• 제목/요약/키워드: Head coil

검색결과 124건 처리시간 0.088초

Experimental study of open head coil in vertical field MRI (수직자계 MRI용 개방형 머리영상 코일에 대한 실험적 연구)

  • Yi, J.H.;Kang, D.H.;Kim, J.H.;Yi, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.108-110
    • /
    • 1996
  • Open MRI is a new concept in clinical application of the MRI such as interventional study. Receiving RF coils used in the open MRI must have open structures to insure convenient manipulations fur the patient. In this paper, we presented experimental study fur open head coil suitable to 0.3 Tesla vertical field MRI system with its experimental results.

  • PDF

A Study on Transcranial Magnetic Electrode Simulation Using Maxwell 3D (Maxwell 3D를 이용한 경두개 자기 전극 시뮬레이션에 관한 연구)

  • Lee, Geun-Yong;Yoon, Se-Jin;Jeong, Jin-hyoung;Kim, Jun-Tae;Lee, Sang-sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제12권6호
    • /
    • pp.657-665
    • /
    • 2019
  • In this study, we conducted a study on the transcranial magnetic electrode, a method for the study of dementia and muscle pain, a neurodegenerative disease caused by an aging society, which is becoming a problem worldwide. In particular, transcranial magnetic electrodes have been studied to improve their ability to be deteriorated by dementia symptoms such as speech, cognitive ability, and memory by outputting magnetism deep into the brain using coils on the head epidermis. In this study, simulation was performed using Maxwell 3D program for the design of coil, the core of transcranial magnetic electrode. As a result of the simulation comparison between the coil designed by the previous research and the coil through the research and development, the output was found to be superior to the conventional designed coil. The graphs of the coil outputs of B-Field and H-Field are found to be symmetrical, but the symmetry between each coil is pseudo-symmetrical and not accurate. Based on these results, an experiment was conducted to confirm whether the output of the head epidermis through both coils is possible. In the magnitude field of the reverse-coil 2-coil analysis, the maximum output was 3.3920e + 004 H [A_per_meter], and the vector field showed the strongest magnetic field around 35 to 165 degrees. It was confirmed that the magnetic output canceled due to the magnetic output. In the case of the forward 2-coil, a maximum of 3.2348e + 004H [A_per_meter] similar to the reverse coil was observed, but in the case of the vector field, the magnetic output regarding the forward output and the head skin output was confirmed. However, when the height change in the output coil, the magnetic output was reduced.

The Development of Acupuncture- Moxibustion Device for 4 points around GV20(Baihui) (백회와 사신총 혈위에 적합한 침구 소자의 개발)

  • Jo, Bongkwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • 제19권2호
    • /
    • pp.101-108
    • /
    • 2015
  • Objectives This paper focused on developing the acupuncture-moxibustion device for head. Disadvantages of the existing devices for head moxibustion are its hume and inconvenience in operating because of the hair. Methods The proposed acupuncture-moxibustion device for GV20(Baihui) is 10mm long as needle body and 6mm long as needle root whose feature are 1~2 turns spiral coil. The spiral coil contains the moxa in order not to drop the moxa while operating Results The direct temperature on the burning moxa were measured by TK-305 infrared thermometer. But the direct temperature on the needle of acupuncture-moxibustion device were not able to measure by TK-305 infrared thermometer. By definition equation, the indirect temperatures on the needle of acupuncture-moxibustion device were able to be calculated. Conclusion A very safe, small and cheap acupuncture-moxibustion device for GV20(Baihui) of head is proposed. It will be useful to generate the heat shock protein and to operate in preventing and curing the Alzheimer's disease.

