• Title/Summary/Keyword: Head Dimensions

Search Result 127, Processing Time 0.027 seconds

An Analysis of Stress Transfer Behaviors within the Necrotic Cancellous Bone following Surgical Procedures or the Management of the Osteonecrosis of the Femoral Head (대퇴골두 무혈성 괴사증의 수술적 기법 적용 후 괴사 망상골 내에서의 응력 변화 해석)

  • Kim, J.S.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.245-248
    • /
    • 1997
  • Operative interventions for the management of osteonecrosis of the femoral head (ONFH) include core drilling, with or without vascularized fibular bone grafting. Nevertheless, their clinical results have not been consistently satisfactory. Recently, a new surgical procedure that incorporates cementation with polymethylmethacrylate (PMMA) after core drilling has been tried clinically. In this study, a biomechanical analysis using a finite element method(FEM) was undertaken to evaluate surgical methods and their underlying surgical parameter. Our finite element models included five types. They were (1) normal model (Type I), (2) necrotic model (Type II), (3) core decompressed model (Type III). (4) fibular bone grafted model (Type IV), and (5) cemented with PMMA model (Type V). The geometric dimensions of the femur were based on digitized CT-scan data of a normal person. Various physiological loading conditions and surgical penetration depths by the core were used as mechanical variables to study their biomechanical contributions in stress transfer within the femoral head region. In addition. the peak von Mises stress(PVMS) within the necrotic cancellous bone of the femoral head was obtained. The fibular bone grafted method and cementation method provided optimal stress transfer behaviors. Here. substantial increase in the low stress level was observed when the penetration depth was extended to 0mm and 5mm from the subchondral region. Moreover, significant decrease in PVMS due to surgery was observed in the fibular bone grafted method and the cementation method when the penetration depths were extended up to 0 and 5mm from the subchondral region. The drop in PVMS was greater during toe-off than during heel-strike (57% vs. 28% in Type IV and 49% vs. 22% in Type V). Both the vascularized fibular bone grafting method (Type IV) and the new PMMA technique (Type V) appear to be very effective in providing good stress transfer and reducing the peak Von-Mises stress within the necrotic region. Overall results show that fibular bone grafting and cementation methods are quite similar. In light of above results, the new cementation method appears to be a promising surgical alternative or the treatment of ONFH. The use of PMMA for the core can be less prone to surgical complication as opposed to preparation of fibular bone graft and can achieve more immediate fixation between the core and the surrounding region.

  • PDF

Biodynamic Characteristics of Korean Male in Twenties-Mass, Center of Mass and Moment of Inertia Characteristics of Body Segments (한국인 20대 청년 인체분절의 관성특성에 관한 연구)

  • 이영신;임현균;김철중
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.1952-1966
    • /
    • 1994
  • The body segment parameters of twelve young male Korean were measured to compare with the results of foreign cadaver studies. A human body was assumed to have fourteen body segments. The mass of each segment was measured with a water immersion test and the mass center of a segment was determined on the balance platform by changing postures. In the case of Korean, because of the difference in body proportion, the mass center of whole-body is located further from the distal end of head(Korean : 44.9% vs. Caucasian : 41.2%), and the mass center of each segment also located in different proportional locations. The existing regression equations, which can estimate segment mass based upon the anthropometric dimensions, estimates segment mass (the mass of shank) for Korean with 13% error. Therefore, it is not recommended to estimate the mass, and the moment of inertia of body segment of Korean based on the existing equations. However, the density information of body constituents was similar enough to apply it to Korean density. It was validated by the comparison between the results of the direct immersion method and 3-dimensional volume reconstruction of segment form the cross sectional images of CT-scan. The average body density measured form twelve subjects was $1.035{\;}kg/m^3$ and showed deceasing trendency.

Mixed Reality System for Virtual Chemistry Lab

  • Duan, Xiaoyun;Kang, Shin-Jin;Choi, Jong In;Kim, Soo Kyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1673-1688
    • /
    • 2020
  • This paper presents a new method for improving teaching aids with the design and development of a chemistry education platform - the Mixed Reality (MR) Chemistry Lab. Our system provides a new educational experience in which students can simulate a chemistry experiment in a virtual lab and interact with objects using Oculus Helmet-Mounted Displays (HMD) and hand controller devices. The proposed system aims to familiarize students with experimental procedures and safety knowledge before conducting actual experiments. Moreover, students will be able to observe microscopic atomic structure models in three dimensions. Our research also includes a five-part, quantitative evaluation system user tests perform using a quantitative questionnaire consisting of five items, including hardware equipment, immersion, education, interaction sense of control, and degree of difficulty. The evaluation results confirm that this system will be helpful to the educational experience of conducting chemistry experiments with scientific evaluation methods, and the proposed system is also expected to have a broad range of applications in many other subjects.

