• Title/Summary/Keyword: Head and neck radiotherapy

Search Result 390, Processing Time 0.037 seconds

Using Implementation Science to Advance Cancer Prevention in India

  • Krishnan, Suneeta;Sivaram, Sudha;Anderson, Benjamin O.;Basu, Partha;Belinson, Jerome L;Bhatla, Neerja;D' Cruz, Anil;Dhillon, Preet K.;Gupta, Prakash C.;Joshi, Niranjan;Jhulka, PK;Kailash, Uma;Kapambwe, Sharon;Katoch, Vishwa Mohan;Kaur, Prabhdeep;Kaur, Tanvir;Mathur, Prashant;Prakash, Anshu;Sankaranarayanan, R;Selvam, Jerard M;Seth, Tulika;Shah, Keerti V;Shastri, Surendra;Siddiqi, Maqsood;Srivastava, Anurag;Trimble, Edward;Rajaraman, Preetha;Mehrotra, Ravi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3639-3644
    • /
    • 2015
  • Oral, cervical and breast cancers, which are either preventable and/or amenable to early detection and treatment, are the leading causes of cancer-related morbidity and mortality in India. In this paper, we describe implementation science research priorities to catalyze the prevention and control of these cancers in India. Research priorities were organized using a framework based on the implementation science literature and the World Health Organization's definition of health systems. They addressed both community-level as well as health systems-level issues. Community-level or "pull" priorities included the need to identify effective strategies to raise public awareness and understanding of cancer prevention, monitor knowledge levels, and address fear and stigma. Health systems-level or "push" and "infrastructure" priorities included dissemination of evidence-based practices, testing of point-of-care technologies for screening and diagnosis, identification of appropriate service delivery and financing models, and assessment of strategies to enhance the health workforce. Given the extent of available evidence, it is critical that cancer prevention and treatment efforts in India are accelerated. Implementation science research can generate critical insights and evidence to inform this acceleration.

A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy (두경부 방사선 치료 시 입체조형동적회전조사치료와 용적변조회전조사치료에 관한 연구)

  • Kim, Deok-Ki;Choi, CheonWoong;Choi, Jae-hyock;Won, Hui-su;Park, Cheol-soo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.208-218
    • /
    • 2015
  • Recently, radiation therapy is used in the CT existing conventional two-dimensional radiation image, and set the size and location of the tumor in a manner that the image is going to change the treatment plan. After using the simulation using CT, radiation therapy it is four-dimensional or three-dimensional treatment made possible. and radiation therapy became the more effective ever before. High technology radiation therapy such as the treatment of SRS,IMRT, IGRT, SBRT, is a need to try contemplating the possibility to apply appropriate analysis and situation, so it has its own characteristics. and then it is believed that it is necessary to analyze and try it worries the proper applicability of the situation. The configuration of the various treatment that is applicable in many hospitals is necessary to try to determine how to practically apply the patients. Critical organs surrounding tumor give a small dose to avoid side effects and then the tumor has the therapeutic effect by providing a larger dose than before the radiation treatment.

Quantitative Analysis of Voice Quality after Radiation Therapy for Stage T1a Glottic Carcinoma (T1a 병기 성문암의 방사선 치료 후 음성에 관한 연구)

  • Lee Joon-Kyoo;Chung Woong-Gi
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • Purpose : To evaluate the voices of irradiated patients with early glottic carcinoma and to compare these with the voices of healthy volunteers. Materials and Methods : The voice samples (sustained vowel) of seventeen male patients who had been irradiated for T1a glottic squamous carcinoma at least 1 year prior to the study were analyzed with objective voice analyzer (acoustic voice analysis, aerodynamic test, and videostroboscopic analysis) and compared with those of a normal group of twenty age- and sex-matched volunteers. Average fundamental frequency, jitter, shimmer, and noise-to-harmonic ratio were obtained for acoustic voice analysis. Maximal phonation time, mean flow rate, intensity, subglottic pressure, glottal resistance, glottal efficiency, and glottal power were obtained for aerodynamic test. Results : The irradiated group presented higher values of shimmer in acoustic voice analysis. There was no significant difference between two groups in other parameters. Conclusion : In this study all the objective voice parameters except shimmer were no4 significantly different between the irradiated group and the control group. These results suggest that the voice quality is minimally affected by radiation therapy for 71 a glottic carcinoma.

The Application of Chamfer Matching Algorithm to the Error Analysis of a Treatment Field between a Simulation Image and a Portal Image (챔퍼 매칭(Chamfer Matching) 알고리즘을 활용한 모의치료 영상과 포탈(Portal) 영상의 비교, 분석)

  • 송주영;나병식;정웅기;안성자;남택근;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.189-195
    • /
    • 2003
  • The comparative analysis of a portal image and a simulation image is a very important process in radiotherapy for verifying the accuracy of an actual treatment field. In this study, we applied a chamfer-matching algorithm to compare a portal image with a simulation image and verified the accuracy of the algorithm to analyze the field matching error in the portal image. We also developed an analysis program that could analyze the two images more effectively with a chamfer-matching method and demonstrated its efficacy through a feasibility study. With virtual portal images, the accuracy of the analysis algorithm were acceptable considering the average error of shift (0.64 mm), rotation (0.32$^{\circ}$), and scale (1.61%). When the portal images of a head and neck phantom were analyzed, the accuracy and suitability of the developed analysis program was proven considering the acceptable average error of shift (1.55 mm), rotation (0.80$^{\circ}$), and scale (1.72%). We verified the applicability of a chamfer-matching algorithm to the comparative analysis of a portal image with a simulation image. The analysis program developed in this study was a practical tool to calculate the quantitative error of the treatment field in a portal image.

