• Title/Summary/Keyword: Health monitor

Search Result 957, Processing Time 0.032 seconds

Linux-based ARINC 653 Health Monitor (리눅스 기반 ARINC 653 헬스 모니터)

  • Yoon, Young-Il;Joe, Hyunwoo;Kim, Hyungshin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.9 no.3
    • /
    • pp.183-191
    • /
    • 2014
  • The software running on avionic system is required to be highly reliable and productive. The air transport industry has developed ARINC Specification 653(ARINC653) as a standardized software requirement of avionics computers. The document specifies the interface boundary between avionics application software and the core executive software. Dependability in ARINC 653 is provided by spatial and temporal partitioning whilst fault-tolerance is provided by health monitoring mechanism. Legacy real-time operating systems are used to support ARINC653 health monitor on integrated modular avionics(IMA). However, legacy real-time operating systems are costly and difficult to modify the kernel. In this paper, we suggest a Linux-based ARINC653 health monitor. Functionalities to support ARINC653 health monitor are implemented as a Linux kernel module and its performance is evaluated.

A Study on Occupational Nursing Services in Small Sacle Industry with Reference to Phenomenological Study (현상학적 방법에 의한 소규모 사업장 산업간호활동에 관한 연구)

  • Jung Moon-Hee;Cho Chung-Min;Lee Soo-Yeon
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.13-22
    • /
    • 1998
  • This study was conducted to find qualitative approaches to occupational reference to group health practices. In-depth interviewing was done on 8 subjects health monitor members, owners and occupational nurses, respectively). The major findings were as follows; 1. Visiting health management Useful services were 'health counseling', 'medical examination', 'providing informations about managing diseases', 'agency business in relation to Labour Ministry' and 'giving a recognition about occupational health service to owners'. Insufficiencies were 'lack of treatment service after medical examination' and 'lack of follow up services constantly'. 2. Occupational nursing service Useful services were 'providing health information' and 'counselling about health'. Major contents of occupational nursing services were 'management of occupational and adult diseases' and 'explanation of the results after medical examination'. Insufficiencies were 'deficiency of the place where group health education could be performed', 'lack of additional or closer examinations needed in counselling' and 'discontinuous selection of additional or more exact examinations'. 3. Health monitor members Health monitor members in industries were classified into two. Some were selected by owners and the others were selected simply by considering their administrative abilities such as proficient management of documents. Their major tasks were to connect workers with occupational health management agencies. This study suggests that programs should be developed which enable health monitor members to cooperate with occupational nurses.

  • PDF

A Study on Symptoms of VDT Syndrome among Health Insurance Review Nurses (보험심사간호사의 VDT 증후군 증상에 관한 연구)

  • Hwnag, Hye-Young
    • Korean Journal of Occupational Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Purpose: The present study examines symptoms of VDT syndrome perceived by those nurses reviewing the application of health insurance at hospitals. This study also investigates those factor influencing on the experience of VDT syndrome among those nurses. Method: Data were collected through mail questionnaire survey in April, 2003. Of the 250 questionnaires disseminated, 214 questionnaires were finally analyzed using descriptive statistics and multiple regression analysis through SPSS/PC version 10.0. Result: Of the VDT syndrome, the musculoskeletal symptom score was highest, followed by ophthalmologic symptoms. The musculoskeletal symptoms were higher among younger nurses, having smaller space under the desk, and feeling uncomfortableness of the chair. The ophthalmologic symptoms were higher among those with a bachelor's degree, younger nurses, and those having a light reflection on the computer monitor, and those maintaining less than 40cm between eyes and the monitor. Higher dermatologic symptoms were observed among younger nurses and those using unclear monitor. The psychological symptoms were higher among younger nurses, those having a light reflection on the monitor, those unable to control the height of their chair, and those using uncomfortable chair. The overall symptoms were higher among younger nurses, those having a light reflection on the monitor, and those smaller space under the desk. Conclusion: Primary intervention should be given to those nurses with symptoms of VDT syndrome in order to regain health and prevent further aggravation of the symptoms. In particular, self-care behaviors of the nurses using VDT should be promoted with administrative support.

  • PDF

A Study on the Preference of Old Women for the Higher Usability of u-Health Life Support Appliances (재가노인 유헬스 생활지원기기의 실용화를 위한 여성노인의 선호)

  • Kim, Sun-Joong;Park, Kyoung-Ok
    • Journal of the Korean housing association
    • /
    • v.20 no.1
    • /
    • pp.101-112
    • /
    • 2009
  • The purpose of this study is to find out the preference and the needs of old womens on the life support appliances i.e. medication dispenser, video phone, activity monitor and sleep monitor. The appliances may be improved reflecting the result of the questionnaire asking about the preferred functions and designs. The respondents were 141 female seniors of 65 years and older, living in Ulsan city or Cheongju city, Korea. Following is the list of results. (1) The medication dispenser, responded as highly preferred, met some worries over the troubles by power stoppage especially while one is out, letting her forget the medication time. (2) The video phone was worried over the cases of hearing failure by small sound, and watching failure by weakening sight. (3) The activity monitor, like the medication dispenser, was worried about the troubles while one is out or out of the monitoring scope, its expense, and the privacy, (4) The sleep monitor met the worries over the inadequacy for the sleeping mat on the floor and the emission of electromagnetic waves. (5) The preferred designs were (1) white or red standing medication dispenser, (2) wall-mounted video phone working by voice, (3) metal activity monitor sensor with white or yellow bracelet.

