safety of a safety-critical system is not enough to analysis properly on account of the various types and characteristic of software systems by progress of information technology. Therefore, this paper proposes the integrated evaluation method and carries out a case study for the software safety of safety-critical system which embedded or loaded software sizes are small and control response times are not sensitive by use of two security analysis methods which are Fault Tree Analysis (FTA) and Fault Modes and Effect Analysis (FMEA) for ubiquitous healthcare system.

Reliable Mobility Management Using CoAP in Internet of Things Environments (사물 인터넷 환경에서 CoAP 기반의 신뢰성 있는 이동성 관리 방법)

  • Chun, Seung Man;Kim, Hyun Su;Ham, Chang Gyun;Chung, Yun Seok;Park, Jong Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.13-18
    • /
    • 2016
  • In Internet of Things (IoT) environment, a variety of smart devices are connected to Internet through various network technologies such as 4G/5G, WiBro, Bluetooth, etc. in order to provide the remote monitoring service such as smart healthcare service, etc. Most standard mobility management protocols based on IETF Mobile IP may not be suitable for Internet of Things (IoT) environments due to constrained power, constrained CPU processing and memory capacity, and large signalling overhead which are inherently accompanied by various devices in IoT environments. In this article, we propose a new mobility management protocol CoMP (CoAP-based Mobility Managemenbt Protocol) for reliable mobility management in IoT environments. The architecture and algorithm to achieve both reliability and simplicity for IoT mobility management are proposed. Finally, performance has been evaluated by both mathematical analysis and simulation.

Design of a Data Grid Model between TOS and HL7 FHIR Service for the Retrieval of Personalized Health Resources (개인화된 건강 자원 조회를 위한 TOS 와 HL7 FHIR 서비스간의 데이터그리드 모델 설계)

  • Jeon, Young-Jun;Im, Seok-Jin;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.4
    • /
    • pp.139-145
    • /
    • 2016
  • On the ICT healing platform designed to issue early disease alerts, TOS connected between the provider of personal health-related data and the service provider and relayed personalized health data. In the previous study, TOS proposed how to monitor the retrieval and management of document/measurement resources by taking mobile devices into account. Recently the healthcare field, however, defined the standard items needed for communication and data exchanges with a mobile device through HL7 FHIR. This study designed a data grid model between TOS and FHIR to provide personal health resources relayed through TOS in FHIR bundle search sets. The proposed design was organized as follows: first, it stated similarities between the method of TOS resource request and that of FHIR observation request. Then, it designed an eventbus module to process a retrieval request for FHIR service based on the imdb and cluster technologies. The proposed design can be used to expand the old service terminals of ICT healing platform to mobile health devices capable of using FHIR resources.

Highly Reliable Triboelectric Rotational Energy Scavenger

  • Lee, Younghoon;Lee, Bada;Choi, Dukhyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.397-397
    • /
    • 2016
  • Triboelectric nanogenerators (TENG) can produce power from ambient mechanical sources and have strong points of high output performance, light weight, low cost, and easy manufacturing process. It is expected that TENG can be utilized in the fields of wireless electronics and self-powered devices in the world which pays attention to healthcare and the IoT. In this work, we focus on scavenging ambient rotational energy by using a durably designed TENG. In previous studies regarding harvesting rotation mode energy, the devices were based on sliding mechanism and durability was not considered as a major issue. However friction by rotation causes reliability problems due to wear and tear. Therefore, in this study, we convert rotary motion to linear motion utilizing a cam by which we can then utilize contact-mode TENG and improve device reliability. In order to increase output performance, bumper springs were used below the TENG and the optimum value for the bumper spring constant was analyzed theoretically. Furthermore, the inserting a soft substrate was proposed and its effect on high output was determined to be due to an increase in the contact area. By increasing the number of cam noses, the output frequency was shown to increase linearly. For the purpose of maximum power transfer, the input impedance of the device was determined. Finally, to demonstrate the use of the C-TENG as a direct power source, it was installed on a commercial bicycle wheel and connected to 180 LEDs. In conclusion we present a rotational motion TENG energy scavenger system designed for enhanced durability and optimized output by appropriate choice of spring constants and substrate.

  • PDF

Position Recognition and User Identification System Using Signal Strength Map in Home Healthcare Based on Wireless Sensor Networks (WSNs) (무선 센서네트워크 기반 신호강도 맵을 이용한 재택형 위치인식 및 사용자 식별 시스템)

  • Yang, Yong-Ju;Lee, Jung-Hoon;Song, Sang-Ha;Yoon, Young-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.494-502
    • /
    • 2007
  • Ubiquitous location based services (u-LBS) will be interested to an important services. They can easily recognize object position at anytime, anywhere. At present, many researchers are making a study of the position recognition and tracking. This paper consists of postion recognition and user identification system. The position recognition is based on location under services (LBS) using a signal strength map, a database is previously made use of empirical measured received signal strength indicator (RSSI). The user identification system automatically controls instruments which is located in home. Moreover users are able to measures body signal freely. We implemented the multi-hop routing method using the Star-Mesh networks. Also, we use the sensor devices which are satisfied with the IEEE 802.15.4 specification. The used devices are the Nano-24 modules in Octacomm Co. Ltd. A RSSI is very important factor in position recognition analysis. It makes use of the way that decides position recognition and user identification in narrow indoor space. In experiments, we can analyze properties of the RSSI, draw the parameter about position recognition. The experimental result is that RSSI value is attenuated according to increasing distances. It also derives property of the radio frequency (RF) signal. Moreover, we express the monitoring program using the Microsoft C#. Finally, the proposed methods are expected to protect a sudden death and an accident in home.

