• Title/Summary/Keyword: Harvard University

Search Result 382, Processing Time 0.034 seconds

A Comparison of Alcohol Secondhand Effects among Korean and U.S. College Students (한국과 미국 대학생의 간접음주피해 비교)

  • Chun, Sung-Soo;Sohn, Ae-Ree;Reid, Easton A.;Inot, Rubelyn;Kim, Mi-Kyung;Percoheles, Grace;Lee, Sang-Sook;Wechsler, Henry
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.5
    • /
    • pp.115-127
    • /
    • 2009
  • Objectives: To compare alcohol secondhand effects among US and Korean students. Methods: Nationally representative 4-year colleges of two countries were involved in this cross-national comparison study. Data from the 2001 U.S. College Alcohol Study and the 2003 Korean College Alcohol Study came from 120 colleges in 38 U.S. states and the District of Columbia and 60 colleges in Korea. Randomly selected 4-year college students from the U.S. (10,924) and Korea (2,385) participated in the study using self-reports of alcohol use and perceptions of drinking as assessed by College Alcohol Study questionnaires. Results: Korean students were tend to more likely to have being a victim of sexual assault or date rape, having to take care of drunken students and finding vomit in the hall or bathroom of residence, than US students, while US students were tend to more likely to have being insulted or humiliated, having a serious argument and quarrel, being pushed, hit, or assaulted, having study/sleep interrupted, and experiencing an unwanted sexual advance than Korean students. Conclusion: In general, US students were more likely to suffer interrelationship problems after drinking while Korean students were more likely to have physical and individual drinking related problems.

The Background and Content of Thomas Jefferson's Plan for a Botanical Garden for the University of Virginia (토머스 제퍼슨의 버지니아대학교 식물원 구상 배경과 내용)

  • Kim, Jung-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.3
    • /
    • pp.49-59
    • /
    • 2019
  • This paper examines the background and content of Thomas Jefferson's botanical garden plan for the University of Virginia. When Jefferson promoted the establishment of a botanical garden, European botanical gardens were evolving from physic gardens, and American botanical gardens were in their infancy. Accordingly, this paper compares the Botanical Garden Plan for the University of Virginia with contemporary botanical gardens. This is examined by outlining the trends of botanical gardens in Europe and the United States around the nineteenth century, analyzing their function and spatial structure. Also, Jefferson's perspective on botany, his plan, and botanical gardens are reviewed. This study found that Jefferson's project had its background in the social recognition of the importance of botany as a practical science, advancing the national economy, which was a prominent goal in late eighteenth-century Europe, and in developing networks of exchanging plants and information concerning botany and botanical gardens. Based on the botanist Correia's opinion on the role of a public botanical garden, the Botanical Garden Plan for the University of Virginia was developed by Jefferson as an action plan, including its site creation, space organization, and supplying of plants. Compared to the other contemporary botanical gardens, the University of Virginia's Botanical Garden Plan has the following characteristics. First, like European gardens in the late eighteenth century, it evolved from being a physic garden to a botanical one. As such, it emphasized botanical research and education over medicine, creating a tree garden and a plant garden. Second, it differed from many European and American botanical gardens in that it rejected decorative elements, refused to install a greenhouse, and attempted to spread practical overseas plants suitable to the local climate. This study contributes to broadening the history of botanical gardens at the turn of the nineteenth century.

Treatment of Human Thyroid Carcinoma Cells with the G47delta Oncolytic Herpes Simplex Virus

