IEMEK Journal of Embedded Systems and Applications
/
v.9
no.3
/
pp.183-191
/
2014
The software running on avionic system is required to be highly reliable and productive. The air transport industry has developed ARINC Specification 653(ARINC653) as a standardized software requirement of avionics computers. The document specifies the interface boundary between avionics application software and the core executive software. Dependability in ARINC 653 is provided by spatial and temporal partitioning whilst fault-tolerance is provided by health monitoring mechanism. Legacy real-time operating systems are used to support ARINC653 health monitor on integrated modular avionics(IMA). However, legacy real-time operating systems are costly and difficult to modify the kernel. In this paper, we suggest a Linux-based ARINC653 health monitor. Functionalities to support ARINC653 health monitor are implemented as a Linux kernel module and its performance is evaluated.
This study was conducted to find qualitative approaches to occupational reference to group health practices. In-depth interviewing was done on 8 subjects health monitor members, owners and occupational nurses, respectively). The major findings were as follows; 1. Visiting health management Useful services were 'health counseling', 'medical examination', 'providing informations about managing diseases', 'agency business in relation to Labour Ministry' and 'giving a recognition about occupational health service to owners'. Insufficiencies were 'lack of treatment service after medical examination' and 'lack of follow up services constantly'. 2. Occupational nursing service Useful services were 'providing health information' and 'counselling about health'. Major contents of occupational nursing services were 'management of occupational and adult diseases' and 'explanation of the results after medical examination'. Insufficiencies were 'deficiency of the place where group health education could be performed', 'lack of additional or closer examinations needed in counselling' and 'discontinuous selection of additional or more exact examinations'. 3. Health monitor members Health monitor members in industries were classified into two. Some were selected by owners and the others were selected simply by considering their administrative abilities such as proficient management of documents. Their major tasks were to connect workers with occupational health management agencies. This study suggests that programs should be developed which enable health monitor members to cooperate with occupational nurses.
Purpose: The present study examines symptoms of VDT syndrome perceived by those nurses reviewing the application of health insurance at hospitals. This study also investigates those factor influencing on the experience of VDT syndrome among those nurses. Method: Data were collected through mail questionnaire survey in April, 2003. Of the 250 questionnaires disseminated, 214 questionnaires were finally analyzed using descriptive statistics and multiple regression analysis through SPSS/PC version 10.0. Result: Of the VDT syndrome, the musculoskeletal symptom score was highest, followed by ophthalmologic symptoms. The musculoskeletal symptoms were higher among younger nurses, having smaller space under the desk, and feeling uncomfortableness of the chair. The ophthalmologic symptoms were higher among those with a bachelor's degree, younger nurses, and those having a light reflection on the computer monitor, and those maintaining less than 40cm between eyes and the monitor. Higher dermatologic symptoms were observed among younger nurses and those using unclear monitor. The psychological symptoms were higher among younger nurses, those having a light reflection on the monitor, those unable to control the height of their chair, and those using uncomfortable chair. The overall symptoms were higher among younger nurses, those having a light reflection on the monitor, and those smaller space under the desk. Conclusion: Primary intervention should be given to those nurses with symptoms of VDT syndrome in order to regain health and prevent further aggravation of the symptoms. In particular, self-care behaviors of the nurses using VDT should be promoted with administrative support.
The purpose of this study is to find out the preference and the needs of old womens on the life support appliances i.e. medication dispenser, video phone, activity monitor and sleep monitor. The appliances may be improved reflecting the result of the questionnaire asking about the preferred functions and designs. The respondents were 141 female seniors of 65 years and older, living in Ulsan city or Cheongju city, Korea. Following is the list of results. (1) The medication dispenser, responded as highly preferred, met some worries over the troubles by power stoppage especially while one is out, letting her forget the medication time. (2) The video phone was worried over the cases of hearing failure by small sound, and watching failure by weakening sight. (3) The activity monitor, like the medication dispenser, was worried about the troubles while one is out or out of the monitoring scope, its expense, and the privacy, (4) The sleep monitor met the worries over the inadequacy for the sleeping mat on the floor and the emission of electromagnetic waves. (5) The preferred designs were (1) white or red standing medication dispenser, (2) wall-mounted video phone working by voice, (3) metal activity monitor sensor with white or yellow bracelet.
