• Title/Summary/Keyword: Head and Neck cancer

Search Result 1,141, Processing Time 0.035 seconds

Investigation of aerodynamic evaluation in female patients undergoing thyroidectomy (갑상선절제술을 받은 여성 환자의 공기역학 검사변수 조사)

  • Kang, Young Ae;Kwon, In Sun;Won, Ho-Ryun;Chang, Jae Won;Koo, Bon Seok
    • Phonetics and Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.73-80
    • /
    • 2020
  • Breathing is the voice's driving force and also acts as a regulator of larynx function and efficiency. Respiratory distress is a side effect of general anesthesia in thyroid surgery. Therefore, this study's objective was to provide practical and complementary information for voice recovery after thyroid surgery, based on aerodynamic evaluation pre- and post-thyroidectomy. From May 2014 to July 2015, aerodynamic evaluations were performed on 34 female patients diagnosed with thyroid papillary cancer one week before surgery (PRE), one month after surgery (P1), and three months after surgery (P3). The Phonatory Aerodynamic System (model 6600, KayPENTAX, USA) was employed for this purpose, and a total of 29 analysis parameters were selected. The results showed statistically significant differences in peak expiratory airflow (p=0.004), mean pitch (p<0.01), expiration airflow duration (p=0.001), and expiratory volume (p=0.018), based on time factors. In the comparison of time factors, peak expiratory airflow and mean pitch parameters were different in PRE-P1 and PRE-P3. Expiration airflow duration and expiratory volume parameters were different in PRE-P3 and P1-P3. The interaction effect of time and surgical range was significant only for expiratory volume (p=0.024). Female patients who undergo thyroidectomy require post-operative breathing training, and exhalation improvement is considered to reflect a positive lifestyle after surgery.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

The Change of Tumor Interstitial Fluid Pressure by Radiation Therapy in Patients with Metastatic Lymph Node in Head and Neck Area (방사선치료시 두경부 림파절 종양내 간질액 압력의 변화 양상)

  • Cho Moon-June;Kim Jae-Sung;Lee Intae;Kim Jun-Sang;Kim Ki-Hwan;Jang Ji-Young
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.127-132
    • /
    • 2000
  • Purpose : To determine if the tumor intersitial fluid pressure (TIFP) and/or its change in patients with metastatic Iymph node in head and neck area can predict radiotherapy outcome. Materials and Methods : In 26 biopsy Proven metastatic Iymph node Patients in head and neck area with accessible by direct inspection and palpation, and of sufficient thickness (>1 cm) to permit accurate needle placement, we measured TIFP at cervical Iymph node before and during radiotherapy. Tumor size was measured clinically and radiologically. Results : The mean preradiotherapy TIFP was 24.7 mmHg. Preradiotherapy TIFP had marginally significant relationship with tumor size (p=0.06). Preradiotherapy TIFP significantly decreased when tumor size decreased (p=0.009). Preradiotherapy TIFP was not different between complete response group and group with partial or less response (p=0.75). Radiotherapy outcome was not different between group with above and group with below than average TIFP (p=0.229). TIFP decreased 36mmHg in complete response group and 29.7 mmHg in group with partial or less response. Conclusion :The mean TIFP was elevated with 24.7 mmHg. Preradiotherapy TIFP had marginally significant relationship with tumor size (p=0.06). TIFP decreased 36 mmHg in complete response group and 29.7 mmHg in group with partial or less respone but there was no statistically significant relationship in two groups.

  • PDF

Combined Chemotherapy and Radiotherapy versus Radiotherapy alone in the Management of Localized Angiocentric Lymphoma of the Head and Neck (국한성 두경부 혈관 중심위 림프종에서 화학방사선 병용치료법과 방사선치료 단독요법의 비교)

  • Chang Sei Kyung;Kim Gwi Eon;Lee Sang-Wook;Park Hee Chul;Pyo Hong Ryull;Kim Joo Hang;Moon Sun Rock;Lee Hyeong Sik;Choi Eun Chang;Kim Kwang Moon
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2002
  • Purpose : To clarify the clinical benefit derived from the combined modality therapy (CMT) consisting of chemotherapy (CT) and involved field radiotherapy (RT) for stage I and II angiocentric lymphomas of the head and neck. Materials and Methods : Of 143 patients with angiocentric lymphoma of the head and neck treated at our hospital between 1976 and 1995, 104 patients (RT group) received involved field RT alone with a median dose of 50.4 Gy (range : 20~70 Gy), while 39 patients (CMT group) received a median 3 cycles (range : 1~6 cycles) of CT before involved field RT. The response rate, patterns of failure, complications, and survival data of the RT group were compared with those of the CMT group. Results : Despite a higher response rate, local failure was the most common pattern of failure in patients of both groups. The patterns of failure, including the systemic relapse rate were not influenced by the addition of combination CT. Although both modalities were well tolerated by the majority of patients, aberrant immunologic disorders or medical illnesses, such as a hemophagocytic syndrome, sepsis, intractable hemorrhage, or the evolution of second primary malignancies were more frequently observed in patients of the CMT group. The prognosis of patients in the RT group was relatively poor, with a 5-year overall actuarial survival rate of 38% and disease-free survival rate of 32%, respectively. However, their clinical outcome was not altered by the addition of systemic CT. Achieving complete remission was the most important prognostic factor by univariate and multivariate analyses, but treatment modality was not found to be a prognostic variable influencing survival. Conclusions : Involved field RT alone for angiocentric lymphoma of the head and neck was insufficient to achieve an improved survival rate, but the addition of CT to involved field RT failed to demonstrate any therapeutic advantage over involved field RT alone.