  • Wang, Jia-Ni;Xu, Li-Hua;Zeng, Wei-Gen;Hu, Pan;Rabkin, Samuel D.;Liu, Ren-Rin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1241-1245
    • /
    • 2015
  • Background: Thyroid carcinoma is the most common malignancy of the endocrine organs. Although the majority of thyroid cancer patients experience positive outcomes, anaplastic thyroid carcinoma is considered one of the most aggressive malignancies. Current therapeutic regimens do not confer a significant survival benefit, and new therapies are urgently needed. Oncolytic herpes simplex virus (oHSV) may represent a promising therapy for cancer. In the present study, we investigated the therapeutic effects of a third-generation HSV vector, $G47{\Delta}$, on various human thyroid carcinoma cell lines in vitro. Two subcutaneous (s.c.) models of anaplastic thyroid carcinoma were also established to evaluate the in vivo anti-tumor efficacy of $G47{\Delta}$. Materials and Methods: The human thyroid carcinoma cell line ARO, FRO, WRO, and KAT-5, were infected with $G47{\Delta}$ at different multiplicities of infection (MOIs) in vitro. The survival rates of infected cells were calculated each day. Two s.c. tumor models were established using ARO and FRO cells in Balb/c nude mice, which were intratumorally (i.t.) treated with either $G47{\Delta}$ or mock. Tumor volumes and mouse survival times were documented. Results: $G47{\Delta}$ was highly cytotoxic to different types of thyroid carcinomas. For ARO, FRO, and KAT-5, greater than 30% and 80% of cells were killed at MOI=0.01 and MOI=0.1, respectively on day 5. WRO cells displayed modest sensitivity to $G47{\Delta}$, with only 21% and 38% of cells killed. In the s.c. tumor model, both of the anaplastic thyroid carcinoma cell lines (ARO and FRO) were highly sensitive to $G47{\Delta}$; $G47{\Delta}$ significantly inhibited tumor growth and prolonged the survival of mice bearing s.c. ARO and FRO tumors. Conclusions: The oHSV $G47{\Delta}$ can effectively kill different types of human thyroid carcinomas in vitro. $G47{\Delta}$ significantly inhibited growth of anaplastic thyroid carcinoma in vivo and prolonged animal survival. Therefore, $G47{\Delta}$ may hold great promise for thyroid cancer patients.

Study on Optimization of Detection System of Prompt Gamma Distribution for Proton Dose Verification (양성자 선량 분포 검증을 위한 즉발감마선 분포측정 장치 최적화 연구)

  • Lee, Han Rim;Min, Chul Hee;Park, Jong Hoon;Kim, Seong Hoon;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.162-168
    • /
    • 2012
  • In proton therapy, in vivo dose verification is one of the most important parts to fully utilize characteristics of proton dose distribution concentrating high dose with steep gradient and guarantee the patient safety. Currently, in order to image the proton dose distribution, a prompt gamma distribution detection system, which consists of an array of multiple CsI(Tl) scintillation detectors in the vertical direction, a collimator, and a multi-channel DAQ system is under development. In the present study, the optimal design of prompt gamma distribution detection system was studied by Monte Carlo simulations using the MCNPX code. For effective measurement of high-energy prompt gammas with enough imaging resolution, the dimensions of the CsI(Tl) scintillator was determined to be $6{\times}6{\times}50mm^3$. In order to maximize the detection efficiency for prompt gammas while minimizing the contribution of background gammas generated by neutron captures, the hole size and the length of the collimator were optimized as $6{\times}6mm^2$ and 150 mm, respectively. Finally, the performance of the detection system optimized in the present study was predicted by Monte Carlo simulations for a 150 MeV proton beam. Our result shows that the detection system in the optimal dimensions can effectively measure the 2D prompt gamma distribution and determine the beam range within 1 mm errors for 150 MeV proton beam.

THE PATIENTS' SATISFACTION FOLLOWING IMPLANT TREATMENT

  • Heo, Yoon-Young;Heo, Seong-Joo;Chang, Myung-Woo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.569-576
    • /
    • 2008
  • STATEMENT OF PROBLEM: While patient-centered outcomes are usually not reported, these may represent major aspects of the implant success for the patient. Use of a well-designed patient survey form can be an invaluable asset to the implant practitioners. PURPOSE: The objective of this study was to investigate patient satisfaction after implant therapy by means of a questionnaire. MATERIAL AND METHODS: South Korean patients (n = 100), who visited the dental examination center of Soon Chun Hyang university hospital, were asked to fill out the satisfaction questionnaire regarding aspects of cost, comfort, esthetics, chewing, gingival health, food impaction, phonetic aspect, screw loosening, and general satisfaction. Responses to statements were given on the Likert response scale. Four experimental groups of patients were distinguished with various location ($A_1,\;A_2,\;A_3$), year ($B_1,\;B_2,\;B_3$), number of implant replacements ($C_1,\;C_2,\;C_3$), and treatment cost ($D_1,\;D_2,\;D_3$). The reliability of the response scales was measured by calculation of its internal consistency, expressed as Cronbach's ${\alpha}$. The scales were distinguished by means of factor analysis method. Possible differences in scale scores among the groups were assessed by One-way ANOVA (${\alpha}$= 0.05). RESULTS: Patients responded to most of the statements with high satisfaction. But the mean scale score of statement about cost was low. After the verification of internal consistency and factor analysis, five components, e.g. general satisfaction, comfort, chewing efficiency, esthetics, and phonetic aspect were grouped together. These components could be explained with common meaning and the first factor was named as 'general satisfaction'. Differences in patient satisfaction on the scale with esthetics were present between patients who have been wearing the implant prosthesis less than three years and those more than seven years ($B_1<B_3$). CONCLUSION: The patients were generally satisfied with the outcome of implant treatment. But the patients' major complaint was high cost and while the statistically significant difference was not shown, the satisfaction scale about food impaction and esthetics was low. So the continuing efforts to make improvements about these problems are needed for the implant practitioners.