Hastie, Thomas;Venske-Parker, Sascha;Aps, Johan K.M.
Imaging Science in Dentistry
/
v.51
no.2
/
pp.137-148
/
2021
Purpose: This study aimed to assess the computer monitors used for analysis and interpretation of digital radiographs within the clinics of the Oral Health Centre of Western Australia. Materials and Methods: In total, 135 computer monitors(3 brands, 6 models) were assessed by analysing the same radiographic image of a combined 13-step aluminium step wedge and the Artinis CDDent 1.0® (Artinis Medical Systems B.V.®, Elst, the Netherlands) test object. The number of steps and cylindrical objects observed on each monitor was recorded along with the monitor's make, model, position relative to the researcher's eye level, and proximity to the nearest window. The number of window panels blocked by blinds, the outside weather conditions, and the number of ceiling lights over the surgical suite/cubicle were also recorded. MedCalc® version 19.2.1 (MedCalc Software Ltd®, Ostend, Belgium, https://www.medcalc.org; 2020) was used for statistical analyses(Kruskal-Wallis test and stepwise regression analysis). The level of significance was set at P<0.05. Results: Stepwise regression analysis showed that only the monitor brand and proximity of the monitor to a window had a significant impact on the monitor's performance (P<0.05). The Kruskal-Wallis test showed significant differences (P<0.05) in monitor performance for all variables investigated, except for the weather and the clinic in which the monitors were placed. Conclusion: The vast performance variation present between computer monitors implies the need for a review of monitor selection, calibration, and viewing conditions.
Lee, Joongho;Song, Young Woong;Na, Seokhee;Chung, Min Keun
Journal of Korean Institute of Industrial Engineers
/
v.32
no.3
/
pp.236-241
/
2006
Monitor height is one of the key factors in the VDT workstation design. Most of the previous studies have focused on traditional VDT workplace where the operators performed data entry or word processing tasks using single monitor. This study aimed to suggest proper monitor height when the main task was monitoring information from different number of information sources. Twelve male students participated in three experiments: single information source (one monitor), two information sources (one monitor and one CCTV), and three information sources (one monitor, one CCTV and a window). Subjects performed monitoring tasks for 10 minutes with 3 different monitor center heights : 89.0 cm (Low), 111.3 cm (Middle), and 124.8 cm (High). Surface EMG signals of five neck muscles, subjective discomfort ratings, preference, and working postures were recorded. Results indicated that the middle height was proper for one monitor condition, but the low monitor height was recommended for more than two information sources.
Objective: This study aims to conduct a comprehensive review of monitoring systems to monitor and manage physical function of community-dwelling elderly living alone and suggest future directions of unobtrusive monitoring. Design: Literature review Methods: The importance of health-related monitoring has been emphasized due to the aging population and novel corona virus (COVID-19) outbreak.As the population gets old and because of changes in culture, the number of single-person households among the elderly is expected to continue to increase. Elders are staying home longer and their physical function may decline rapidly,which can be a disturbing factorto successful aging.Therefore, systematic elderly management must be considered. Results: Frequently used technologies to monitor elders at home included red, green, blue (RGB) camera, accelerometer, passive infrared (PIR) sensor, wearable devices, and depth camera. Of them all, considering privacy concerns and easy-to-use features for elders, depth camera possibly can be a technology to be adapted at homes to unobtrusively monitor physical function of elderly living alone.The depth camera has been used to evaluate physical functions during rehabilitation and proven its efficiency. Conclusions: Therefore, physical monitoring system that is unobtrusive should be studied and developed in the future to monitor physical function of community-dwelling elderly living alone for the aging population.
Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
Journal of the Korean Magnetics Society
/
v.26
no.5
/
pp.168-172
/
2016
The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.
The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.6
no.2
/
pp.187-201
/
1996
This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.