Time-Multiplexed RF Transmission to Improve $B_1$ Homogeneity in High Field MRI

  • Han, Byung-Hee;Seo, Jeung-Hun;Heo, Hye-Young;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • 제29권2호
    • /
    • pp.99-106
    • /
    • 2008
  • To improve $B_1$ homogeneity in high field MRI, the RF power is applied to the transmit array coil elements sequentially in the time-multiplexed way. Since only a single coil element is activated in a time-multiplexing slot, the global standing wave formation in the human body is greatly suppressed. The time-multiplexing slot width is on the order of micro seconds, hence, high-order-harmonic slices can be placed far from the transmit coil and simultaneous multiple slice selection can be avoided. The $B_1$ homogeneities of a birdcage coil and an eight-channel transmit array coil have been compared through finite difference time domain simulations. The simulation results indicate that the proposed technique can reduce the peak-to-peak $B_1$ inhomogeneity down to one fourth of the transmission with a birdcage coil on the central plane of the human head model at 3 T. The mimicking experiments at 3 T, eight separate experiments with a single coil element activated and image reconstruction by combining the eight images, also show promising results. It is expected that the proposed technique has some advantages over other $B_1$ improving methods in real practice since simple RF switching circuitries are only necessary and electromagnetic coupling between the coil elements is out of concern in its realization.

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제18권1호
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF

Development of a Crop Drop Detection System for Heated Rolling Process of Steel Mill (열간압연 공정을 위한 철편(鐵片)검출 시스템 개발)

  • Kim, Jong-Chul;Kwon, Tai-Gil;Han, Min-Hong
    • IE interfaces
    • /
    • 제16권2호
    • /
    • pp.248-257
    • /
    • 2003
  • In a heated rolling process of a steel mill where steel plates are pressed to a sheet coil by spreading and expanding, an irregularly-shaped head portion as well as a tail portion of the sheet coil need to be cropped. Any crop which is not clearly cut and separated from the sheet coil may cause critical damages to the facilities of the following processes. As the cropping process is performed very fast, human eyes are not proper for continuous monitoring of the cropping process. To solve this problem, we have developed a machine-vision based crop-drop detection system. The system also measures lengths of major and minor axes for the crops and thereby determines the proper crop size to minimize steel sheet losses.

Development of TEM Head-Size Resonator for 3T MRI Head Coil

  • Ha, Seung-Hoon;Choe, Bo-Young;Lee, Hyoung-Koo-;Suh, Tae-Suk;Shinn, Kyung-Sub;Kim, Yong-Sik;Lee, Heung-Kyu
    • Proceedings of the Korean Magnetic Resonance Society Conference
    • /
    • 한국자기공명학회 2000년도 동계총회 및 제16회 자기공명 학술발표회
    • /
    • pp.35-37
    • /
    • 2000
  • PDF

OBSERVATION OF THE MAGNETIC DOMAIN IN THIN-FILM HEADS BY ELECTRON MICROSCOPY

  • Kobayashi, Kazuo
    • Journal of the Korean Magnetics Society
    • /
    • 제5권5호
    • /
    • pp.710-715
    • /
    • 1995
  • Magnetic domains were observed using an image lock-in technique for backscattered electron contrast (Type II) with a 200 kV scanning electron microscope. Backscattered electrons indicate a difference in magnetic domain structures at the upper and lower parts of the upper pole in thin-film heads, changing the acceleration voltage. With this method, it is also possible to observe the domain structure of the thin-film head pole through a 10 to $20\;\mu\textrm{m}$ protective layer, and the upper shield of the MR head through the coil in the resist, alumina overcoat, and upper pole.

  • PDF

Effect of GABA Antagonist in the Monocular Optokinetic Nystagmus of the Chicken (닭의 Monocular Optokinetic Nystagmus에서 GABA Antagonist 효과)

  • 김명순
    • The Korean Journal of Zoology
    • /
    • 제33권3호
    • /
    • pp.247-254
    • /
    • 1990
  • Chicken monocular head and eye optokinetic nystagmus (OKN) were observed by coil recordings after intravitreal administration of GABA antagonists (picrotoxin and bicuculline) into the opened and closed eye. Before injection of drugs the chicken displayed an OKN for T-N stimulation being more efficient in evoking this visuomotor reflex than for N-T stimulation. The injection of GABA antagonist into the opened eye provoked a decrease or disappearance of the head and eye OKN. On the other hand, the injection of GABA antagonist into the closed eye, the head and eye OKN augmented. Thus, GABA antagonist abolished the directional asymmetry of the head and eye OKN, indicating the involvement of GABAergic mechanisms in the inhibition of the N-T component of the monocular OKN.

  • PDF