Effect of lining application techniques on microleakage in class II composite restorations (다양한 방식으로 적용한 이장재가 2급와동 복합레진 수복의 미세누출에 미치는 영향)

  • Hwang, Byung-Moon;Kim, Joo-Hyung;Park, Ji-Man;Millstein, Philip;Park, Eun-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.145-151
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the microleakage in class II cavity resin restorations used with resin-modified glass ionomer (RMGI) lining material depending on two different applying methods; classical delivery method using a dental explorer and a specially designed rotating bur. Materials and Methods: A total thirty-six extracted teeth were prepared with a class II proximal box, and randomly divided into three groups: 1) control group with no lining added and the proximal box restored (Group I), 2) the second group used RMGI as a lining material which was spread with an explorer (Group II), 3) the third group used a specially designed rotating bur to thin out RMGI (Group III). All teeth were restored with the same manner using incrementally placed resin composite. All 36 teeth were prepared and sectioned for the dye penetration test, and observed with a stereomicroscope for scoring the dye penetration. Results: When RMGI liners were used, both groups using an explorer and the special bur with the liner had significantly less microleakage than the control group with no liner (P < 0.05). The 50% of the group with RMGI liner using the bur showed no microleakage under a dye penetration test whereas all the teeth in control group showed microleakage of different degrees. However, there was no statistically significant difference between Group II and Group III. Conclusion: RMGI is an effective lining material to decrease microleakage in class II composite resin restorations regardless of applying methods.

Measuring System of Visual Evoked Potential (VEP) in Mice using BioPAC Modules (BioPAC 모듈을 이용한 마우스 시각유발전위 측정 시스템 확립)

  • Lee, Wang Woo;Ahn, Jung Ryul;Goo, Yong Sook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.16-24
    • /
    • 2017
  • For the development of feasible retinal prosthesis, one of the important elements is acquiring proper judging tool if electrical stimulus leads to patient's visual perception. If evoked potential to electrical stimulus is recorded in primary visual (V1) cortex, it means that the stimulus effectively evokes visual perception. Therefore, in this study, we established VEP recording system on V1 cortex using BioPAC modules as the judging tool. And the measuring system was evaluated by recording VEP of mice. After anesthesia, normal mice (C57BL/6J strain; n = 6) were secured to stereotaxic apparatus (Harvard Apparatus, USA). For the recording of VEP, the stainless steel needle electrode (impedance: $2-5k{\Omega}$) was positioned on the surface of the cortex through the burr hole at 2.5 mm lateral and 4.6 mm caudal to bregma. DA 100C and EEG 100C BioPAC modules were used for the trigger signal and VEP recording, respectively. When left eye was blocked by black cover and right eye was stimulated by flash light using HMsERG (RetVet Corp, USA), VEP response at left V1 cortex was detected, but there was no response at right V1 cortex. Amplitudes and latencies of P2, N3 peaks of VEP recording varied according to the depths of the electrodes on V1 cortex. From the surface upto $600{\mu}m$ depth, amplitudes of P2 and N3 increased, while deeper than $600{\mu}m$, those amplitudes decreased. The deeper the insertion depth of the electrode, the latency of N1 peaks tends to be delayed. However, there was no statistically significant difference among the latencies of P2 and N3 peaks (P > 0.05, ANOVA). Our VEP recording data such as the insertion depth and the latency and amplitudes of peaks might be used as guidelines for electrically-evoked potential (EEP) recording experiment in near future.

