Planar type high-$T_{c}$ Superconductor 11-pole Lowpass Filter for Suppression of Harmonics (고조파 억제용 고온초전도 평면형 11-극 저역통과 필터의 제작)

  • 강광용;김철수;곽민환
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.159-162
    • /
    • 2002
  • The eleventh-order coupled line lowpass filter(LPF) was designed to suppress harmonics and spurious signals. The microstrip type LPF was fabricated using a high-$T_{c}$ superconductor(HTS) $YBa_{2}$$Cu_{3}$$O_{7-x}$(YBCO) thin film with the $CeO_{2}$ buffer layer which was deposited on the sapphire ($Al_{2}O_{3}$) substrate of 30 x 30 $mm^{2}$. The coupled-line type LPF was designed for 1.2 GHz of cutoff frequency with 0.01 dB of ripple level at passband. The fabricated HTS LPF shows excellent attenuation characteristics in stopband of 1.2~9.5GHz (7-attenuation poles in the stopband), and shows low insertion loss (0.2 dB) and return loss (17.1 dB) in the pass- band. These measured results match well with those obtained by the EM simulation. This clearly demonstrates that the HTS LPF can suppress harmonics and spurious signals effectively.

  • PDF

Harminic Suppression of Band Pass Filter Using Photonic Band Gap Structure (PBG 구조를 이용한 대역통과 여파기 고조파 억제에 관한 연구)

  • Seo Chulhun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.1
    • /
    • pp.69-72
    • /
    • 2004
  • A bandpass filter has been designed by employing the PBG structure and the aperture on the ground together in this paper. The harmonics of band pass filter have been suppressed by employing the PBG structure and the bandwidth of it has been broadened by using the aperture on the ground. The three kinds of PBG structures has been combined to suppress the harmonics of the filter The center frequency of filter is 2.2 GHz and the bandwidth has been increased from $40\%$ by the aperture and all harmonics were suppressed about 35dBc by the PBG. The insertion loss has been reduced 3.0dB to 2.6dB.

A study on reducing the harmonics in inverter system for fluorescent lamp (형광등용 인버터 시스템의 고조파 저감에 관한 연구)

  • Park, Chan-Kun;Kim, Jong-Yun;Jeon, Nae-Suck;Park, Jeung-Hwan;Lee, Sung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1199-1201
    • /
    • 2000
  • This paper proposes a harmonics reducing circuit for fluorescent lamp inverters using hybrid type smoothing circuit with pumping and smoothing capacitors. A waveform of full-wave rectification used as a direct current power supply at fluorescent lamp inverters contains a lot of harmonic wave from inrush current which is generated near the maximum of input voltage with purse shape when voltage smoothing capacitor is charged. Therefore, in order to suppress inrush current which will result in harmonic wave. this paper proposes a method to control abrupt charging current by use of charging voltage at pumping capacitor. The suppression of harmonics generation at lamp current is confirmed through simulations.

  • PDF

Estimation of Harmonics on Power System of AC Electric Railway (교류 전기철도 전력계통의 고조파 예측량 계산)

  • 송진호;황유모
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.68-79
    • /
    • 2003
  • We estimated harmonics on power system of AC railway based on quantitatively measured harmonics and investigated the need of facilities for harmonics reduction. In order to analysis harmonics which inflow into power system due to increase in collector voltages and harmonic currents generated from the train when the railway is in operation, the railway system Is sectioned into power supply, railway line, AT, sectioning Post and subsectioning post. For analysis of extension of currents resulting from the railway loads, PWM converter, VVVF inverter and the feeder system are modeled based on the dynamic node technique(DNT). In order to test the usefulness of the DNT for analysis of harmonic effects, the measured harmonic currents and harmonic magnification ratios at the S/K substation are compared with simulation results using DNT modelling, which include the results for two cases with and without filters for suppression of harmonic currents. When 8 cars(4M4T) are in operation, the total sum of harmonic currents resulting from the train at M and T phases, which inflow into the substation along with the railway line, is calculated. Using the harmonics analysis program for railway feeder system with these data, the total harmonic distortion factor(710) at the outgoing point of KEPCO substation is computed. The calculation shows that when the maximum THD at the receiving point of H/K substation was 0.0443% which is much lower than 1.5% which is the allowable value of KEPCO at 154kV as well as IEEE-519 above 132kV This result indicates that any measure for harmonics reduction in Incheon International Airport Railway is not needed.

