• 제목/요약/키워드: Harmonics reduction

검색결과 263건 처리시간 0.029초

부스트 방식 역률개선회로의 설계와 특성분석 (Analysis of continuous conduction mode boost power-factor-correction circuit)

  • 김철진;장준영;김상덕;송요창;윤신용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1120-1122
    • /
    • 2002
  • Switching power supply are widely used in many industrial field. Power factor improvement and harmonic reduction technique is very important in switching power supply. The power factor correction (PFC) circuit using boost converter used in input of power source is studied in this paper. It is analyzed distortional situations and harmonics of input currents that presented at continuous conduction mode(CCM) of boost PFC circuit. It is done simulations of harmonics distribution according to load variation by using PSPICE and MATLAB. From the actual experiment of boost PFC circuit the validity of the analysis is confirmed.

  • PDF

포화특성을 고려한 리액터의 특성 분석 (Characteristics Analysis of Reactor Considering Magnetization Saturation)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.92-98
    • /
    • 2012
  • As the increasing of non-linear load, filter is coming to be high gradually in order to reduce the harmonic which occurs from the power conversion. The maintenance of passive filter is easier than active filter and it has been widely used in the industrial site. This passive filter is connected with condenser and reactor by series and parallel and it is installed at the front of nonlinear load. The breakdown of passive filter occurs frequently at the reactor side rather than capacitor. So the breakdown cause close examination is necessary. In this paper, we analyzed that the electric stress of reactor which is considered magnetization saturation at the passive filter. We confirm that the reduction of harmonics and the electric stress of reactor is influenced by the linear and non-linear element of reactor.

비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads)

  • 김종겸;박영진;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

전류주입식 능동전력 필터를 위한 최적주입방법의 해석 (Analysis of Optimized Injection Method for Active Power Filter of Current Injection Type)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.296-303
    • /
    • 1986
  • The active filter of current injection type is the device which eliminates the harmonics in ac line by injecting the harmonic compensating current into the ac side. And its harmonic reduction performance is entirely dependent on the control scheme of the current-fed inverter and the harmonic compensating current becomes the PWM wave by the inverter. This PWM compensating current can be determined by selecting the switching function properly which eliminates the harmonics up to any order with using no independent sources. The new injection current model is derived by the proposed method which is called the optimized injection method. The overall characteristics of the proposed method are investigated through digital computation and the feasibility is proved with experimental results obtained from the Z-80 microcomputer control of the active filter.

  • PDF

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

고조파 저감을 위한 직접 주파수 변환기에 대한 연구 (A Study on the Direct Frequency Changer for Harmonics reduction.)

  • 서영수;임영배;김성균;김성기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1092-1094
    • /
    • 1992
  • Allowing for the fact that the load requiring for high speed has been incrased lately, this paper deals with a method that can consecutively convert the frequency from low frequency to high frequency. And this paper also shows the reduced effect of harmonics and the effectiveness or the proposed system, which are thoughly tested and proved through the experiments in the output frequency range of from 5Hz to 1200Hz.

  • PDF

직.병렬 능동 전력필터 시스템을 이용한 불평형 전원전압 보상 (The Compensating Unbalanced Source Voltages for Unified Active Power Filter System)

  • 김영석;강민형
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.716-723
    • /
    • 2007
  • This paper suggests of a 3-phase 3-wire unified active power filter. The system is composed of a series active power filter and a parallel active power filter. The proposed series active power filter compensating unbalance source voltage and current harmonics of the parallel active power filter improves power factor. The proposed algorithm which improves for power factor and harmonic reduction are calculated by the performance function, and which compensates for the unbalanced source voltage is calculated based on the symmetrical component analysis. We composed a combined system of the series active power filter and parallel active power filter to confirm a validity of the proposed control methods. The effectiveness of the proposed algorithm is confirmed by the experiments.

영구자석 계자형 동기발전기의 고주파 저감을 위한 자기회로 최적설계 (Shape Optimization for the EMF Harmonics Reduction of PM Type Synchronous Generators)

  • 김영균;이재건;임양수;강규홍;홍정표;장기찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권10호
    • /
    • pp.494-500
    • /
    • 2001
  • This paper presents the shape optimization to minimize the BEMF(Back Electro-Motive Force) harmonics of PM type synchronous generators. RSM(Response Surface Methodology) is well adapted to make analytical model for a complex problem considering a lot of interaction of design variables. In this paper, RSM is used to find the optimal solution. The 2D-Finite Element Method is used to obtain the observer data of the BEMF and SQP(Sequential Quadratic Problem method) is used to solve the constrained nonlinear optimization problem.

  • PDF

2중 영 벡터 모드를 갖는 2상 개별 펄스 위치 변조기법 (A Two-Phase Separately Randomized Pulse Position PWM Technique with Double-Zero Vector Mode)

  • 김정근;오승열;정영국;임영철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권12호
    • /
    • pp.739-750
    • /
    • 2004
  • In case while M(modulation index) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP-PWM scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP-PWM, this paper proposes a two-phase SRP-PWM(DZSRP-PWM) with double zero vector mode which zero vector is selected as V(111) in case of M >0.7, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, the PSIM simulations and experiments were achieved. And the simulation and experiment results show that the voltage and current harmonics all over the modulation index are spread to a wide band area.

PID Autotuning Algorithm Based on Saturation Function Feedback

  • 오승록
    • 전기전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.263-269
    • /
    • 1998
  • 릴레이 대신 포화함수를 이용하여 선형 플랜트의 극한 이득과 주기를 결정하였다. 포화함수를 사용함으로서 플랜트의 고주파 성분을 감소 시켜 묘사함수 사용에 의한 극한이득과 주기 결정의 정확도를 증가시켰다. 또한 적절한 포화함수를 사용할 수 있는 간단한 절차를 기술하였으며 진동이 발생하지 않는 플랜트에 대해서 지연요소를 이용한 자동동조 방법을 제시하였다.

  • PDF