References
- R.-J. Wai and W.-H. Wang, "Grid-connected photovoltaic generation system," IEEE Trans. Circuits and Syst., Vol. 55,No. 3, pp. 953-964 , Apr. 2008. https://doi.org/10.1109/TCSI.2008.919744
- J. L. Agorreta, M. Borrega, and J. Lopez, "Modeling and control of n-paralleled grid-connected inverters with lcl filter coupled due to grid impedance in pv plants," IEEE Trans. Power Electron., Vol. 26, No. 3, pp. 770-785, Mar. 2011. https://doi.org/10.1109/TPEL.2010.2095429
- S. Cobreces, E. Bueno, F. J. Rodriguez, F. Huerta, and P. Rodriguez, "Influence analysis of the effects of an inductive-resistive weak grid over L and LCL filter current hysteresis controllers," in European Conference on Power Electronics and Applications, pp. 1-10, Sep. 2007.
- S.-Y. Park, C.-L. Chen, and J.-S. Lai, "Admittance compensation in current loop control for a grid-tie lcl fuel cell inverter," IEEE Trans. Power Electron., Vol. 23,No. 4,pp. 1716-1723, Jul. 2008. https://doi.org/10.1109/TPEL.2008.924828
- M. Castilla, J. Miret, J. Matas, L. Garcia de Vicuna, J. M. Guerrero, "Control design guidelines for single-phase grid-connected photovoltaic inverters with damped resonant harmonic compensators," IEEE Trans. Ind. Electron., Vol. 56, No. 11, pp. 4492-4501, Nov. 2009. https://doi.org/10.1109/TIE.2009.2017820
- C. Wessels, J. Dannehl, and F. W. Fuchs, "Active damping of LCL-filter resonance based on virtual resistor for PWM rectifiers-stability analysis with different filter parameters," in Power Electronics Specialists Conference (PESC), pp.3532-3538, 2008.
- W. Gullvik, L. Norum, and R. Nilsen, "Active damping of resonance oscillations in LCL-filters based on virtual flux and virtual resistor," in European Conference on Power Electronics and Applications, pp.1-10, Sep. 2007.
- V. Blasko and V. Kaura, "A novel control to actively damp resonance in input lc filter of a three-phase," IEEE Trans. Ind. Appl., Vol. 33,No. 2,pp. 542-550, Mar./Apr. 1997. https://doi.org/10.1109/28.568021
- E. Twining and D. G. Holmes, "Grid current regulation of a three-phase voltage source inverter with an LCL input filter,"IEEE Trans. Power Electron., Vol. 18, No. 3, pp. 888-895, May 2003.
- F. Liu, Y. Zhou, S. Duan, J. Yin, B. Liu, and F. Liu, "Parameter design of a two-current-loop controller used in a grid-connected inverter system with lcl filter," IEEE Trans. Ind. Electron., Vol. 56, No. 11, pp. 4483-4491, Nov. 2009. https://doi.org/10.1109/TIE.2009.2021175
- G. Shen, X. Zhu, J. Zhang, and D. Xu, "A new feedback method for pr current control of lcl filter-based grid-connected inverter," IEEE Trans. Ind. Eletron., Vol. 57, No. 6, pp. 2033-2041,Jun. 2010. https://doi.org/10.1109/TIE.2010.2040552
- M. Liserre, A. Dell'Aquila, and F.Blaabjerg, "Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier," IEEE Trans. Power Electon., Vol. 19, No. 1, pp. 76-86, Jan. 2004. https://doi.org/10.1109/TPEL.2003.820540
- J. Dannehl, M. Liserre, and F. W. Fuchs, "Filter-based active damping of voltage source converters with lcl filter," IEEE Trans. Ind. Electron., Vol. 58, No. 8, pp. 3623-3633, Aug. 2011. https://doi.org/10.1109/TIE.2010.2081952
- F. Wang, J. L. Duarte, M. A. M. Hendrix, and P. F. Ribeiro. "Modeling and analysis of grid harmonic distortion impact of aggregated dg inverters," IEEE Trans. Power Electron. Vol. 26, No. 3, pp. 786-797, Mar. 2011. https://doi.org/10.1109/TPEL.2010.2091286
- M. H. Bierhoff and F. W. Fuchs, "Active damping for three-phase pwm rectifiers with high-order line-side filters," IEEE Trans. Ind. Electron., Vol. 56, No. 2, pp. 371-379, Feb. 2009. https://doi.org/10.1109/TIE.2008.2007950
- K. Xue-juan, L. Fang, P. Li , and K. Yong. "Implement and parameter design of dpll for invertors based on cycle control," Proceeding of CSEE, Vol. 27, No. 1, pp. 1-10, 2007.
Cited by
- LCL filter design for VSC-HVDC systems supplying passive grids vol.152, 2017, https://doi.org/10.1016/j.epsr.2017.07.006
- Simplified Controller Design Method for Digitally Controlled LCL-Type PWM Converter with Multi-resonant Quasi-PR Controller and Capacitor-Current-Feedback Active Damping vol.14, pp.6, 2014, https://doi.org/10.6113/JPE.2014.14.6.1322
- Topologies, generalized designs, passive and active damping methods of switching ripple filters for voltage source inverter: A comprehensive review vol.62, 2016, https://doi.org/10.1016/j.rser.2016.04.006
- Analysis and Design of Grid-Connected Photovoltaic Systems With Multiple-Integrated Converters and a Pseudo-DC-Link Inverter vol.61, pp.7, 2014, https://doi.org/10.1109/TIE.2013.2281153
- Application of a C-Type Filter Based LCFL Output Filter to Shunt Active Power Filters vol.13, pp.6, 2013, https://doi.org/10.6113/JPE.2013.13.6.1058
- Direct grid-side current model predictive control for grid-connected inverter with LCL filter pp.1755-4543, 2018, https://doi.org/10.1049/iet-pel.2018.5338
- Improved adaptive notch filter-based active damping method for shunt active power filter with LCL-filter vol.100, pp.3, 2018, https://doi.org/10.1007/s00202-018-0685-9
- A Proportional Resonant Controller for Suppressing Resonance in Grid Tied Multilevel Inverter vol.11, pp.5, 2018, https://doi.org/10.3390/en11051024