Tightening Characteristics of domestic M8 stainless screws (국산 M8 스테인리스 나사의 체결특성)

  • 인상렬;박미영
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.155-163
    • /
    • 2001
  • A number of screws are inevitably used for tightening flanges in constructing a vacuum system. A theoretical relation between the axial force and the torque exerted on a screw is easily obtained assuming that the friction force generated on the contacting plane is known, however, in practice the friction is influenced strongly by unknown detailed surface condition. It is difficult to tighten optimally and uniformly the flange seals if the screws commercially available have undefined surface conditions and scattered dimensions, and the axial force produced by the screws can not be expected properly. In this paper a scatter of the axial force over screws and the deviation from an expected one, depending on various fastening conditions, are investigated using a variety of M8, the most popular size for vacuum flanges, domestic stainless screws of hexagonal head and standard thread.

  • PDF

A Numerical Study on Combustion-Stability Rating of Impinging-Jet Injector Using Air-Injection Technique (공기분사 기법을 이용한 충돌형 제트 분사기의 연소 안정성 평가에 관한 수치적 연구)

  • Sohn, Chae-Hoon;Park, I-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1093-1100
    • /
    • 2006
  • Combustion stability rating of jet injector is conducted numerically using air-injection technique in a model chamber, where air is supplied to oxidizer and fuel manifolds of the model five-element injector head. A sample F(fuel)-O(oxidizer)-O-F impinging-jet injector is adopted. In this technique, we can simulate mixing process of streams flowing through oxidizer and fuel orifices under cold-flow condition without chemical reaction. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions. From numerical data, unstable regions can be identified and they are compared with those from air-injection acoustic and hot-fire tests. The present stability boundaries are in a good agreement with experimental results. The proposed numerical method can be applied cost-effectively to stability rating of jet injectors when mixing of fuel and oxidizer jets is the dominant process in instability triggering.

The Importance of Nutritional Assessment and Dietary Counseling in Infants and Young Children with Common Illnesses (소아의 흔한 질병 상황에서 식이, 영양의 중요성)

  • Jeong, Su-Jin
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.14 no.1
    • /
    • pp.33-44
    • /
    • 2011
  • The influence of nutrition during early life on physical growth as well as mental development has been thoroughly discussed in the literature. The physical dimensions of the body are greatly influenced by nutrition, particularly during the period of rapid growth in early childhood. Nutritional status affects every pediatric patient's response toillness. Good nutrition is important for achieving normal growth and development. It is indicated that permanent impairment of the central nervous system may result from dietary restriction of imbalance during certain periods of life. If children under 3 years of age show a good nutritional status, it may be assumed that they are well nourished. Several common diseases of children such as iron deficiency, chronic constipation and atopic dermatitis are known food related diseases. Patients with chronic illness and those at risk of malnutrition should have detailed nutritional assessments done. Components of a complete nutritional assessment include a medical history, nutritional history including dietary intake, physical examination, anthropometrics (weight, length or stature, head circumference, midarm circumference, and triceps skinfold thickness), pubertal staging, skeletal maturity staging, and biochemical tests of nutritional status. The use of age, gender, and disease-specific growth charts is essential in assessing nutritional status and monitoring nutrition interventions. Nutrition assessment and dietary counseling is helpful for the cure of disease, and moreover, the prevention of illness.