Impact of viewing conditions on the performance assessment of different computer monitors used for dental diagnostics

  • Hastie, Thomas;Venske-Parker, Sascha;Aps, Johan K.M.
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.137-148
    • /
    • 2021
  • Purpose: This study aimed to assess the computer monitors used for analysis and interpretation of digital radiographs within the clinics of the Oral Health Centre of Western Australia. Materials and Methods: In total, 135 computer monitors(3 brands, 6 models) were assessed by analysing the same radiographic image of a combined 13-step aluminium step wedge and the Artinis CDDent 1.0® (Artinis Medical Systems B.V.®, Elst, the Netherlands) test object. The number of steps and cylindrical objects observed on each monitor was recorded along with the monitor's make, model, position relative to the researcher's eye level, and proximity to the nearest window. The number of window panels blocked by blinds, the outside weather conditions, and the number of ceiling lights over the surgical suite/cubicle were also recorded. MedCalc® version 19.2.1 (MedCalc Software Ltd®, Ostend, Belgium, https://www.medcalc.org; 2020) was used for statistical analyses(Kruskal-Wallis test and stepwise regression analysis). The level of significance was set at P<0.05. Results: Stepwise regression analysis showed that only the monitor brand and proximity of the monitor to a window had a significant impact on the monitor's performance (P<0.05). The Kruskal-Wallis test showed significant differences (P<0.05) in monitor performance for all variables investigated, except for the weather and the clinic in which the monitors were placed. Conclusion: The vast performance variation present between computer monitors implies the need for a review of monitor selection, calibration, and viewing conditions.

Determination of Proper Monitor Height based on the Musculoskeletal Load and Preference during VDT Monitoring Tasks (VDT 모니터링 작업에서 근골격계 부담도 및 선호도에 근거한 모니터 높이 결정)

  • Lee, Joongho;Song, Young Woong;Na, Seokhee;Chung, Min Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.3
    • /
    • pp.236-241
    • /
    • 2006
  • Monitor height is one of the key factors in the VDT workstation design. Most of the previous studies have focused on traditional VDT workplace where the operators performed data entry or word processing tasks using single monitor. This study aimed to suggest proper monitor height when the main task was monitoring information from different number of information sources. Twelve male students participated in three experiments: single information source (one monitor), two information sources (one monitor and one CCTV), and three information sources (one monitor, one CCTV and a window). Subjects performed monitoring tasks for 10 minutes with 3 different monitor center heights : 89.0 cm (Low), 111.3 cm (Middle), and 124.8 cm (High). Surface EMG signals of five neck muscles, subjective discomfort ratings, preference, and working postures were recorded. Results indicated that the middle height was proper for one monitor condition, but the low monitor height was recommended for more than two information sources.

Physical Function Monitoring Systems for Community-Dwelling Elderly Living Alone: A Comprehensive Review

  • Jo, Sungbae;Song, Changho
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • Objective: This study aims to conduct a comprehensive review of monitoring systems to monitor and manage physical function of community-dwelling elderly living alone and suggest future directions of unobtrusive monitoring. Design: Literature review Methods: The importance of health-related monitoring has been emphasized due to the aging population and novel corona virus (COVID-19) outbreak.As the population gets old and because of changes in culture, the number of single-person households among the elderly is expected to continue to increase. Elders are staying home longer and their physical function may decline rapidly,which can be a disturbing factorto successful aging.Therefore, systematic elderly management must be considered. Results: Frequently used technologies to monitor elders at home included red, green, blue (RGB) camera, accelerometer, passive infrared (PIR) sensor, wearable devices, and depth camera. Of them all, considering privacy concerns and easy-to-use features for elders, depth camera possibly can be a technology to be adapted at homes to unobtrusively monitor physical function of elderly living alone.The depth camera has been used to evaluate physical functions during rehabilitation and proven its efficiency. Conclusions: Therefore, physical monitoring system that is unobtrusive should be studied and developed in the future to monitor physical function of community-dwelling elderly living alone for the aging population.

