Harmonic Analysis of Reactor and Capacitor in Single-tuned Harmonic Filter Application

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권2호
    • /
    • pp.239-244
    • /
    • 2011
  • Industrial power distribution system includes many kinds of non-linear loads, which produce the harmonics during energy conversion transition. The single-tuned passive filter is widely used to absorb the harmonics and attenuate its undesirable effect in the distribution system. However, the passive filter might be severely stressed, and sometimes even damaged, due to the absorption of harmonics. There is voltage rise on the capacitor when the single-turned harmonic filter is applied. When the capacitor voltage rose above the allowable limit, the expected life of the capacitor will considerably deteriorate. On the other hand, the reactor can experience the spike voltage even if the voltage and current of the capacitor are within the allowable limit, and this accumulated voltage stress of the reactor causes its premature fault. In this paper, we analyzed and compared the harmonic voltage and current of the reactor and capacitor in a single-tuned harmonic filter through the EMTP software and verified them with the experimental results.

변전소 고조파 측정 및 분석에 관한 연구 (A Study on Measurement and Analysis of Harmonics in Substation)

  • 한무호;박태준;이성희;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

전기설비의 고조파 분석을 위한 측정 시스템의 개발 (Development of Measurement System for Harmonic Analysis of Electric Equipment)

  • 유재근;이상익;전정채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2002
  • Recently, according to the spread of semiconductor applied technology like motor speed control contrivance, power conversion installation and so on, harmonic ingredients occurred in switching operation flow into a distribution system and increase voltage distortion of distribution system and bring on obstacles like damage, lowering of capability, false operation and so on of various electrical installation. So, in order to consider a countermeasure to limit occurrence quantity of harmonic source, harmonic interception and others, precision measurement and analysis on voltage, current, power, power factor, the each ingredient of harmonic order, the percentage of total harmonic distortion and so forth are needed. In this paper monitoring system to measure and analyze power quality connected with power harmonics was developed and it's performance is verified by measuring and analyzing three-phase voltage and current of R, S, T in the three-phase and four-wire system using the developed measurement system.

  • PDF

컨트롤 차트를 이용한 고조파 전압 왜곡 발생원 관리기법 연구 (Study of Harmonic Sources Management Method using Control Chart)

  • 한종훈;이계병;장길수;박창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.197-198
    • /
    • 2011
  • A technique to manage harmonic pollution at the point of common coupling (PCC) has been presented using a control chart. The recursive least-squares technique has been used to estimate the parameters of the Thevenin equivalent load model. With the estimated data from the measured voltage and current waveform at the PCC during certain period violating upper control limit, the individual contributions to the distortion of voltage waveform at an interested harmonic frequency have been calculated and shown by simple graph.

  • PDF

A Study on the Harmonics Effect of SVC in Electric Arc Furnace Loads

  • Kim, Kyung-Chul;Jin, Seong-Eun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.54-60
    • /
    • 2006
  • Large steel industries have time-varying nonlinear loads such as electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. The main objective of the static var compensator is to maintain the rms voltage at the point of common coupling within the limit. In this research, harmonic mitigation studies were conducted with and without the SVC, and time-varying harmonics were evaluated according to the international harmonic standards (IEC 61000-3-6 and IEEE Std. 519) using a cumulative probabilistic approach.

A Ripple Rejection Inherited RPWM for VSI Working with Fluctuating DC Link Voltage

  • Jarin, T.;Subburaj, P.;Bright, Shibu J V
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2018-2030
    • /
    • 2015
  • A two stage ac drive configuration consisting of a single-phase line commutated rectifier and a three-phase voltage source inverter (VSI) is very common in low and medium power applications. The deterministic pulse width modulation (PWM) methods like sinusoidal PWM (SPWM) could not be considered as an ideal choice for modern drives since they result mechanical vibration and acoustic noise, and limit the application scope. This is due to the incapability of the deterministic PWM strategies in sprawling the harmonic power. The random PWM (RPWM) approaches could solve this issue by creating continuous harmonic profile instead of discrete clusters of dominant harmonics. Insufficient filtering at dc link results in the amplitude distortion of the input dc voltage to the VSI and has the most significant impact on the spectral errors (difference between theoretical and practical spectra). It is obvious that the sprawling effect of RPWM undoubtedly influenced by input fluctuation and the discrete harmonic clusters may reappear. The influence of dc link fluctuation on harmonics and their spreading effect in the VSI remains invalidated. A case study is done with four different filter capacitor values in this paper and results are compared with the constant dc input operation. This paper also proposes an ingenious RPWM, a ripple dosed sinusoidal reference-random carrier PWM (RDSRRCPWM), which has the innate capacity of suppressing the effect of input fluctuation in the output than the other modern PWM methods. MATLAB based simulation study reveals the fundamental component, total harmonic distortion (THD) and harmonic spread factor (HSF) for various modulation indices. The non-ideal dc link is managed well with the developed RDSRRCPWM applied to the VSI and tested in a proto type VSI using the field programmable gate array (FPGA).

전력계통 고조파 유입 유출 분석에 관한 연구 (A Study on the Analysis of Harmonic Injection and Emission for Power System)

  • 왕용필;정종원;김세동;곽노홍;전영수;박상호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

송전계통 고조파 유입/유출 분석 (Analysis of Harmonic Incoming and Outgoing for Transmission System)

  • 왕용필;최선영;곽노홍;전영수;박상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.561-562
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

충전기 고조파 잡음에 강인한 배터리 내부저항 측정 시스템 (Battery Internal Resistance Measurement System Robust to Charger Harmonic Noise)

  • 이형규;김기택
    • 전기전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.1129-1135
    • /
    • 2020
  • 배터리를 사용함에 따라 노화가 진행되면 배터리의 충전 가능 용량을 나타내는 State of Health(SoH)가 줄어들게 된다. 배터리 모니터링 시스템(BMS)에서 SoH를 추정하는 것이 매우 중요하며, 이를 위해 배터리 내부 저항을 측정하는 방법이 많이 사용된다. 일반적으로 배터리에 특정한 주파수의 전류원을 인가하고 전압응답을 측정하여 내부저항을 연산한다. 충전기가 동작할 경우 전압응답에 충전 고조파 잡음이 발생하여 저항 측정의 정확도가 떨어진다. 본 논문에서는 충전잡음의 영향을 제거하기 위하여 강인한 배터리 내부저항 측정 알고리즘을 제안하였다. 전류원 신호와 전압응답 신호를 일정한 주기 동안 적분하여 잡음을 제거하는 방법으로 우수한 정확도와 안정된 연산결과를 보였다. 무정전 전원장치용 BMS에 적용하여 제안한 방법의 유용함을 입증하였다.

전기로 부하에서 SVC의 고조파 및 플리커 효과에 관한 연구 (A Study on the Harmonic and Flicker Effects of SVC in Electric Arc Furnace Loads)

  • 김경철;최형범;오정석
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.150-158
    • /
    • 2007
  • 규모가 큰 제철소는 전기로를 포함한 시간에 따라 변하는 비선형 부하를 가지고 있다. 이들 비선형 부하는 고조파 전류를 발생시키고, 전력계통의 전압을 왜곡시킨다. 플리커는 전압 변동의 크기에 따라 램프의 방출 변화에 의한 인간의 지각 효과로 정의된다. SVC의 주 목적은 공통결합점에서 전압을 한계값 이하로 유지하는데 있다. 본 논문에서는 SVC 투입 전후의 고조파와 플리커 저감 효과를 분석하고, IEC 61000-3-6과 IEC 61000-3-7에 의해 평가하였다.