Morphometric characteristics of diploid and triploid Far Eastern catfish, Silurus asotus

  • Park, In-Seok
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.106-113
    • /
    • 2020
  • This study identified the differences in the morphometric characteristics of the truss and classical dimensions between diploid and triploid Far Eastern catfish, Silurus asotus, and provided methods for sorting diploid and triploid Far Eastern catfish based on morphometric observations. The significant variables were the direct distance between the anterior edge of the lower lip and the anterior insertion of the dorsal fin(DALAD), the horizontal distance between the anterior edge of the lower lip and the anterior insertion of the ventral fin (HALAV), the direct distance between the anterior edge of the upper lip and the first nostril(DAUF), the direct distance between the anterior edge of the upper lip and the second nostril(DAUS), the interorbital width(IW), and the mandible barbel length (ManBL). The more significant variables were HALAV, DALAD, DAUF, IW, and DAUS. The most useful combination of variables for separating the two groups was DALAD, IW, and DAUF, which correctly classified 85% of the catfish as triploid or diploid, and that percentage was the maximum degree of value possible (p<0.05). Triploid Far Eastern catfish had a high rate of growth in the head region and body depth during the first year after hatching. Triploid Far Eastern catfish had smaller heads and shorter mandible barbels than diploid Far Eastern catfish.

Development of Cost-Effective Platform for Tracking and Analysis of Animal Ambulatory Patterns

  • Kwon, Jeonghoon;Park, Hong Ju;Joo, Segyeong;Huh, Soo-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.82-86
    • /
    • 2014
  • This paper reports the development of a platform for tracking and analysis of animal locomotion. The platform is composed of a commercial webcam, a metal stand for the webcam, and a plastic bathtub as a cage. Using it, researchers can track and analyze an animal's movement within the plastic bathtub's dimensions of $100cm{\times}100cm{\times}55cm$ in a cost-effective manner. After recording the locomotion of an animal with $1920{\times}1080$ resolution at a rate of 30 frames per second, finding the position of the animal in each frame and analyzing the ambulation pattern were executed with custom software. To evaluate the performance of the platform, movements of imprinting control region mice and transgenic mice were recorded and analyzed. The analysis successfully compared velocity, moving pattern, and total moving distance for the two mouse groups. In addition, the developed platform can be used not only in simple motion analysis but also in various experimental conditions, such as a water maze, by easy customization of the platform. Such a simple and cost-effective platform yields a powerful tool for animal ambulatory analysis.

Study on the Influence of Die Corner Radius for Deep Drawing of Elliptical Product of Automobile (자동차용 타원형 디프 드로잉 제품의 다이 반경에 관한 연구)

  • 허영민;박동환;강성수
    • Transactions of Materials Processing
    • /
    • v.11 no.8
    • /
    • pp.668-675
    • /
    • 2002
  • The circles deform into various shape during deformation, the major and minor axes of which indicate the direction of the major and minor principal strains. Likewise, the measured dimensions are used to determine the major and minor principal strain magnitudes. This circular grid technique of measuring strains can be used to diagnose the causes of necking and fracture in industrial practice and to investigate whether these defects were caused by material property variation, changes in lubrication, of incorrect press settings. In non-axisymmetric deep drawing, three modes of forming regimes are found: draw, stretch, plane strain. The stretch mode for non-axisymmetric deep drawing could be defined when the major and minor strains are positive. The draw mode could be defined when the major strain is positive and minor strain is negative, and plane strain mode could be defined when the major strain is positive and minor strain is zero. Through experiments the draw mode was shown on the wall and flange are one of a drawn cup, while the plane strain and the stretch mode were on the punch head and the punch corner area respectively, We observed that the punch load of elliptical deep drawing was decreased according to increase of die corner radius and the thickness deformation of minor side was more large than major side.

Fuzzy Distance Estimation for a Fish Robot

  • Shin, Daejung;Na, Seung-You;Kim, Jin-Young
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.4
    • /
    • pp.316-321
    • /
    • 2005
  • We designed and implemented fish robots for various purposes such as autonomous navigation, maneuverability control, posture balancing and improvement of quick turns in a tank of 120 X 120 X 180cm size. Typically, fish robots have 30-50 X 15-25 X 10-20cm dimensions; length, width and height, respectively. It is essential to have the ability of quick and smooth turning to avoid collision with obstacles or walls of the water pool at a close distance. Infrared distance sensors are used to detect obstacles, magneto-resistive sensors are used to read direction information, and a two-axis accelerometer is mounted to compensate output of direction sensors. Because of the swing action of its head due to the tail fin movement, the outputs of an infrared distance sensor contain a huge amount of noise around true distances. With the information from accelerometers and e-compass, much improved distance data can be obtained by fuzzy logic based estimation. Successful swimming and smooth turns without collision demonstrated the effectiveness of the distance estimation.