Measurement of MRI Monitor Luminance and MRI Room Illuminance with a Light Probe (Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정)

  • Kim, Ji Min;Han, Ah Yung;Lee, Ha Young;Lee, So Ra;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.168-172
    • /
    • 2016
  • The purpose of the optimal environment of the MRI room to measured luminance and illuminance of the MRI room and the monitor. University Hospital (n = 6) of the MRI (n = 10) in the luminance and illuminance Light Probe Xi Unfors (Unfors Instruments AB, Billdal, Sweden) was measured by using the. Black luminance level and white level of illuminance is repeated three times in the middle of the side of the monitor to obtain the mean and standard deviation using a t-test statistical processing was of significance test. Monitor luminance and black level in the average $1.78cd/m^2$, the standard deviation was $0.85cd/m^2$, white level average of $43.58cd/m^2$, the standard deviation of $13.19cd/m^2$. Illuminance of MRI room was the lowest value measured in accordance with the 30.5 lux, the maximum value is 601.3 lux, mean was measured by a variety of 177.86 lux. Luminance and illuminance of the MRI room and monitor is found to have statistically significant difference (p < .05). In conclusion, refer to the recommended standard of MRI and room monitor luminance and illuminance and to create an optimal environment.

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols

  • Yoo, Sooyoung;Baek, Hyunyoung;Doh, Kibbeum;Jeong, Jiyeoun;Ahn, Soyeon;Oh, Il-Young;Kim, Kidong
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study was to evaluate the accuracy of a mobile wireless digital automatic blood pressure monitor for clinical use and mobile health (mHealth). In this study, a manual sphygmomanometer and a digital blood pressure monitor were tested in 100 participants in a repetitive and sequential manner to measure blood pressure. The guidelines for measurement used the Korea Food & Drug Administration protocol, which reflects international standards, such as the American National Standard Institution/Association for the Advancement of Medical Instrumentation SP 10: 1992 and the British Hypertension Society protocol. Measurements were generally consistent across observers according to the measured mean ${\pm}SD$, which ranged in $0.1{\pm}2.6mmHg$ for systolic blood pressure (SBP) and $0.5{\pm}2.2mmHg$ for diastolic blood pressure (DBP). For the device and the observer, the difference in average blood pressure (mean${\pm}$SD) was $2.3{\pm}4.7mmHg$ for SBP and $2.0{\pm}4.2mmHg$ for DBP. The SBP and DBP measured in this study showed accurate measurements that satisfied all criteria, including an average difference that did not exceed 5 mmHg and a standard deviation that did not exceed 8 mmHg. The mobile wireless digital blood pressure monitor has the potential for clinical use and managing one's own health.

The Sampling Efficiencies of Volatile Organic Compounds(VOCs) to the Diffusive Monitor with Activated Carbon Fiber (활성탄섬유를 이용한 확산포집기의 공기 중 유기용제 포집효율에 관한 연구)

  • Byeon, Sang-Hoon;Park, Cheon-Jae;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.187-201
    • /
    • 1996
  • This study was to evaluate the efficiency of diffusive monitor using activated carbon fiber(ACF, KF-1500) in measuring airborne organic solvents. The following characteristics were identified and studied as critical to the performance of diffusive monitor; recovery, sampling rate, face velocity, reverse diffusion and storage stability. For the evaluation of the performance of this monitor, MIBK, PCE, toluene were used as organic solvents. In the sampling rate experiments, eight kinds of solvents (n-hexane, MEK, DIBK, MCF, TCE, CB, xylene, cumene) as well as the above solvents were used. The results were as follows: 1. The desorption efficiencies(DE's) of ACF diffusive monitor ranged from 83 % to 101 %. In contrast, those of coconut shell charcoal ranged from 78 % to 102 %. Especially, the DE's of ACF for the polar solvents such as MEK were superior to those of charcoal. 2. Experimental sampling rates on ACF were average 42ml/min(37-46ml/min) for 11 organic solvents at $24{\pm}2^{\circ}C$, $50{\pm}5%RH$. However ideal sampling rates(DA/L) were 33 % higher than experimental sampling rates. 3. The initial response(15~16 min) of the testing monitor was 2 times higher than the actual concentration determined by the reference methods at $24{\pm}2^{\circ}C$, $8{\pm}5%RH$ and $80{\pm}5%RH$. Within 1 hours, the curve reached a linear horizontal line at low humidity condition. But sampling efficiencies decreased with respect to time at high humidity condition. And sampling efficiencies were higher at high humidity condition than low humidity condition for MIBK. 4. At very low velocity (less than 0.02 m/sec), the concentration of ACF diffusive monitor were poorly estimated. But ACF diffusive monitor were not affected at higher velocity(0.2 m/sec-0.6 m/sec). 5. There was no significant reverse diffusion when the ACF monitors were exposed to clean air for 2 hours after being exposed for 2 hours at the level of 1 TLV. 6. There was no significant sample loss during 3 weeks of storage at room temperature and 5 weeks of storage at refrigeration.

  • PDF