• Title/Summary/Keyword: Harmonics simulation

Search Result 507, Processing Time 0.019 seconds

Multiple-Period Repetitive Controller for Selective Harmonic Compensation with Three-Phase Shunt Active Power Filter

  • Zhang, Chao;Gong, Maofa;Zhang, Yijun;Li, Yuxia
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.819-829
    • /
    • 2015
  • This paper presents a shunt active power filter (SAPF) for compensating inter-harmonics and harmonics when inter-harmonics content is evident in the grid. The principle of inter-harmonics generation in the grid was analyzed, and the inter-harmonics effect on repetitive controllers was discussed in terms of control performance. Traditional repetitive controllers are not applicable in inter-harmonic compensation. Moreover, the effect of an ideal controller on harmonics signals was analyzed on the basis of the internal model principle. The repetitive controller was improved in the form of a basis function according to theoretical analysis. The finite-dimensional repetitive controller, which is also called the multiple-period repetitive controller, was designed for the control of multiple periodic signals. A selective harmonic compensation system was developed with SAPF. This system can be used to compensate harmonics and inter-harmonics in the grid. Finally, system control performance was verified by simulation and experimental results.

A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads (시간에 따라 변하는 고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Il-Moo;Wang, Yong-Peel;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.78-80
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the control synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

A Study on Harmonic Analysis and Countermeasure at the High Speed Railway Substation (고속전철 변전소의 고조파 분석과 대책에 관한 연구)

  • 김재철;박수만;강창원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.138-143
    • /
    • 2004
  • This paper analyzed harmonics from high speed railway traction to high speed railway substation and provide a reduction method of harmonics using the passive filter. A substation supplies the electric power to a train or can supply the electric power to several trains. According to the number of trains covered by a substation, characteristics of harmonics are investigated. These harmonics affect transformer heating and inductive interference. In order to get rid of the damage from the harmonics, this paper presented minimizing method of harmonics. The proposed method is verified in simulation using the PSCAD/EMTDC.

Torque Ripple Reduction based on Flux Linkage Harmonics Observer for an Interior PM Synchronous Motor including Back EMF Harmonics (왜곡된 역기전력을 갖는 매입형 영구자석 동기전동기의 쇄교자속 고조파 관측기를 이용한 토크리플 저감)

  • Jin, Yong-Sin;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.367-375
    • /
    • 2013
  • The mechanical vibration of a PM synchronous motor at low speeds due to the back emf harmonics may be serious problems in some application such as MDPS(Motor driven power steering), electric vehicles. In this paper, torque ripple reduction for an interior PM synchronous motor including back emf harmonics is proposed. The dq flux linkage harmonics of the permanent magnet are estimated on real time by using the dq currents of the real system and the model of the MRAS observer. Based on the estimated flux linkage harmonics, the dq harmonic currents for reducing the torque ripples are compensated on the dq reference currents. The estimation of the flux linkage harmonics by the MRAS observer and the torque ripple reduction of the proposed algorithm was verified by the simulation and experiment.

A Study on the PWM Pattern for Harmonics Reduction in GTO Inverter (GTO 인버터의 고조파 저감을 위한 PWM 패턴에 관한 연구)

  • Cha, Min;Park, Young-Jeen;Hong, Soon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1978-1981
    • /
    • 1997
  • This paper describes several PWM method for harmonics reduction in GTO inverter. The analysis and simulations of PWM techniques are carried out. The simulation results demonstrate that the programmed PWM methods(SHE PWM) are superior to the sine-modulated PWM method. The selected harmonic elimination (SHE) PWM scheme which eliminates specific lower order harmonics can generate high quality output waveform in PWM inverter.

  • PDF

Reluctance Synchronous Motor Driving using SV PWM (SV PWM을 이용한 고속 릴럭턴스 동기 전동기 구동)

  • 김민태;오성업;성세진;백동기
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.204-207
    • /
    • 1998
  • Many Harmonics components is contained within the stator currents of the High-speed Reluctance Synchronous Motor with salient pole rotor. They cause the power factor of RSM to get worse. In this paper, the mathematical model of RSM is investigated. And SV-PWM control method is applied to reduce Harmonics components in the stator currents. Simulation results shows the fast response of speed and the reduction of Harmonics components at steady state

  • PDF

Digital simulation of hysteresis motor performance using Preisach model considering time and space harmonics (Preisach 모델을 이용한 히스테리시스 모터 고조파 특성 시뮬레이션)

  • Jung, Hoon;Hong, Sun-Ki;Won, Jong-Su
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.5-8
    • /
    • 1988
  • A digital simulation method for Hysteresis motor using Preisach model is proposed. From this, the instantaneous torque, hysteresis loss of rotor can be calculated, considering slot and winding distribution and current harmonics.

  • PDF

New Active Damping Strategy for LCL-Filter-Based Grid-Connected Inverters with Harmonics Compensation

  • Hu, Guozhen;Chen, Changsong;Shanxu, Duan
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.287-295
    • /
    • 2013
  • The use of LCL filters in pulse width modulation voltage source converters is a standard solution for providing proper attenuation of high-order grid-current harmonics. However, these filters can cause the undesired effect of resonance. This paper proposes an active damping strategy with harmonics compensation. It can alleviate the harmonics around the resonance frequency caused by the LCL filters. The proposed strategy is attractive since it is simple, does not depend on grid parameters and does not increase the number of sensors. Simulation and experimental results verify the effectiveness of the proposed active damping strategy.

Output Voltage Regulation for Harmonic Compensation under Islanded Mode of Microgrid

  • Lim, Kyungbae;Choi, Jaeho
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.464-475
    • /
    • 2017
  • This study examines a P+multi resonant-based voltage control for voltage harmonics compensation under the islanded mode of a microgrid. In islanded mode, the inverter is defined as a voltage source to supply the full local load demand without the connection to the grid. On the other hand, the output voltage waveform is distorted by the negative and zero sequence components and current harmonics due to the unbalanced and nonlinear loads. In this paper, the P+multi resonant controller is used to compensate for the voltage harmonics. The gain tuning method is assessed by the tendency analysis of the controller as the variation of gain. In addition, this study analyzes the slight voltage magnitude drop due to the practical form of the P+multi resonant and proposes a counter method to solve this problem by adding the PI-based voltage restoration method. The proposed P+multi resonant controller to compensate for the voltage harmonics is verified through the PSIM simulation and experimental results.

A Study on the Analysis of Harmonics Reduction Effects Using Single-tuned Filters In a Power System Included Power Converters (전력변환장치를 포함한 전력시스템에서 동조 필터를 이용한 고조파 저감 효과의 분석에 관한 연구)

  • 최홍규;김경철;강태은;전기원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.81-87
    • /
    • 2000
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system. High harmonics currents and voltages will cause equipment damage and disturb the plant operation. The common solution to harmonics problem is to use harmonics filters. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of the single-tuned filter for harmonic elimination are presented.

  • PDF