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Synthesis of $[^{51}Cr]Cr(III)$-EDTA Complex and Measurement of Glomerular Filtration Rate br Radioactivity Counting of Head and Neck Region ($[^{51}Cr]Cr(III)$-EDTA 착물 합성 및 $[^{51}Cr]Cr(III)$-EDTA 주사후 두경부 방사능 계측에 의한 사구체 여과율 측정)

  • Yang, Seung-Dae;Lim, Sang-Moo;Chun, Kwon-Soo;Suh, Yong-Sup;Yoon, Yong-Ki;Park, Hyun;Woo, Kwang-Sun;Chung, Wi-Sup;Oh, Ok-Doo;Lee, Jung-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.364-370
    • /
    • 1994
  • The purpose of this study is to evaluate the clinical application of the no carrier added $[^{51}Cr]Cr(III)$-EDTA complexes, produced at Korea Cancer Center Hospital. The $[^{51}Cr]Cr(III)$-EDTA complexes, usefut for measurement of GFR were prepared at room temperature in the presence of bicarbonate catalysts. The radiochemical purity of $[^{51}Cr]Cr(III)$-EDTA was over 99% by paper electrophoresis. The time activity curves were obtained by counting the blood samples from 5 volunteers and counting the head and neck regions with whole body counter after injection of the $^{51}Cr$-EDTA, respectively. After the nonlinear regression, the area under curve was obtained. The plasma clearance of the $^{51}Cr$-EDTA was calculated with injected dose/AUC. The clearance rate calculated with the head and neck counting data was in good agreement with the result from the plasma sample radioactivity at 1-3 hrs after injection. From this result, the counting of head and neck region and the nonlinear regression by 2-compartment model could be applied for the measurement of the clearance rate. Using MIRD system, the absorbed radiation dose was calculated by residence $time{\times}S$. The absorbed whole body radiation dose was negligibly small.

  • PDF

The Effects of Neck Irradiation on Thyroid Gland for Tumors of the Head and Neck -A prospective analysis of 75 cases- (두경부종양 환자에서 경부 방사선조사가 갑상선기능에 미치는 영향 -75예의 전향적 분석-)

  • Park In Kyu;Kim Sang Bo;Yun Sang Mo;Park Jun Sik;Jun Su Han;Kim Bo Wan
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.59-66
    • /
    • 1994
  • Seventy-five patients with tumors of the head and neck treated with either radiation therapy alone or combined with surgery or chemotherapy were studied prospectively to evaluate the effects of radiation therapy to the neck on thyroid gland between September 1986 and October 1992. All patients were serially monitored for thyroid function tests before and after radiation therapy. Radiation dose to the thyroid gland ranged from 35 to 60 Gy with a median dose of 50 Gy. Median follow-up time was 30 months with a range of 11 to 85 months. The incidence of thyroid dysfunction was 40$ \% $: forty-five patients(60$ \% $) euthyroid, 2 patients(3$ \% $) clinical hypothyroidism, 27 patients(36$ \% $) subclinical hypothyroidism and 1 patient(1$ \% $) hyperthyroidism. No thyroid nodules or thyroid cancer were detected in any patients. Thyroid dysfunction appeared earlier in patients who underwent surgery than in those patients treated with radiation therapy alone or combination of chemotherapy and radiation therapy(P=0.0013). By multivariate analysis, risk factors that significantly influenced a higher incidence of thyroid dysfunction were female sex(p=0.0293) and combination of total laryngectomy and radiation therapy(p : 0.0045). In conclusion, evaluation of thyroid function before and after radiation therapy with periodic thyroid function tests are recommended to detect thyroid dysfunction in time and thyroid hormone replacement therapy is recommended whenever thyroid dysfunction develops.

  • PDF

Incidental Abnormal FDG Uptake in the Prostate on 18-fluoro-2-Deoxyglucose Positron Emission Tomography-Computed Tomography Scans