  • PDF

A Study of Relationship Between PPC (Probability of Primary Clearance: a multivariate modelling system predicting tumor clearance proposed by RTOG) and Survival in the Patients with Carcinoma of the Nasopharynx following Radiation Therapy (비인강암의 방사선치료 : RTOG에서 제시한 PPC와 생존율에 대한 고찰)

  • Cho Kwan Ho;Park Kyung Ran;Oh Won Yong;Chun Mison;Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 1986
  • RTOG proposed a multivariate modelling system predicting the response of head and neck cancers to radiation therapy in 1984. The aim of this study was to veri(y whether PPC (Probaility of primary clearance calculated by a multivariate modelling system) had any correlation with the survival in the patients with carcinoma of the nasopharynx following radiation therapy Analysing 81 patients with carcinoma of the nasopharynx treated with radiotherapy between January 1, 1971 and December 31, 1983 at Yonsei University College of Medicine, Yonsei Cancer Center the actuarial 5 year survival rate was $36\%$ and median survival was 39 months. The survivals for Group 1 (27 who had more than $80\%$ of PPC), Group 2 (20 who had between 71 and $80\%$ of PPC), and Group 3 (29 who had less than $71\%$ of PPC) were $66\%$ (median survival months : more than 72), $27\%$ (31), and $4\%$ (12) respectively. There was a definite correlation between PPC and survival among the three groups.

  • PDF

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.

The Effects of Diltiazem and Pentoxifylline on Apoptosis of Irradiated Rat Salivary Gland (흰쥐 침샘의 방사선조사시 Apoptosis에 대한 Diltiazem과 Pentoxifylline의 효과)

  • Yang, Kwang-Mo;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.367-375
    • /
    • 1998
  • Purpose : Xerostomia is a complication met by almost all patients who have radiotherapy for cancers of head and neck. Many studies for prevention of xerostomia will be necessary. Radiation-induced acute response of salivary glands has been defined as interphase death or apoptosis. Increased intracellular calcium level have an important role in radiation-induced apoptosis. Calcium channel blocker may prevent radiation-induced apoptosis of salivary glands. This study was designed to evaluate the effectiveness of diltiazem known as calcium channel blocker and pentoxifylline with inhibition of inflammatory response on the apoptosis as an acute response of radiation in rat salivary glands. Materials and Methods : Sprague-Dawley rats with about body weight 200-250 g were divided into 5 study groups : control, radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation. The diltiazen and pentoxifylline were injected intraperitoneally 20 mg/kg and 50 mg/kg, 30 and 20 mimute before irradiation. respectively. Irradiation was given with a 4 MV linear accelerator. The 1600 cGy of radiation was delivered in a single fraction through a single anterior portal encompassing the entire neck. After 24 h of irradiation, rats were sacrificed and parotid and submandibular glands were removed and stained with hematoxylin and eosin. The quantification of apoptosis was performed by microscopic examination of stained tissue sections at a magnification of 200X and the percentage of apoptotic cell was calculated. Results : On parotid glands, the percentage of apoptosis by radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.72$\%$ (8.35/486), 0.64$\%$ (2.9/453), 0.23$\%$ (1.2/516), and 0.28$\%$ (1.1/399), respectively. The apoptosis was markedly reduced in the groups receiving drugs compared with groups receivinge, radiation alone (p<0.05). In serous cell of submandibular glands, the percentages of apoptosis of radiation alone, diltiazem with radiation, pentoxifylline with radiation, and diltiazem and pentoxifylline with radiation were 1.94$\%$ (l1/567), 0.34$\%$ (1.9/554), 0.28$\%$ (1.8/637), and 0.22$\%$ (1.3/601), respectively. In the mucus cell of submandibular glands, the percentages of apoptosis were 0.92$\%$ (5.1/552), 0.41$\%$ (2.5/612), 0.29$\%$ (1.3/455), and 0.18$\%$ (1.0/562), respectively. The apoptosis was markedly reduced in the serous glands (p<0.05), but there was no difference in development of apoptosis in each group of mucus gland. Conclusion : These results suggest that radiation-induced apoptosis of serous cells of salivary glands may be decreased by diltiazem and pentoxifylline administration.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

The Effect of Aquaplast on Surface Dose of Photon Beam (Aquaplast가 광자선의 표면선량에 미치는 영향)

  • Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.95-100
    • /
    • 1995
  • Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy Materials and Methods: To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in $25{\times}25{\times}3cm^3$ acrylic phantom and set on $25{\times}25{\times}5cm^3$ polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 100cm SSD for $5{\times}5cm^2$, $10{\times}10cm^2$ and $15{\times}15cm^2$ field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types of Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and Khan to correct overresponse of the Markus chamber. Results : The surface doses for open fields of $5{\times}5cm^2$, $10{\times}10cm^2$, and $15{\times}15cm^2$ were $79\%$, $13.6\%$, and $18.7\%$, respectively. The original Aquaplast increased the surface doses upto $38.4\%$, $43.6\%$, and $47.4\%$, respectively. For transformed Aquaplast, they were $31.2\%$, $36.1\%$, and $40.5\%$, respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by $0.2\%$, $1.7\%$, $3.0\%$ without Aquaplast, $0.2\%$, $1.9\%$, $3.7\%$ with transformed Aquaplast, respectively. Conclusion: The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax, however, were not affected by Aquaplast. In conclusion, although the use of Aquaplast in practice may cause some increase of skin and buildup region dose, reductioin of skin-sparing effect will not be so significant clinically.

  • PDF