Voltage Distortion Suppression for Off-grid Inverters with an Improved Load Current Feedforward Control

  • Geng, Yiwen;Zhang, Xue;Li, Xiaoqiang;Wang, Kai;Yuan, Xibo
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.716-724
    • /
    • 2017
  • The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.

Size and Harmonic Reduced Wilkinson Balun Using Parallel Coupled Line with Open Stub

  • Lee, Won-Kyun;Hwang, Hee-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.387-392
    • /
    • 2014
  • In this paper, a size-reduced Wilkinson balun with wide harmonic-suppressed band is presented. An accurate analysis of the parallel coupled line with an open stub (PCL-OS) is carried out. The PCL-OS structure shows excellent low pass filter and harmonic-suppression characteristics, which is useful for designing a low pass filter unit cell (LUC) with a reduced size. The designed Wilkinson balun at a 2.45 GHz center frequency not only shows an excellent harmonic suppression including the 5th harmonics up to 14 GHz over 15 dB, but it also has an area reduced to 48% of the conventional one.

Design of a 5.8 GHz Narrow Band-pass Filter with Harmonics Suppression (고조파가 억제된 5.8 GHz 협대역 대역통과 여파기)

  • Yoon, Ki-Cheol;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2A
    • /
    • pp.167-173
    • /
    • 2008
  • In this paper, the flexible narrow bandpass filters (BPFs) with ${\lambda}$g/4 short and ${\lambda}$g/2 open stubs by microstrip line on duroid substrate are suggested. These BPFs with narrow bandwidth show flexible bandwidth with variation of the position of the stubs using the Qe (external quality factor) without changing the impedance value at microwave range. On the other hand, by replacing the series quarter-wavelength connecting lines with the equivalent T-shaped line of bandstop filter(BSF), the compact stub bandpass filter with harmonics suppression can be realized. The BPF with ${\lambda}$g/4 short stubs shows the insertion loss of 2.1 dB and the return loss of 18 dB and BPF with ${\lambda}$g/2 open stubs shows the insertion loss of 1.2 dB and the return loss of 21.9 dB at the center frequency of 5.8 GHz and the bandwidth of 10 %.

SIR CPW Bandpass Filter with Folded Feed Structure for Suppressing Spurious Harmonics (고조파 억압을 위한 접힌 피드 구조를 갖는 SIR CPW 대역통과 여파기)

  • 박광선;이창언;천동완;이진택;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.159-164
    • /
    • 2004
  • In this paper, we have proposed the folded feed structure for the spurious harmonic suppression and we have designed the SIR CPW bandpass filter using this feed structure. The characteristic of the proposed feed structure was similar to that of the lowpass filter has wide stopband region and this can be used usefully to the spurious harmonic suppression of the bandpass filter. From the simulation and the measurement result, SIR CPW bandpass filter with folded feed structure has good harmonic suppression characteristics up to 5.8 f$\sub$0/ with -20 dB suppression level.

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

RF NOISE SUPPRESSION ON COPLANAR TRANSMISSION LINE USING LOSS GENERATION OF THE SOFT MAGNETIC FILMS

  • Kim, Ki-Hyeon;Shinji Ikeda;Masahiro Yamaguchi;Arai, Ken-Ichi;Hideaki Nagura;Shigehiro ohnuma
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.200-201
    • /
    • 2002
  • Recently, a countermeasure for the electromagnetic noise emission on RF integrated transmission line using the loss generation of ferromagnetic thin films is briefly suggested$\^$1,2/. Without the magnetic film, the noise harmonics of the signal pass through the transmission line with only a little attenuation. The ideal role of magnetic film is not to raise insertion losses in the pass-band and to give as large attenuation as possible to eliminate the noise harmonics at the stop-band, the frequency range higher than the meaningful signal as shown in Fig. 1. and Fig. 2. (omitted)

  • PDF