Effects of Hatha Yoga Exercise on Body Composition, Serum Lipids, and Health-Related Fitness of Obese Middle-Aged Women (하타요가 운동이 비만중년여성의 신체조성, 혈청지질 및 건강체력에 미치는 영향)

  • Kim, Do-Yeon;Lee, Jeong-Ah;Yang, Jum-Hong
    • Journal of Life Science
    • /
    • v.21 no.4
    • /
    • pp.521-528
    • /
    • 2011
  • The purpose of this study was to analyze the effects of Hatha Yoga exercise on the body composition, serum lipids, and health-related fitness of obese middle-aged women. The subjects in the Hatha Yoga exercise group (n=9) were 18 obese middle-aged women that trained for 16 weeks and a control group (n=9). Body composition, serum lipids, and health-related fitness were measured in all of the subjects before the start of the training program and at the end of the 16 weeks. The findings of this study were as follows. Body weight, %BF, BMI, WHR, VFA, TC, TG, LDL-C, FFA, and HOMA-IR significantly decreased, whereas LBM, HDL-C, grip strength, back strength, push-ups, sit-ups, Harvard step test, and sitting trunk flexion significantly increased in the Hatha Yoga exercise group after 16 weeks. Therefore, regular and continuous Yoga exercise was effective in improving body composition, serum lipids, and health-related fitness. Consequently, Yoga exercise could be effective for preventing cardiovascular disease caused by obesity in middle-aged women.

Enhancement of in vivo Radiosensitization by Combination with Pentoxifylline and Nicotinamide (Pentoxifylline과 Nicotinamide의 병용에 의한 생체내 방사선 감수성 증강 효과)

  • Lee Intae;Cho Moon-June
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 1991
  • Pentoxifylline (PENTO) has been known to improve RBC fluidity, and thus improve the flux of RBC through narrow capillaries. Additionally, PENTO also decreases the $O_2$ affinity of hemoglobin by increasing 2,3-DPG levels, thereby increasing the $O_2$ release from RBC. Nicotinamide (NA) has been reported to decrease the number of acutely hypoxic cells in tumors by temporarily increasing tumor blood flow. Therefore, the purpose of this study was to examine whether the combination of PENTO and NA (PENTO+NA) would reduce the radioresistance of the Fsall murine fibrosarcoma by oxygenating the hypoxic cells. We obsewed a significantly enhanced radiation-induced growth delay of the FSaII tumors by PENTO+NA. Thus the enhancement ratio was between 2.5 and 2.8 in growth delay assay. The $TCD_{50}$ of control tumors was about 57 Gy, but that of PENTO+NA treated tumors was about 32Gy. Thus $TCD_{50}$ was modified by a factor of 1.8. We also observed that PENTO+NA exerted no effect on the radiation-induced skin damage after the legs without bearing tumors were exposed to X-irradiation. In order to clarify radiosensitizing effects of PENTO+ NA, changes in tumor blood flow and intratumor pOf were measured using laser Doppler flowmetry and $O_2$ microelectrode methods. The tumor blood flow significantly increased at 10 min. after injection of PENTO+ NA. Furthermore, we also found that PENTO+ NA significantly increased intratumor $pO_2$ from 8 to 19 mmHg. We concluded that PENTO+MA was far more effective than NA alone or PENTO alone. The increase in the response of tumors in vivo to X-irradiation appeared to be due mainly to an increase in the tumor oxygenation. Further studies using various concentrations of PENTO alone and in combination with NA to obtain better sequencing and maximal radiosensitization are warranted.

  • PDF

Sensitivity Analysis of Satellite BUV Ozone Profile Retrievals on Meteorological Parameter Errors (기상 입력장 오차에 대한 자외선 오존 프로파일 산출 알고리즘 민감도 분석)

  • Shin, Daegeun;Bak, Juseon;Kim, Jae Hwan
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.481-494
    • /
    • 2018
  • The accurate radiative transfer model simulation is essential for an accurate ozone profile retrieval using optimal estimation from backscattered ultraviolet (BUV) measurement. The input parameters of the radiative transfer model are the main factors that determine the model accuracy. In particular, meteorological parameters such as temperature and surface pressure have a direct effect on simulating radiation spectrum as a component for calculating ozone absorption cross section and Rayleigh scattering. Hence, a sensitivity of UV ozone profile retrievals to these parameters has been investigated using radiative transfer model. The surface pressure shows an average error within 100 hPa in the daily / monthly climatological data based on the numerical weather prediction model, and the calculated ozone retrieval error is less than 0.2 DU for each layer. On the other hand, the temperature shows an error of 1-7K depending on the observation station and altitude for the same daily / monthly climatological data, and the calculated ozone retrieval error is about 4 DU for each layer. These results can help to understand the obtained vertical ozone information from satellite. In addition, they are expected to be used effectively in selecting the meteorological input data and establishing the system design direction in the process of applying the algorithm to satellite operation.