  • Kang, Pil Moon;Seo, Won Ik;Lee, Sun Seong;Bae, Sang Kyun;Kwak, Ho Sup;Min, Kweonsik;Kim, Wansuk;Kang, Dong Il
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8699-8703
    • /
    • 2014
  • 18-fluoro-2-deoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET/CT) scans are commonly used for the staging and restaging of various malignancies, such as head and neck, breast, colorectal and gynecological cancers. However, the value of FDG PET/CT for detecting prostate cancer is unknown. The aim of this study was to evaluate the clinical value of incidental prostate $^{18}F$-FDG uptake on PET/CT scans. We reviewed $^{18}F$-FDG PET/CT scan reports from September 2009 to September 2013, and selected cases that reported focal/diffuse FDG uptake in the prostate. We analyzed the correlation between $^{18}F$-FDG PET/CT scan findings and data collected during evaluations such as serum prostate-specific antigen (PSA) levels, digital rectal examination (DRE), transrectal ultrasound (TRUS), and/or biopsy to confirm prostate cancer. Of a total of 18,393 cases, 106 (0.6%) exhibited abnormal hypermetabolism in the prostate. Additional evaluations were performed in 66 patients. Serum PSA levels were not significantly correlated with maximum standardized uptake values (SUVmax) in all patients (rho 0.483, p=0.132). Prostate biopsies were performed in 15 patients, and prostate cancer was confirmed in 11. The median serum PSA level was 4.8 (0.55-7.06) ng/mL and 127.4 (1.06-495) ng/mL in the benign and prostate cancer groups, respectively. The median SUVmax was higher in the prostate cancer group (mean 10.1, range 3.8-24.5) than in the benign group (mean 4.3, range 3.1-8.8), but the difference was not statistically significant (p=0.078). There was no significant correlation between SUVmax and serum PSA, prostatic volume, or Gleason score. $^{18}F$-FDG PET/CT scans did not reliably differentiate malignant or benign from abnormal uptake lesions in the prostate, and routine prostate biopsy was not usually recommended in patients with abnormal FDG uptake. Nevertheless, patients with incidental prostate uptake on $^{18}F$-FDG PET/CT scans should not be ignored and should be undergo further clinical evaluations, such as PSA and DRE.

A Study of Relationship Between PPC (Probability of Primary Clearance: a multivariate modelling system predicting tumor clearance proposed by RTOG) and Survival in the Patients with Carcinoma of the Nasopharynx following Radiation Therapy (비인강암의 방사선치료 : RTOG에서 제시한 PPC와 생존율에 대한 고찰)

  • Cho Kwan Ho;Park Kyung Ran;Oh Won Yong;Chun Mison;Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 1986
  • RTOG proposed a multivariate modelling system predicting the response of head and neck cancers to radiation therapy in 1984. The aim of this study was to veri(y whether PPC (Probaility of primary clearance calculated by a multivariate modelling system) had any correlation with the survival in the patients with carcinoma of the nasopharynx following radiation therapy Analysing 81 patients with carcinoma of the nasopharynx treated with radiotherapy between January 1, 1971 and December 31, 1983 at Yonsei University College of Medicine, Yonsei Cancer Center the actuarial 5 year survival rate was $36\%$ and median survival was 39 months. The survivals for Group 1 (27 who had more than $80\%$ of PPC), Group 2 (20 who had between 71 and $80\%$ of PPC), and Group 3 (29 who had less than $71\%$ of PPC) were $66\%$ (median survival months : more than 72), $27\%$ (31), and $4\%$ (12) respectively. There was a definite correlation between PPC and survival among the three groups.

  • PDF

A Pilot Study for the Remote Monitoring of IMRT Using a Head and Neck Phantom (원격 품질 보증 시스템을 사용한 세기변조 방사선치료의 예비 모니터링 결과)

  • Han, Young-Yih;Shin, Eun-Hyuk;Lim, Chun-Il;Kang, Se-Kwon;Park, Sung-Ho;Lah, Jeong-Eun;Suh, Tae-Suk;Yoon, Myong-Geun;Lee, Se-Byeong;Ju, Sang-Gyu;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.249-260
    • /
    • 2007
  • Purpose: In order to enhance the quality of IMRT as employed in Korea, we developed a remote monitoring system. The feasibility of the system was evaluated by conducting a pilot study. Materials and Methods: The remote monitoring system consisted of a head and neck phantom and a user manual. The phantom contains a target and three OARs (organs at risk) that can be detected on CT images. TLD capsules were inserted at the center of the target and at the OARs. Two film slits for GafchromicEBT film were located on the axial and saggital planes. The user manual contained an IMRT planning guide and instructions for IMRT planning and the delivery process. After the manual and phantom were sent to four institutions, IMRT was planed and delivered. Predicted doses were compared with measured doses. Dose distribution along the two straight lines that intersected at the center of the axial film was measured and compared with the profiles predicted by the plan. Results: The measurements at the target agreed with the predicted dose within a 3% deviation. Doses at the OARs that represented the thyroid glands showed larger deviations (minimum 3.3% and maximum 19.8%). The deviation at OARs that represented the spiral cord was $0.7{\sim}1.4%$. The percentage of dose distributions that showed more than a 5% of deviation on the lines was $7{\sim}27%$ and $7{\sim}14%$ along the horizontal and vertical lines, respectively. Conculsion: Remote monitoring of IMRT using the developed system was feasible. With remote monitoring, the deviation at the target is expected to be small while the deviation at the OARs can be very large. Therefore, a method that is able to investigate the cause of a large deviation needs to be developed. In addition, a more clinically relevant measure for the two-dimensional dose comparison and pass/fail criteria need to be further developed.