DEVELOPMENT OF TEM HEAD-SIZE RESONATOR FOR 3T MRI HEAD COIL

  • Ha, Seung-Hoon;Choe, Bo-Young;Lee, Hyoung-Koo;Suh, Tae-Suk;Shinn, Kyung-Sub;Kim, Yong-Sik;Kim, Sung-Eun;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 1999년도 Japanese Journal of Medical Physics
    • /
    • pp.176-177
    • /
    • 1999
  • PDF

1인치 마이크로 드라이브의 동특성 해석 (Dynamic Analysis for 1 inch micro-drive)

  • 황창호;박경수;전정일;박영필;박노철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.592-597
    • /
    • 2003
  • To solve a problem of micro drive due to small size and portability, it is necessary to understand and to investigate micro drive widely ,deeply. So, we performed modal analysis of suspension of micro drive, and load/unload experiment for Input current to VCM coil and disk speed. To determine the effect of ramp profile, curve fitting of lateral speed is performed with equation of speed. The results indicate that small load/unload speeds decrease the number of head/disk contacts, and during unloading process, low disk speed increase the number of head/disk contacts.

  • PDF

비정질 와이어를 센서헤드로 이용한 금속의 미세결함 검출 (Flaw Detection in a Conductor Using Sensor Head of Amorphous Wire)

  • 김영학;신광호
    • 한국자기학회지
    • /
    • 제12권5호
    • /
    • pp.174-178
    • /
    • 2002
  • 미소결함을 가진 금속체에 교류자기장을 인가하면 결함부근에는 와전류의 분포가 달라져 이에 의해 금속체를 관통하는 교류자기장은 결함부근에서 차이를 가진다. 이 교류자기장을 비정질 와이어로 된 센서헤드로 측정하여 센서헤드의 유기전압 크기로부터 결함 유무를 검출하는 방법에 대해 검토하였다. 비정질 와이어는 Co-based재료로 자왜가 거의 0이며 고투자율 자성체이고 비정질 와이어는 길이가 15mm, 직경이 100$\mu\textrm{m}$인 원주형 자성체이다. 실험대상 금속체로 0.5mm의 단일 직선 갭을 가진 두께 1mm의 동판과 0.1mm의 갭이 규칙적으로 배열된 두께 25$\mu\textrm{m}$의 Al 판를 이용하였다. 스파이럴 코일에 인가하는 교류자기장의 주파수는 100KHz~600KHz였다. 본 실험의 결과에서 동판에서는 유기전압의 최대치와 최소치의 차가 약 2.5㎷ 얻어졌고, Al판에서는 500KHz에서 0.4㎷가 얻어져 직선 갭의 유무를 유기전압의 크기만으로 확인할 수 있었다.

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

ACR 팬텀을 이용한 치아 임플란트 자기공명영상 인공물 분석 (Analysis of the Dental Implants MRI Artifacts by Using the ACR Phantom)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제10권8호
    • /
    • pp.629-635
    • /
    • 2016
  • 자기공명영상 장치의 정도관리를 위한 ACR 팬텀은 팬텀내의 여러 구조물을 통하여 자기공명영상 화질을 평가할 수 있다. 본 연구는 3.0T 장비에서 Head coil에서 ACR 팬텀을 이용하여 임플란트와 치아 교정용 철사를 부착하여 영상의 고스트 신호 백분율과 절편 두께 정확도를 분석할 수 있었다. T1강조영상 첫 번째 절편과 열한 번째 절편의 임플란트 보철에서 절편위치 정확도는 수신대역폭이 230에서 좋게 나타났으며, 교정용 철사가 부착했을 때는 수신대역폭이 130일 때가 좋았다. 고스트 신호 백분율은 SE T1강조영상 일곱번째 절편에서 임플란트 보철에 추가된 교정용 철사의 경우에는 수신대역폭 230이 좋게 나타났다. 자기공명영상 검사에서 임플란트 보철 환자의 경우에 적절한 수신대역폭을 선택하여 영상의 왜곡과 신소 소실이 감소된 영상을 획득할 수 있을 것으로 사료된다.

자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가 (Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

자기공명영상검사 시 신호강도를 높이기 위한 보상물질의 간접부착 방식에 관한 연구 (A Study on Indirect Attachment Method of Compensation Materials to Increase Signal Intensity in Magnetic Resonance Imaging)

  • 손순룡
    • 한국콘텐츠학회논문지
    • /
    • 제17권7호
    • /
    • pp.437-442
    • /
    • 2017
  • 최근 자기공명신호를 형성시키지 않는 보상물질을 이용하여 신호강도를 높이려는 연구가 활발히 진행되면서 검사부위에 보상물질을 직접 부착함에 따른 환자감염의 우려가 나타나고 있다. 이에 본 연구에서는 발상의 전환으로 보상물질을 코일에 간접 부착함으로써 기존의 직접 부착방식을 대체할 수 있는지 알아보고자 하였다. 연구방법은 보상물질인 실리콘을 원통형 bar의 형태로 제작하여 8채널 head 코일의 element에 부착한 후, 실리콘 부착 전 후 water phantom의 신호강도를 측정하였다. 영상획득은 3.0T 초전도 자기공명영상장치와 8채널 head 코일을 이용하여 T1, T2강조영상을 획득하였으며, 획득한 영상은 영상측정프로그램을 이용하여 신호강도를 측정한 후, 대응표본T검정을 이용하여 유의한 차이가 있는지 판단하였다. 부착 전 후 신호강도는 T1 강조영상은 3.39%, T2 강조영상은 2.62% 유의하게 증가하였다. 결론적으로 간접 부착방식은 증가율이 낮아 모든 환자를 대상으로 대체하기에는 한계가 있을 수 있지만, filling factor의 증가로 인한 신호강도의 의미있는 상승이 있으므로 당뇨병 등 감염성 질한 우려 환자에 적용 시 유용하리라 판단된다.

아몰퍼스 와이어의 ECT probe 적용에 대한 검토 (Application of Amorphous wire to ECT(Eddy Current Testing) Probe)

  • 김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2002
  • ECT(eddy currentign testing) is very effective technique to detect a flaw within a conductor. Co-based amorphous wire was used as a sensor head. The wire has almost 0 magneto-striction and high permeability. An uniform magnetic field was applied to 1mm thick copper plate and $25{\mu}m$ thick aluminum sheet conductor using spiral typed coil The size of the coil has $40mm{\times}40mm$ outer width and $8mm{\times}8mm$ inner width. The copper plate and aluminum sheet has 0.5mm and 0.1mm wide gap, respectively. The frequency range of applied field was 100kHz-600kHz. The induced voltage difference of 2.5mV was obtained in the maximum voltage and minimum one measured across the gap of the 1mm thick conductor. In the case of aluminum sheet, 0.4mV was obtained. From this results, the effectiveness of Co-based amorphous wire was confirmed in the ECT technique.

  • PDF

3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가 (Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.