A Implementation of Smart Band and Data Monitoring System available of Measuring Skin Moisture and UV based on ICT (ICT기반의 피부 수분 및 자외선 측정이 가능한 스마트 밴드 및 데이터 모니터링 시스템 구현)

  • Jung, Se-Hoon;Sim, Chun-Bo;You, Kang-Soo;So, Won-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.715-724
    • /
    • 2017
  • Today all kinds of smart devices are being developed with various researches on wearable devices that support smart computing on the human body. Skin diseases continue to rise including freckles, pimples, atopy, and scalp trouble due to the environmental and genetic factors, and people pay bigger medical bills to treat their skin diseases. There is thus a need to develop a smart-phone or table-based smart healthcare imaging system of high portability and diagnostic accuracy capable of analyzing and managing various skin problems related to skin care. This study proposed an integrated system combining the Smart Mi Band, a wearable device using moisture and UV sensors based on IoT, on the hardware part with the sensor information monitoring software.

Safety Management for MR-Guided Interventions

  • Cherkashin, Mikhail;Berezina, Natalia;Serov, Alexey;Fedorov, Artem;Andreev, Georgy;Kuplevatsky, Vladymir
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.3
    • /
    • pp.152-157
    • /
    • 2016
  • Purpose: Operating room management is the serious and complex task for hospital managers and the common approach is to develop relevant standard operational procedures. From patient and staff safety perspective, operating room management should be well-studied and hospital should identify and address any potential risks. Simultaneous usage of different imaging and less-invasive treatment technologies demands strong management control. Materials and Methods: We have formed the multidisciplinary expert panel (surgeons, anesthesiologists, radiologists, healthcare managers etc.) for hybrid theater management standard operational procedure development. On the first stage the general concept of hybrid room design and patient routing was developed. The second stage included the technical details discussion. For patient safety improvement we modified the Surgical Safety Check-list in accordance with potential MRI-related safety challenges and concerns. Results: WHO Surgical Safety Checklist is a simple and easy-to use tool which includes three blocks of question (grouped by the surgery process). We have developed two additional blocks of questions for the intraoperative magnetic resonance investigation. It is very important to have a special detailed routing with a strong control of ferromagnetic devices and anesthesiology care. Conclusion: High-energy MRI (1.5-3.0T) is characterized by potential influence on patient and staff safety in case of hybrid surgery. It is obvious to have a strong managerial control of ferromagnetic devices and anesthesiology care. Surgical Safety Checklist is the validated tool for improving patient safety. Modification and customization of this check-list potentially provides the opportunity for surgery processes improving.

A Study on the Analysis of Behavioral Changes of Smart Devices and the Presentation of the Improved Model (스마트 디바이스 행동변화 애플리케이션 분석을 통한 개선모델 제시)

  • Park, In-Hwa;Kim, Hae-Na;Lee, Youngho
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.225-232
    • /
    • 2014
  • Supply of a smart device has been made with the development of communication networks and growing desire of people to improve the quality of life, the service industry about it have been made with smart devices. Among them, there are various services that can help people change their behavior to healthy life. But it does not have a large impact on the behavior change of performer because its been developed as a general process. Therefore in this study examine development situation about current behavior change applications through application markets. Development current situation can be separated by process to two patterns. As a result we propose behavioral change model that includes integrated change model that one of the behavior theory model, accomplish the goal process of goal setting theory and habit formation phase for automate the changes. Also, we provide appropriate service according to the model that leads motivation, sustainability of the action and positive behavior change to performer. We can expect in many aspects such as ability and motivation than existing service.

Design and Implementation of U-Health System for Active Oxygen Measurement Data based on Mobile Phone (활성산소 측정 데이터를 위한 모바일 기반의 U헬스 시스템 설계 및 구현)

  • Lee, Chang Moo;Oh, Seung Kyo;Choi, Deok Jai
    • Smart Media Journal
    • /
    • v.1 no.4
    • /
    • pp.52-58
    • /
    • 2012
  • In recent years the combination of IT and BT for U-Healthcare Medical Services has attracted popular attention as an alternative for solving health problems due to aging issue. Active oxygen as free radicals causes unstable state of the body resulting to other disease on which approximate 90% of the diseases are associated with active oxygen. The severity is even higher along with increasing age. Therefore, there is a need for systematic management of active oxygen saturation for the elderly and chronic patients. In this paper, the data about active oxygen measurements from the body measurement is sent to the data storage of medical facilities by the service provider. Medical information is measured by devices provided complying with the standard, support and information using Bluetooth communication. Users can check their health status themselves using the proposed system through 3G/4G mobile devices like smart phone to medical institutions in which the smart phone act as a gateway for medical data transferred from patient to medical institutions and vice versa. Users can get and experience a diagnosis and effective U-Environmental Health Services from Medical institutions anywhere using the proposed built system.

  • PDF

Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements (국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Kyoung-Ah;Lee, In-Ja;Kim, Jung-Min
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.